Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Med Imaging ; 24(1): 39, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336622

RESUMO

BACKGROUND: Coronary computed tomography angiography stenosis score (CCTA-SS) is a proposed diagnosis score that considers the plaque characteristics, myocardial function, and the diameter reduction rate of the lesions. This study aimed to evaluate the diagnostic performance of the CCTA-SS in seeking coronary artery disease (CAD). METHODS: The 228 patients with suspected CAD who underwent CCTA and invasive coronary angiography (ICA) procedures were under examination. The diagnostic performance was evaluated with the receiver operating curve (ROC) for CCTA-SS in detecting CAD (defined as a diameter reduction of ≥ 50%) and severe CAD (defined as a diameter reduction of ≥ 70%). RESULTS: The area under ROC (AUC) of CCTA-SS was 0.909 (95% CI: 0.864-0.943), which was significantly higher than that of CCTA (AUC: 0.826; 95% CI: 0.771-0.873; P = 0.0352) in diagnosing of CAD with a threshold of 50%. The optimal cutoff point of CCTA-SS was 51% with a sensitivity of 90.66%, specificity of 95.65%, positive predictive value of 98.80%, negative predictive value of 72.13%, and accuracy of 91.67%, whereas the optimal cutoff point of CCTA was 55%, and the corresponding values were 87.36%, 93.48%, 98.15%, 65.15%, and 88.60%, respectively. With a threshold of 70%, the performance of CCTA-SS with an AUC of 0.927 (95% CI: 0.885-0.957) was significantly higher than that of CCTA with an AUC of 0.521 (95% CI: 0.454-0.587) (P < 0.0001). CONCLUSIONS: CCTA-SS significantly improved the diagnostic accuracy of coronary stenosis, including CAD and severe CAD, compared with CCTA.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Angiografia por Tomografia Computadorizada/métodos , Constrição Patológica , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Valor Preditivo dos Testes
2.
J Clin Anesth ; 94: 111367, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38232466

RESUMO

The adrenal gland is a vital endocrine organ, and adrenal steroid synthesis and secretion are closely regulated by the hypothalamic-pituitary-adrenal (HPA) axis in response to various stimuli. Surgery or trauma can activate the HPA axis and induce the secretion of cortisol. Different cortisol responses vary with the grade of surgery. Perioperative medications have the potential to decrease the cortisol level in the body, and both excessive and insufficient cortisol levels after surgery are disadvantageous. The effect of perioperative medications on the HPA response to surgery can be divided into three levels: "adrenal insufficiency (AI)", "stress response inhibition", and "uncertainty". The clinical presentation of AI includes fatigue, nausea, vomiting, abdominal pain, muscle cramps, hypotension, hypovolemic shock and prerenal failure, which may result in fatal consequences. Stress response inhibition can reduce postoperative complications, such as pain and cognitive dysfunction. This is protective to patients during perioperative and postoperative periods. The aim of the present review is to shed light on current evidence regarding the exact effects and mechanisms of perioperative medications on the HPA response to surgical injury and provide the applicable guidance on clinical anesthesia.


Assuntos
Insuficiência Adrenal , Hidrocortisona , Humanos , Glucocorticoides/uso terapêutico , Sistema Hipotálamo-Hipofisário , Sistema Hipófise-Suprarrenal , Insuficiência Adrenal/etiologia , Insuficiência Adrenal/tratamento farmacológico , Complicações Intraoperatórias/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA