Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 28(Pt 1): 131-145, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399562

RESUMO

In this paper the back-side-illuminated Percival 2-Megapixel (P2M) detector is presented, along with its characterization by means of optical and X-ray photons. For the first time, the response of the system to soft X-rays (250 eV to 1 keV) is presented. The main performance parameters of the first detector are measured, assessing the capabilities in terms of noise, dynamic range and single-photon discrimination capability. Present limitations and coming improvements are discussed.

2.
J Synchrotron Radiat ; 26(Pt 1): 74-82, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30655470

RESUMO

The Adaptive Gain Integrating Pixel Detector (AGIPD) is an X-ray imager, custom designed for the European X-ray Free-Electron Laser (XFEL). It is a fast, low-noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1 keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 104 photons of 12 keV. In burst mode the system is able to store 352 images while running at up to 6.5 MHz, which is compatible with the 4.5 MHz frame rate at the European XFEL. The AGIPD system was installed and commissioned in August 2017, and successfully used for the first experiments at the Single Particles, Clusters and Biomolecules (SPB) experimental station at the European XFEL since September 2017. This paper describes the principal components and performance parameters of the system.

3.
J Synchrotron Radiat ; 23(1): 111-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698052

RESUMO

With the increased brilliance of state-of-the-art synchrotron radiation sources and the advent of free-electron lasers (FELs) enabling revolutionary science with EUV to X-ray photons comes an urgent need for suitable photon imaging detectors. Requirements include high frame rates, very large dynamic range, single-photon sensitivity with low probability of false positives and (multi)-megapixels. At DESY, one ongoing development project - in collaboration with RAL/STFC, Elettra Sincrotrone Trieste, Diamond, and Pohang Accelerator Laboratory - is the CMOS-based soft X-ray imager PERCIVAL. PERCIVAL is a monolithic active-pixel sensor back-thinned to access its primary energy range of 250 eV to 1 keV with target efficiencies above 90%. According to preliminary specifications, the roughly 10 cm × 10 cm, 3.5k × 3.7k monolithic sensor will operate at frame rates up to 120 Hz (commensurate with most FELs) and use multiple gains within 27 µm pixels to measure 1 to ∼100000 (500 eV) simultaneously arriving photons. DESY is also leading the development of the AGIPD, a high-speed detector based on hybrid pixel technology intended for use at the European XFEL. This system is being developed in collaboration with PSI, University of Hamburg, and University of Bonn. The AGIPD allows single-pulse imaging at 4.5 MHz frame rate into a 352-frame buffer, with a dynamic range allowing single-photon detection and detection of more than 10000 photons at 12.4 keV in the same image. Modules of 65k pixels each are configured to make up (multi)megapixel cameras. This review describes the AGIPD and the PERCIVAL concepts and systems, including some recent results and a summary of their current status. It also gives a short overview over other FEL-relevant developments where the Photon Science Detector Group at DESY is involved.

4.
Bioanalysis ; 2(8): 1469-75, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21083347

RESUMO

BACKGROUND: Dried blood spot (DBS) sampling could potentially become the preferred blood collection technique in toxicological and clinical studies. Autoradiography was performed to study compound distribution within a dbs under different conditions using five papers, 31ETF, Grade 226, 903(®), FTA(®) and FTA(®) Elute. RESULTS: The results showed an uneven distribution in all papers with common distribution patterns regardless of compounds: decreased concentrations along the edge, the volcano effect in the middle and the speckle pattern in the center. Treated papers were more readily influenced by environmental factors. CONCLUSION: Autoradiography enables visualization of a compound's distribution and can guide bioanalytical assay development by allowing convenient evaluation of factors, such as choice of paper, spotting volume, punch size, punch location, temperature and humidity.


Assuntos
Análise Química do Sangue/métodos , Coleta de Amostras Sanguíneas/instrumentação , Papel , Radioatividade , Adulto , Coagulação Sanguínea , Fenômenos Químicos , Dessecação , Hematócrito , Humanos , Umidade , Laboratórios , Masculino , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA