Eur J Neurol ; 20(6): 968-74, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23530687

RESUMO

BACKGROUND AND PURPOSE: To describe the long-term follow-up of a cohort of 22 patients with the Miyoshi phenotype of distal muscular dystrophy (MMD). METHODS: A long-term clinical follow-up study was conducted. Patients were genotyped for dysferlin (MMD1) or anoctamin 5 (MMD3) mutations. Patients also underwent cardiological evaluation. RESULTS: There were 10 patients with MMD1, eight patients with MMD3 and four patients with linkage to chromosome 10 (MMD2). All patients deteriorated over 5.7 (range: 4.2-6.6) years of follow-up. Weakness increased significantly (P < 0.035) in all but the neck extensor, serratus anterior, and wrist flexor and extensor muscles. The decrease of strength was most pronounced in the iliopsoas (15%), toe extensors (15%), anterior tibial and peroneal muscles (10%). Patients with MMD1 showed early onset of the disease (mean 22 years) with typically symmetrical distribution of weakness starting in the calf muscles. Patients with MMD1 had a worse clinical course compared with patients with MMD3. Ninety percent of the former had to make use of a wheelchair within 15 years after onset of the disease, whereas patients with MMD3, who have a significantly later onset (mean 35 years) of asymmetrical calf muscle weakness and atrophy, remained ambulant during the first 15 years of their disease. None of the patients with MMD2 became fully confined to the wheelchair. None of the 22 MMD phenotype patients had heart disease. CONCLUSIONS: Patients with MMD1 have a worse clinical course compared with patients with MMD3. There are no cardiological abnormalities in all MMD categories.


Assuntos
Miopatias Distais/diagnóstico , Miopatias Distais/genética , Atrofia Muscular/diagnóstico , Atrofia Muscular/genética , Fenótipo , Adulto , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
2.
Neth Heart J ; 24(1): 73-4, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26643304
4.
Neth Heart J ; 16(Suppl 1): S20-4, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18958264

RESUMO

The diagnostic programmes of modern pacemakers have increased our knowledge of atrial tachyarrhythmias (ATAs) in chronically paced patients. These programmes also support the evaluation of the effects of pharmacological treatment of ATAs. The success of interruption and/or prevention of ATAs with pacemakers depends strongly on the diagnostic accuracy and the properties of the pacing algorithms, their individual programming and the site and configuration of the pacing leads. Atrial septum pacing can be beneficial in patients with paroxysmal atrial fibrillation and prolonged P wave duration. Recent large-scale studies on preventive and interruptive atrial pacing of ATAs show modestly positive or no results. Therefore, atrial pacing therapy for ATAs should be considered cautiously, serving as an adjuvant to pharmacological treatment rather than as a primary intervention. This also applies for pacing interventions for ATAs in cardiac resynchronisation therapy. The pacemaker algorithms for the detection of ATAs and atrial lead configuration are crucial for the success of pacemaker-mediated prevention or interruption of ATAs. The success of these interventions is dependant on future improvements of pacemaker technology. (Neth Heart J 2008;16(Suppl1):S20-S24.).

5.
Neth Heart J ; 16(6): 201-10, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18665205

RESUMO

BACKGROUND: Correct pacemaker (PM) diagnosis of paroxysmal atrial tachyarrhythmias is crucial for their prevention and intervention with specific atrial pacing programmes. The PM mode switch to only ventricular pacing after detection of atrial tachyarrhythmias is often used as the parameter to quantify the 'burden' of atrial tachyarrhythmias. OBJECTIVES: This review addresses potential errors in the detection and diagnosis of atrial tachyarrhythmias, sometimes resulting in incorrect mode switches. The interpretation of PM-stored data of patients with atrial tachyarrhythmias and the results of trials of pace prevention and intervention can be better appreciated with more insight into the technical options and pitfalls. RESULTS: Literature and clinical experience demonstrate that the correctness of PM-derived diagnosis of atrial tachyarrhythmias depends on 1) the sensitivity setting to detect the onset and perpetuation of atrial tachyarrhythmias frequently characterised by variable and low-voltage signals, 2) the rejection of far-field R wave sensing by the atrial sense amplifier, 3) the facility for verification of mode switches by a high-quality intracardiac registration of the nonmodified atrial electrogram. The configuration of the atrial lead also contributes to the diagnostic performance of the PM. CONCLUSION: Not only pacing algorithms and diverse technical PM features but also the atrial lead configuration are currently the limiting factors to the fully reliable, automated detection and diagnosis of atrial tachyarrhythmias. If these technical shortcomings can be improved, better signal processing will result. Then atrial pacing to prevent or suppress atrial tachyarrhythmias will be more justified. (Neth Heart J 2008;16:201-10.).

7.
Neth Heart J ; 14(1): 28-30, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25696553

RESUMO

An 84-year-old female patient presented to the coronary care unit with dizziness. A DDD-R minute ventilation sensor pacemaker had been implanted eight years previously. The ECG showed an atrial and ventricular paced rhythm of 140 beats/min. After disconnecting the patient from the cardiac monitor the pacemaker rate dropped gradually to 90 beats/min. The cardiac rhythm monitoring system applies low-amplitude electrical pulses in order to measure respiration rate by transthoracic impedance (TTI) measurement. The minute ventilation pacemaker sensor is driven by the same TTI measurement for rate response. Inappropriate interference between these two systems caused a sensor-driven high pacemaker rate. The dizziness was not related to the sensor-driven high rate.

8.
Neth Heart J ; 14(5): 183-186, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-25696624

RESUMO

Carbon monoxide poisoning is a major cause of morbidity and mortality worldwide. Immediate and proper treatment is crucial for prognosis and is merely dependent on accurate diagnosis. However, correct diagnosis can be difficult due to the aspecific symptomatology in CO poisoning. In this report a case is discussed in which a patient with accidental CO poisoning presented primarily with syncope, extensive ECG changes and elevated troponin levels. In addition, a limited review of the current literature is provided.

9.
Neth Heart J ; 14(7-8): 258-262, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25696650

RESUMO

Cardiac involvement in classical Steinert muscular dystrophy (dystrophia myotonica, MD1) is characterised by atrial arrhythmias, AV conduction disturbance, ventricular arrhythmias and heart failure. In MD1 patients complaints of fatigue and reduced exercise tolerance are well explained by the muscular weakness, but the same symptoms can be attributed to arrhythmia, atrioventricular block and heart failure. As cardiac pathology is often encountered in MD1 patients, an ECG, echocardiogram and Holter registrations should be performed on a routine basis. We report on two patients with MD1 who developed Mobitz II block as initial presentation of cardiac disease.

10.
Am J Cardiol ; 83(5B): 187D-191D, 1999 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-10089864

RESUMO

Pacing leads remain the "weaker link" of the permanent pacing system. Lead failure has been an issue since the beginning of implantable pacemaker therapy. Modern electronics have brought about considerable progress in pacing technology, but lead design has been slower to evolve and problems persist. IS-1 standardization must be considered a significant advance, but some issues regarding IS-1 standardization persist and have been the cause of some compatibility problems. With respect to lead insulation, silicone has proved to offer total reliability for > 30 years. In the search for better handling characteristics, polyurethane 80A was employed for bipolar leads, but it failed to demonstrate satisfactory insulating properties. New insulation materials, such as ethylene-fluoro-ethylene (ETFE), and coated wire technology look promising, having shown 99.32% survival at 5-year follow-up. Reliability is the main objective in lead design, but leads should provide low battery consumption as well. Low coil resistance, with high electrode impedance in steroid-eluting leads, is the standard at present. Low polarization is a desirable property for 2 main reasons: (1) in conjunction with low-threshold leads, it decreases battery consumption; and (2) it allows capture detection and, therefore, safer pacing at low battery consumption. Lead tip design as well as pacing pulse configuration can influence polarization.


Assuntos
Eletrodos Implantados , Marca-Passo Artificial , Eletrocardiografia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos
11.
Am J Cardiol ; 88(9): 949-55, 2001 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11703987

RESUMO

The prognostic value of myocardial viability early after acute myocardial infarction (AMI) is still controversial, depending on the patient under study and the outcome end point considered. Furthermore, the relative prognostic importance of viability compared with indicators of systolic left ventricular (LV) dysfunction is not known. One hundred thirty-eight patients were studied with low-dose dobutamine echocardiography 3 +/- 1 days after AMI. Patients were divided in 2 groups based on presence (n = 55) or absence (n = 83) of myocardial viability and followed up for in-hospital and late cardiac events. During hospitalization, myocardial viability was the only independent predictor for recurrent ischemic events (chi-square 5.0, p = 0.025). End-systolic volume index and ejection fraction were both independent predictors of the occurrence of heart failure, whereas gender and end-systolic volume index emerged as independent predictors of hard cardiac events (death and sustained ventricular tachycardia). After hospital discharge, patients were followed for 19 +/- 7 months. Again, myocardial viability emerged as the only independent predictor of unstable angina (chi-square 7.7, p = 0.005). Age, hypertension, and ejection fraction were the most important independent predictors of hospitalization for heart failure, whereas ejection fraction was the only independent predictor of hard cardiac events. Presence of myocardial viability early after AMI is the single best predictor of recurrent in-hospital ischemic events and unstable angina after discharge. With respect to hard cardiac events and occurrence of heart failure, indicators of LV systolic dysfunction have a higher prognostic value than presence of myocardial viability.


Assuntos
Ecocardiografia sob Estresse , Infarto do Miocárdio/mortalidade , Miocárdio/patologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Agonistas Adrenérgicos beta , Idoso , Dobutamina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Volume Sistólico , Sístole
12.
J Neurol ; 244(10): 657-63, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9402544

RESUMO

We evaluated the course of cardiac involvement in 27 previously reported patients with Becker muscular dystrophy (BMD) originating from nine kindreds. Since almost all affected individuals of each kindred were included, intrafamilial variability could be studied. We also attempted to identify associations between cardiac involvement, functional ability and mutations at DNA level. The mean follow-up period was 12.5 years. The number of patients with electrocardiographic abnormalities progressed from 44% to 71%. Dilated cardiomyopathy (DCM) with or without congestive heart failure was now present in 33% as compared with 15% in the previous study. In addition, 22% developed borderline echocardiographic abnormalities. Six patients (22%) became symptomatic and four patients died of congestive heart failure. In all families cardiac abnormalities were found. There was no association between DCM and mutation type. Despite equal functional motor ability, there was a considerable intrafamilial variation in cardiac involvement, even in brother pairs. We conclude that cardiac abnormalities are the rule and not the exception in BMD and are progressive over time. Left ventricular dilatation may begin at any moment in the course of BMD and the rate of progression is unpredictable. A substantial proportion of patients will develop an incapacitating and life-threatening DCM.


Assuntos
Doenças Cardiovasculares/etiologia , Distrofias Musculares/complicações , Adolescente , Adulto , Doenças Cardiovasculares/genética , Ecocardiografia , Eletrocardiografia , Seguimentos , Humanos , Pessoa de Meia-Idade , Distrofias Musculares/genética , Mutação
13.
Heart ; 79(1): 73-7, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9505924

RESUMO

OBJECTIVE: To assess the frequency, nature, and severity of cardiac abnormalities in limb girdle muscular dystrophy, and its relation to age and weakness in various genotypes. DESIGN: In 26 autosomal dominant, 38 autosomal recessive, and 33 sporadic strictly defined patients with limb girdle muscular dystrophy, cardiac evaluation included history, physical examination, chest x ray, electrocardiography, 24 hour ECG Holter monitoring, and echocardiography. In 35 of the 71 autosomal recessive and sporadic cases muscle biopsies were available for sarcoglycan analysis. MAIN RESULTS: Dilated cardiomyopathy was present in one autosomal dominant case and in three advanced autosomal recessive or sporadic patients, of whom two were found to have alpha sarcoglycan deficiency. Two of these three patients and three other cases showed ECG abnormalities known to be characteristic of the dystrophinopathies. A strong association between the absence of alpha sarcoglycan and the presence of dilated cardiomyopathy was found (p = 0.04). In six autosomal dominant cases there were atrioventricular (AV) conduction disturbances, increasing in severity with age and in concomitant presence of muscle weakness. Pacemaker implantation was necessary in four. CONCLUSIONS: 10% of these patients had clinically relevant cardiac abnormalities. In autosomal dominant limb girdle muscular dystrophy one subtype characterised by muscle weakness and AV conduction disturbances is recognised. In the course of autosomal recessive/sporadic limb girdle muscular dystrophy, dilated cardiomyopathy may develop, probably related to deficiency of dystrophin associated proteins.


Assuntos
Cardiomiopatia Dilatada/etiologia , Distrofias Musculares/complicações , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Proteínas do Citoesqueleto/deficiência , Proteínas do Citoesqueleto/genética , Distrofina/genética , Ecocardiografia , Eletrocardiografia Ambulatorial , Feminino , Genes Dominantes , Genes Recessivos , Genótipo , Humanos , Masculino , Glicoproteínas de Membrana/deficiência , Glicoproteínas de Membrana/genética , Pessoa de Meia-Idade , Músculo Esquelético/fisiopatologia , Distrofias Musculares/genética , Sarcoglicanas
14.
Ned Tijdschr Geneeskd ; 144(46): 2181-4, 2000 Nov 11.
Artigo em Holandês | MEDLINE | ID: mdl-11103252

RESUMO

Duchenne and Becker muscular dystrophy are caused by a mutation in the dystrophin gene, located on the short arm of the X chromosome. Three so called dystrophinopathy patients, a women aged 54 and two men aged 23 and 21 years, suffered from a severe dilated cardiomyopathy. Such a cardiomyopathy can develop in both carriers and patients. In addition, it is often more important for prognosis than muscle weakness. For these two reasons it is important to screen both groups for (early) cardiological abnormalities. If these are present, regular follow-up is necessary to start timely therapy. When cardiological investigations yield normal results, it is advised to screen carriers with a five-year interval. Dystrophinopathy patients should be checked every year, because the cardiomyopathy sometimes develops and deteriorates over a short period of time. Patients with dilated cardiomyopathy and with a positive family history for dilated cardiomyopathy, muscle weakness or high serum creatine kinase activity should be screened for a mutation in the dystrophin gene.


Assuntos
Cardiomiopatia Dilatada/genética , Distrofina/genética , Distrofia Muscular de Duchenne/diagnóstico , Distrofia Muscular de Duchenne/genética , Mutação , Adulto , Creatina Quinase/sangue , Diagnóstico Diferencial , Evolução Fatal , Feminino , Ligação Genética , Testes Genéticos , Humanos , Masculino , Pessoa de Meia-Idade , Debilidade Muscular/genética , Distrofia Muscular de Duchenne/sangue , Distrofia Muscular de Duchenne/complicações , Mioglobinúria/genética , Fenótipo , Cromossomo X/genética
15.
Neth Heart J ; 12(1): 18-22, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25696255

RESUMO

Today, new pacing algorithms and stimulation methods for the prevention and interruption of atrial tachyarrhythmias can be applied on patients who need bradycardia pacing for conventional reasons. In addition, biventricular pacing as additive treatment for patients with severe congestive heart failure due to ventricular systolic dysfunction and prolonged intraventricular conduction has shown to improve symptoms and reduce hospital admissions. These new pacing technologies and the optimising of the pacing programmes are complex, expensive and time-consuming. Based on many clinical studies the indications for these devices are beginning to emerge. To support the cardiologist's decision-making and to prevent waste of effort and resources, the 'ad hoc committee' has provided preliminary recommendations for implantable devices to treat atrial tachyarrhythmias and to extend the treatment of congestive heart failure respectively.

16.
Neth Heart J ; 19(1): 50-1, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22020859

RESUMO

Pacemaker syndrome represents the clinical consequences of the haemodynamic adverse effects of atrioventricular asynchrony during pacing. Patients suffering from hypertrophic cardiomyopathy may be particularly sensitive to these effects because of the importance of atrial systolic contribution to left ventricular diastolic filling. In this case report, we describe the symptoms and cause of pacemaker syndrome in a patient with hypertrophic obstructive cardiomyopathy.