Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Microorganisms ; 10(4)2022 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-35456832

RESUMO

While numerous approaches have meanwhile been described, sufficient disinfection of root canals is still challenging, mostly due to limited access and the porous structure of dentin. Instead of using different rinsing solutions and activated irrigation, the electrolysis of saline using boron-doped diamond (BDD) electrodes thereby producing reactive oxygen species may be an alternative approach. In a first step, experiments using extracted human teeth incubated with multispecies bacterial biofilm were conducted. The charge quantities required for electrochemical disinfection of root canals were determined, which were subsequently applied in an animal trial using an intraoral canine model. It could be shown that also under realistic clinical conditions, predictable disinfection of root canals could be achieved using BDD electrodes. The parameters required are in the range of 5.5 to 7.0 V and 9 to 38 mA, applied for 2.5 to 6.0 min with approximately 5 to 8 mL of saline. The direct generation of disinfective agents inside the root canal seems to be advantageous especially in situations with compromised access and limited canal sizes. The biologic effect with respect to the host reaction on BDD-mediated disinfection is yet to be examined.

2.
J Clin Med ; 9(9)2020 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-32967183

RESUMO

No proper treatment option for peri-implantitis exists yet. Based on previous studies showing the in vitro effectiveness of electrochemical disinfection using boron-doped diamond electrodes, novel double diamond electrodes (DDE) were tested here. Using a ceramic carrier and a laser structuring process, a clinically applicable electrode array was manufactured. Roughened metal discs (n = 24) made from Ti-Zr alloy were exposed to the oral cavities of six volunteers for 24 h in order to generate biofilm. Then, biofilm removal was carried out either using plastic curettes and chlorhexidine digluconate or electrochemical disinfection. In addition, dental implants were contaminated with ex vivo multispecies biofilm and disinfected using DDE treatment. Bacterial growth and the formation of biofilm polymer were determined as outcome measures. Chemo-mechanical treatment could not eliminate bacteria from roughened surfaces, while in most cases, a massive reduction of bacteria and biofilm polymer was observed following DDE treatment. Electrochemical disinfection was charge- and time-dependent and could also not reach complete disinfection in all instances. Implant threads had no negative effect on DDE treatment. Bacteria exhibit varying resistance to electrochemical disinfection with Bacillus subtilis, Neisseria sp., Rothiamucilaginosa, Staphylococcus haemolyticus, and Streptococcus mitis surviving 5 min of DDE application at 6 V. Electrochemical disinfection is promising but requires further optimization with respect to charge quantity and application time in order to achieve disinfection without harming host tissue.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA