Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Oral Investig ; 21(1): 301-307, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26984823

RESUMO

OBJECTIVES: The aims of this study were to evaluate microbial contamination in phosphor storage plates in dental radiology services and discuss the possible origin of this contamination. MATERIALS AND METHODS: The sample comprised 50 phosphor plates: 14 plates from service A, 30 from service B, and 6 in the control group, consisting of plates never used. Damp sterile swabs were rubbed on the phosphor plates, and then transferred to tests tubes containing sterile saline solution. Serial dilutions were made, and then inoculated in triplicate on Mueller Hinton agar plates and incubated at 37 °C/48 h, before counting the colony-forming units (CFU). The samples were also seeded in brain-heart infusion medium to confirm contamination by turbidity of the culture medium. All solutions, turbid and clean, were seeded in selective and non-selective media. RESULTS: At service A and B, 50 and 73.3 % of the phosphor plates were contaminated, respectively. This contamination was mainly due to bacteria of the genus Staphylococcus. CFU counts ranged from 26.4 to 80.0 CFU/plate. CONCLUSIONS: Most of the phosphor plates evaluated shown to be contaminated, mainly by Staphylococcus ssp. Quantitatively, this contamination occurred at low levels, possibly arising from handling of the plates. The use of a second plastic barrier may have diminished contamination by microorganisms from the oral cavity. CLINICAL RELEVANCE: There is a risk of cross-contamination by phosphor storage plates used in dental radiology services.


Assuntos
Contaminação de Equipamentos , Controle de Infecções Dentárias , Radiografia Dentária Digital/instrumentação , Staphylococcus/isolamento & purificação , Contagem de Colônia Microbiana , Humanos
2.
BMC Complement Altern Med ; 15: 417, 2015 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-26601661

RESUMO

BACKGROUND: Limitations of antifungal agents used in the treatment of oral candidiasis, as the development of resistant strains, are known by the scientific community. In this context, the aim of this study was to evaluate the antifungal activity of thymol against Candida albicans, Candida tropicalis and Candida krusei strains and to determine its mode of action and synergistic effect when combined with the synthetic antifungal nystatin. METHODS: The minimum inhibitory concentration (MIC) was determined using a microdilution technique, and the minimum fungicidal concentration (MFC) was determined via subculture sowing. The mode of action of thymol was established by verifying fungal growth in the presence of sorbitol or ergosterol. The fractional inhibitory concentration index (FIC) was determined using the checkerboard method. RESULTS: Thymol presented an antifungal effect, with MICs of 39 µg/mL for C. albicans and C. krusei and 78 µg/mL for C. tropicalis. The results of the antifungal test remained unchanged in the presence of sorbitol; however, the MIC value of thymol against C. albicans increased eight times (from 39.0 to 312.5 µg/mL) in presence of exogenous ergosterol. The combination of thymol and nystatin reduced the MIC values of both products by 87.4%, generating an FIC index of 0.25. CONCLUSIONS: Thymol was found to have a fungicidal effect on Candida species and a synergistic effect when combined with nystatin.


Assuntos
Antifúngicos/farmacologia , Candida/efeitos dos fármacos , Candidíase Bucal/microbiologia , Nistatina/farmacologia , Timol/farmacologia , Candida/classificação , Candida/crescimento & desenvolvimento , Candidíase Bucal/tratamento farmacológico , Sinergismo Farmacológico , Humanos , Testes de Sensibilidade Microbiana , Boca/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA