Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Multidiscip Respir Med ; 14: 34, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31827794

RESUMO

BACKGROUND: Data show that the initial specialist's image interpretation and final multidisciplinary tumor board (MTB) assessment can vary substantially in the pretherapeutic cancer setting. The aim of this post hoc analysis was to investigate the concordance of the specialist's and MTB's image interpretations in patients undergoing systematic posttreatment lung cancer image surveillance. METHODS: In the initial prospective study, lung cancer patients who had received curative-intent treatment were randomly assigned to undergo either contrast-enhanced computed tomography (CE-CT) or integrated 18F-fluorodeoxyglucose positron emission tomography-computed tomography (PET-CT). Imaging was performed every 6 months for 2 years, and all imaging studies were finally assessed by our MTB. This post hoc analysis assessed differences between the initial specialist's image interpretation and the final MTB's image interpretation. RESULTS: In 89 patients, 266 imaging studies (129 PET-CT, 137 CE-CT) were analyzed. In 87.2% (88.4, 86.1%) of the studies, complete concordance was found. Out of the 12.8% (11.6, 13.9%) with discordant results, 7.5% (6.9, 8.0%) had implications for alterations in patient management (major disagreements).Twenty major disagreements were detected in 17 study patients. Retrospectively, in eight out of these 17 (47%) patients, in contrast to the MTB's view, the specialist's interpretation was more appropriate, whereas in nine out of 17 patients (53%), the MTB's interpretation was more accurate. CONCLUSIONS: In an experienced MTB, the agreement between imaging specialists and the rest of the MTB with regard to the interpretation of images is high in a setting of posttreatment lung cancer image surveillance. It seems that in cases of disagreements, the rates of more accurate interpretation are well balanced between imaging specialists and the MTB. TRIAL REGISTRATION: ISRCTN16281786, Date 23. February 2017.

2.
Ann Thorac Surg ; 107(2): 430-435, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30292847

RESUMO

BACKGROUND: Scientific data on the image modality to be used in postcurative treatment surveillance of non-small cell lung cancer patients are scarce. This prospective randomized pilot trial compared the performance of integrated 18F-fluorodeoxyglucose positron emission tomography-computed tomography (PET-CT) and contrast-enhanced computed tomography (CE-CT). METHODS: After termination of curative-intent treatment, patients were randomly assigned to the PET-CT or the CE-CT group. Imaging was performed every 6 months for 2 years. If suspicious radiologic findings were detected or patients became symptomatic, a diagnostic workup was initiated. Sensitivity, specificity, and positive predictive value for detecting cancer recurrence were calculated for both imaging procedures. RESULTS: The study enrolled 96 patients. In 14 of 50 patients (28%) in the PET-CT group and in 14 of 46 patients (30%) in the CE-CT group, a suspicious radiologic finding was confirmed as cancer recurrence after diagnostic workup. False-positive findings were detected in 11 patients (22%) of the PET-CT group and in 8 patients (17%) of the CE-CT group. The sensitivity, specificity, and positive predictive value for detecting cancer recurrence (95% confidence interval) were 0.88 (0.62 to 0.98), 0.62 (0.42 to 0.79), and 0.56 (0.35 to 0.76) for PET-CT and 0.93 (0.68 to 1.00), 0.72 (0.53 to 0.87), and 0.64 (0.41to 0.83) for CE-CT, respectively. CONCLUSIONS: The results of our study suggest that PET-CT is not superior to CE-CT in detecting cancer recurrence during 2 years after curative-intent treatment of non-small cell lung cancer.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Fluordesoxiglucose F18/farmacologia , Neoplasias Pulmonares/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Carcinoma Pulmonar de Células não Pequenas/terapia , Terapia Combinada , Feminino , Seguimentos , Humanos , Incidência , Neoplasias Pulmonares/terapia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico , Recidiva Local de Neoplasia/epidemiologia , Projetos Piloto , Prognóstico , Estudos Prospectivos , Compostos Radiofarmacêuticos/farmacologia , Reprodutibilidade dos Testes , Suíça/epidemiologia
3.
Virchows Arch ; 475(1): 67-76, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31127385

RESUMO

With the approval of pembrolizumab for first- and second-line treatment of PD-L1+ non-small cell lung cancer (NSCLC), PD-L1 testing by immunohistochemistry (IHC) has become a necessity. However, the DAKO autostainer ASL48 for the FDA approved DAKO 22C3 pharmDx assay is not broadly available in Switzerland and other parts of Europe. The primary goal of this study was to cross-validate the 22C3 anti-PD-L1 antibody on Benchmark Ultra (VBMU) and Leica Bond (LBO) immunostainers. IHC protocols were developed for 22C3 on both platforms with the 22C3phDx using ASL48 as reference. A tissue microarray (TMA) was constructed from 23 NSCLC specimens with a range of PD-L1 staining results. Empty TMA sections and the 22C3 antibody were distributed to 16 participants for staining on VBMU (8 centers) and/or LBO (12 centers) using the centrally developed protocols. Additionally the performance of the Ventana SP263 assay was tested in five centers. IHC scoring was performed centrally. Categorical PD-L1 staining (0-49% vs. 50-100%) did not significantly differ between centers using VBMU, whereas data from LBO were highly variable (p < 0.001). The SP263 assay was well concordant with 22C3 on VBMU and with 22C3 pharmDx. PD-L1 IHC using a standardized 22C3 protocol on VBMU provides satisfactory results in most centers. The SP263 assay is confirmed as a valid alternative to 22C3 pharmDx. 22C3 PD-L1 IHC on LBO shows major staining variability between centers, highlighting the need for local validation and adjustment of protocols.


Assuntos
Anticorpos/imunologia , Antígeno B7-H1/análise , Biomarcadores Tumorais/análise , Carcinoma Pulmonar de Células não Pequenas/química , Imuno-Histoquímica/métodos , Neoplasias Pulmonares/química , Automação Laboratorial , Carcinoma Pulmonar de Células não Pequenas/imunologia , Carcinoma Pulmonar de Células não Pequenas/patologia , Humanos , Imuno-Histoquímica/instrumentação , Imuno-Histoquímica/normas , Neoplasias Pulmonares/imunologia , Neoplasias Pulmonares/patologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Suíça , Análise Serial de Tecidos
4.
Lung Cancer ; 76(3): 493-5, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22420949

RESUMO

In contrast to leukocytosis, paraneoplastic hypereosinophilia is uncommon in lung cancer. We present a patient with large-cell carcinoma of the lung, in which cancer cells generate large amounts of GM-CSF leading to a leukemoid reaction with prominent hypereosinophilia and potentially involved in autocrine tumor stimulation.


Assuntos
Carcinoma de Células Grandes/complicações , Carcinoma de Células Grandes/metabolismo , Eosinofilia/etiologia , Fator Estimulador de Colônias de Granulócitos/sangue , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/metabolismo , Carcinoma de Células Grandes/tratamento farmacológico , Eosinofilia/diagnóstico , Evolução Fatal , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Masculino , Pessoa de Meia-Idade
5.
Radiology ; 235(2): 623-8, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15858102

RESUMO

Institutional review board approval and written informed consent were obtained. Patients with newly diagnosed prostate cancer and patients suspected of having recurrent prostate cancer were prospectively evaluated with fluorine 18 fluorocholine (FCH) combined in-line positron emission tomography (PET) and computed tomography (CT). In 19 patients (mean age, 67 years +/- 8; range, 57-85 years), standardized uptake values of FCH in 17 different tissues were determined by using volumes of interest. In nine patients evaluated at initial staging, histologic findings of the resected prostate were compared to FCH uptake. Only small variations of physiologic tracer accumulation were measured in all organs but the kidneys. Differentiation of benign hyperplasia from cancerous prostate lesions was not possible with FCH PET/CT. However, in patients with recurrent prostate cancer, FCH PET/CT is a promising imaging modality for detecting local recurrence and lymph node metastases.


Assuntos
Adenocarcinoma/diagnóstico , Radioisótopos de Flúor , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Recidiva Local de Neoplasia/diagnóstico , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico , Compostos de Amônio Quaternário , Tomografia Computadorizada por Raios X , Adenocarcinoma/patologia , Adenocarcinoma/secundário , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/patologia , Neoplasias Ósseas/secundário , Radioisótopos de Flúor/farmacocinética , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Neoplasias Pélvicas/diagnóstico , Neoplasias Pélvicas/patologia , Neoplasias Pélvicas/secundário , Próstata/patologia , Neoplasias da Próstata/patologia , Compostos de Amônio Quaternário/farmacocinética , Sensibilidade e Especificidade , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA