Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 14: 37, 2012 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-22704222

RESUMO

BACKGROUND: Late gadolinium enhanced (LGE) cardiovascular magnetic resonance (CMR) is frequently used to evaluate myocardial viability, estimate total infarct size and transmurality, but is not always straightforward is and contraindicated in patients with renal failure because of the risk of nephrogenic systemic fibrosis. T2- and T1-weighted CMR alone is however relatively insensitive to chronic myocardial infarction (MI) in the absence of a contrast agent. The objective of this manuscript is to explore T1ρ-weighted rotating frame CMR techniques for infarct characterization without contrast agents. We hypothesize that T1ρ CMR accurately measures infarct size in chronic MI on account of a large change in T1ρ relaxation time between scar and myocardium. METHODS: 7Yorkshire swine underwent CMR at 8 weeks post-surgical induction of apical or posterolateral myocardial infarction. Late gadolinium enhanced and T1ρ CMR were performed at high resolution to visualize MI. T1ρ-weighted imaging was performed with a B1 = 500 Hz spin lock pulse on a 3 T clinical MR scanner. Following sacrifice, the heart was excised and infarct size was calculated by optical planimetry. Infarct size was calculated for all three methods (LGE, T1ρ and planimetry) and statistical analysis was performed. T1ρ relaxation time maps were computed from multiple T1ρ-weighted images at varying spin lock duration. RESULTS: Mean infarct contrast-to-noise ratio (CNR) in LGE and T1ρ CMR was 2.8 ± 0.1 and 2.7 ± 0.1. The variation in signal intensity of tissues was found to be, in order of decreasing signal intensity, LV blood, fat and edema, infarct and healthy myocardium. Infarct size measured by T1ρ CMR (21.1% ± 1.4%) was not significantly different from LGE CMR (22.2% ± 1.5%) or planimetry (21.1% ± 2.7%; p < 0.05).T1ρ relaxation times were T1ρinfarct = 91.7 ms in the infarct and T1ρremote = 47.2 ms in the remote myocardium. CONCLUSIONS: T1ρ-weighted imaging using long spin locking pulses enables high discrimination between infarct and myocardium. T1ρ CMR may be useful to visualizing MI without the need for exogenous contrast agents for a wide range of clinical cardiac applications such as to distinguish edema and scar tissue and tissue characterization of myocarditis and ventricular fibrosis.


Assuntos
Ventrículos do Coração/patologia , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica/fisiologia , Infarto do Miocárdio/patologia , Miocárdio/patologia , Animais , Doença Crônica , Meios de Contraste/administração & dosagem , Modelos Animais de Doenças , Seguimentos , Ventrículos do Coração/fisiopatologia , Injeções Intravenosas , Imagem Cinética por Ressonância Magnética/efeitos adversos , Meglumina/administração & dosagem , Infarto do Miocárdio/fisiopatologia , Reprodutibilidade dos Testes , Suínos
2.
Cell Metab ; 30(3): 594-606.e3, 2019 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-31257152

RESUMO

Mammalian organs continually exchange metabolites via circulation, but systems-level analysis of this shuttling process is lacking. Here, we compared, in fasted pigs, metabolite concentrations in arterial blood versus draining venous blood from 11 organs. Greater than 90% of metabolites showed arterial-venous differences across at least one organ. Surprisingly, the liver and kidneys released not only glucose but also amino acids, both of which were consumed primarily by the intestine and pancreas. The liver and kidneys exhibited additional unexpected activities: liver preferentially burned unsaturated over more atherogenic saturated fatty acids, whereas the kidneys were unique in burning circulating citrate and net oxidizing lactate to pyruvate, thereby contributing to circulating redox homeostasis. Furthermore, we observed more than 700 other cases of tissue-specific metabolite production or consumption, such as release of nucleotides by the spleen and TCA intermediates by pancreas. These data constitute a high-value resource, providing a quantitative atlas of inter-organ metabolite exchange.


Assuntos
Rim/metabolismo , Fígado/metabolismo , Suínos/metabolismo , Aminoácidos/sangue , Animais , Artérias , Glicemia , Ácido Cítrico/sangue , Jejum/sangue , Ácidos Graxos/sangue , Mucosa Intestinal/irrigação sanguínea , Mucosa Intestinal/metabolismo , Rim/irrigação sanguínea , Ácido Láctico/sangue , Fígado/irrigação sanguínea , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Pâncreas/irrigação sanguínea , Pâncreas/metabolismo , Ácido Pirúvico/sangue , Baço/irrigação sanguínea , Baço/metabolismo , Veias
4.
Innovations (Phila) ; 9(1): 16-21, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24562291

RESUMO

OBJECTIVE: Despite advances in design, modern ventricular assist device placement involves median sternotomy and cardiopulmonary bypass and is associated with infectious/embolic complications. In this study, we examine the feasibility and function of a novel minimally invasive, non-blood-contacting epicardial assist device in a porcine ischemic cardiomyopathy model. METHODS: Feasibility was first tested in an ex vivo thoracoscopic trainer box with slaughterhouse hearts. Five male Yorkshire swine underwent selective ligation of the circumflex artery to create a posterolateral infarct Twelve weeks after infarct, all animals underwent left minithoracotomy. A custom inflatable bladder was positioned over the epicardial surface of the infarct and firmly secured to the surrounding border zone myocardium with polypropylene mesh and minimally invasive mesh tacks. An external gas pulsation system actively inflated and deflated the bladder in synchrony with the cardiac cycle. All animals then underwent cardiac magnetic resonance imaging to assess ventricular function. RESULTS: All subjects successfully underwent off-pump placement of the epicardial assist device via minithoracotomy. Ejection fraction significantly improved from 29.1% ± 4.8% to 39.6% ± 4.23% (P < 0.001) when compared with pretreatment. End-systolic volume decreased (76.6 ± 13.3 mL vs 62.4 ± 12.0 mL, P < 0.001) and stroke volume increased (28.6 ± 3.4 mL vs 37.9 ± 3.1 mL, P < 0.05) when assisted. No change was noted in end-diastolic volume (105.1 ± 11.4 vs 100.3 ± 12.7). On postmortem examination, mesh fixation and device position were excellent in all cases. No adverse events were encountered. CONCLUSIONS: Directed epicardial assistance improves ventricular function in a porcine ischemic cardiomyopathy model and may provide a safe alternative to currently available ventricular assist device therapies. Further, the technique used for device positioning and fixation suggests that an entirely thoracoscopic approach is possible.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Toracoscopia/métodos , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Imagem Cinética por Ressonância Magnética , Masculino , Pericárdio , Desenho de Prótese , Volume Sistólico , Suínos , Função Ventricular Esquerda
5.
Nat Med ; 20(2): 209-14, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24412924

RESUMO

ATP derived from the conversion of phosphocreatine to creatine by creatine kinase provides an essential chemical energy source that governs myocardial contraction. Here, we demonstrate that the exchange of amine protons from creatine with protons in bulk water can be exploited to image creatine through chemical exchange saturation transfer (CrEST) in myocardial tissue. We show that CrEST provides about two orders of magnitude higher sensitivity compared to (1)H magnetic resonance spectroscopy. Results of CrEST studies from ex vivo myocardial tissue strongly correlate with results from (1)H and (31)P magnetic resonance spectroscopy and biochemical analysis. We demonstrate the feasibility of CrEST measurement in healthy and infarcted myocardium in animal models in vivo on a 3-T clinical scanner. As proof of principle, we show the conversion of phosphocreatine to creatine by spatiotemporal mapping of creatine changes in the exercised human calf muscle. We also discuss the potential utility of CrEST in studying myocardial disorders.


Assuntos
Creatina Quinase/metabolismo , Creatina/metabolismo , Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Contração Miocárdica/fisiologia , Miocárdio/enzimologia , Trifosfato de Adenosina/biossíntese , Humanos , Músculo Esquelético/metabolismo , Prótons , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA