Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38925348

RESUMO

OBJECTIVE: Carotid plaque vulnerability is a significant factor in the risk of cardiocerebrovascular events, with intraplaque neovascularization (IPN) being a crucial characteristic of plaque vulnerability. This study investigates the value of ultrasound vector flow imaging (V-flow) for measuring carotid plaque wall shear stress (WSS) in predicting the extent of IPN. METHODS: We enrolled 140 patients into three groups: 53 in the plaque group (72 plaques), 23 in the stenosis group (27 plaques), and 64 in the control group. V-flow was used to measure WSS parameters, including the average WSS (WSS mean) and the maximum WSS (WSS max), across three plaque locations: mid-upstream, maximum thickness, and mid-downstream. Contrast-enhanced ultrasound examination was used in 76 patients to analyze IPN and its correlation with WSS parameters. RESULTS: WSS max in the stenosis group was significantly higher than that in the control and plaque groups at the maximum thickness part (P < .05) and WSS mean in the stenosis group was significantly lower than that in the control group at the mid-upstream and mid-downstream segments (P < .05). WSS mean in the plaque group was significantly lower than that of the control group at all three locations (P < .05). Contrast-enhanced ultrasound examination revealed that plaques with neovascularization enhancement exhibited significantly higher WSS values (P < .05), with a positive correlation between WSS parameters and IPN enhancement grades, particularly WSS max at the thickest part (r = 0.508). Receiver operating characteristic curve analysis of WSS parameters for evaluating IPN showed that the efficacy of WSS max in evaluating IPN was better than that of WSS mean (P < .05), with an area under the curve of 0.7762 and 0.6973 (95% confidence intervals, 0.725-0.822 and 0.642-0.749, respectively). The cut-offs were 4.57 Pa and 1.12 Pa, sensitivities were 74.03% and 63.64%, and specificities were 75.00% and 68.18%. CONCLUSIONS: V-flow effectively measures WSS in carotid plaques. WSS max provides a promising metric for assessing IPN, offering potential insights into plaque characteristics and showing some potential in predicting plaque vulnerability.

2.
Int J Hyperthermia ; 41(1): 2328113, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38964750

RESUMO

PURPOSE: This study aimed to investigate the efficacy and safety of ultrasound-guided percutaneous radiofrequency ablation (RFA) for the treatment of synovial hyperplasia in the knee joints of antigen-induced arthritis (AIA) model rabbits. METHODS: Forty Japanese large-eared white rabbits were divided into AIA and control groups. After successful induction of the AIA model, the knee joints were randomly assigned to RFA and non-RFA groups. The RFA group underwent ultrasound-guided RFA to treat synovial hyperplasia in the knee joint. Dynamic observation of various detection indices was conducted to evaluate the safety and effectiveness of the RFA procedure. RESULTS: Successful synovial ablation was achieved in the RFA group, with no intraoperative or perioperative mortality. Postoperative the circumference of the knee joint reached a peak before decreasing in the third week after surgery. The incidence and diameter of postoperative skin ulcers were not significantly different compared to the non-RFA group (p > .05). Anatomical examination revealed an intact intermuscular fascia around the ablated area in the RFA group. The ablated synovial tissue initially presented as a white mass, which subsequently liquefied into a milky white viscous fluid. Gross articular cartilage was observed, along with liquefied necrosis of the synovium on pathological histology and infiltration of inflammatory cells in the surrounding soft tissue. CONCLUSION: The experimental results demonstrated that ultrasound-guided RFA of the knee in the treatment of synovial hyperplasia in AIA model animals was both effective and safe.


Assuntos
Hiperplasia , Ablação por Radiofrequência , Animais , Coelhos , Ablação por Radiofrequência/métodos , Hiperplasia/cirurgia , Hiperplasia/patologia , Membrana Sinovial/patologia , Membrana Sinovial/diagnóstico por imagem , Ultrassonografia/métodos , Masculino , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA