Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Genet Med ; 13(3): 230-54, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21325949

RESUMO

PURPOSE: To achieve clinical validation of cutoff values for newborn screening by tandem mass spectrometry through a worldwide collaborative effort. METHODS: Cumulative percentiles of amino acids and acylcarnitines in dried blood spots of approximately 25­30 million normal newborns and 10,742 deidentified true positive cases are compared to assign clinical significance, which is achieved when the median of a disorder range is, and usually markedly outside, either the 99th or the 1st percentile of the normal population. The cutoff target ranges of analytes and ratios are then defined as the interval between selected percentiles of the two populations. When overlaps occur, adjustments are made to maximize sensitivity and specificity taking all available factors into consideration. RESULTS: As of December 1, 2010, 130 sites in 45 countries have uploaded a total of 25,114 percentile data points, 565,232 analyte results of true positive cases with 64 conditions, and 5,341 cutoff values. The average rate of submission of true positive cases between December 1, 2008, and December 1, 2010, was 5.1 cases/day. This cumulative evidence generated 91 high and 23 low cutoff target ranges. The overall proportion of cutoff values within the respective target range was 42% (2,269/5,341). CONCLUSION: An unprecedented level of cooperation and collaboration has allowed the objective definition of cutoff target ranges for 114 markers to be applied to newborn screening of rare metabolic disorders.


Assuntos
Doenças Metabólicas/diagnóstico , Triagem Neonatal , Espectrometria de Massas em Tandem , Aminoácidos/sangue , Carnitina/análogos & derivados , Carnitina/sangue , Humanos , Recém-Nascido , Cooperação Internacional , Valores de Referência , Sensibilidade e Especificidade , Software
2.
JIMD Rep ; 53(1): 90-102, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32395414

RESUMO

BACKGROUND: Nitisinone is used to treat hereditary tyrosinemia type 1 (HT-1) by preventing accumulation of toxic metabolites, including succinylacetone (SA). Accurate quantification of SA during newborn screening is essential, as is quantification of both SA and nitisinone for disease monitoring and optimization of treatment. Analysis of dried blood spots (DBS) rather than plasma samples is a convenient method, but interlaboratory differences and comparability of DBS to serum/plasma may be issues to consider. METHODS: Eight laboratories with experience in newborn screening and/or monitoring of patients with HT-1 across Europe participated in this study to assess variability and improve SA and nitisinone concentration measurements from DBS by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Quantification of nitisinone from both DBS and plasma was performed to assess sample comparability. In addition, efforts to harmonize laboratory procedures of SA and nitisinone quantifications during 5 rounds of analysis are described. RESULTS: Nitisinone levels measured from DBS and plasma strongly correlated (R 2 = 0.93). Due to partitioning of nitisinone to the plasma, levels were higher in plasma by a factor of 2.34. In the initial assessment of laboratory performance, all had linear calibrations of SA and nitisinone although there was large inter-laboratory variability in actual concentration measurements. Subsequent analytical rounds demonstrated markedly improved spread and precision over previous rounds, an outcome confirmed in a final re-test round. CONCLUSION: The study provides guidance for the determination of nitisinone and SA from DBS and the interpretation of results in the clinic. Inter-laboratory analytical harmonization was demonstrated through calibration improvements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA