Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38864969

RESUMO

PURPOSE: Coronary artery bypass grafting (CABG) on cardiopulmonary bypass (CPB) is associated with myocardial ischemia-reperfusion injury (IRI), which may limit the benefit of the surgery. Both experimental and clinical studies suggest that Intralipid, a lipid emulsion commonly used for parenteral nutrition, can limit myocardial IRI. We therefore aimed to investigate whether Intralipid administered at reperfusion can reduce myocardial IRI in patients undergoing CABG on CPB. METHODS: We conducted a randomized, double-blind, pilot trial in which 29 adult patients scheduled for CABG were randomly assigned (on a 1:1 basis) to receive either 1.5 ml/kg Intralipid 20% or Ringer's Lactate 3 min before aortic cross unclamping. The primary endpoint was the 72-h area under the curve (AUC) for troponin I. RESULTS: Of the 29 patients randomized, 26 were included in the study (two withdrew consent and one was excluded before surgery). The 72-h AUC for troponin I did not significantly differ between the control and Intralipid group (546437 ± 205518 versus 487561 ± 115724 arbitrary units, respectively; P = 0.804). Other outcomes (including 72-h AUC for CK-MB, C-reactive protein, need for defibrillation, time to extubation, length of ICU and hospital stay, and serious adverse events) were similar between the two groups. CONCLUSION: In patients undergoing CABG on CPB, Intralipid did not limit myocardial IRI compared to placebo. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02807727 (registration date: 16 June 2016).

2.
Perfusion ; 36(4): 432-434, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32815778

RESUMO

Prolonged normothermic cardiac arrest is associated with a high incidence of neurological morbidity and mortality. Whole body temperature-controlled perfusion has been applied to limit reperfusion injury and minimize ischemia. We describe the full recovery of a patient after the application of rapid hypothermia following an intraoperative aortic rupture with ten minutes of absent cerebral blood flow.


Assuntos
Parada Cardíaca , Hipotermia Induzida , Encéfalo , Circulação Cerebrovascular , Parada Cardíaca/terapia , Humanos , Perfusão
3.
Artif Organs ; 43(10): E282-E293, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31140632

RESUMO

Cardiac implants may have a strong influence on the hemodynamics of the circulatory system. In this study, we aimed at investigating the impact of transcatheter aortic valve implantation (TAVI) devices on blood flow patterns that develop in the ascending aorta under physiological flow conditions in vitro. For this purpose, a noninvasive optical measurement tool, three-dimensional particle tracking velocimetry (3D-PTV), was used in a realistic compliant silicone aortic model. The performance and the influence of two TAVIs and one surgical valve on the aortic flow were investigated. Our results showed that valve design and materials may have a distinct influence on relevant hemodynamic properties, namely kinetic energy, production of turbulence, and shear stresses in the ascending aorta. All properties varied considerably between the different valve models. We found that the total aortic regurgitation composed of the closing volume, transvalvular and paravalvular leakages varied for the three valves investigated. Furthermore, peak mean kinetic energy (MKE) ranged from 61 to 116 J/m3 , whereas peak turbulent kinetic energy (TKE) ranged from 23 to 36 J/m3 . The analysis of shear showed that all the three studied devices had minimal overall risk for thrombus formation. We conclude that the characteristics and material designs of TAVI devices have strong influences on the hemodynamics in the ascending aorta.


Assuntos
Aorta/fisiologia , Próteses Valvulares Cardíacas , Hemodinâmica , Substituição da Valva Aórtica Transcateter , Aorta/anatomia & histologia , Aorta/diagnóstico por imagem , Valva Aórtica/cirurgia , Hemorreologia , Humanos , Modelos Anatômicos , Imagem Óptica , Desenho de Prótese , Reologia
4.
Eur Heart J ; 36(18): 1078-89, 2015 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-25736252

RESUMO

Valvular heart disease (VHD) in pregnant women, whether due to congenital or acquired aetiologies, poses a challenge to clinicians and their patients. Significant valve disease, which can affect a single valve or several valves, increases the risk of pregnancy to the mother and foetus and requires a careful preconception risk assessment and, subsequently during pregnancy, specialized care to minimize maternal and foetal morbidity and mortality. The goal of this paper is to provide a guide to risk assessment and to give an overview of the optimal cardiac and obstetric management, including surgical intervention, taking into consideration the resources available in higher and lower-to-middle income countries. This manuscript provides a practical approach and is not replacing comprehensive guidelines on the management of VHD or cardiovascular disease in pregnancy. It focuses on common valvular diseases and does not cover the large variety of aortic disease with and without valve disease or complex congenital heart disease in detail.


Assuntos
Doenças das Valvas Cardíacas/terapia , Complicações Cardiovasculares na Gravidez/terapia , Cuidado Pré-Natal/métodos , Cardiopatia Reumática/terapia , Valvuloplastia com Balão/métodos , Parto Obstétrico/métodos , Feminino , Oclusão de Enxerto Vascular/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Gravidez , Diagnóstico Pré-Natal/métodos , Desenho de Prótese , Medição de Risco/métodos
6.
Front Cardiovasc Med ; 11: 1347838, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38404722

RESUMO

The majority of patients requiring heart valve replacement in low- to middle-income countries (LMICs) need it for rheumatic heart disease (RHD). While the young age of such patients largely prescribes replacement with mechanical prostheses, reliable anticoagulation management is often unattainable under the prevailing socioeconomic circumstances. Cases of patients with clotted valves presenting for emergency surgery as a consequence of poor adherence to anticoagulation control are frequent. The operative mortality rates of reoperations for thrombosed mechanical valves are several times higher than those for tissue valves, and long-term results are also disappointing. Under-anticoagulation prevails in these regions that has clearly been linked to poor international normalised ratio (INR) monitoring. In industrialised countries, safe anticoagulation is defined as >60%-70% of the time in the therapeutic range (TTR). In LMICs, the TTR has been found to be in the range of twenty to forty percent. In this study, we analysed >20,000 INR test results of 552 consecutive patients receiving a mechanical valve for RHD. Only 27% of these test results were in the therapeutic range, with the vast majority (61%) being sub-therapeutic. Interestingly, the post-operative frequency of INR tests of one every 3-4 weeks in year 1 had dropped to less than 1 per year by year 7. LMICs need to use clinical judgement and assess the probability of insufficient INR monitoring prior to uncritically applying Western guidelines predominantly based on chronological age. The process of identification of high-risk subgroups in terms of non-adherence to anticoagulation control should take into account both the adherence history of >50% of patients with RHD who were in chronic atrial fibrillation prior to surgery as well as geographic and socioeconomic circumstances.

7.
J Vasc Surg ; 58(4): 1053-61, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23541549

RESUMO

BACKGROUND: In humans, transanastomotic endothelial outgrowth onto the surface of prosthetic vascular grafts is limited to the immediate perianastomotic region, even after years of implantation. In contrast, continual transanastomotic outgrowth together with short graft lengths has led to early endothelial confluence in most animal models pre-empting endothelialization through transmural capillary sprouting. We describe an isolation loop-graft model that clearly separates these distinctly different events. METHODS: Baseline transanastomotic endothelialization was assessed by implanting low-porosity expanded polytetrafluoroethylene grafts (ePTFE; internal diameter 1.7 mm; internodal distance 15-25 µm; 14.2 ± 1.6 mm long) for 2, 4, and 6 weeks (n = 6/time point) in the abdominal aorta of Wistar rats. High-porosity polyurethane (internal diameter 1.7 mm-150 µm pore size) grafts were then interposed ("welded") into the midsection of the ePTFE grafts for 2, 4, 6, and 8 weeks (n = 6/time point). Looping the interposition grafts increased their length to 70.3 ± 8.3 mm. After implantation periods of 6, 8, 12, and 24 weeks (n = 8/time point) isolation loop grafts were analyzed by light, immune-fluorescence (CD31) and scanning electron microscopy, and endothelialization was expressed as maximal transanastomotic endothelial outgrowth (I(max)), mean transanastomotic outgrowth (I(mean)), and segmental graft coverage (GSE). RESULTS: Transanastomotic outgrowth slowed down between 2 and 6 weeks of implantation (proximal: [I(max) from 0.9 ± 0.5 to 0.3 ± 0.3 mm/wk; P < .04; I(mean) from 0.3 ± 0.1 to 0.2 ± 0.1 mm/wk; nonsignificant (NS)]; distal: [I(max) from 0.7 ± 0.3 to 0.3 ± 0.2 mm/wk; P < .02; I(mean) from 0.3 ± 0.2 to 0.2 ± 0.0 mm/wk; NS]) but remained constant thereafter (I(max) = 0.5 ± 0.2 mm/wk; I(mean) = 0.4 ± 0.2 mm/wk at 24 weeks NS). In straight composite grafts, the ePTFE separation zones were too short to isolate transmural ingrowth beyond week 4. In contrast, a broad endothelial-free separation zone was preserved in all looped composite grafts even after half a year of implantation (25.9 ± 5.9 vs 8.7 ± 4.9 mm proximally and 21.9 ± 13.4 vs 12.3 ± 6.2 mm distally at 6 and 24 weeks, respectively). Ninety-three percent of patent loop-grafts showed isolated transmural midgraft endothelium after 4 weeks and 97% after 6 weeks. Midgraft preconfluence was reached by 6 weeks (GSE = 55 ± 45%) and confluence between week 12 and 24 (GSE = 95.0 ± 10.0% and 84.0 ± 30.13%). The subintimal thickness stayed constant with a nonsignificant trend toward regression (91.8 ± 93.9 mm vs 71.4 ± 59.4 mm at 6 and 24 weeks, respectively; NS). CONCLUSIONS: Transmural endothelialization can be clearly distinguished from transanastomotic outgrowth in a high throughput rat model. A looped interposition graft model provides sufficient isolation length to separate the two events for up to half a year and does not result in an increase in intimal hyperplasia. CLINICAL RELEVANCE: Although the mode of graft deployment has changed over the years, the problem of an absent surface endothelium remains, whether small- to medium-diameter grafts are surgically implanted or placed endovascularly as "covered stents." In contrast to humans, most animal models experience progressive transanastomotic endothelial outgrowth. Together with graft lengths that were too short, the clinically irrelevant transanastomotic endothelialization inadvertently led to early endothelial confluence in the vast majority of experimental vascular graft studies pre-empting or concealing alternative modes of endothelialization. The isolation loop-graft model we propose allows the long-term differentiation of the different modes of endothelialization in a small animal screening model.


Assuntos
Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Proliferação de Células , Células Endoteliais/patologia , Animais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Aortografia , Hiperplasia , Masculino , Politetrafluoretileno , Porosidade , Desenho de Prótese , Ratos , Ratos Wistar , Fatores de Tempo
8.
Eur Heart J ; 38(46): 3402-3404, 2017 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-29232446
9.
Eur J Cardiothorac Surg ; 63(4)2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-36548449

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the impact of a polyphenols-based treatment on the extrinsic mechanisms responsible for early bioprosthetic heart valve (BHV) degeneration. Structural degeneration can be driven by both extrinsic and intrinsic mechanisms. While intrinsic mechanisms have been associated with inherent biocompatibility characteristics of the BHV, the extrinsic ones have been reported to involve external causes, such as chemical, mechanical and hydrodynamic, responsible to facilitate graft damage. METHODS: The chemical interaction and the stability degree between polyphenols and pericardial tissue were carefully evaluated. The detoxification of glutaraldehyde in commercial BHVs models and the protective effect from in vivo calcification were taken into relevant consideration. Finally, the hydrodynamic and biomechanical features of the polyphenols-treated pericardial tissue were deeply investigated by pulse duplicator and stress-strain analysis. RESULTS: The study demonstrated the durability of the polyphenols-based treatment on pericardial tissue and the stability of the bound polyphenols. The treatment improves glutaraldehyde stabilization's current degree, demonstrating a surprising in vivo anti-calcific effect. It is able to make the pericardial tissue more pliable while maintaining the correct hydrodynamic characteristics. CONCLUSIONS: The polyphenols treatment has proved to be a promising approach capable of acting simultaneously on several factors related to the premature degeneration of cardiac valve substitutes by extrinsic mechanisms.


Assuntos
Bioprótese , Calcinose , Próteses Valvulares Cardíacas , Humanos , Glutaral , Valvas Cardíacas
10.
Front Immunol ; 14: 1210098, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37426661

RESUMO

Introduction: Preformed antibodies against αGal in the human and the presence of αGal antigens on the tissue constituting the commercial bioprosthetic heart valves (BHVs, mainly bovine or porcine pericardium), lead to opsonization of the implanted BHV, leading to deterioration and calcification. Murine subcutaneous implantation of BHVs leaflets has been widely used for testing the efficacy of anti-calcification treatments. Unfortunately, commercial BHVs leaflets implanted into a murine model will not be able to elicit an αGal immune response because such antigen is expressed in the recipient and therefore immunologically tolerated. Methods: This study evaluates the calcium deposition on commercial BHV using a new humanized murine αGal knockout (KO) animal model. Furtherly, the anti-calcification efficacy of a polyphenol-based treatment was deeply investigated. By using CRISPR/Cas9 approach an αGal KO mouse was created and adopted for the evaluation of the calcific propensity of original and polyphenols treated BHV by subcutaneous implantation. The calcium quantification was carried out by plasma analysis; the immune response evaluation was performed by histology and immunological assays. Anti-αGal antibodies level in KO mice increases at least double after 2 months of implantation of original commercial BHV compared to WT mice, conversely, the polyphenols-based treatment seems to effectively mask the antigen to the KO mice's immune system. Results: Commercial leaflets explanted after 1 month from KO mice showed a four-time increased calcium deposition than what was observed on that explanted from WT. Polyphenol treatment prevents calcium deposition by over 99% in both KO and WT animals. The implantation of commercial BHV leaflets significantly stimulates the KO mouse immune system resulting in massive production of anti-Gal antibodies and the exacerbation of the αGal-related calcific effect if compared with the WT mouse. Discussion: The polyphenol-based treatment applied in this investigation showed an unexpected ability to inhibit the recognition of BHV xenoantigens by circulating antibodies almost completely preventing calcific depositions compared to the untreated counterpart.


Assuntos
Bioprótese , Calcinose , Animais , Suínos , Bovinos , Humanos , Camundongos , Camundongos Knockout , Formação de Anticorpos , Bioprótese/efeitos adversos , Cálcio , Antígenos , Valvas Cardíacas , Modelos Animais , Anticorpos
11.
Glob Heart ; 18(1): 49, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37720311

RESUMO

Socioeconomic factors such as poor health and poor nutrition in low- and middle-income countries (LMICs) may favour inflammatory reactions, thus contributing to the recurrence of rheumatic fever (RF) and thereby modifying trends in rheumatic heart disease (RHD). Apart from epidemiological studies, studies of HIV infections in RHD patients are limited. This systematic review synthesises data on the prevalence and impact of HIV infections or AIDS on RHD from PubMed, Scopus, Web of Science databases up to April 2021. The outcomes were managed using PRISMA guidelines. Of a total of 15 studies found, 10 were eligible for meta-analyses. Meta-analysis found that 17% (95 % CI 8-33, I2 = 91%) of adults in cardiovascular disease (CVD) cohorts in Southern Africa are HIV positive. The proportion of RHD diagnosed among people living with HIV was 4% (95% CI 2-8, I2 = 79%) for adults but lower [2% (95% CI 1-4, I2 = 87%)] among perinatally infected children. Despite limited reporting, HIV-infected patients with RHD are prone to other infections that may enhance cardiac complications due to poor immunological control. PROSPERO registration number: CRD42021237046.


Assuntos
Doenças Cardiovasculares , Infecções por HIV , Febre Reumática , Cardiopatia Reumática , Adulto , Criança , Humanos , Cardiopatia Reumática/complicações , Cardiopatia Reumática/epidemiologia , Prevalência , Infecções por HIV/complicações , Infecções por HIV/epidemiologia , Febre Reumática/epidemiologia
12.
J Vasc Surg ; 55(6): 1734-41, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22386141

RESUMO

BACKGROUND: Flow patterns and shear forces in native coronary arteries are more protective against neointimal hyperplasia than those in femoral arteries. Yet, the caliber mismatch with their target arteries makes coronary artery bypass grafts more likely to encounter intimal hyperplasia than their infrainguinal counterparts due to the resultant slow flow velocity and decreased wall stress. To allow a site-specific, flow-related comparison of remodeling behavior, saphenous vein bypass grafts were simultaneously implanted in femoral and coronary positions. METHODS: Saphenous vein grafts were concomitantly implanted as coronary and femoral bypass grafts using a senescent nonhuman primate model. Duplex ultrasound-based blood flow velocity profiles and vein graft and target artery dimensions were correlated with dimensional and histomorphologic graft remodeling in large, senescent Chacma baboons (n = 8; 28.1 ± 4.9 kg) during a 24-week period. RESULTS: At implantation, the cross-sectional quotient (Q(c)) between target arteries and vein grafts was 0.62 ± 0.10 for femoral grafts vs 0.17 ± 0.06 for coronary grafts, resulting in a dimensional graft-to-artery mismatch 3.6 times higher (P < .0001) in coronary grafts. Together with different velocity profiles, these site-specific dimensional discrepancies resulted in a 57.9% ± 19.4% lower maximum flow velocity (P = .0048), 48.1% ± 23.6% lower maximal cycling wall shear stress (P = .012), and 62.2% ± 21.2% lower mean velocity (P = .007) in coronary grafts. After 24 weeks, the luminal diameter of all coronary grafts had contracted by 63%, from an inner diameter of 4.49 ± 0.60 to 1.68 ± 0.63 mm (P < .0001; subintimal diameter: -41.5%; P = .002), whereas 57% of the femoral interposition grafts had dilated by 31%, from 4.21 ± 0.25 to 5.53 ± 1.30 mm (P = .020). Neointimal tissue was 2.3 times thicker in coronary than in femoral grafts (561 ± 73 vs 240 ± 149 µm; P = .001). Overall, the luminal area of coronary grafts was an average of 4.1 times smaller than that of femoral grafts. CONCLUSIONS: Although coronary and infrainguinal bypass surgery uses saphenous veins as conduits, they undergo significantly different remodeling processes in these two anatomic positions.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Vasos Coronários/cirurgia , Artéria Femoral/cirurgia , Neointima/etiologia , Veia Safena/transplante , Túnica Íntima/cirurgia , Animais , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Dilatação Patológica , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Artéria Femoral/fisiopatologia , Hiperplasia , Modelos Animais , Modelos Cardiovasculares , Neointima/diagnóstico por imagem , Neointima/patologia , Neointima/fisiopatologia , Papio ursinus , Fluxo Sanguíneo Regional , Veia Safena/diagnóstico por imagem , Veia Safena/patologia , Veia Safena/fisiopatologia , Fatores de Tempo , Túnica Íntima/patologia , Ultrassonografia Doppler Dupla
13.
J Heart Valve Dis ; 21(4): 424-32, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22953666

RESUMO

BACKGROUND AND AIM OF THE STUDY: In developing countries rheumatic heart disease is the predominant indication for cardiac surgery. As the disease tends to progress, reoperation rates for mitral valve repairs are high. Against this background, the predictors of failure were assessed and the overall performance of repairs compared with replacements in a 10-year cohort of rheumatic single mitral valve procedures. METHODS: Between 2000 and 2010, a total of 646 consecutive adult (aged >15 years) patients underwent primary, single mitral valve procedures. All 87 percutaneous balloon valvuloplasties (100%) were rheumatic, compared to 280 of the 345 primary mitral valve replacements (81%) and 69 of the 215 primary mitral valve repairs (32%). As the study aim was to compare the outcome of mitral valve repair versus replacement in rheumatic patients of a threshold country, all 69 repair patients were propensity-matched with 69 of the replacement patients. Based on propensity score analysis, Kaplan-Meier actuarial analysis with log-rank testing was used to evaluate survival and morbidity. RESULTS: The follow up was 100% complete (n = 138), and ranged from 0.6 to 132 months (mean 53.3 +/- 36.5 months). Actuarial freedom from valve-related mortality was 96 +/- 3% and 92 +/- 4% at five years, and 96 +/- 3% and 80 +/- 11% at 10 years for repairs and replacements, respectively (p = NS). Actuarial freedom from all valve-related events (deaths, reoperations and morbidity) was 80 +/- 6% and 86 +/- 5% at five years, and 70 +/- 8% and 69 +/- 11% at 10 years (p = NS). Actuarial freedom from all valve-related events was 57 +/- 11% and 96 +/- 3% at five years (p = 0.0008), and 42 +/- 12% and 96 +/- 3% at 10 years (p < 0.001) for those mitral valve repairs with and without commissural fusion, respectively (p = 0.0002 overall). CONCLUSION: The long-term results for mitral valve replacement in an indigent, rheumatic heart disease population of a developing country were better than generally perceived. Notwithstanding, mitral valve repair has a superior long-term outcome in those patients who do not show commissural fusion at operation.


Assuntos
Implante de Prótese de Valva Cardíaca/mortalidade , Anuloplastia da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/cirurgia , Cardiopatia Reumática/mortalidade , Cardiopatia Reumática/cirurgia , Adolescente , Adulto , Idoso , Fibrilação Atrial/mortalidade , Criança , Países em Desenvolvimento/estatística & dados numéricos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/métodos , Morbidade , Reoperação/mortalidade , África do Sul/epidemiologia , Cuidados de Saúde não Remunerados/estatística & dados numéricos , Adulto Jovem
14.
Fam Pract ; 29(5): 511-20, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22379186

RESUMO

BACKGROUND: There are only a few trials for the very elderly population (>79 years). No consensus, which blood pressure (BP) goals and substances should be applied, has been found yet. This survey was undertaken to investigate how octogenarians are treated and attain BP targets in the Swiss primary care. METHODS: Data from 4594 hypertensive patients were collected within 7 days. Eight hundred and seventy-seven patients met the requirement to be >79 years. We assessed substances/combinations and investigated pulse pressure and target blood pressure attainment (TBPA) using three different recommendations [Canadian Hypertension Education Program (CHEP), Swiss Society of Hypertension (SSH), European Society of Hypertension-European Society of Cardiology (ESH-ESC)]. Secondarily, we compared TBPA attained by angiotensin-converting enzyme inhibitor (ACEI)/diuretic (D), angiotensin receptor blocker (ARB)/D and calcium channel blocker (CCB)/D with any other dual therapy and investigated whether Ds/beta-blockers (BBs) or Ds/renin angiotensin-converting enzyme inhibitors (RAAS-Is) lead to higher TBPA. Finally, we assessed the impact of drug administration, practical work experience, location and specialization of GPs on TBPA. RESULTS: Octogenarians attained target blood pressure (TBP) between 44% (ESH-ESC) and 74% (SSH). Optimal/normal BP was reached in 22.8% of patients. Pulse pressure <65 mmHg was shown in 66.4% of patients. Monotherapy was most commonly applied followed by dual single-pill combination with ARB/D (46.5%) or ACEI/D (36.0%). No benefit in TBPA was found comparing a RAASI/D and CCB/D treatment with any other dual combination. There was also no difference between BB/D and RAAS-I/D combination therapy and between single-pill combination and dual free combinations. CONCLUSIONS: GPs adhere to the use of substances proven in outcome trials and attain high TBP. No difference in meeting BP goals could be found using different drug classes. There is an unmet need to harmonize recommendations and to add additional information for the treatment of octogenarians.


Assuntos
Objetivos , Hipertensão/tratamento farmacológico , Guias de Prática Clínica como Assunto , Idoso de 80 Anos ou mais , Determinação da Pressão Arterial , Feminino , Fidelidade a Diretrizes , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Atenção Primária à Saúde , Valores de Referência , Suíça , Resultado do Tratamento
15.
Eur Heart J ; 32(22): 2830-40, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21415068

RESUMO

AIMS: A living heart valve with regeneration capacity based on autologous cells and minimally invasive implantation technology would represent a substantial improvement upon contemporary heart valve prostheses. This study investigates the feasibility of injectable, marrow stromal cell-based, autologous, living tissue engineered heart valves (TEHV) generated and implanted in a one-step intervention in non-human primates. METHODS AND RESULTS: Trileaflet heart valves were fabricated from non-woven biodegradable synthetic composite scaffolds and integrated into self-expanding nitinol stents. During the same intervention autologous bone marrow-derived mononuclear cells were harvested, seeded onto the scaffold matrix, and implanted transapically as pulmonary valve replacements into non-human primates (n = 6). The transapical implantations were successful in all animals and the overall procedure time from cell harvest to TEHV implantation was 118 ± 17 min. In vivo functionality assessed by echocardiography revealed preserved valvular structures and adequate functionality up to 4 weeks post implantation. Substantial cellular remodelling and in-growth into the scaffold materials resulted in layered, endothelialized tissues as visualized by histology and immunohistochemistry. Biomechanical analysis showed non-linear stress-strain curves of the leaflets, indicating replacement of the initial biodegradable matrix by living tissue. CONCLUSION: Here, we provide a novel concept demonstrating that heart valve tissue engineering based on a minimally invasive technique for both cell harvest and valve delivery as a one-step intervention is feasible in non-human primates. This innovative approach may overcome the limitations of contemporary surgical and interventional bioprosthetic heart valve prostheses.


Assuntos
Próteses Valvulares Cardíacas , Transplante de Células-Tronco Mesenquimais , Monócitos/transplante , Valva Pulmonar/fisiologia , Transplante de Células-Tronco/métodos , Animais , Bioprótese , Estudos de Viabilidade , Citometria de Fluxo , Sobrevivência de Enxerto/fisiologia , Injeções , Microscopia Eletrônica de Varredura , Papio ursinus , Stents , Engenharia Tecidual , Alicerces Teciduais , Transplante Autólogo
16.
Cardiol Cardiovasc Med ; 6(5): 487-492, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36303878

RESUMO

Background: The incidence of infective endocarditis in patients with bioprosthetic heart valves is over 100 times that of the general population with S. aureus recognized as the causative organism in approximately 1/3 of cases. In this study, (1) the microbicidal and virucidal effect of a polyphenolic solution was carefully evaluated. The same solution was then adopted for the treatment of a commercial bioprosthetic heart valve model for (2) the assessment of inhibition of S. aureus adhesiveness. Methods: (1) the viability of 9 microorganisms strains (colony-forming units) and the infectivity degree of 3 viral strains (cellular infection capacity) were evaluated after suspension in the polyphenolic solution. (2) Leaflets from a treated and untreated commercial surgical valve model were incubated with a known concentration of S. aureus. After incubation, the leaflets were homogenized and placed in specific culture media to quantify the bacterial load. Results: (1) The polyphenolic solution proved to be effective in eliminating microorganisms strains guaranteeing the killing of at least 99.9%. The effectiveness is particularly relevant against M. chelonae (99.999%). (2) The polyphenol-based treatment resulted in the inhibition of the S. aureus adhesiveness by 96% concerning untreated samples. Conclusions: The data suggest an interesting protective effect against infections and bacterial adhesiveness by a polyphenolic-based solution. Further studies will plan to extend the panel of microorganisms for the evaluation of the anti-adhesive effect; however, the use of optimized polyphenolic blends could lead to the development of new treatments capable to make transcatheter-valve substitutes more resistant to infection.

17.
Front Cardiovasc Med ; 9: 791949, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35310972

RESUMO

Leaflet durability and costs restrict contemporary trans-catheter aortic valve replacement (TAVR) largely to elderly patients in affluent countries. TAVR that are easily deployable, avoid secondary procedures and are also suitable for younger patients and non-calcific aortic regurgitation (AR) would significantly expand their global reach. Recognizing the reduced need for post-implantation pacemakers in balloon-expandable (BE) TAVR and the recent advances with potentially superior leaflet materials, a trans-catheter BE-system was developed that allows tactile, non-occlusive deployment without rapid pacing, direct attachment of both bioprosthetic and polymer leaflets onto a shape-stabilized scallop and anchorage achieved by plastic deformation even in the absence of calcification. Three sizes were developed from nickel-cobalt-chromium MP35N alloy tubes: Small/23 mm, Medium/26 mm and Large/29 mm. Crimp-diameters of valves with both bioprosthetic (sandwich-crosslinked decellularized pericardium) and polymer leaflets (triblock polyurethane combining siloxane and carbonate segments) match those of modern clinically used BE TAVR. Balloon expansion favors the wing-structures of the stent thereby creating supra-annular anchors whose diameter exceeds the outer diameter at the waist level by a quarter. In the pulse duplicator, polymer and bioprosthetic TAVR showed equivalent fluid dynamics with excellent EOA, pressure gradients and regurgitation volumes. Post-deployment fatigue resistance surpassed ISO requirements. The radial force of the helical deployment balloon at different filling pressures resulted in a fully developed anchorage profile of the valves from two thirds of their maximum deployment diameter onwards. By combining a unique balloon-expandable TAVR system that also caters for non-calcific AR with polymer leaflets, a powerful, potentially disruptive technology for heart valve disease has been incorporated into a TAVR that addresses global needs. While fulfilling key prerequisites for expanding the scope of TAVR to the vast number of patients of low- to middle income countries living with rheumatic heart disease the system may eventually also bring hope to patients of high-income countries presently excluded from TAVR for being too young.

18.
J Vasc Surg ; 54(5): 1439-50, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21802240

RESUMO

OBJECTIVE: Constriction of vein grafts with braided external nitinol meshes had previously led to the successful elimination of neointimal tissue formation. We investigated whether pulse compliance, smaller kink-free bending radius, and milder medial atrophy can be achieved by knitting the meshes rather than braiding, without losing the suppressive effect on intimal hyperplasia. METHODS: Pulse compliance, bending stiffness, and bending radius, as well as longitudinal-radial deformation-coupling and radial compression, were compared in braided and knitted nitinol meshes. Identical to previous studies with braided mesh grafts, a senescent nonhuman primate model (Chacma baboons; bilateral femoral interposition grafts/6 months) mimicking the clinical size mismatch between vein grafts and runoff arteries was used to examine the effect of knitted external meshes on vein grafts: nitinol mesh-constricted (group 1); nitinol mesh-constricted and fibrin sealant (FS) spray-coated for mesh attachment (group 2); untreated control veins (group 3), and FS spray-coated control veins (group 4). RESULTS: Compared with braided meshes, knitted meshes had 3.8-times higher pulse compliance (3.43 ± 0.53 vs 0.94 ± 0.12%/100 mm Hg; P = .00002); 30-times lower bending stiffness (0.015 ± 0.002 vs 0.462 ± 0.077 Nmm(2); P = .0006); 9.2-times narrower kink-free bending radius (15.3 ± 0.4 vs 140.8 ± 22.4 mm; P = .0006), and 4.3-times lower radial narrowing caused by axial distension (18.0% ± 1.0% vs 77.0% ± 3.7%; P = .00001). Compared with mesh-supported grafts, neointimal tissue was 8.5-times thicker in group I (195 ± 45 µm) vs group III (23.0 ± 21.0 µm; P < .001) corresponding with a 14.3-times larger neointimal area in group I (4330 ± 957 × 103 µm(2)) vs group III (303 ± 221× 103 µm(2); P < .00004). FS had no significant influence. Medial muscle mass remained at 43.4% in knitted meshes vs the 28.1% previously observed in braided meshes. CONCLUSION: Combining the suppression of intimal hyperplasia with a more physiologic remodeling process of the media, manifold higher kink-resistance, and lower fraying than in braided meshes makes knitted nitinol an attractive concept in external vein graft protection.


Assuntos
Ligas , Artéria Femoral/cirurgia , Veia Femoral/transplante , Telas Cirúrgicas , Enxerto Vascular/instrumentação , Animais , Fenômenos Biomecânicos , Complacência (Medida de Distensibilidade) , Desenho de Equipamento , Artéria Femoral/fisiopatologia , Artéria Femoral/ultraestrutura , Veia Femoral/fisiopatologia , Veia Femoral/ultraestrutura , Adesivo Tecidual de Fibrina , Hiperplasia , Teste de Materiais , Microscopia Eletrônica de Varredura , Modelos Animais , Papio ursinus , Fluxo Pulsátil , Fatores de Tempo , Enxerto Vascular/efeitos adversos
19.
Front Cardiovasc Med ; 8: 760635, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35059444

RESUMO

Despite early realization of the need to control inherent immunogenicity of bioprosthetic replacement heart valves and thereby mitigate the ensuing host response and its associated pathology, including dystrophic calcification, the problem remains unresolved to this day. Concerns over mechanical stiffness associated with prerequisite high cross-link density to effect abrogation of this response, together with the insinuated role of leaching glutaraldehyde monomer in subsequent dystrophic mineralization, have understandably introduced compromises. These have become so entrenched as a benchmark standard that residual immunogenicity of the extracellular matrix has seemingly been relegated to a very subordinate role. Instead, focus has shifted toward the removal of cellular compartment antigens renowned for their implication in the failure of vascularized organ xenotransplants. While decellularization certainly offers advantages, this review aims to refocus attention on the unresolved matter of the host response to the extracellular matrix. Furthermore, by implicating remnant immune and inflammatory processes to bioprosthetic valve pathology, including pannus overgrowth and mineralization, the validity of a preeminent focus on decellularization, in the context of inefficient antigen and possible residual microbial remnant removal, is questioned.

20.
Front Cardiovasc Med ; 8: 728577, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34589529

RESUMO

The use of bioprostheses for heart valve therapy has gradually evolved over several decades and both surgical and transcatheter devices are now highly successful. The rapid expansion of the transcatheter concept has clearly placed a significant onus on the need for improved production methods, particularly the pre-treatment of bovine pericardium. Two of the difficulties associated with the biocompatibility of bioprosthetic valves are the possibilities of immune responses and calcification, which have led to either catastrophic failure or slow dystrophic changes. These have been addressed by evolutionary trends in cross-linking and decellularization techniques and, over the last two decades, the improvements have resulted in somewhat greater durability. However, as the need to consider the use of bioprosthetic valves in younger patients has become an important clinical and sociological issue, the requirement for even greater longevity and safety is now paramount. This is especially true with respect to potential therapies for young people who are afflicted by rheumatic heart disease, mostly in low- to middle-income countries, for whom no clinically acceptable and cost-effective treatments currently exist. To extend longevity to this new level, it has been necessary to evaluate the mechanisms of pericardium biocompatibility, with special emphasis on the interplay between cross-linking, decellularization and anti-immunogenicity processes. These mechanisms are reviewed in this paper. On the basis of a better understanding of these mechanisms, a few alternative treatment protocols have been developed in the last few years. The most promising protocol here is based on a carefully designed combination of phases of tissue-protective decellularization with a finely-titrated cross-linking sequence. Such refined protocols offer considerable potential in the progress toward superior longevity of pericardial heart valves and introduce a scientific dimension beyond the largely disappointing 'anti-calcification' treatments of past decades.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA