Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Cardiol Young ; 31(8): 1340-1342, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33682660

RESUMO

Direct hepatic veins-to-hemiazygos connection offers the balanced distribution of hepatic venous blood to both lungs, not requiring anticoagulation. We report a 13-year follow-up after this type of off-pump Fontan completion. Patient's hepatic veins-to-hemiazygos confluence increased with growth to allow for unobstructed flow. This unique technique can be recommended in heterotaxy patients, if atrial hepatic venous drainage and hemiazygos vein are in close proximity.


Assuntos
Técnica de Fontan , Síndrome de Heterotaxia , Veias Pulmonares , Veia Ázigos/diagnóstico por imagem , Veia Ázigos/cirurgia , Veias Hepáticas/cirurgia , Humanos , Veias Pulmonares/cirurgia
2.
Childs Nerv Syst ; 33(4): 703-707, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28032181

RESUMO

INTRODUCTION: Cardiac migration of ventriculoperitoneal (VP) shunts has been reported, with most easily removed or shortened via a cervical incision. We present a review of the literature, highlighting our unique case with significant scarring requiring open, on-pump, cardiac surgery for removal of migrated distal tubing. CASE PRESENTATION: A 7-year-old boy underwent VP shunt insertion for hydrocephalus secondary to intracranial astrocytoma. He presented at age 17 with evidence of right heart strain, associated with the distal shunt catheter proximally migrated into his heart and pulmonary arteries. Due to his delayed presentation, the catheter was knotted and partially immobilized by scar formation, finally requiring open-heart surgery to remove the catheter. CONCLUSIONS: A multi-disciplinary evaluation with endovascular, neurosurgery, and cardiothoracic surgery may be the safest approach, especially in those patients with knotting on preoperative imaging.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Derivação Ventriculoperitoneal/efeitos adversos , Astrocitoma/complicações , Neoplasias Encefálicas/complicações , Criança , Migração de Corpo Estranho/diagnóstico por imagem , Coração , Humanos , Hidrocefalia/etiologia , Hidrocefalia/cirurgia , Imageamento por Ressonância Magnética , Masculino , Procedimentos Neurocirúrgicos , Complicações Pós-Operatórias/diagnóstico por imagem , Tomógrafos Computadorizados
3.
World J Pediatr Congenit Heart Surg ; 15(2): 242-245, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38378189

RESUMO

Reoperative vascular ring surgery is uncommon. Standard redo ipsilateral thoracotomy may present technical challenges and risks. We describe a patient with right aortic arch, aberrant left subclavian artery, and a Kommerell diverticulum in whom previous vascular ring division via left thoracotomy did not relieve dysphagia. Three years after the unsuccessful operation, left subclavian-carotid transposition via supraclavicular incision followed by resection of the Kommerell diverticulum via right thoracotomy with extracorporeal circulation relieved symptoms. Contralateral thoracotomy with extracorporeal circulation provides a safe, alternative approach to redo ipsilateral thoracotomy for resection of a symptomatic Kommerell diverticulum. We review the literature on the incidence, surgical indications, and operative approaches to manage symptoms from a Kommerell diverticulum.


Assuntos
Anormalidades Cardiovasculares , Divertículo , Cardiopatias Congênitas , Anel Vascular , Humanos , Anel Vascular/cirurgia , Aorta Torácica/cirurgia , Toracotomia , Artéria Subclávia/cirurgia , Anormalidades Cardiovasculares/cirurgia , Cardiopatias Congênitas/cirurgia , Circulação Extracorpórea , Divertículo/diagnóstico
4.
J Vasc Surg ; 55(6): 1826-8, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22277688

RESUMO

We present a silicon sheet for temporary wound covering and gradual wound closure after open fasciotomy. Fasciotomy was performed in a total of 70 limbs with compartment syndrome (CS). The main etiology of CS was predominantly vascular. All patients were treated with a silicon sheet to cover the soft tissue defect and gradually reapproximate the skin margins. In 53% of the patients, a delayed final wound closure was achieved after a mean of 11.9 days. This method allows final closure of fasciotomy wounds without scar contractures, marginal necrosis, infection, or significant pain.


Assuntos
Síndromes Compartimentais/cirurgia , Descompressão Cirúrgica/métodos , Fasciotomia , Curativos Oclusivos , Silicones/uso terapêutico , Técnicas de Fechamento de Ferimentos/instrumentação , Cicatrização , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
5.
Heart Surg Forum ; 15(1): E28-33, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22360901

RESUMO

BACKGROUND: Box isolation of the posterior left atrium is one surgical or catheter ablative approach for treating atrial fibrillation (AF). In such cases, incomplete transmurality or recovery of pulmonary vein conduction after the application of various ablative techniques is considered the main reason for the recurrence of postprocedural arrhythmia. The use of solely cut-and-sew box isolation does not have these disadvantages and therefore demonstrates maximum efficacy for this therapeutic approach. METHODS: We treated 15 patients with both an indication for open heart surgery and AF (2 paroxysmal, 6 short persistent [<12 months], and 7 long persistent [>12 months] cases) with a solely cut-and-sew box lesion. These patients were then retrospectively followed up over the long term with respect to the end point of freedom of atrial tachyarrhythmias >30 seconds. RESULTS: The median follow-up duration was 42 months (range, 32-84 months). Five (63%) of 8 patients with preoperative paroxysmal or short persistent AF had no arrhythmia recurrence, whereas arrhythmia recurrence was documented in all 7 patients with preoperative long persistent AF. CONCLUSIONS: Despite reliable transmural isolation with cut-and-sew lesions, we observed long-term arrhythmia recurrence in patients who had preoperative paroxysmal or short persistent AF, suggesting that therapy approaches that are more complex than box isolation might be needed for selected patients to achieve long-term stable sinus rhythm, despite the initially paroxysmal or short persistent character of the arrhythmia. A high rate of recurrence in patients with severe structural heart disease and preoperative long persistent AF might indicate that, in general, isolation of the left posterior atrium alone is not an adequate therapeutic approach for these patients.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Idoso , Fibrilação Atrial/patologia , Procedimentos Cirúrgicos Cardíacos/instrumentação , Doença Crônica , Feminino , Átrios do Coração/patologia , Humanos , Masculino , Recidiva , Estudos Retrospectivos , Fatores de Tempo
6.
Cardiol Young ; 22(1): 92-5, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21729510

RESUMO

Neonatal interventions for critical aortic coarctation may be associated with considerable morbidity and mortality if the patient is extremely premature. We report the successful treatment of critical coarctation in a 25-week, 740-gram infant using initial clipping of the duct until continued prostaglandin E1 infusion delayed end-to-end anastomosis 7 weeks later.


Assuntos
Coartação Aórtica/terapia , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Estado Terminal , Humanos , Recém-Nascido
7.
Circulation ; 122(11 Suppl): S216-23, 2010 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-20837916

RESUMO

BACKGROUND: The purpose of the study is to report major cardiac and cerebrovascular events after the Ross procedure in the large adult and pediatric population of the German-Dutch Ross registry. These data could provide an additional basis for discussions among physicians and a source of information for patients. METHODS AND RESULTS: One thousand six hundred twenty patients (1420 adults; 1211 male; mean age, 39.2±16.2 years) underwent a Ross procedure between 1988 and 2008. Follow-up was performed on an annual basis (median, 6.2 years; 10 747 patient-years). Early and late mortality were 1.2% (n=19) and 3.6% (n=58; 0.54%/patient-year), respectively. Ninety-three patients underwent 99 reinterventions on the autograft (0.92%/patient-year); 78 reinterventions in 63 patients on the pulmonary conduit were performed (0.73%/patient-year). Freedom from autograft or pulmonary conduit reoperation was 98.2%, 95.1%, and 89% at 1, 5, and 10 years, respectively. Preoperative aortic regurgitation and the root replacement technique without surgical autograft reinforcement were associated with a greater hazard for autograft reoperation. Major internal or external bleeding occurred in 17 (0.15%/patient-year), and a total of 38 patients had composite end point of thrombosis, embolism, or bleeding (0.35%/patient-year). Late endocarditis with medical (n=16) or surgical treatment (n=29) was observed in 38 patients (0.38%/patient-year). Freedom from any valve-related event was 94.9% at 1 year, 90.7% at 5 years, and 82.5% at 10 years. CONCLUSIONS: Although longer follow-up of patients who undergo Ross operation is needed, the present series confirms that the autograft procedure is a valid option to treat aortic valve disease in selected patients. The nonreinforced full root technique and preoperative aortic regurgitation are predictors for autograft failure and warrant further consideration. Clinical Trial Registration-URL: http://www.clinicaltrials.gov. Unique identifier: NCT00708409.


Assuntos
Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Complicações Pós-Operatórias/mortalidade , Sistema de Registros , Adulto , Endocardite/etiologia , Endocardite/mortalidade , Feminino , Seguimentos , Alemanha , Hemorragia/etiologia , Hemorragia/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Complicações Pós-Operatórias/cirurgia , Transplante Autólogo
8.
Mol Med ; 17(11-12): 1213-22, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21792480

RESUMO

New drug-eluting stent (DES) methods have recently been demonstrated to improve outcomes of intravascular interventions. A novel technique is the design of gene-silencing stents that elute specific small-interfering RNAs (siRNAs) for better vascular wall regeneration. Although siRNAs used to alter gene expression have surpassed expectations in in vitro experiments, the functional and local delivery of siRNAs is still the major obstacle for the in vivo application of RNA interference. In this preliminary in vitro study we investigated a surface-immobilized siRNA delivery technique that would be readily adaptable for local intravascular applications in vivo. The transfection potency of gelatin coatings consisting of a specific siRNA complexed with polyethylenimine (PEI) was examined in primary human endothelial cells by flow cytometry and quantitative real-time polymerase chain reaction. Several media conditions, such as the presence or absence of serum during cultivation, were investigated. Furthermore, different siRNA and PEI amounts, as well as nitrogen/phosphate ratios, were tested for their transfection efficiency. Gelatin coatings consisting of PEI and siRNA against an exemplary endothelial adhesion molecule receptor achieved a significant knockdown of around 70%. The transfection efficiency of the coatings was not influenced by the presence of serum. The results of this preliminary study support the expectation that this novel coating may be favorable for local in vivo gene silencing (for example, when immobilized on stents or balloons for percutanous transluminal coronary angioplasty). However, further animal experiments are needed to confirm the translation into clinical practice. This intriguing technology leads the way to more sophisticated and individualized coatings for the post-DES era, toward silencing of genes involved in the pathway of intimal hyperplasia.


Assuntos
Prótese Vascular , Stents Farmacológicos , Inativação Gênica , RNA Interferente Pequeno/metabolismo , Células Cultivadas , Materiais Revestidos Biocompatíveis/farmacologia , Meios de Cultura , Selectina E/metabolismo , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo , Corantes Fluorescentes , Técnicas de Silenciamento de Genes , Inativação Gênica/efeitos dos fármacos , Humanos , Polietilenoimina/química , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Reação em Cadeia da Polimerase em Tempo Real , Soro/metabolismo , Transfecção
9.
J Mater Sci Mater Med ; 22(6): 1521-8, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21604053

RESUMO

Subacute stent thrombosis, caused by undesired interactions between blood and the stent surface, is a major concern in the first few weeks following coronary artery stent implantation. The aim of this study was to establish a novel in vitro model for hemocompatibility testing of coronary artery stents according to ISO 10993-4. The model consists of a modified Chandler-Loop design with closed heparin-coated PVC Loops and a thermostated water bath. The tests were performed with anticoagulated human whole blood. After incubation in the loop, blood was analyzed for coagulation and inflammatory activation markers (TAT, ß-TG, sP-selectin, SC5b-9 and PMN-elastase). Three different stent types with varying thrombogenicity were tested; statistically significant differences were found between the three stent types in measures of coagulation and platelet activation. The new Chandler-Loop model can be used as an alternative to animal and current in vitro models, especially for the determination of early events after stent implantation.


Assuntos
Prótese Vascular , Teste de Materiais/métodos , Stents , Anticoagulantes/administração & dosagem , Contagem de Células Sanguíneas , Células Sanguíneas/citologia , Células Sanguíneas/efeitos dos fármacos , Células Sanguíneas/fisiologia , Coagulação Sanguínea/efeitos dos fármacos , Coagulação Sanguínea/fisiologia , Plaquetas/efeitos dos fármacos , Plaquetas/fisiologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Stents Farmacológicos , Heparina/administração & dosagem , Heparina/farmacologia , Humanos , Técnicas In Vitro , Inflamação/metabolismo , Masculino , Teste de Materiais/normas , Microscopia Eletrônica de Varredura , Modelos Biológicos , Ativação Plaquetária/efeitos dos fármacos , Ativação Plaquetária/fisiologia , Padrões de Referência
10.
Sensors (Basel) ; 11(5): 5253-69, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22163899

RESUMO

The reliability of implantable blood sensors is often hampered by unspecific adsorption of plasma proteins and blood cells. This not only leads to a loss of sensor signal over time, but can also result in undesired host vs. graft reactions. Within this study we evaluated the hemocompatibility of isocyanate conjugated star shaped polytheylene oxide-polypropylene oxide co-polymers NCO-sP(EO-stat-PO) when applied to gold surfaces as an auspicious coating material for gold sputtered blood contacting sensors. Quartz crystal microbalance (QCM) sensors were coated with ultrathin NCO-sP(EO-stat-PO) films and compared with uncoated gold sensors. Protein resistance was assessed by QCM measurements with fibrinogen solution and platelet poor plasma (PPP), followed by quantification of fibrinogen adsorption. Hemocompatibility was tested by incubation with human platelet rich plasma (PRP). Thrombin antithrombin-III complex (TAT), ß-thromboglobulin (ß-TG) and platelet factor 4 (PF4) were used as coagulation activation markers. Furthermore, scanning electron microscopy (SEM) was used to visualize platelet adhesion to the sensor surfaces. Compared to uncoated gold sensors, NCO-sP(EO-stat-PO) coated sensors revealed significant better resistance against protein adsorption, lower TAT generation and a lower amount of adherent platelets. Moreover, coating with ultrathin NCO-sP(EO-stat-PO) films creates a cell resistant hemocompatible surface on gold that increases the chance of prolonged sensor functionality and can easily be modified with specific receptor molecules.


Assuntos
Técnicas Biossensoriais/instrumentação , Ouro/química , Técnicas de Microbalança de Cristal de Quartzo/instrumentação , Adsorção , Técnicas Biossensoriais/métodos , Fibrinogênio/química , Humanos , Plasma/química , Técnicas de Microbalança de Cristal de Quartzo/métodos
11.
Circulation ; 120(11 Suppl): S146-54, 2009 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-19752360

RESUMO

BACKGROUND: Autograft reinforcement interventions (R) during the Ross procedure are intended to preserve autograft function and improve durability. The aim of this study is to evaluate this hypothesis. METHODS AND RESULTS: 1335 adult patients (mean age:43.5+/-12.0 years) underwent a Ross procedure (subcoronary, SC, n=637; root replacement, Root, n=698). 592 patients received R of the annulus, sinotubular junction, or both. Regular clinical and echocardiographic follow-up was performed (mean:6.09+/-3.97, range:0.01 to 19.2 years). Longitudinal assessment of autograft function with time was performed using multilevel modeling techniques. The Root without R (Root-R) group was associated with a 6x increased reoperation rate compared to Root with R (Root+R), SC with R (SC+R), and without R (SC-R; 12.9% versus 2.3% versus 2.5%.versus 2.6%, respectively; P<0.001). SC and Root groups had similar rate of aortic regurgitation (AR) development over time. Root+R patients had no progression of AR, whereas Root-R had 6 times higher AR development compared to Root+R. In SC, R had no remarkable effect on the annual AR progression. The SC technique was associated with lower rates of autograft dilatation at all levels of the aortic root compared to the Root techniques. R did not influence autograft dilatation rates in the Root group. CONCLUSIONS: For the time period of the study surgical autograft stabilization techniques preserve autograft function and result in significantly lower reoperation rates. The nonreinforced Root was associated with significant adverse outcome. Therefore, surgical stabilization of the autograft is advisable to preserve long-term autograft function, especially in the Root Ross procedure.


Assuntos
Valva Aórtica/transplante , Procedimentos Cirúrgicos Cardíacos/métodos , Adulto , Insuficiência da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Sistema de Registros , Reoperação , Transplante Autólogo
12.
Analyst ; 135(11): 2930-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20877907

RESUMO

The objective of this study was to establish a new test system for the monitoring of platelet aggregation during extracorporeal circulation (ECC) procedures. Even though extensive progress has been made in improving the haemocompatibility of extracorporeal circulation devices, activation of blood coagulation, blood platelets and inflammatory responses are still undesired outcomes of cardiopulmonary bypass. This study deals with an approach towards a platelet aggregation measuring system using a newly developed quartz crystal microbalance (QCM) system. Since QCM is a rarely used technique in the field of blood analytics, the challenge was to transfer the well established methods of aggregometry to the new test system. In a QCM system, either bare gold or fibrinogen-coated sensors were incubated with ADP or arachidonic acid (AA) stimulated platelet rich plasma. For negative controls the GPIIb/IIIa inhibitory antibody abciximab (Reopro®) was used as an inhibitor of platelet aggregation. During incubation, the frequency shifts of the sensors were recorded. The results gained from the QCM system were compared to results gained by optical platelet aggregometry (born aggregometry). For additional visualization of platelet adhesion to the sensor surfaces, fluorescent microscopy and scanning electron microscopy were used. The QCM sensor was able to detect platelet aggregation in both uncoated and fibrinogen coated sensors. The measuring curves of aggregation measurements and controls were clearly distinguishable from each other in terms of frequency shifts and kinetics. For aggregation measurements and inhibited controls the therapeutic diagnosis of platelet function is identical between aggregometer and QCM data. In future, QCM based measuring devices may become an alternative to established point of care methods for rapid bedside testing of platelet aggregation.


Assuntos
Técnicas de Microbalança de Cristal de Quartzo/instrumentação , Técnicas de Microbalança de Cristal de Quartzo/métodos , Abciximab , Anticorpos Monoclonais/farmacologia , Fibrinogênio/química , Ouro/química , Humanos , Fragmentos Fab das Imunoglobulinas/farmacologia , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Agregação Plaquetária/efeitos dos fármacos , Contagem de Plaquetas , Testes de Função Plaquetária , Valores de Referência , Sensibilidade e Especificidade
13.
Heart Surg Forum ; 13(4): E218-22, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20719722

RESUMO

BACKGROUND: Cardioplegia and reperfusion of the myocardium may be associated with cardiomyocyte apoptosis and subsequent myocardial injury. To establish a pharmacologic strategy for the prevention of these events, this study aimed to verify the reliability of our human cardiac model and to evaluate the antiapoptotic properties of the nonselective beta-blocker carvedilol during simulated cardioplegia and reperfusion ex vivo. METHODS: Cardiac biopsies were retrieved before induction of cardiopulmonary bypass from the auricle of the right atrium of patients undergoing elective coronary artery bypass grafting. Biopsies were exposed to ex vivo conditions of varying periods of cardioplegia/reperfusion (30/10 minutes, 60/20 minutes, 120/40 minutes). Group I was the untreated control (n = 15), group II was the treated control (cardioplegia/reperfusion, n = 15), and group III was the experimental group (cardioplegia/reperfusion plus carvedilol, n = 15). Immunostaining for antibodies to activated caspase 3 and poly(ADP-ribose) polymerase 1 (PARP-1) cleavage was used to detect apoptosis. RESULTS: The percentage of apoptotic cardiomyocytes was significantly lower (P < .05) in group I than in group II, revealing a time-dependent increase. In group III, carvedilol treatment suppressed apoptosis significantly (P < .05). CONCLUSION: Carvedilol significantly suppresses apoptosis in our ex vivo setting. This finding warrants further studies to evaluate the potential beneficial effects of carvedilol in suppressing ischemia/reperfusion injury in clinical settings.


Assuntos
Antagonistas Adrenérgicos beta/farmacologia , Apoptose/efeitos dos fármacos , Carbazóis/farmacologia , Coração/fisiopatologia , Miócitos Cardíacos/efeitos dos fármacos , Propanolaminas/farmacologia , Idoso , Anticorpos/análise , Carvedilol , Caspase 3/imunologia , Caspase 3/metabolismo , Ativação Enzimática , Desenho de Equipamento , Feminino , Coração/efeitos dos fármacos , Parada Cardíaca Induzida , Humanos , Imuno-Histoquímica/métodos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Reperfusão Miocárdica , Peptídeo Hidrolases/farmacologia , Perfusão/instrumentação , Projetos Piloto , Poli(ADP-Ribose) Polimerase-1 , Poli(ADP-Ribose) Polimerases/efeitos dos fármacos , Poli(ADP-Ribose) Polimerases/imunologia , Coloração e Rotulagem
14.
Pacing Clin Electrophysiol ; 32(8): 1099-100, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19659633

RESUMO

Unintended internal suturing of central venous lines or pulmonary artery catheters in the superior caval vein or the right atrium following cardiac surgery remains a rare but troublesome complication. The line is normally entangled in safety or hemostasis sutures after the removal of the superior caval cannulation. If mild tension is unsuccessful, the patient normally undergoes resternotomy. The objective of this brief communication is to describe of a simple and safe removal method using a transvenous rotational cutting device to divide the hemostasis suture. In order to avoid complicating bleeding, a time delay between initial placement and removal is highly recommended. For extraction, a fully equipped cardiovascular operating room with central venous and arterial lines, attached defibrillator pads, transesophageal echo monitoring, fluoroscopy, and a surgical team, including a heart and lung machine and a perfusionist standby, is mandatory.


Assuntos
Procedimentos Cirúrgicos Cardiovasculares , Cateterismo Venoso Central/instrumentação , Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Idoso , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos
15.
Echocardiography ; 26(5): 508-12, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19452606

RESUMO

OBJECTIVES: Hydrotin-C is a bacterial cellulose consisting of 90% of physiological solution. The cellulose pad is smooth and elastic and cannot be torn, and is therefore suitable for use on any local skin condition. The aim of this study was to evaluate the image quality (IQ) and transducer pressure of Hydrotin-C-Pads as a solid coupling agent compared with standard coupling gel. METHODS: To date, transthoracic echocardiography has been performed in 51 patients (ongoing study) using standard coupling gel and Hydrotin-C-Pads. The IQ was categorized as follows: 1 = excellent, 2 = good, 3 = poor, 4 = inadequate. All patients were questioned about the transducer pressure, which was categorized as: 0 = less, 1 = equal, 2 = more. The body mass index (BMI) was documented for all patients. RESULTS: The IQ was very good with Hydrotin-C-Pads. The IQ was better in 84% of all patients. In patients with a BMI of over 25 and in patients with a BMI of over 30, Hydrotin-C-Pads was also better compared with standard gel. The transducer pressure was lower in 33 patients. CONCLUSIONS: Hydrotin-C-Pads can be used as a solid ultrasonic coupling agent. Because of the consistent thickness of the coupling zone, the IQ seems to be better for Hydrotin-C-Pads compared with standard coupling gel. The transducer presser is lower, and these pads are easy to apply and are reusable and reduce the burden of clean-up after treatment.


Assuntos
Curativos Hidrocoloides , Celulose/administração & dosagem , Aumento da Imagem/métodos , Pneumopatias/diagnóstico por imagem , Ultrassonografia/métodos , Idoso , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Molecules ; 15(1): 1-11, 2009 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-20110867

RESUMO

The generation of single-stranded DNA (ssDNA) molecules plays a key role in the SELEX (Systematic Evolution of Ligands by EXponential enrichment) combinatorial chemistry process and numerous molecular biology techniques and applications, such as DNA sequencing, single-nucleotide polymorphism (SNP) analysis, DNA chips, DNA single-strand conformation polymorphism (SSCP) analysis and many other techniques. The purity and yield of ssDNA can affect the success of each application. This study compares the two ssDNA production methods, the strand separation by streptavidin-coated magnetic beads and alkaline denaturation and the lambda exonuclease digestion, in regard to the purity of generated ssDNA and the efficiency. Here, we demonstrate the considerable benefits of ssDNA production by lambda exonuclease digestion for in vitro selection of DNA aptamers. We believe that the generation of ssDNA aptamers using this method will greatly improve the success rate of SELEX experiments concerning the recovery of target-specific aptamers.


Assuntos
DNA de Cadeia Simples/biossíntese , Exodesoxirribonucleases/metabolismo , Técnica de Seleção de Aptâmeros/métodos , Biotinilação/efeitos dos fármacos , Western Blotting , Magnetismo , Microesferas , Desnaturação de Ácido Nucleico/efeitos dos fármacos , Fosforilação/efeitos dos fármacos , Hidróxido de Sódio/farmacologia , Estreptavidina/metabolismo , Fatores de Tempo
17.
Circulation ; 116(11 Suppl): I251-8, 2007 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-17846313

RESUMO

BACKGROUND: Autograft regurgitation and root dilatation after the Ross procedure is of major concern. We reviewed data from the German Ross Registry to document the development of autograft regurgitation and root dilatation with time and also to compare 2 different techniques of autograft implantation. METHODS AND RESULTS: Between 1990 and 2006 1014 patients (786 men, 228 women; mean age 41.2+/-15.3 years) underwent the Ross procedure using 2 different implantation techniques (subcoronary, n=521; root replacement, n=493). Clinical and serial echocardiographic follow up was performed preoperatively and thereafter annually (mean follow up 4.41+/-3.11 years, median 3.93 years, range 0 to 16.04 years; 5012 patient-years). For statistical analysis of serial echocardiograms, a hierarchical multilevel modeling technique was applied. Eight early and 28 late deaths were observed. Pulmonary autograft reoperations were required in 35 patients. Initial autograft regurgitation grade was 0.49 (root replacement 0.73, subcoronary 0.38) with an annual increase of grade 0.034 (root replacement 0.0259, subcoronary 0.0231). Annulus and sinus dimensions did not exhibit an essential increase over time in both techniques, whereas sinotubular junction diameter increased essentially by 0.5 mm per year in patients with root replacement. Patients with the subcoronary implantation technique showed nearly unchanged dimensions. Bicuspid aortic valve morphology did not have any consistent impact on root dimensions with time irrespective of the performed surgical technique. CONCLUSIONS: The present Ross series from the German Ross Registry showed favorable clinical and hemodynamic results. Development of autograft regurgitation for both techniques was small and the annual progression thereof is currently not substantial. Use of the subcoronary technique and aortic root interventions with stabilizing measures in root replacement patients seem to prevent autograft regurgitation and dilatation of the aortic root within the timeframe studied.


Assuntos
Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/transplante , Sistema de Registros , Adulto , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Transplante Autólogo
18.
Thromb Haemost ; 99(3): 609-15, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18327411

RESUMO

Extracorporeal circulation (ECC) is used in cardiac surgery for cardiopulmonary bypass as well as in ventricular assist devices and for extracorporeal membrane oxygenation. Blood contact with the artificial surface and shear stress of ECC activates platelets and leukocytes resulting in a coagulopathy and proinflammatory events. Blockers of the platelet glycoprotein (GP) IIb/IIIa (CD41/CD61) can protect platelet function during ECC, a phenomenon called "platelet anaesthesia", but may be involved in post-ECC bleeding. We hypothesized that the new selective phosphoinositide 3-kinase p110beta inhibitor TGX-221 that inhibits shear-induced platelet activation without prolonging the bleeding time in vivo may also protect platelet function during ECC. Heparinized blood of healthy volunteers (n = 6) was treated in vitro with either the GP IIb/IIIa blocker tirofiban, TGX-221 or as control and circulated in an ECC model. Before and after 30 minutes circulation CD41 expression on the ECC-tubing as measure for platelet-ECC binding and generation of the platelet activation marker beta-thromboglobulin were determined using ELISA. Platelet aggregation and platelet-granulocyte binding were analysed in flow cytometry. After log-transforming the data statistical evaluation was performed using multifactor ANOVA in combination with Tukey's HSD test (global alpha = 5%). Tirofiban and TGX-221 inhibited platelet-ECC interaction, platelet aggregation and platelet-granulocyte binding. Tirofiban also inhibited ECC-induced beta-thromboglobulin release. The observed inhibition of platelet-ECC interaction and platelet activation by tirofiban contributes to explain the mechanism of "platelet anaesthesia". TGX-221 represents a promising alternative to GP IIb/IIIa blockade and should be further investigated for use during ECC in vivo.


Assuntos
Plaquetas/efeitos dos fármacos , Circulação Extracorpórea/efeitos adversos , Morfolinas/farmacologia , Inibidores de Fosfoinositídeo-3 Quinase , Ativação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/farmacologia , Inibidores de Proteínas Quinases/farmacologia , Pirimidinonas/farmacologia , Antitrombina III/metabolismo , Plaquetas/enzimologia , Plaquetas/ultraestrutura , Classe I de Fosfatidilinositol 3-Quinases , Circulação Extracorpórea/instrumentação , Fibrinogênio/metabolismo , Granulócitos/efeitos dos fármacos , Granulócitos/metabolismo , Hemoglobinas/metabolismo , Humanos , Masculino , Microscopia Eletrônica de Varredura , Peptídeo Hidrolases/metabolismo , Fosfatidilinositol 3-Quinases/metabolismo , Adesividade Plaquetária/efeitos dos fármacos , Agregação Plaquetária/efeitos dos fármacos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/metabolismo , Glicoproteína IIb da Membrana de Plaquetas/metabolismo , Projetos de Pesquisa , Estresse Mecânico , Fatores de Tempo , Tirofibana , Tirosina/análogos & derivados , Tirosina/farmacologia , beta-Tromboglobulina/metabolismo
19.
Biomaterials ; 29(29): 3936-45, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18640715

RESUMO

For years intensive research has been done to endothelialise vascular prostheses with autologous endothelial cells before implantation in patients. However, this procedure is extremely time-, labor- and cost-intensive and can be realized only in very few clinical cases. The discovery of circulating endothelial progenitor cells (EPCs) in 1997 brought new perspectives for the endothelialisation of blood contacting materials. Coating of synthetic graft surfaces with capture molecules for circulating EPCs mimics a pro-homing substrate for fishing out EPCs directly from the bloodstream after implantation. These cells with high proliferation potential can cover the graft with non-thrombogenic endothelium which maintains optimal haemostasis and minimize the risk of restenosis. In this review, different concepts are discussed to capture circulating EPCs on synthetic vascular grafts after implantation. We hypothesize that in vivo self-endothelialisation of blood contacting materials by homing factor-mimetic capture molecules for EPCs may bring revolutionary new perspectives towards future clinical application of stem cell and tissue engineering strategies.


Assuntos
Sangue , Células Endoteliais , Mimetismo Molecular , Células-Tronco , Engenharia Tecidual/métodos , Antígenos CD34/metabolismo , Aptâmeros de Nucleotídeos/química , Aptâmeros de Nucleotídeos/metabolismo , Quimiotaxia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/metabolismo , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Humanos , Magnetismo , Teste de Materiais , Oligopeptídeos/metabolismo , Células-Tronco/citologia , Células-Tronco/metabolismo , Propriedades de Superfície
20.
Thromb Res ; 122(3): 383-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18304613

RESUMO

INTRODUCTION: Blood contact with artificial surfaces of extracorporeal circulation (ECC) and hypothermia as applied in cardiac surgery cause platelet dysfunction possibly followed by bleeding complications. "Platelet anaesthesia" is a pharmacological strategy to protect platelets against ECC-induced damage using a GP IIb/IIIa blocker, which should be short acting to achieve maximal therapy control thereby avoiding post-ECC haemorrhage. However, GP IIb/IIIa blockers can paradoxically induce platelet activation, which may limit their efficiency as anti-platelet drugs. This in-vitro study investigated potentially platelet-activating effects of short-acting GP IIb/IIIa blockers during normothermic and hypothermic ECC. MATERIALS AND METHODS: Control (untreated) and treated (using either FK633 [half-life: 0.52 h], tirofiban [half-life: 1.5-2 h], or eptifibatide [half-life: 1.5 h]) heparinized blood was circulated in an ECC-model at normothermia (37 degrees C) and hypothermia (18 degrees C). Percentages of platelet aggregates and P-selectin-expressing (activated) platelets, platelet-counts and Thrombin-Antithrombin (TAT) complex formation were determined before (baseline) and after ECC. Statistical analysis was performed using multifactorial ANOVA after log-transforming the data. RESULTS: GP IIb/IIIa blockade inhibited ECC-induced platelet aggregation and platelet loss and decreased P-selectin expression at normothermia. During hypothermic ECC P-selectin was decreased by tirofiban but augmented by FK633 and eptifibatide. TAT formation was only decreased by FK633. CONCLUSIONS: Especially regarding its ultra-short half-life FK633 has the best properties for platelet protection during normothermic ECC. However, at hypothermia FK633 and eptifibatide induce platelet activation. In relation with "platelet anaesthesia" possible hypothermia-associated prothrombotic side effects of GP IIb/IIIa blockers should be considered.


Assuntos
Plaquetas/efeitos dos fármacos , Dipeptídeos/farmacologia , Circulação Extracorpórea , Hipotermia Induzida , Selectina-P/metabolismo , Ativação Plaquetária/efeitos dos fármacos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Difosfato de Adenosina/farmacologia , Antitrombina III/metabolismo , Plaquetas/fisiologia , Citometria de Fluxo , Humanos , Masculino , Peptídeo Hidrolases/metabolismo , Ativação Plaquetária/fisiologia , Contagem de Plaquetas , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA