Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 403
Filtrar
1.
Breast Cancer Res Treat ; 206(1): 45-56, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38616207

RESUMO

PURPOSE: The significance of postmastectomy radiotherapy (PMRT) in breast cancer patients who initially have clinically node-positive (cN +) status but achieve downstaging to ypN0 following neoadjuvant chemotherapy (NAC) remains uncertain. This study aims to assess the impact of PMRT in this patient subset. METHODS: Patients were enrolled from West China Hospital, Sichuan University from 2008 to 2019. Overall survival (OS), Locoregional recurrence-free survival (LRFS), distant metastasis-free survival (DMFS), and breast cancer-specific survival (BCSS) were estimated using the Kaplan-Meier method and assessed with the log-rank test. The impact of PMRT was further analyzed by the Cox proportional hazards model. Propensity score matching (PSM) was performed to reduce the selection bias. RESULTS: Of the 333 eligible patients, 189 (56.8%) received PMRT, and 144 (43.2%) did not. At a median follow-up period of 71 months, the five-year LRFS, DMFS, BCSS, and OS rates were 99.1%, 93.4%, 96.4%, and 94.3% for the entire cohort, respectively. Additionally, the 5-year LRFS, DMFS, BCSS, and OS rates were 98.9%, 93.8%, 96.7%, and 94.5% with PMRT and 99.2%, 91.3%, 94.9%, and 92.0% without PMRT, respectively (all p-values not statistically significant). After multivariate analysis, PMRT was not a significant risk factor for any of the endpoints. When further stratified by stage, PMRT did not show any survival benefit for patients with stage II-III diseases. CONCLUSION: In the context of comprehensive treatments, PMRT might be exempted in ypN0 breast cancer patients. Further large-scale, randomized controlled studies are required to investigate the significance of PMRT in this patient subset.


Assuntos
Neoplasias da Mama , Mastectomia , Terapia Neoadjuvante , Estadiamento de Neoplasias , Humanos , Feminino , Neoplasias da Mama/patologia , Neoplasias da Mama/terapia , Neoplasias da Mama/mortalidade , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/radioterapia , Pessoa de Meia-Idade , Terapia Neoadjuvante/métodos , Adulto , Idoso , Estudos Retrospectivos , Radioterapia Adjuvante/métodos , Quimioterapia Adjuvante/métodos , Metástase Linfática , Recidiva Local de Neoplasia/patologia
2.
Magn Reson Med ; 91(3): 987-1001, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37936313

RESUMO

PURPOSE: This study aims to develop a high-efficiency and high-resolution 3D imaging approach for simultaneous mapping of multiple key tissue parameters for routine brain imaging, including T1 , T2 , proton density (PD), ADC, and fractional anisotropy (FA). The proposed method is intended for pushing routine clinical brain imaging from weighted imaging to quantitative imaging and can also be particularly useful for diffusion-relaxometry studies, which typically suffer from lengthy acquisition time. METHODS: To address challenges associated with diffusion weighting, such as shot-to-shot phase variation and low SNR, we integrated several innovative data acquisition and reconstruction techniques. Specifically, we used M1-compensated diffusion gradients, cardiac gating, and navigators to mitigate phase variations caused by cardiac motion. We also introduced a data-driven pre-pulse gradient to cancel out eddy currents induced by diffusion gradients. Additionally, to enhance image quality within a limited acquisition time, we proposed a data-sharing joint reconstruction approach coupled with a corresponding sequence design. RESULTS: The phantom and in vivo studies indicated that the T1 and T2 values measured by the proposed method are consistent with a conventional MR fingerprinting sequence and the diffusion results (including diffusivity, ADC, and FA) are consistent with the spin-echo EPI DWI sequence. CONCLUSION: The proposed method can achieve whole-brain T1 , T2 , diffusivity, ADC, and FA maps at 1-mm isotropic resolution within 10 min, providing a powerful tool for investigating the microstructural properties of brain tissue, with potential applications in clinical and research settings.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Conceitos Matemáticos
3.
BMC Genomics ; 24(1): 767, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38087190

RESUMO

BACKGROUND: Previous studies on the biomarkers of pathologic myopia choroidal neovascularization (pmCNV) development merely detected limited types of proteins and provide a meagre illustration of the underlying pathways. Hence, a landscape of protein changes in the aqueous humor (AH) of pmCNV patients is lacking. Here, to explore the potential mechanisms and biomarkers of pmCNV, we analyzed the clinical data and protein profile among atrophic (A) lesions, tractional lesions (T) and neovascular (N) lesions in myopic patients based on the ATN grading system for myopic maculopathy (MM). RESULTS: After investigating demographic data of our patients, a correlation was found between A and N lesions (R = 0.5753, P < 0.0001). Accordingly, groups were divided into patients without MM, patients with myopic atrophic maculopathy (MAM), and patients with pmCNV (N2a lesion). In proteomics analysis, the increased protein level of GFAP and complement-associated molecules in AH samples of the 3 groups also indicated that MAM and pmCNV shared similar characteristics. The GO enrichment and KEGG pathway analysis were performed, which mapped that differential expressed proteins mainly engaged in JAK-STAT pathway between the pmCNV group and two controls. Furthermore, we identified several potential biomarkers for pmCNV, including FCN3, GFAP, EGFR, SFRP3, PPP2R1A, SLIT2, and CD248. CONCLUSIONS: Atrophic lesions under pathologic myopic conditions demonstrated similarities to neovascularization development. Potential biomarkers including GFAP were associated with the pathogenesis of pmCNV. In summary, our study provides new insights for further research on pmCNV development.


Assuntos
Neovascularização de Coroide , Degeneração Macular , Miopia , Doenças Retinianas , Humanos , Humor Aquoso/metabolismo , Proteômica , Janus Quinases/metabolismo , Fatores de Transcrição STAT/metabolismo , Transdução de Sinais , Miopia/metabolismo , Doenças Retinianas/metabolismo , Doenças Retinianas/patologia , Neovascularização de Coroide/metabolismo , Neovascularização de Coroide/patologia , Biomarcadores/metabolismo , Antígenos de Neoplasias , Antígenos CD/metabolismo
4.
Small ; 19(31): e2205916, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36494158

RESUMO

Room-temperature phosphorescence has received much attention owing to its potential applications in information encryption and bioelectronics. However, the preparation of full-color single-component-derived phosphorescent materials remains a challenge. Herein, a facile in situ confining strategy is proposed to achieve full-color phosphorescent carbon dots (CDs) through rapid microwave-assisted carbonization of citric acid in NaOH. By tuning the mass ratio of citric acid and NaOH, the obtained CDs exhibit tunable phosphorescence wavelengths ranging from 483 to 635 nm and alterable lifetimes from 58 to 389 ms with a synthesis yield of up to 83.7% (>30 g per synthesis). Theoretical calculations and experimental results confirm that the formation of high-density ionic bonds between cations and CDs leads to efficient afterglow emission via the dissociation of CD arrangement, and the evolution of the aggregation state of CDs results in redshifted phosphorescence. These findings provide a strategy for the synthesis of new insights into achieving and manipulating room-temperature phosphorescent CDs, and prospect their applications in labeling and information encryption.

5.
Magn Reson Med ; 90(1): 250-258, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36932652

RESUMO

PURPOSE: To develop a DWI sequence with multiple readout echo-trains in a single shot (multi-readout DWI) over a reduced FOV, and to demonstrate its ability to achieve high data acquisition efficiency in the study of coupling between diffusion and relaxation in the human prostate. METHODS: The proposed multi-readout DWI sequence plays out multiple EPI readout echo-trains after a Stejskal-Tanner diffusion preparation module. Each EPI readout echo-train corresponded to a distinct effective TE. To maintain a high spatial resolution with a relatively short echo-train for each readout, a 2D RF pulse was used to limit the FOV. Experiments were performed on the prostate of six healthy subjects to acquire a set of images with three b values (0, 500, and 1000 s/mm2 ) and three TEs (63.0, 78.8, and 94.6 ms), producing three ADC maps at different TEs and three T 2 * $$ {T}_2^{\ast } $$ maps at different b values. RESULTS: Multi-readout DWI enabled a threefold acceleration without compromising the spatial resolution when compared with a conventional single-readout sequence. Images with three b values and three TEs were obtained in 3 min 40 s with an adequate SNR (≥ 26.9). The ADC values (1.45 ± 0.13, 1.52 ± 0.14, and 1.58 ± 0.15  µm 2 / ms $$ {\upmu \mathrm{m}}^2/\mathrm{ms} $$ ; P < 0.01) exhibited an increasing trend as TEs increased (63.0 ms, 78.8 ms, and 94.6 ms), whereas T 2 * $$ {T}_2^{\ast } $$ values (74.78 ± 13.21, 63.21 ± 7.84, and 56.61 ± 5.05 ms; P < 0.01) decreases as the b values increased (0, 500, and 1000 s/mm2 ). CONCLUSION: The multi-readout DWI sequence over a reduced FOV provides a time-efficient technique to study the coupling between diffusion and relaxation times.


Assuntos
Imagem de Difusão por Ressonância Magnética , Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos
6.
Phys Rev Lett ; 131(13): 136102, 2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37831989

RESUMO

Transverse spin of surface waves is a universal phenomenon which has recently attracted significant attention in optics and acoustics. It appears in gravity water waves, surface plasmon polaritons, surface acoustic waves, and exhibits remarkable intrinsic spin-momentum locking, which has found useful applications for efficient spin-direction couplers. Here we demonstrate, both theoretically and experimentally, that the transverse spin of surface elastic (Rayleigh) waves has an anomalous sign near the surface, opposite to that in the case of electromagnetic, sound, or water surface waves. This anomalous sign appears due to the hybrid (neither transverse nor longitudinal) nature of elastic surface waves. Furthermore, we show that this sign anomaly can be employed for the selective spin-controlled excitation of symmetric and antisymmetric Lamb modes propagating in opposite directions in an elastic plate. Our results pave the way for spin-controlled manipulation of elastic waves and can be important for a variety of areas, from phononic spin-based devices to seismic waves.

7.
Mol Cell ; 59(6): 931-40, 2015 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-26365380

RESUMO

Glaucoma, a blinding neurodegenerative disease, whose risk factors include elevated intraocular pressure (IOP), age, and genetics, is characterized by accelerated and progressive retinal ganglion cell (RGC) death. Despite decades of research, the mechanism of RGC death in glaucoma is still unknown. Here, we demonstrate that the genetic effect of the SIX6 risk variant (rs33912345, His141Asn) is enhanced by another major POAG risk gene, p16INK4a (cyclin-dependent kinase inhibitor 2A, isoform INK4a). We further show that the upregulation of homozygous SIX6 risk alleles (CC) leads to an increase in p16INK4a expression, with subsequent cellular senescence, as evidenced in a mouse model of elevated IOP and in human POAG eyes. Our data indicate that SIX6 and/or IOP promotes POAG by directly increasing p16INK4a expression, leading to RGC senescence in adult human retinas. Our study provides important insights linking genetic susceptibility to the underlying mechanism of RGC death and provides a unified theory of glaucoma pathogenesis.


Assuntos
Inibidor p16 de Quinase Dependente de Ciclina/genética , Glaucoma de Ângulo Aberto/metabolismo , Proteínas de Homeodomínio/fisiologia , Células Ganglionares da Retina/fisiologia , Transativadores/fisiologia , Sequência de Aminoácidos , Animais , Estudos de Casos e Controles , Morte Celular , Linhagem Celular , Inibidor p16 de Quinase Dependente de Ciclina/metabolismo , Glaucoma de Ângulo Aberto/genética , Glaucoma de Ângulo Aberto/patologia , Humanos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Dados de Sequência Molecular , Mutação de Sentido Incorreto , Regulação para Cima
8.
Appl Opt ; 62(17): 4618-4623, 2023 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-37707159

RESUMO

We present a multilevel synergically controlling wavefront correction method that can apply in a slab laser system. To fully utilize the response frequency and the stroke of actuators of the single deformable mirror (DM), we design a set of multilevel wavefront correction devices to reduce the root-mean square of wavefront aberration before the DM. As the wavefront of slab geometry solid-state lasers mainly consists of fourth and longitudinally distributed aberration, such as 5th, 9th, and 14th orders of Legendre polynomials. We design a precompensating level of the aberration with a slow-drift mirror, fast-steer mirror, one-dimensional adjustable slab-aberration compensator, and beam-shaping system to reduce these orders of wavefront aberration with low spatial resolution and large stroke. As the controlling bandwidth of different devices is diverse, the coupling oscillation between the precompensating level and adaptive optics (AO) level occurs, then we develop the multilevel synergically control to address the coupling. With the precompensating level, the experimental result shows the residual wavefront aberration of the slab laser is compensated well by the AO level effectively within the compensating capability. We clean up a 9.8 kW slab laser system with the beam quality ß of far-field focus spots improved from 17.71 to 2.24 times the diffraction limit.

9.
Pediatr Radiol ; 53(8): 1685-1697, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36884052

RESUMO

BACKGROUND: Accurate segmentation of neonatal brain tissues and structures is crucial for studying normal development and diagnosing early neurodevelopmental disorders. However, there is a lack of an end-to-end pipeline for automated segmentation and imaging analysis of the normal and abnormal neonatal brain. OBJECTIVE: To develop and validate a deep learning-based pipeline for neonatal brain segmentation and analysis of structural magnetic resonance images (MRI). MATERIALS AND METHODS: Two cohorts were enrolled in the study, including cohort 1 (582 neonates from the developing Human Connectome Project) and cohort 2 (37 neonates imaged using a 3.0-tesla MRI scanner in our hospital).We developed a deep leaning-based architecture capable of brain segmentation into 9 tissues and 87 structures. Then, extensive validations were performed for accuracy, effectiveness, robustness and generality of the pipeline. Furthermore, regional volume and cortical surface estimation were measured through in-house bash script implemented in FSL (Oxford Centre for Functional MRI of the Brain Software Library) to ensure reliability of the pipeline. Dice similarity score (DSC), the 95th percentile Hausdorff distance (H95) and intraclass correlation coefficient (ICC) were calculated to assess the quality of our pipeline. Finally, we finetuned and validated our pipeline on 2-dimensional thick-slice MRI in cohorts 1 and 2. RESULTS: The deep learning-based model showed excellent performance for neonatal brain tissue and structural segmentation, with the best DSC and the 95th percentile Hausdorff distance (H95) of 0.96 and 0.99 mm, respectively. In terms of regional volume and cortical surface analysis, our model showed good agreement with ground truth. The ICC values for the regional volume were all above 0.80. Considering the thick-slice image pipeline, the same trend was observed for brain segmentation and analysis. The best DSC and H95 were 0.92 and 3.00 mm, respectively. The regional volumes and surface curvature had ICC values just below 0.80. CONCLUSIONS: We propose an automatic, accurate, stable and reliable pipeline for neonatal brain segmentation and analysis from thin and thick structural MRI. The external validation showed very good reproducibility of the pipeline.


Assuntos
Aprendizado Profundo , Recém-Nascido , Humanos , Reprodutibilidade dos Testes , Neuroimagem , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
10.
Angew Chem Int Ed Engl ; 62(46): e202311533, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37767859

RESUMO

Ribosomally synthesized and post-translationally modified peptides (RiPPs) are a fascinating group of natural products that exhibit diverse structural features and bioactivities. P450-catalyzed RiPPs stand out as a unique but underexplored family. Herein, we introduce a rule-based genome mining strategy that harnesses the intrinsic biosynthetic principles of RiPPs, including the co-occurrence and co-conservation of precursors and P450s and interactions between them, successfully facilitating the identification of diverse P450-catalyzed RiPPs. Intensive BGC characterization revealed four new P450s, KstB, ScnB, MciB, and SgrB, that can catalyze the formation of Trp-Trp-Tyr (one C-C and two C-N bonds), Tyr-Trp (C-C bond), Trp-Trp (C-N bond), and His-His (ether bond) crosslinks, respectively, within three or four residues. KstB, ScnB, and MciB could accept non-native precursors, suggesting they could be promising starting templates for bioengineering to construct macrocycles. Our study highlights the potential of P450s to expand the chemical diversity of strained macrocyclic peptides and the range of biocatalytic tools available for peptide macrocyclization.


Assuntos
Produtos Biológicos , Peptídeos , Peptídeos/química , Ribossomos/metabolismo , Bactérias/metabolismo , Genoma , Sistema Enzimático do Citocromo P-450/metabolismo , Processamento de Proteína Pós-Traducional , Produtos Biológicos/química
11.
Magn Reson Med ; 88(4): 1690-1701, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35666824

RESUMO

PURPOSE: The gradient-echo-train-based Sub-millisecond Periodic Event Encoded Dynamic Imaging (get-SPEEDI) technique provides ultrahigh temporal resolutions (∼0.6 ms) for detecting rapid physiological activities, but its practical adoption can be hampered by long scan times. This study aimed at developing a more efficient variant of get-SPEEDI for reducing the scan time without degrading temporal resolution or image quality. METHODS: The proposed pulse sequence, named k-t get-SPEEDI, accelerated get-SPEEDI acquisition by undersampling the k-space phase-encoding lines semi-randomly. At each time frame, k-space was fully sampled in the central region whereas randomly undersampled in the outer regions. A time-series of images was reconstructed using an algorithm based on the joint partial separability and sparsity constraints. To demonstrate the performance of k-t get-SPEEDI, images of human aortic valve opening and closing were acquired with 0.6-ms temporal resolution and compared with those from conventional get-SPEEDI. RESULTS: k-t get-SPEEDI achieved a 2-fold scan time reduction over the conventional get-SPEEDI (from ∼6 to ∼3 min), while achieving comparable SNRs and contrast-to-noise ratio (CNRs) for visualizing the dynamic process of aortic valve: SNR/CNR ≈$$ \approx $$ 70/38 vs. 73/39 in the k-t and conventional get-SPEEDI scans, respectively. The time courses of aortic valve area also matched well between these two sequences with a correlation coefficient of 0.86. CONCLUSIONS: The k-t get-SPEEDI pulse sequence was able to half the scan time without compromising the image quality and ultrahigh temporal resolution. Additional scan time reduction may also be possible, facilitating in vivo adoptions of SPEEDI techniques.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos
12.
Magn Reson Med ; 87(5): 2372-2379, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34894639

RESUMO

PURPOSE: This study aimed at developing a 3D reduced field-of-view imaging (3D-rFOVI) technique using a 2D radiofrequency (RF) pulse, and demonstrating its ability to achieve isotropic high spatial resolution and reduced image distortion in echo planar imaging (EPI). METHODS: The proposed 3D-rFOVI technique takes advantage of a 2D RF pulse to excite a slab along the conventional slice-selection direction (i.e., z-direction) while limiting the spatial extent along the phase-encoded direction (i.e., y-direction) within the slab. The slab is phase-encoded in both through-slab and in-slab phase-encoded directions. The 3D-rFOVI technique was implemented at 3T in gradient-echo and spin-echo EPI pulse sequences for functional MRI (fMRI) and diffusion-weighted imaging (DWI), respectively. 3D-rFOVI experiments were performed on a phantom and human brain to illustrate image distortion reduction, as well as isotropic high spatial resolution, in comparison with 3D full-FOV imaging. RESULTS: In both the phantom and the human brain, image voxel dislocation was substantially reduced by 3D-rFOVI when compared with full-FOV imaging. In the fMRI experiment with visual stimulation, 3D isotropic spatial resolution of (2 × 2 × 2 mm3 ) was achieved with an adequate signal-to-noise ratio (81.5) and blood oxygen level-dependent (BOLD) contrast (2.5%). In the DWI experiment, diffusion-weighted brain images with an isotropic resolution of (1 × 1 × 1 mm3 ) was obtained without appreciable image distortion. CONCLUSION: This study indicates that 3D-rFOVI is a viable approach to 3D neuroimaging over a zoomed region.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Humanos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Razão Sinal-Ruído
13.
Magn Reson Med ; 87(1): 263-271, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34350601

RESUMO

PURPOSE: To develop an in-plane simultaneous multisegment (IP-SMS) imaging technique using a 2D-RF pulse and to demonstrate its ability to achieve high spatial resolution in EPI while reducing image distortion. METHODS: The proposed IP-SMS technique takes advantage of periodic replicates of the excitation profile of a 2D-RF pulse to simultaneously excite multiple segments within a slice. These segments were acquired over a reduced FOV and separated using a joint GRAPPA reconstruction by leveraging virtual coils that combined the physical coil sensitivity and 2D-RF pulse spatial response. Two excitations were used with complementary spatial response profiles to adequately cover a full FOV, producing a full-FOV image that had the benefits of reduced FOV with high spatial resolution and reduced distortion. The IP-SMS technique was implemented in a diffusion-weighted single-shot EPI sequence. Experimental demonstrations were performed on a phantom and healthy human brain. RESULTS: In the phantom experiment, IP-SMS enabled a four-fold acceleration using an eight-channel coil without causing residual aliasing artifacts. In the human brain experiment, diffusion-weighted images with high in-plane resolution (1 × 1 mm2 ) and substantially reduced image distortion were obtained in all imaging planes in comparison with a commercial diffusion-weighted EPI sequence. The capability of IP-SMS for contiguous whole-brain coverage was also demonstrated. CONCLUSION: The proposed IP-SMS technique can realize the benefits of reduced-FOV imaging while achieving a full-FOV coverage with good image quality and time efficiency.


Assuntos
Algoritmos , Imagem Ecoplanar , Artefatos , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
14.
Phys Rev Lett ; 129(27): 275501, 2022 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-36638293

RESUMO

Distinct from the phononic valley pseudospin, the real physical spin of elastic waves adds a novel tool kit capable of envisaging the valley-spin physics of topological valley phononic crystals from a local viewpoint. Here, we report the observation of local elastic valley spin as well as the hidden elastic spin-valley locking mechanism overlooked before. We demonstrate that the selective one-way routing of valley phonon states along the topological interface can be reversed by imposing the elastic spin metasource at different interface locations with opposite valley-spin correspondence. We unveil the physical mechanism of selective directionality as the elastic spin controlled chiral coupling of valley phonon states, through both analytical theory and experimental measurement of the opposite local elastic spin density at different interface locations for different transport directions. The elastic spin of valley topological edge phonons can be extended to other topological states and offers new tool to explore topological metamaterials.

15.
Eur Radiol ; 32(2): 890-900, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34342693

RESUMO

OBJECTIVES: To evaluate the feasibility of high b-value diffusion-weighted imaging (DWI) for distinguishing non-muscle-invasive bladder cancer (NMIBC) from muscle-invasive bladder cancer (MIBC) and low- from high-grade bladder urothelial carcinoma using a fractional-order calculus (FROC) model as well as a combination of FROC DWI and bi-parametric Vesical Imaging-Reporting and Data System (VI-RADS). METHODS: Fifty-eight participants with bladder urothelial carcinoma were included in this IRB-approved prospective study. Diffusion-weighted images, acquired with 16 b-values (0-3600 s/mm2), were analyzed using the FROC model. Three FROC parameters, D, ß, and µ, were used for delineating NMIBC from MIBC and for tumor grading. A receiver operating characteristic (ROC) analysis was performed based on the individual FROC parameters and their combinations, followed by comparisons with apparent diffusion coefficient (ADC) and bi-parametric VI-RADS based on T2-weighted images and DWI. RESULTS: D and µ were significantly lower in the MIBC group than in the NMIBC group (p = 0.001 for each), and D, ß, and µ all exhibited significantly lower values in the high- than in the low-grade tumors (p ≤ 0.011). The combination of D, ß, and µ produced the highest specificity (85%), accuracy (78%), and the area under the ROC curve (AUC, 0.782) for distinguishing NMIBC and MIBC, and the best sensitivity (89%), specificity (86%), accuracy (88%), and AUC (0.892) for tumor grading, all of which outperformed the ADC. The combination of FROC parameters with bi-parametric VI-RADS improved the AUC from 0.859 to 0.931. CONCLUSIONS: High b-value DWI with a FROC model is useful in distinguishing NMIBC from MIBC and grading bladder tumors. KEY POINTS: • Diffusion parameters derived from a FROC diffusion model may differentiate NMIBC from MIBC and low- from high-grade bladder urothelial carcinomas. • Under the condition of a moderate sample size, higher AUCs were achieved by the FROC parameters D (0.842) and µ (0.857) than ADC (0.804) for bladder tumor grading with p ≤ 0.046. • The combination of the three diffusion parameters from the FROC model can improve the specificity over ADC (85% versus 67%, p = 0.031) for distinguishing NMIBC and MIBC and enhance the performance of bi-parametric VI-RADS.


Assuntos
Cálculos , Carcinoma de Células de Transição , Neoplasias da Bexiga Urinária , Carcinoma de Células de Transição/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Humanos , Gradação de Tumores , Estudos Prospectivos , Curva ROC , Bexiga Urinária , Neoplasias da Bexiga Urinária/diagnóstico por imagem
16.
Eur Radiol ; 32(10): 6992-7003, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35461376

RESUMO

OBJECTIVE: To explore whether magnetic susceptibility value (MSV) and radiomics features of the nigrostriatal system could be used as imaging markers for diagnosing Parkinson's disease (PD) and its related cognitive impairment (CI). METHODS: A total of 104 PD patients and 45 age-sex-matched healthy controls (HCs) underwent quantitative susceptibility mapping (QSM). The former completed Hoehn-Yahr Stage and Montreal Cognitive Assessment (MoCA). The patients were divided into several subgroups according to disease stages, courses, and MoCA scores. The ROI was subdivided into the substantia nigra (SN), head of caudate nucleus (HCN), and putamen. The MSVs and radiomics features were obtained from QSM. The multivariable logistic regression (MLR) and support vector machine (SVM) models were constructed to diagnose PD. The correlations between MSVs, radiomics features, and MoCA scores were evaluated. RESULTS: The MSVs in bilateral SN pars compacta (SNc) of PD patients were higher than those of the HCs (p < 0.001). There were differences in some radiomics features between the two groups (p < 0.05). The MSVs of the right SNc and the radiomics features of the right SN had the highest area under the curve (AUC), respectively. The comprehensive MLR model (0.90) and SVM model (0.95) revealed better classification performance than MSVs (p < 0.05) in diagnosing PD. The MSVs from the HCN were negatively correlated with MoCA scores in PD subgroups. There were correlations between radiomics features and MoCA scores in PD patients. CONCLUSIONS: Radiomics features and MSVs of the nigrostriatal system from QSM could have crucial role in diagnosing PD and assessing CI. KEY POINTS: • The MLR and the SVM models have excellent diagnostic performance in the diagnosis of PD. • A PD diagnostic nomogram, created based on MSV and the radiomics scores of SVM model, is very convenient for clinical use. • The radiomics features of the nigrostriatal system based on QSM help to evaluate the cognitive impairment in PD patients.


Assuntos
Disfunção Cognitiva , Doença de Parkinson , Disfunção Cognitiva/diagnóstico por imagem , Humanos , Ferro , Imageamento por Ressonância Magnética/métodos , Doença de Parkinson/complicações , Doença de Parkinson/diagnóstico por imagem , Substância Negra
17.
Nature ; 531(7594): 323-8, 2016 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-26958831

RESUMO

The repair and regeneration of tissues using endogenous stem cells represents an ultimate goal in regenerative medicine. To our knowledge, human lens regeneration has not yet been demonstrated. Currently, the only treatment for cataracts, the leading cause of blindness worldwide, is to extract the cataractous lens and implant an artificial intraocular lens. However, this procedure poses notable risks of complications. Here we isolate lens epithelial stem/progenitor cells (LECs) in mammals and show that Pax6 and Bmi1 are required for LEC renewal. We design a surgical method of cataract removal that preserves endogenous LECs and achieves functional lens regeneration in rabbits and macaques, as well as in human infants with cataracts. Our method differs conceptually from current practice, as it preserves endogenous LECs and their natural environment maximally, and regenerates lenses with visual function. Our approach demonstrates a novel treatment strategy for cataracts and provides a new paradigm for tissue regeneration using endogenous stem cells.


Assuntos
Catarata/terapia , Cristalino/citologia , Cristalino/fisiologia , Recuperação de Função Fisiológica , Regeneração/fisiologia , Células-Tronco/citologia , Visão Ocular/fisiologia , Animais , Catarata/congênito , Catarata/patologia , Catarata/fisiopatologia , Extração de Catarata , Células Epiteliais/citologia , Células Epiteliais/metabolismo , Proteínas do Olho/metabolismo , Proteínas de Homeodomínio/metabolismo , Homeostase , Humanos , Macaca , Fator de Transcrição PAX6 , Fatores de Transcrição Box Pareados/metabolismo , Complexo Repressor Polycomb 1/metabolismo , Proteínas Proto-Oncogênicas/metabolismo , Proteínas Repressoras/metabolismo , Células-Tronco/metabolismo
18.
J Chem Phys ; 157(11): 114801, 2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36137808

RESUMO

We present our latest advancements of machine-learned potentials (MLPs) based on the neuroevolution potential (NEP) framework introduced in Fan et al. [Phys. Rev. B 104, 104309 (2021)] and their implementation in the open-source package gpumd. We increase the accuracy of NEP models both by improving the radial functions in the atomic-environment descriptor using a linear combination of Chebyshev basis functions and by extending the angular descriptor with some four-body and five-body contributions as in the atomic cluster expansion approach. We also detail our efficient implementation of the NEP approach in graphics processing units as well as our workflow for the construction of NEP models and demonstrate their application in large-scale atomistic simulations. By comparing to state-of-the-art MLPs, we show that the NEP approach not only achieves above-average accuracy but also is far more computationally efficient. These results demonstrate that the gpumd package is a promising tool for solving challenging problems requiring highly accurate, large-scale atomistic simulations. To enable the construction of MLPs using a minimal training set, we propose an active-learning scheme based on the latent space of a pre-trained NEP model. Finally, we introduce three separate Python packages, viz., gpyumd, calorine, and pynep, that enable the integration of gpumd into Python workflows.

19.
Med Sci Monit ; 28: e937193, 2022 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-35543089

RESUMO

This publication has been retracted by the Editor due to the identification of non-original figure images that raise concerns regarding the credibility and originality of the study. Reference: You-Dong Wan, Rui-Xue Zhu, Zhong-Zheng Bian, Xin-Ting Pan. Improvement of Gut Microbiota by Inhibition of P38 Mitogen-Activated Protein Kinase (MAPK) Signaling Pathway in Rats with Severe Acute Pancreatitisy. Med Sci Monit, 2019; 25: 4609-4616. DOI: 10.12659/MSM.914538.

20.
Appl Opt ; 61(30): 8917-8925, 2022 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-36607018

RESUMO

An integrated aberration-compensating module (IACM), consisting mainly of an adjustable slab-aberration compensator, a one-dimensional Shack-Hartmann wavefront sensor, and a data processor, which meet the urgent requirements of correcting the specific wavefront aberrations of a slab laser based on an off-axis stable-unstable resonator, is designed and experimentally demonstrated. Benefits include compactness, robustness, simplicity, automation, and cost-effectiveness. The particular wavefront aberrations of the 9 kW level quasi-continuous-wave Nd:YAG slab laser, which have characteristics of asymmetry, large amplitude and gradient, high spatial frequency, and low temporal frequency, were measured and theoretically analyzed. In the experiment, the wavefront aberrations of the slab laser were corrected by the IACM. At the average output power of 9 kW, the diffraction-limited factor ß was improved from 20.3 times diffraction limit (DL) to 3.6 times DL. The peak-to-valley and root-mean-square values of aberrations were reduced from 9.6 to 0.85 µm and from 2.86 to 0.18 µm within five iterations of the IACM, respectively. Moreover, The IACM is capable of maintaining the compensating surface figure after power-off.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA