Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38713843

RESUMO

BACKGROUND: The BIONYX randomized trial is the first study to evaluate the Resolute Onyx durable polymer-coated zotarolimus-eluting stent (ZES) in all-comers. Furthermore, it is the first trial to assess safety and efficacy of this stent versus the Orsiro biodegradable-polymer sirolimus-eluting stent (SES) in all-comers, paying particular attention to patients with diabetes. It has previously shown promising results until 3 years of follow-up. AIMS: We aimed to assess long-term clinical outcome after percutaneous coronary intervention (PCI) with Onyx ZES versus Orsiro SES at 5-year follow-up. METHODS: The main composite endpoint was target vessel failure (TVF): cardiac death, target vessel myocardial infarction, or target vessel revascularization. Time to primary and secondary endpoints was assessed using Kaplan-Meier methods, applying the log-rank test for between-group comparison. RESULTS: Follow-up was available in 2414/2488 (97.0%) patients. After 5 years, TVF showed no significant difference between Onyx ZES and Orsiro SES (12.7% vs. 13.7%, hazard ratio [HR] 0.94, 95% confidence interval [CI] [0.75-1.17], plog-rank = 0.55). Landmark analysis between 3- and 5-year follow-up found a lower target lesion revascularization rate for Onyx ZES (1.1% vs. 2.4%, HR 0.47, 95% CI [0.24-0.93], plog-rank = 0.026). A prespecified subgroup analysis showed no significant between-stent difference in clinical outcome among patients with diabetes. After treatment with Onyx ZES, patients aged ≥75 years had significantly lower rates of TVF (13.8% vs. 21.9%, HR 0.60, 95% CI [0.39-0.93], plog-rank = 0.023). CONCLUSIONS: The final 5-year analysis of the randomized BIONYX trial showed favorable and similar long-term outcomes of safety and efficacy for Onyx ZES and Orsiro SES in both all-comers and patients with diabetes.

2.
Neth Heart J ; 32(6): 254-261, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38776038

RESUMO

BACKGROUND: Several ethnic minorities have an increased risk of cardiovascular events, but previous European trials that investigated clinical outcome after coronary stenting did not assess the patients' ethnic background. AIMS: To compare ethnic minority and Western European trial participants in terms of both cardiovascular risk profile and 1­year clinical outcome after percutaneous coronary intervention. METHODS: In the BIO-RESORT and BIONYX randomised trials, which assessed new-generation drug-eluting stents, information on patients' self-reported ethnic background was prospectively collected. Pooled patient-level data of 5803 patients, enrolled in the Netherlands and Belgium, were analysed in this prespecified analysis. The main endpoint was target vessel failure after 1 year. RESULTS: Patients were classified as belonging to an ethnic minority (n = 293, 5%) or of Western European origin (n = 5510, 95%). Follow-up data were available in 5772 of 5803 (99.5%) patients. Ethnic minority patients were younger, less often female, more often current smokers, more often medically treated for diabetes, and more often had a positive family history of coronary artery disease. The main endpoint target vessel failure did not differ between ethnic minority and Western European patients (3.5% vs 4.9%, hazard ratio 0.71, 95% confidence interval 0.38-1.33; p = 0.28). There was also no difference in mortality, myocardial infarction, and repeat revascularisation rates. CONCLUSIONS: Despite the unfavourable cardiovascular risk profile of ethnic minority patients, short-term clinical outcome after treatment with contemporary drug-eluting stents was highly similar to that in Western European patients. Further efforts should be made to ensure the enrolment of more ethnic minority patients in future coronary stent trials.

3.
Catheter Cardiovasc Interv ; 102(2): 221-232, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37232278

RESUMO

BACKGROUND: Data about the long-term performance of new-generation ultrathin-strut drug-eluting stents (DES) in challenging coronary lesions, such as left main (LM), bifurcation, and chronic total occlusion (CTO) lesions are scant. METHODS: The international multicenter retrospective observational ULTRA study included consecutive patients treated from September 2016 to August 2021 with ultrathin-strut (<70 µm) DES in challenging de novo lesions. Primary endpoint was target lesion failure (TLF): composite of cardiac death, target-lesion revascularization (TLR), target-vessel myocardial infarction (TVMI), or definite stent thrombosis (ST). Secondary endpoints included all-cause death, acute myocardial infarction (AMI), target vessel revascularization, and TLF components. TLF predictors were assessed with Cox multivariable analysis. RESULTS: Of 1801 patients (age: 66.6 ± 11.2 years; male: 1410 [78.3%]), 170 (9.4%) experienced TLF during follow-up of 3.1 ± 1.4 years. In patients with LM, CTO, and bifurcation lesions, TLF rates were 13.5%, 9.9%, and 8.9%, respectively. Overall, 160 (8.9%) patients died (74 [4.1%] from cardiac causes). AMI and TVMI rates were 6.0% and 3.2%, respectively. ST occurred in 11 (1.1%) patients while 77 (4.3%) underwent TLR. Multivariable analysis identified the following predictors of TLF: age, STEMI with cardiogenic shock, impaired left ventricular ejection fraction, diabetes, and renal dysfunction. Among the procedural variables, total stent length increased TLF risk (HR: 1.01, 95% CI: 1-1.02 per mm increase), while intracoronary imaging reduced the risk substantially (HR: 0.35, 95% CI: 0.12-0.82). CONCLUSIONS: Ultrathin-strut DES showed high efficacy and satisfactory safety, even in patients with challenging coronary lesions. Yet, despite using contemporary gold-standard DES, the association persisted between established patient- and procedure-related features of risk and impaired 3-year clinical outcome.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Sirolimo , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Função Ventricular Esquerda , Infarto do Miocárdio/etiologia , Desenho de Prótese , Stents/efeitos adversos , Sistema de Registros , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações
4.
Cardiovasc Diabetol ; 20(1): 217, 2021 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-34717627

RESUMO

BACKGROUND: Diabetes is associated with adverse outcomes after percutaneous coronary intervention with drug-eluting stents (DES), but for prediabetes this association has not been definitely established. Furthermore, in patients with prediabetes treated with contemporary stents, bleeding data are lacking. We assessed 3-year ischemic and bleeding outcomes following treatment with new-generation DES in patients with prediabetes and diabetes as compared to normoglycemia. METHODS: For this post-hoc analysis, we pooled patient-level data of the BIO-RESORT and BIONYX stent trials which both stratified for diabetes at randomization. Both trials were multicenter studies performed in tertiary cardiac centers. Study participants were patients of whom glycemic state was known based on hemoglobin A1c, fasting plasma glucose, or medically treated diabetes. Three-year follow-up was available in 4212/4330 (97.3 %) patients. The main endpoint was target vessel failure, a composite of cardiac death, target vessel myocardial infarction, or target vessel revascularization. RESULTS: Baseline cardiovascular risk profiles were progressively abnormal in patients with normoglycemia, prediabetes, and diabetes. The main endpoint occurred in 54/489 patients with prediabetes (11.2 %) and 197/1488 with diabetes (13.7 %), as compared to 142/2,353 with normoglycemia (6.1 %) (HR: 1.89, 95 %-CI 1.38-2.58, p < 0.001, and HR: 2.30, 95 %-CI 1.85-2.86, p < 0.001, respectively). In patients with prediabetes, cardiac death and target vessel revascularization rates were significantly higher (HR: 2.81, 95 %-CI 1.49-5.30, p = 0.001, and HR: 1.92, 95 %-CI 1.29-2.87, p = 0.001), and in patients with diabetes all individual components of the main endpoint were significantly higher than in patients with normoglycemia (all p ≤ 0.001). Results were consistent after adjustment for confounders. Major bleeding rates were significantly higher in patients with prediabetes and diabetes, as compared to normoglycemia (3.9 % and 4.1 % vs. 2.3 %; HR:1.73, 95 %-CI 1.03-2.92, p = 0.040, and HR:1.78, 95 %-CI 1.23-2.57, p = 0.002). However, after adjustment for confounders, differences were no longer significant. CONCLUSIONS: Not only patients with diabetes but also patients with prediabetes represent a high-risk population. After treatment with new-generation DES, both patient groups had higher risks of ischemic and bleeding events. Differences in major bleeding were mainly attributable to dissimilarities in baseline characteristics. Routine assessment of glycemic state may help to identify patients with prediabetes for intensified management of cardiovascular risk factors. TRIAL REGISTRATION: BIO-RESORT ClinicalTrials.gov: NCT01674803, registered 29-08-2012; BIONYX ClinicalTrials.gov: NCT02508714, registered 27-7-2015.


Assuntos
Glicemia/metabolismo , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/sangue , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Estado Pré-Diabético/sangue , Idoso , Glicemia/efeitos dos fármacos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/mortalidade , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/mortalidade , Feminino , Hemoglobinas Glicadas/metabolismo , Hemorragia/mortalidade , Humanos , Hipoglicemiantes/uso terapêutico , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estado Pré-Diabético/tratamento farmacológico , Estado Pré-Diabético/mortalidade , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 98(2): E188-E196, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33694294

RESUMO

OBJECTIVES: To compare 2-year outcome following treatment with drug-eluting stents (DES) for acute myocardial infarction (MI) versus non-MI clinical syndromes. In acute MI patients, a stent-level comparison was performed, comparing Resolute Onyx versus Orsiro stents. BACKGROUND: In patients presenting with acute MI, higher adverse event rates have been reported. So far, no clinical results >1 year have been published of acute MI patients treated with Resolute Onyx. METHODS: This post-hoc analysis of the randomized BIONYX trial(NCT02508714) assessed the main outcome target vessel failure (TVF: cardiac death, target vessel MI, or target vessel revascularization) with Kaplan-Meier methods. RESULTS: Of all 2,488 trial participants, acute MI patients (n = 1,275[51.2%]) were significantly younger and had less comorbidities than non-MI patients (n = 1,213[48.8%]). TVF rates were lower in acute MI patients (77/1,275[6.1%] vs. 103/1,213[8.6%], HR:0.70, 95%-CI 0.52-0.94; plog-rank  = 0.02), mainly driven by target vessel revascularization (4.1 vs. 6.1%, plog-rank  = 0.03). Multivariate analysis showed no independent association of clinical syndrome with TVF (adjusted-HR: 0.81, 95%-CI 0.60-1.10; p = .17). In MI patients treated with Resolute Onyx (n = 626) versus Orsiro (n = 649), there was no difference in TVF (6.2 vs. 6.1%; plog-rank  = 0.97) and its components. There was only 1(0.2%) definite-or-probable stent thrombosis in RO-ZES and 8(1.2%) in O-SES (p = .053). CONCLUSIONS: Two years after treatment with thin-strut DES in this randomized trial, patients treated for acute MI had lower adverse event rates than non-MI patients. Yet, these findings were mainly attributable to between-group differences in patient and lesion characteristics. In patients who underwent PCI for acute MI, both Resolute Onyx and Orsiro showed favorable and similar 2-year outcomes.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Everolimo , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sirolimo , Stents , Resultado do Tratamento
6.
Circ J ; 85(11): 1983-1990, 2021 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-34261828

RESUMO

BACKGROUND: At 1 year, the international randomized BIONYX trial (ClinicalTrials.gov:NCT02508714) established non-inferiority regarding safety and efficacy of the novel Resolute Onyx zotarolimus-eluting stent (RO-ZES) vs. the Orsiro sirolimus-eluting stent (O-SES). Although the RO-ZES is used in daily practice, no clinical results have been published beyond 2 years.Methods and Results:We assessed 3-year clinical outcomes of 2,488 all-comers after percutaneous coronary intervention (PCI) with RO-ZES vs. O-SES. The main endpoint was target vessel failure (TVF), a composite of cardiac death, target vessel myocardial infarction (MI), or target vessel revascularization. Time-to-endpoints was assessed by Kaplan-Meier methods and between-group comparisons by log-rank tests. Follow-up was available in 2,433/2,488 (97.8%) patients. There was no significant between-stent difference in TVF (RO-ZES 112/1,243 [9.2%] vs. O-SES 109/1,245 [8.9%], hazard ratio [HR]: 1.03, 95% confidence interval [CI] 0.79-1.34; Plog-rank=0.85) and its individual components. The all-cause mortality was significantly lower after PCI with RO-ZES (3.7% vs.5.4%, HR: 0.67, 95% CI 0.46-0.97; Plog-rank=0.034), but cardiac mortality did not differ significantly (1.1% vs.1.9%, HR: 0.56, 95% CI 0.28-1.11; Plog-rank=0.09). Definite-or-probable stent thrombosis rates were low for both groups (0.6% vs.1.2%, HR: 0.46, 95% CI 0.19-1.14; Plog-rank=0.09). CONCLUSIONS: This first 3-year randomized assessment of the RO-ZES showed a favorable rate of TVF that matched the outcomes of patients treated with O-SES. We observed a lower rate of all-cause death in the RO-ZES group, but long-term clinical follow-up is of interest.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Stents , Resultado do Tratamento
7.
Am Heart J ; 228: 109-115, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32882569

RESUMO

BACKGROUND: Patients aged ≥80 years are often treated with new-generation drug-eluting stents (DES), but data from randomized studies are scarce owing to underrepresentation in most trials. We assessed 1-year clinical outcome of octogenarians treated with new-generation DES versus younger patients. METHODS: We pooled patient-level data of 9,204 participants in the TWENTE, DUTCH PEERS, BIO-RESORT, and BIONYX (TWENTE I-IV) randomized trials. The main clinical end point was target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction (MI), or clinically indicated target vessel revascularization. RESULTS: The 671 octogenarian trial participants had significantly more comorbidities. TVF was higher in octogenarians than in 8,533 patients <80 years (7.3% vs 5.3%, hazard ratio [HR]: 1.36, 95% CI: 1.0-1.83, P = .04). The cardiac death rate was higher in octogenarians (3.9% vs 0.8%, P < .001). There was no significant between-group difference in target vessel MI (2.3% vs 2.3%, P = .88) and repeat target vessel revascularization (1.9% vs 2.8%, P = .16). In multivariate analyses, age ≥ 80 years showed no independent association with TVF (adjusted HR: 1.04, 95% CI: 0.76-1.42), whereas the risk of cardiac death remained higher in octogenarians (adjusted HR: 3.38, 95% CI: 2.07-5.52, P < .001). In 6,002 trial participants, in whom data on major bleeding were recorded, octogenarians (n = 459) showed a higher major bleeding risk (5.9% vs 1.9%; HR: 3.08, 95% CI: 2.01-4.74, P < .001). CONCLUSIONS: Octogenarian participants in 4 large-scale randomized DES trials had more comorbidities and a higher incidence of the main end point TVF. Cardiac mortality was higher in octogenarians, whereas there was no increase in MI or target vessel revascularization rates. Treatment of octogenarian patients with new-generation DES appears to be safe and effective.


Assuntos
Stents Farmacológicos/classificação , Everolimo/farmacologia , Infarto do Miocárdio , Complicações Pós-Operatórias , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Reoperação/métodos , Reoperação/estatística & dados numéricos , Risco Ajustado/métodos , Fatores de Risco , Resultado do Tratamento
8.
Curr Opin Cardiol ; 35(6): 705-711, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32852343

RESUMO

PURPOSE OF REVIEW: The current article will review recently published clinical studies that evaluate very thin or ultrathin-strut drug-eluting stents (DES), focusing on major randomized clinical trials in broad patient populations. RECENT FINDINGS: Multiple randomized trials recently assessed the clinical performance of novel very thin to ultrathin-strut DES. Most randomized trials established noninferiority of the novel device. To date, only one major randomized clinical trial (i.e., BIOFLOW V) showed superiority of an ultrathin-strut biodegradable polymer-coated sirolimus-eluting stent over a very thin-strut durable polymer-coated everolimus-eluting stent in a relatively broad patient population. There are signals that the same ultrathin-strut biodegradable polymer-coated sirolimus-eluting stent may improve clinical outcome in specific patient populations. For example, in the randomized BIOSTEMI trial, 1-year superiority of the ultrathin-strut DES was found in patients presenting with an acute ST-segment elevation myocardial infarction. Yet, substudies of large randomized trials that assessed patients with small-vessel treatment showed equivocal results. SUMMARY: Although two randomized trials showed advantages for ultrathin-strut DES, other clinical trials provided no significant evidence that ultrathin-strut DES improve clinical outcome. The question whether ultrathin-strut DES may reduce the repeat revascularization risk following implantation in small vessels is a matter of further debate and future research.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Humanos , Polímeros , Desenho de Prótese , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 96(5): E508-E515, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32237060

RESUMO

OBJECTIVE: The objective was to assess the 2-year clinical performance of three drug-eluting stents in all-comer patients with severely calcified coronary lesions. BACKGROUND: Severe lesion calcification increases cardiovascular event risk after coronary stenting, but there is a lack of data on the clinical outcome of all-comers with severely calcified lesions who were treated with more recently introduced drug-eluting stents. METHODS: The BIO-RESORT trial (clinicaltrials.gov: NCT01674803) randomly assigned 3,514 all-comer patients to biodegradable polymer Synergy everolimus-eluting stents (EES) or Orsiro sirolimus-eluting stents (SES), versus durable polymer Resolute Integrity zotarolimus-eluting stents (ZES). In a post hoc analysis, we assessed 783 patients (22.3%) with at least one severely calcified target lesion. RESULTS: At 2-year follow-up (available in 99% of patients), the main composite endpoint target vessel failure occurred in 19/252 (7.6%) of the EES and in 33/265 (12.6%) of the ZES-treated patients (p = .07). Target vessel failure occurred in 24/266 (9.1%) of the SES-treated patients (vs. ZES: p = .21). There was a difference in target vessel revascularization, which was required in EES in 6/252 (2.4%) patients and in ZES in 20/265 (7.7%) patients (p = .01); the target vessel revascularization rate in SES was 9/266 (3.4%, vs. ZES: p = .04). Multivariate analysis showed that implantation of EES, but not SES, was independently associated with lower target vessel revascularization rates than in ZES. CONCLUSIONS: In BIO-RESORT participants with severely calcified target lesions, treatment with EES was associated with a lower 2-year target vessel revascularization rate than treatment with ZES.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Calcificação Vascular/terapia , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem
10.
Catheter Cardiovasc Interv ; 96(2): E110-E118, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31625262

RESUMO

BACKGROUND: Patients with coronary disease may have unknown diabetes or prediabetes. We evaluated 3-year outcomes after percutaneous coronary intervention (PCI) with contemporary drug-eluting stents (DES) in patients with silent diabetes, prediabetes, and normoglycemia. METHODS: All BIO-RESORT trial (NCT01674803) participants without known diabetes, enrolled at our center, were invited for oral glucose tolerance testing (OGTT) and measurements of fasting plasma glucose and glycated hemoglobin (HbA1c). RESULTS: OGTT detected silent diabetes in 68 (6.9%), prediabetes in 132 (13.4%), and normoglycemia in 788 (79.8%) of all 988 study participants. Follow-up was available in 986 (99.8%) patients. The main endpoint target vessel failure (TVF: cardiac death, target vessel-related myocardial infarction [MI], or target vessel revascularization) differed between groups (14.8, 9.9, and 5.6%; p = .002), driven by MI during the first 48 hr and by cardiac death (p < .001; p = .026). Between 48 hr and 3-years, there was no significant between-group difference in TVF, target vessel MI, and target vessel revascularization. Multivariable analysis demonstrated that silent diabetes was independently associated with TVF (adjusted HR: 2.52, 95%-CI: 1.26-5.03). An alternative diagnostic approach-HbA1c and fasting plasma glucose-detected silent diabetes and prediabetes in 33 (3.3%) and 217 (22.0%) patients, and normoglycemia in 738 (74.7%); TVF rates were 12.1, 7.9, and 6.0% (p = .23). CONCLUSION: In patients without known diabetes, abnormal glucose metabolism by OGTT was independently associated with higher 3-year TVF rates after PCI with contemporary DES. This difference was driven by periprocedural MI and cardiac death. After the first 48 hr, the rates of TVF, target vessel MI, and target vessel revascularization were low and did not differ significantly between metabolic groups.


Assuntos
Glicemia/metabolismo , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/diagnóstico , Stents Farmacológicos , Teste de Tolerância a Glucose , Intervenção Coronária Percutânea/instrumentação , Estado Pré-Diabético/diagnóstico , Idoso , Doenças Assintomáticas , Biomarcadores/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/sangue , Diabetes Mellitus/mortalidade , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estado Pré-Diabético/sangue , Estado Pré-Diabético/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Lancet ; 392(10154): 1235-1245, 2018 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-30253879

RESUMO

BACKGROUND: During the past decade, many patients had zotarolimus-eluting stents implanted, which had circular shape cobalt-chromium struts with limited radiographic visibility. The Resolute Onyx stent was developed to improve visibility while reducing strut thickness, which was achieved by using a novel composite wire with a dense platinum-iridium core and an outer cobalt-chromium layer. We did the first randomised clinical trial to assess the safety and efficacy of this often-used stent compared with the Orsiro stent, which consists of ultrathin cobalt-chromium struts. METHODS: We did an investigator-initiated, assessor-blinded and patient-blinded, randomised non-inferiority trial in an allcomers population at seven independently monitored centres in Belgium, Israel, and the Netherlands. Eligible participants were aged 18 years or older and required percutaneous coronary intervention with drug-eluting stents. After guide wire passage with or without predilation, members of the catheterisation laboratory team used web-based computer-generated allocation sequences to randomly assign patients (1:1) to either the Resolute Onyx or the Orsiro stent. Randomisation was stratified by sex and diabetes status. Patients and assessors were masked to allocated stents, but treating clinicians were not. The primary endpoint was target vessel failure at 1 year, a composite of cardiac death, target-vessel-related myocardial infarction, and target vessel revascularisation, and was assessed by intention to treat (non-inferiority margin 2·5%) on the basis of outcomes adjudicated by an independent event committee. This trial is registered with ClinicalTrials.gov, number NCT02508714. FINDINGS: Between Oct 7, 2015, and Dec 23, 2016, 2516 patients were enrolled, 2488 of whom were included in the intention-to-treat analysis (28 withdrawals or screening failures). 1243 participants were assigned to the Resolute Onyx group, and 1245 to the Orsiro group. Overall, 1765 (70·9%) participants presented with acute coronary syndromes and 1275 (51·2%) had myocardial infarctions. 1-year follow-up was available for 2478 (99·6%) patients. The primary endpoint was met by 55 (4·5%) patients in the Resolute Onyx group and 58 (4·7%) in the Orsiro group. Non-inferiority of Resolute Onyx to Orsiro was thus established (absolute risk difference -0·2% [95% CI -1·9 to 1·4]; upper limit of the one-sided 95% CI 1·1%; pnon-inferiority=0·0005). Definite or probable stent thrombosis occurred in one (0·1%) participant in the Resolute Onyx group and nine (0·7%) in the Orsiro group (hazard ratio 0·11 [95% CI 0·01-0·87]; p=0·0112). INTERPRETATION: The Resolute Onyx stent was non-inferior to Orsiro for a combined safety and efficacy endpoint at 1-year follow-up in allcomers. The low event rate in both groups suggests that both stents are safe, and the very low rate of stent thrombosis in the Resolute Onyx group warrants further clinical investigation. FUNDING: Biotronik and Medtronic.


Assuntos
Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Desenho de Prótese , Implantes Absorvíveis , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas de Cromo , Stents Farmacológicos/efeitos adversos , Estudos de Equivalência como Asunto , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
12.
Am Heart J ; 198: 25-32, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29653644

RESUMO

AIM: The aim was to compare in a noninferiority trial the efficacy and safety of 2 contemporary drug-eluting stents (DESs): a novel, durable polymer-coated stent versus an established bioabsorbable polymer-coated stent. METHODS AND RESULTS: The BIONYX trial (ClinicalTrials.gov-no.NCT02508714) is an investigator-initiated, prospective, randomized, patient- and assessor-blinded, international, multicenter study in all-comer patients with all types of clinical syndromes and lesions who require percutaneous coronary interventions with DES. Patients at 7 study sites in the Netherlands, Belgium, and Israel were randomly assigned (1:1, stratified for gender and diabetes mellitus) to treatment with the novel, zotarolimus-eluting, durable polymer-coated Resolute Onyx stent that has a radiopaque, thin-strut, CoreWire stent platform versus the sirolimus-eluting, bioresorbable polymer-coated Orsiro stent (reference device) that has a very thin-strut, cobalt-chromium stent backbone. The primary end point is the 1-year incidence of the composite clinical end point target vessel failure consisting of cardiac death, target vessel-related myocardial infarction, or clinically indicated target vessel revascularization. A power calculation, assuming a target vessel failure rate of 6.0% (noninferiority margin 2.5%), revealed that 2,470 study patients would give the study 80% power (α level 5%), allowing for up to 3% loss to follow-up. The first patient was enrolled on October 7, 2015; on December 23, 2016, the last patient entered the study. CONCLUSIONS: BIONYX is a large-scale, prospective, randomized, international, multicenter trial comparing a novel DES with durable coating versus a reference DES with biodegradable coating in all-comers. The study is the first randomized assessment of the Resolute Onyx stent, which is an often-used DES outside the United States.


Assuntos
Implantes Absorvíveis , Estenose Coronária/cirurgia , Stents Farmacológicos , Everolimo/farmacologia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Bélgica , Materiais Revestidos Biocompatíveis , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Internacionalidade , Israel , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Países Baixos , Segurança do Paciente/estatística & dados numéricos , Intervenção Coronária Percutânea/métodos , Polímeros , Estudos Prospectivos , Medição de Risco , Método Simples-Cego , Sirolimo/farmacologia , Estatísticas não Paramétricas , Taxa de Sobrevida , Resultado do Tratamento
13.
Cardiovasc Drugs Ther ; 32(6): 567-576, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30143879

RESUMO

PURPOSE: Patients with high bleeding risk (HBR) who undergo percutaneous coronary intervention also have an increased risk of ischemic events and represent an overall high-risk population. The coating of durable polymer drug-eluting stents (DP-DES) may induce inflammation and delay arterial healing, which might be reduced by novel biodegradable polymer DES (BP-DES). We aimed to evaluate the safety and efficacy of treating HBR patients with very thin-strut BP-DES versus thin-strut DP-DES. METHODS: Participants in BIO-RESORT (NCT01674803), an investigator-initiated multicenter, randomized all-comers trial, were treated with very thin-strut BP-DES (Synergy or Orsiro) or thin-strut DP-DES (Resolute Integrity). For the present analysis, patients were classified following HBR criteria based on previous trials. The primary endpoint was target vessel failure: a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization at 1 year. RESULTS: Of all 3514 patients, 1009 (28.7%) had HBR. HBR patients were older (p < 0.001) and had more co-morbidities than non-HBR patients (p < 0.001). At 1-year follow-up, HBR patients had significantly higher rates of target vessel failure (6.7 vs. 4.2%, p = 0.003), cardiac death (1.9 vs. 0.4%, p < 0.001), and major bleeding (3.3 vs. 1.5%, p = 0.001). Of all 1009 HBR patients, 673 (66.7%) received BP-DES and 336 (33.3%) had DP-DES. The primary endpoint was met by 43/673 (6.5%) patients treated with BP-DES and 24/336 (7.3%) treated with DP-DES (HR 0.88 [95%CI 0.54-1.46], p = 0.63). There were no significant between-group differences in the most global patient-oriented clinical endpoint (9.7 vs. 10.5%, HR 0.92 [95%CI 0.61-1.39], p = 0.69) and other secondary endpoints. CONCLUSIONS: At 1-year follow-up, very thin-strut BP-DES showed similar safety and efficacy for treating HBR patients as thin-strut DP-DES.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Hemorragia/induzido quimicamente , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/efeitos adversos , Polímeros/química , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Hemorragia/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
14.
Heart Vessels ; 33(9): 978-985, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29541845

RESUMO

Knowledge about the changes in endothelial function after ST-elevation myocardial infarction (STEMI) is of substantial interest, but serial data are scarce. The aim of the present study was to noninvasively evaluate whether endothelial function, as assessed shortly after primary percutaneous coronary intervention (PPCI) for STEMI, may improve until 12-month follow-up. This prospective observational cohort study was performed in patients in the RESPONSE randomized trial who participated in a substudy and underwent noninvasive assessment of endothelial function at 1 (baseline), 6, and 12-month follow-up after treatment of a STEMI by PPCI. The reactive hyperemia peripheral artery tonometry (RH-PAT) method was used to assess endothelial function (higher RH-PAT index signifies better function). Of the 70 study participants, who were 57.4 ± 9.7 years of age, 55 (78.6%) were male and 9 (13%) had diabetes. The endothelial function deteriorated significantly during follow-up: the RH-PAT index at baseline, 6, and 12-month follow-up was 1.90 ± 0.58, 1.81 ± 0.57, and 1.69 ± 0.49, respectively (p = 0.04). Although patients were carefully treated in outpatient clinics and adequate pharmacological therapy was prescribed, we noted an increase in total cholesterol (p = 0.001), LDL cholesterol (p = 0.002), HbA1C (p = 0.054), and diastolic blood pressure (p = 0.047) However, multivariate analysis revealed that this increase in cardiovascular risk factors could not explain the observed deterioration in endothelial function. In patients with STEMI, we observed a significant deterioration in endothelial function during 12 months after PPCI that could not be explained by changes in the traditional cardiovascular risk profile.


Assuntos
Artérias/fisiopatologia , Endotélio Vascular/fisiopatologia , Hiperemia/fisiopatologia , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Vasodilatação/fisiologia , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pletismografia , Período Pós-Operatório , Prognóstico , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Fatores de Tempo
15.
Lancet ; 388(10060): 2607-2617, 2016 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-27806902

RESUMO

BACKGROUND: In patients with coronary artery disease, treated with durable polymer-coated drug-eluting stents, the life-long presence of the polymer might delay arterial healing. Novel very thin strut biodegradable polymer stents, which leave only a bare metal stent after polymer resorption, might improve long-term outcome. We investigated in allcomers the safety and efficacy of three stents eluting either everolimus, sirolimus, or zotarolimus, often clinically used but never compared, of which the biodegradable polymer everolimus-eluting stent was never before assessed in allcomers. METHODS: The large-scale, investigator-initiated, multicentre, assessor and patient blinded, three-arm, randomised, BIO-RESORT non-inferiority trial was done at four clinical sites in the Netherlands. All-comer patients were aged 18 years or older, capable of providing informed consent, and required a percutaneous coronary intervention with drug-eluting stent implantation according to clinical guidelines or the operators' judgment. Exclusion criteria were: participation in another randomised drug or device study before reaching the primary endpoint of that study; planned surgery necessitating interruption of dual antiplatelet therapy within the first 6 months; known intolerance to components of the investigational product or medication required; uncertainty about the adherence to follow-up procedures or an assumed life expectancy of less than 1 year; or known pregnancy. Web-based computer-generated allocation sequences randomly assigned patients (1:1:1) to treatment with very thin strut biodegradable polymer everolimus-eluting or sirolimus-eluting stents (which differ substantially in type, amount, distribution, and resorption speed of their respective coating), or thin strut durable polymer zotarolimus-eluting stents. The primary endpoint was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (target vessel revascularisation) at 12 months of follow up with a very thin strut biodegradable polymer of either everolimus-eluting or sirolimus-eluting stents, compared with durable polymer zotarolimus-eluting stents, analysed by intention to treat (non-inferiority margin 3·5%). This trial was registered with ClinicalTrials.gov, number NCT01674803. FINDINGS: From Dec 21, 2012, to Aug 24, 2015, 3514 patients were enrolled and analysed, of whom 2449 (70%) had acute coronary syndromes, which included 1073 (31%) ST-elevation myocardial infarctions. 12 month follow-up of 3490 (99%) patients (three lost to follow-up; 21 withdrawals) was available. The primary endpoint was met by 55 (5%) of 1172 patients assigned to everolimus-eluting stents, 55 (5%) of 1169 assigned to sirolimus-eluting stents and 63 (5%) of 1173 assigned to zotarolimus-eluting stents. Non-inferiority of the everolimus-eluting stents and sirolimus-eluting stents compared with zotarolimus-eluting stents was confirmed (both -0·7% absolute risk difference, 95% CI -2·4 to 1·1; upper limit of one sided 95% CI 0·8%, pnon-inferiority<0·0001). Definite stent thrombosis (defined by the Academic Research Consortium) occurred in four (0·3%) of 1172 patients who were allocated to everolimus-eluting stents, four (0·3%) of 1169 patients who were allocated to sirolimus-eluting stents, and three (0·3%) of 1173 patients who were allocated to zotarolimus-eluting stents (log-rank p=0·70 for both comparisons with zotarolimus-eluting stents). INTERPRETATION: At 12 month follow-up, both very thin strut drug-eluting stents with dissimilar biodegradable polymer coatings (eluting either everolimus or sirolimus) were non-inferior to the durable polymer stent (eluting zotarolimus) in treating allcomers with a high proportion of patients with acute coronary syndromes. The absence of a loss of 1 year safety and efficacy with the use of these two biodegradable polymer-coated stents is a prerequisite before assessing their potential longer-term benefits. FUNDING: Biotronik, Boston Scientific, and Medtronic.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Antibacterianos/uso terapêutico , Stents Farmacológicos , Everolimo , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Implantes Absorvíveis , Idoso , Antibacterianos/administração & dosagem , Doença das Coronárias/cirurgia , Feminino , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Polímeros , Sirolimo/administração & dosagem , Sirolimo/análise , Resultado do Tratamento
17.
Atherosclerosis ; 392: 117488, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598970

RESUMO

BACKGROUND AND AIMS: Previous studies in percutaneous coronary intervention (PCI) patients showed a higher 3-year adverse event risk, including all-cause mortality, in those with concomitant peripheral arterial disease (PADs). Ten-year data of mortality and causes of death are scarce. This analysis assessed PCI patients, treated with contemporary drug-eluting stents, the impact of concomitant PADs on very long-term mortality, and causes of death. METHODS: We assessed PCI all-comers from our center who participated in the TWENTE and DUTCH PEERS trials (clinicaltrials.gov:NCT01066650, NCT01331707), comparing patients with versus without PADs. Life status was checked in the Dutch Personal Records Database; causes of death were obtained from medical records. RESULTS: Of 2705 study patients, 668 (24.7%) died during follow-up: 88/212 (41.5%) patients with PADs and 580/2493 (23.1%) without PADs. In PADs patients, the 10-year rate of all-cause mortality was about twice as high as in patients without PADs (41.5% vs.23.1%, HR: 2.05, 95%-CI: 1.64-2.57, p<0.001). For both groups, the rates of patients dying from various causes of death were: cardiac (14.1% vs.6.8%), vascular (2.8% vs. 1.1%), non-cardiovascular (17.4% vs. 9.8%), and unclear causes (7.1% vs. 5.3%), without a statistically significant between-group difference. When multivariate analysis was adjusted for between-group differences in cardiovascular risk profile, PADs remained predictor of all-cause mortality (adjusted HR: 1.38, 95%-CI: 1.08-1.75, p=0.01). CONCLUSIONS: The 10-year all-cause mortality rate in PCI patients with concomitant PADs was almost twice as high as in those without PADs. Age and other traditional cardiovascular risk factors were higher in patients with PADs, but after correction for these confounders PADs still accounted for almost 40% increase in mortality.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença Arterial Periférica , Humanos , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/terapia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Fatores de Tempo , Resultado do Tratamento , Fatores de Risco , Países Baixos/epidemiologia , Causas de Morte
18.
Front Cardiovasc Med ; 10: 1160201, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745109

RESUMO

Objectives: We assessed differences in risk profile and 3-year outcome between patients undergoing percutaneous coronary intervention (PCI) for premature and non-premature coronary artery disease (CAD). Background: The prevalence of CAD increases with age, yet some individuals develop obstructive CAD at younger age. Methods: Among participants in four randomized all-comers PCI trials, without previous coronary revascularization or myocardial infarction (MI), we compared patients with premature (men <50 years; women <55 years) and non-premature CAD. Various clinical endpoints were assessed, including multivariate analyses. Results: Of 6,171 patients, 887 (14.4%) suffered from premature CAD. These patients had fewer risk factors than patients with non-premature CAD, but were more often smokers (60.7% vs. 26.4%) and overweight (76.2% vs. 69.8%). In addition, premature CAD patients presented more often with ST-segment elevation MI and underwent less often treatment of multiple vessels, and calcified or bifurcated lesions. Furthermore, premature CAD patients had a lower all-cause mortality risk (adj.HR: 0.23, 95%-CI: 0.10-0.52; p < 0.001), but target vessel revascularization (adj.HR: 1.63, 95%-CI: 1.18-2.26; p = 0.003) and definite stent thrombosis risks (adj.HR: 2.24, 95%-CI: 1.06-4.72; p = 0.034) were higher. MACE rates showed no statistically significant difference (6.6% vs. 9.4%; adj.HR: 0.86, 95%-CI: 0.65-1.16; p = 0.33). Conclusions: About one out of seven PCI patients was treated for premature CAD. These patients had less complex risk profiles than patients with non-premature CAD; yet, their risk of repeated revascularization and stent thrombosis was higher. As lifetime event risk of patients with premature CAD is known to be particularly high, further efforts should be made to improve modifiable risk factors such as smoking and overweight. TWENTE trials: (TWENTE I, clinicaltrials.gov: NCT01066650), DUTCH PEERS (TWENTE II, NCT01331707), BIO-RESORT (TWENTE III, NCT01674803), and BIONYX (TWENTE IV, NCT02508714).

19.
Int J Cardiol ; 374: 27-32, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36496036

RESUMO

BACKGROUND: Both patients with obstructive coronary artery disease (CAD) and patients with peripheral arterial disease (PADs) have an increased bleeding risk. Information is scarce on bleeding in CAD patients, treated with percutaneous coronary intervention (PCI), who have comorbid PADs. We assessed whether PCI patients with PADs have a higher bleeding risk than PCI patients without PADs. Furthermore, in PCI patients with PADs we evaluated the extent by which bleeding increased the risk of further adverse events. METHODS: Three-year pooled patient-level data of two randomized PCI trials (BIO-RESORT, BIONYX) with drug-eluting stents were analyzed to assess mortality and the composite endpoint major adverse cardiac events (MACE: all-cause mortality, any myocardial infarction, emergent coronary artery bypass surgery, or target lesion revascularization). RESULTS: Among 5989 all-comer patients, followed for 3 years, bleeding occurred in 7.7% (34/440) with comorbid PADs and 5.0% (279/5549) without PADs (HR: 1.59, 95%CI: 1.11-2.23, p = 0.010). Of all PADs patients, those with a bleeding had significantly higher rates of all-cause mortality (HR: 4.70, 95%CI: 2.37-9.33, p < 0.001) and MACE (HR: 2.39, 95%CI: 1.23-4.31, p = 0.003). Furthermore, PADs patients with a bleeding were older (74.4 ± 6.9 vs. 67.4 ± 9.5, p < 0.001). After correction for age and other potential confounders, bleeding remained independently associated with all-cause mortality (adj.HR: 2.97, 95%CI: 1.37-6.43, p = 0.006) while the relation of bleeding with MACE became borderline non-significant (adj.HR: 1.85, 95%CI: 0.97-3.55, p = 0.06). CONCLUSION: PCI patients with PADs had a higher bleeding risk than PCI patients without PADs. In PADs patients, bleeding was associated with all-cause mortality, even after adjustment for potential confounders.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Doença Arterial Periférica , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Hemorragia/diagnóstico , Hemorragia/epidemiologia , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/epidemiologia , Doença Arterial Periférica/cirurgia , Resultado do Tratamento
20.
Cardiovasc Diagn Ther ; 13(4): 673-685, 2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37675090

RESUMO

Background: In patients with peripheral arterial disease (PADs), who underwent percutaneous coronary intervention (PCI), little is known about the potential impact of using different new-generation drug-eluting stents (DES) on outcome. In PCI all-comers, the results of most between-stent comparisons-stratified by strut thickness-suggested some advantage of coronary stents with ultrathin-struts. The current post-hoc analysis aimed to assess outcomes of PCI with ultrathin-strut biodegradable polymer sirolimus-eluting stents (BP-SES) vs. thin-strut durable polymer zotarolimus-eluting stents (DP-ZES) in patients with PADs. Methods: We pooled 3-year patient-level data from two large-scale randomized all-comer trials to compare Orsiro ultrathin-strut BP-SES vs. Resolute-type thin-strut DP-ZES in trial participants with concomitant PADs. BIO-RESORT (December 2012 to August 2015) and BIONYX (October 2015 to December 2016) included all-comer patients who were aged 18 years or older, capable of providing informed consent, and required a PCI. The trials had web-based randomization, with block sizes of 4 and 8, performed in a 1:1:1 or 1:1 fashion. Assessors, research staff, and patients were blinded to the type of stent used. We assessed the composite main clinical endpoint target vessel failure [TVF: cardiac death, target vessel related myocardial infarction (MI), or clinically indicated target vessel revascularization (TVR)], its components, and stent thrombosis. Results: Of 4,830 trial participants, 360 had PADs: 177 (49.2%) were treated with BP-SES and 183 (50.8%) with DP-ZES. Baseline characteristics were similar. For BP-SES, the 3-year TVF rate was 11.0% and for DP-ZES 17.9% [hazard ratio (HR): 0.59, 95% CI: 0.33-1.04; P=0.07]. For BP-SES, the TVR rate was lower than for DP-ZES (4.1% vs. 11.0%; HR: 0.36, 95% CI: 0.15-0.86; P=0.016), but this did not translate into between-group differences in cardiac death or MI. In small vessels (<2.75 mm), the TVR rate was also lower in BP-SES (5.6% vs. 13.9%; HR: 0.32, 95% CI: 0.11-0.91; P=0.024). Definite-or-probable stent thrombosis rates were 1.2% and 2.3% (P=0.43). Conclusions: In PCI patients with PADs, the 3-year TVF incidence was numerically lower in the ultrathin-strut BP-SES vs. the thin-strut DP-ZES group. Furthermore, TVR risk was significantly lower in ultrathin-strut BP-SES, mainly driven by a lower TVR rate in small vessels. Trial Registration: BIO-RESORT trial: clinicaltrials.gov (NCT01674803); BIONYX trial: clinicaltrials.gov (NCT02508714).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA