Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Radiologia (Engl Ed) ; 65(4): 298-306, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37516483

RESUMO

INTRODUCTION: Incorporating coronary computed tomography angiography (CTA) in the hospital workup for suspected acute coronary syndrome requires appropriate skills for interpreting this imaging test. Radiologists' skills can affect the interobserver agreement in evaluating these studies. OBJECTIVE: To determine the interobserver agreement according to radiologists' experience in the interpretation of coronary CTA studies done in patients who present at the emergency department with acute chest pain and low-to-intermediate probability of acute coronary syndrome. MATERIALS AND METHODS: We studied the interobserver agreement in the urgent evaluation of coronary CTA studies in which CAD-RADS was used to register the findings. We created pairs of observers among a total of 8 assessors (4 attending radiologists and 4 radiology residents). We used the kappa coefficient to estimate the overall concordance and the concordance between subgroups according to their experience. RESULTS: The agreement was substantial between experienced radiologists and residents (k=0.627; 95%CI: 0.436-0.826) as well as between all the pairs of observers (k=0.661; 95%CI: 0.506-0.823) for all the CAD-RADS together. The degree of agreement within the group of experienced radiologists was greater than that within the group of residents in all the analyses. The agreement was excellent for the overall CAD-RADS (k=0.950; 95% CI: 0.896-1) and for CAD-RADS ≥ 4 (k=1); the agreement was lower for CAD-RADS ≥ 3 (k=0.754; 95% CI: 0.246-1.255). The agreement for the residents for these categories was k=0.623, k=0.596, and k=0.473, respectively. CONCLUSION: The agreement among attending radiologists regarding the assessment of urgent coronary CTA studies is excellent. The agreement is lower when residents are paired with attending radiologists. These findings should be taken into consideration when implementing coronary CTA in emergency departments and in the organisation of radiological staff for interpreting and reporting this imaging test.


Assuntos
Síndrome Coronariana Aguda , Humanos , Angiografia Coronária/métodos , Emergências , Tomografia Computadorizada por Raios X , Radiologistas
2.
J Hazard Mater ; 385: 121617, 2020 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-31740298

RESUMO

Propagation of emerging pollutants (EPs) in wastewater treatment plants has become a warning sign, especially for novel resource-recovery concepts. The fate of EPs on purple phototrophic bacteria (PPB)-based systems has not yet been determined. This work analyzes the performance of a photo-anaerobic membrane bioreactor treating a low-N wastewater contaminated with 25 EPs. The chemical oxygen demand (COD), N and P removal efficiencies were stable (76 ±â€¯8, 62 ±â€¯15 and 36 ±â€¯8 %, respectively) for EPs loading rate ranging from 50 to 200 ng L-1 d-1. The PPB community adapted to changes in both the EPs concentration and the organic loading rate (OLR) and maintained dominance with >85 % of total 16S gene copies. Indeed, an increment of the OLR caused an increase of the biomass growth and activity concomitantly with a higher EPs removal efficiency (30 ±â€¯13 vs 54 ±â€¯11 % removal for OLR of 307 ±â€¯4 and 590 ±â€¯8 mgCOD L-1 d-1, respectively). Biodegradation is the main mechanism of EPs removal due to low EPs accumulation on the biomass, the membrane or the reactor walls. Low EPs adsorption avoided biomass contamination, resulting in no effect on its biological methane potential. These results support the use of PPB technologies for resource recovery with low EPs contamination of the products.


Assuntos
Proteobactérias/efeitos dos fármacos , Águas Residuárias/química , Poluentes Químicos da Água/toxicidade , Compostos de Amônio/análise , Anaerobiose , Biomassa , Reatores Biológicos , Membranas Artificiais , Proteobactérias/fisiologia , Poluentes Químicos da Água/análise , Purificação da Água/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA