Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Nature ; 572(7770): 507-510, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31435058

RESUMO

The ability to manipulate droplets on a substrate using electric signals1-known as digital microfluidics-is used in optical2,3, biomedical4,5, thermal6 and electronic7 applications and has led to commercially available liquid lenses8 and diagnostics kits9,10. Such electrical actuation is mainly achieved by electrowetting, with droplets attracted towards and spreading on a conductive substrate in response to an applied voltage. To ensure strong and practical actuation, the substrate is covered with a dielectric layer and a hydrophobic topcoat for electrowetting-on-dielectric (EWOD)11-13; this increases the actuation voltage (to about 100 volts) and can compromise reliability owing to dielectric breakdown14, electric charging15 and biofouling16. Here we demonstrate droplet manipulation that uses electrical signals to induce the liquid to dewet, rather than wet, a hydrophilic conductive substrate without the need for added layers. In this electrodewetting mechanism, which is phenomenologically opposite to electrowetting, the liquid-substrate interaction is not controlled directly by electric field but instead by field-induced attachment and detachment of ionic surfactants to the substrate. We show that this actuation mechanism can perform all the basic fluidic operations of digital microfluidics using water on doped silicon wafers in air, with only ±2.5 volts of driving voltage, a few microamperes of current and about 0.015 times the critical micelle concentration of an ionic surfactant. The system can also handle common buffers and organic solvents, promising a simple and reliable microfluidic platform for a broad range of applications.


Assuntos
Eletroumectação/métodos , Microfluídica/métodos , Tensoativos/química , Acetonitrilas/química , Soluções Tampão , Dimetil Sulfóxido/química , Etilenoglicol/química , Interações Hidrofóbicas e Hidrofílicas , Íons/química , Microfluídica/instrumentação , Silício/química
2.
Chem Eng J ; 4682023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37576334

RESUMO

The growing discovery and development of novel radiopharmaceuticals and radiolabeling methods requires an increasing capacity for radiochemistry experiments. However, such studies typically rely on radiosynthesizers designed for clinical batch production rather than research, greatly limiting throughput. Two general solutions are being pursued to address this: developing new synthesis optimization algorithms to minimize how many experiments are needed, and developing apparatus with enhanced experiment throughput. We describe here a novel high-throughput system based on performing arrays of droplet-based reactions at 10 µL volume scale in parallel. The automatic robotic platform can perform a set of 64 experiments in ~3 h (from isotope loading to crude product, plus sampling onto TLC plates), plus ~1 h for off-line radio-TLC analysis and radioactivity measurements, rather than the weeks or months that would be needed using a conventional system. We show the high repeatability and low crosstalk of the platform and demonstrate optimization studies for two 18F-labeled tracers. This novel automated platform greatly increases the practicality of performing arrays of droplet reactions by eliminating human error, vastly reducing tedium and fatigue, minimizing radiation exposure, and freeing up radiochemist time for other intellectually valuable pursuits.

3.
Molecules ; 27(23)2022 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-36500272

RESUMO

Before formulating radiopharmaceuticals for injection, it is necessary to remove various impurities via purification. Conventional synthesis methods involve relatively large quantities of reagents, requiring high-resolution and high-capacity chromatographic methods (e.g., semi-preparative radio-HPLC) to ensure adequate purity of the radiopharmaceutical. Due to the use of organic solvents during purification, additional processing is needed to reformulate the radiopharmaceutical into an injectable buffer. Recent developments in microscale radiosynthesis have made it possible to synthesize radiopharmaceuticals with vastly reduced reagent masses, minimizing impurities. This enables purification with lower-capacity methods, such as analytical HPLC, with a reduction of purification time and volume (that shortens downstream re-formulation). Still, the need for a bulky and expensive HPLC system undermines many of the advantages of microfluidics. This study demonstrates the feasibility of using radio-TLC for the purification of radiopharmaceuticals. This technique combines high-performance (high-resolution, high-speed separation) with the advantages of a compact and low-cost setup. A further advantage is that no downstream re-formulation step is needed. Production and purification of clinical scale batches of [18F]PBR-06 and [18F]Fallypride are demonstrated with high yield, purity, and specific activity. Automating this radio-TLC method could provide an attractive solution for the purification step in microscale radiochemistry systems.


Assuntos
Microfluídica , Compostos Radiofarmacêuticos , Compostos Radiofarmacêuticos/química , Cromatografia em Camada Fina , Radioquímica/métodos , Cromatografia Líquida de Alta Pressão/métodos
4.
Mol Imaging ; 19: 1536012120973099, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33296272

RESUMO

New platforms are enabling radiochemistry to be carried out in tiny, microliter-scale volumes, and this capability has enormous benefits for the production of radiopharmaceuticals. These droplet-based technologies can achieve comparable or better yields compared to conventional methods, but with vastly reduced reagent consumption, shorter synthesis time, higher molar activity (even for low activity batches), faster purification, and ultra-compact system size. We review here the state of the art of this emerging direction, summarize the radiotracers and prosthetic groups that have been synthesized in droplet format, describe recent achievements in scaling up activity levels, and discuss advantages and limitations and the future outlook of these innovative devices.


Assuntos
Compostos Radiofarmacêuticos , Radioquímica
5.
Anal Chem ; 92(4): 3483-3491, 2020 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-31986878

RESUMO

For decades, there has been immense progress in miniaturizing analytical methods based on electrophoresis to improve sensitivity and to reduce sample volumes, separation times, and/or equipment cost and space requirements, in applications ranging from analysis of biological samples to environmental analysis to forensics. In the field of radiochemistry, where radiation-shielded laboratory space is limited, there has been great interest in harnessing the compactness, high efficiency, and speed of microfluidics to synthesize short-lived radiolabeled compounds. We recently proposed that analysis of these compounds could also benefit from miniaturization and have been investigating capillary electrophoresis (CE) and hybrid microchip electrophoresis (hybrid-MCE) as alternatives to the typically used high-performance liquid chromatography (HPLC). We previously showed separation of the positron-emission tomography (PET) imaging tracer 3'-deoxy-3'-fluorothymidine (FLT) from its impurities in a hybrid-MCE device with UV detection, with similar separation performance to HPLC, but with improved speed and lower sample volumes. In this paper, we have developed an integrated radiation detector to enable measurement of the emitted radiation from radiolabeled compounds. Though conventional radiation detectors have been incorporated into CE systems in the past, these approaches cannot be readily integrated into a compact hybrid-MCE device. We instead employed a solid-state avalanche photodiode (APD)-based detector for real-time, high-sensitivity ß particle detection. The integrated system can reliably separate [18F]FLT from its impurities and perform chemical identification via coinjection with nonradioactive reference standard. This system can quantitate samples with radioactivity concentrations as low as 114 MBq/mL (3.1 mCi/mL), which is sufficient for analysis of radiochemical purity of radiopharmaceuticals.


Assuntos
Didesoxinucleosídeos/análise , Eletroforese em Microchip , Cromatografia Líquida , Eletroforese em Microchip/instrumentação , Radioisótopos de Flúor
6.
Eur J Nucl Med Mol Imaging ; 47(8): 2026-2035, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31729540

RESUMO

PURPOSE: Multidrug resistance (MDR) impedes cancer treatment. Two efflux transporters from the ATP-binding cassette (ABC) family, ABCB1 and ABCG2, may contribute to MDR by restricting the entry of therapeutic drugs into tumor cells. Although a higher expression of these transporters has been correlated with an unfavorable response to chemotherapy, transporter expression does not necessarily correlate with function. In this study, we characterized the pharmacological properties of [18F]AVT-011, a new PET radiotracer for imaging transporter-mediated MDR in tumors. METHODS: AVT-011 was radiolabeled with 18F and evaluated with PET imaging in preclinical models. Transport of [18F]AVT-011 by ABCB1 and/or ABCG2 was assessed by measuring its uptake in the brains of wild-type, Abcb1a/b-/-, and Abcg2-/- mice at baseline and after administration of the ABCB1 inhibitor tariquidar (n = 5/group). Metabolism and biodistribution of [18F]AVT-011 were also measured. To measure ABCB1 function in tumors, we performed PET experiments using both [18F]AVT-011 and [18F]FDG in mice bearing orthotopic breast tumors (n = 7-10/group) expressing clinically relevant levels of ABCB1. RESULTS: At baseline, brain uptake was highest in Abcb1a/b-/- mice. After tariquidar administration, brain uptake increased 3-fold and 8-fold in wild-type and Abcg2-/- mice, respectively, but did not increase further in Abcb1a/b-/- mice. At 30 min after injection, the radiotracer was > 90% in its parent form and had highest uptake in organs of the hepatobiliary system. Compared with that in drug-sensitive tumors, uptake of [18F]AVT-011 was 32% lower in doxorubicin-resistant tumors with highest ABCB1 expression and increased by 40% with tariquidar administration. Tumor uptake of [18F]FDG did not significantly differ among groups. CONCLUSION: [18F]AVT-011 is a dual ABCB1/ABCG2 substrate radiotracer that can quantify transporter function at the blood-brain barrier and in ABCB1-expressing tumors, making it potentially suitable for clinical imaging of ABCB1-mediated MDR in tumors.


Assuntos
Resistência a Múltiplos Medicamentos , Tomografia por Emissão de Pósitrons , Membro 2 da Subfamília G de Transportadores de Cassetes de Ligação de ATP/genética , Membro 2 da Subfamília G de Transportadores de Cassetes de Ligação de ATP/metabolismo , Animais , Barreira Hematoencefálica/metabolismo , Camundongos , Distribuição Tecidual
7.
Proc Natl Acad Sci U S A ; 114(43): 11309-11314, 2017 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-29073049

RESUMO

New radiolabeled probes for positron-emission tomography (PET) are providing an ever-increasing ability to answer diverse research and clinical questions and to facilitate the discovery, development, and clinical use of drugs in patient care. Despite the high equipment and facility costs to produce PET probes, many radiopharmacies and radiochemistry laboratories use a dedicated radiosynthesizer to produce each probe, even if the equipment is idle much of the time, to avoid the challenges of reconfiguring the system fluidics to switch from one probe to another. To meet growing demand, more cost-efficient approaches are being developed, such as radiosynthesizers based on disposable "cassettes," that do not require reconfiguration to switch among probes. However, most cassette-based systems make sacrifices in synthesis complexity or tolerated reaction conditions, and some do not support custom programming, thereby limiting their generality. In contrast, the design of the ELIXYS FLEX/CHEM cassette-based synthesizer supports higher temperatures and pressures than other systems while also facilitating flexible synthesis development. In this paper, the syntheses of 24 known PET probes are adapted to this system to explore the possibility of using a single radiosynthesizer and hot cell for production of a diverse array of compounds with wide-ranging synthesis requirements, alongside synthesis development efforts. Most probes were produced with yields and synthesis times comparable to literature reports, and because hardware modification was unnecessary, it was convenient to frequently switch among probes based on demand. Although our facility supplies probes for preclinical imaging, the same workflow would be applicable in a clinical setting.


Assuntos
Radioisótopos de Flúor/química , Radioquímica/métodos , Compostos Radiofarmacêuticos/síntese química , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/química
8.
Eur J Nucl Med Mol Imaging ; 46(2): 489-500, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30456475

RESUMO

PURPOSE: Metabolic imaging using [18F]FDG is the current standard for clinical PET; however, some malignancies (e.g., indolent lymphomas) show low avidity for FDG. The majority of B cell lymphomas express CD20, making it a valuable target both for antibody-based therapy and imaging. We previously developed PET tracers based on the humanised anti-CD20 antibody obinutuzumab (GA101). Preclinical studies showed that the smallest bivalent fragment, the cys-diabody (GAcDb, 54.5 kDa) with a peak uptake at 1-2 h post-injection and a biological half-life of 2-5 h, is compatible with short-lived positron emitters such as fluorine-18 (18F, t1/2 110 min), enabling same-day imaging. METHODS: GAcDb was radiolabeled using amine-reactive N-succinimidyl 4-[18F]-fluorobenzoate ([18F]SFB), or thiol-reactive N-[2-(4-[18F]-fluorobenzamido)ethyl]maleimide ([18F]FBEM) for site-specific conjugation to C-terminal cysteine residues. Both tracers were used for immunoPET imaging of the B cell compartment in human CD20 transgenic mice (hCD20TM). [18F]FB-GAcDb immunoPET was further evaluated in a disseminated lymphoma (A20-hCD20) syngeneic for hCD20TM and compared to [18F]FDG PET. Tracer uptake was confirmed by ex vivo biodistribution. RESULTS: The GAcDb was successfully 18F-radiolabeled using two different conjugation methods resulting in similar specific activities and without impairing immunoreactivity. Both tracers ([18F]FB-GAcDb and [18F]FBEM-GAcDb) specifically target human CD20-expressing B cells in transgenic mice. Fast blood clearance results in high contrast PET images as early as 1 h post injection enabling same-day imaging. [18F]FB-GAcDb immunoPET detects disseminated lymphoma disease in the context of normal tissue expression of hCD20, with comparable sensitivity as [18F]FDG PET but with added specificity for the therapeutic target. CONCLUSIONS: [18F]FB-GAcDb and [18F]FBEM-GAcDb could monitor normal B cells and B cell malignancies non-invasively and quantitatively in vivo. In contrast to [18F]FDG PET, immunoPET provides not only information about the extent of disease but also about presence and localisation of the therapeutic target.


Assuntos
Anticorpos/imunologia , Antígenos CD20/imunologia , Radioisótopos de Flúor , Linfoma de Células B/diagnóstico por imagem , Linfoma de Células B/patologia , Tomografia por Emissão de Pósitrons/métodos , Animais , Humanos , Marcação por Isótopo , Linfoma de Células B/imunologia , Camundongos , Camundongos Transgênicos , Radioquímica , Fatores de Tempo , Distribuição Tecidual
9.
Anal Bioanal Chem ; 410(9): 2423-2436, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29470664

RESUMO

Miniaturized synthesis of positron emission tomography (PET) tracers is poised to offer numerous advantages including reduced tracer production costs and increased availability of diverse tracers. While many steps of the tracer production process have been miniaturized, there has been relatively little development of microscale systems for the quality control (QC) testing process that is required by regulatory agencies to ensure purity, identity, and biological safety of the radiotracer before use in human subjects. Every batch must be tested, and in contrast with ordinary pharmaceuticals, the whole set of tests of radiopharmaceuticals must be completed within a short-period of time to minimize losses due to radioactive decay. By replacing conventional techniques with microscale analytical ones, it may be possible to significantly reduce instrument cost, conserve lab space, shorten analysis times, and streamline this aspect of PET tracer production. We focus in this work on miniaturizing the subset of QC tests for chemical identity and purity. These tests generally require high-resolution chromatographic separation prior to detection to enable the approach to be applied to many different tracers (and their impurities), and have not yet, to the best of our knowledge, been tackled in microfluidic systems. Toward this end, we previously explored the feasibility of using the technique of capillary electrophoresis (CE) as a replacement for the "gold standard" approach of using high-performance liquid chromatography (HPLC) since CE offers similar separating power, flexibility, and sensitivity, but can readily be implemented in a microchip format. Using a conventional CE system, we previously demonstrated the successful separation of non-radioactive version of a clinical PET tracer, 3'-deoxy-3'-fluorothymidine (FLT), from its known by-products, and the separation of the PET tracer 1-(2'-deoxy-2'-fluoro-ß-D-arabinofuranosyl)-cytosine (D-FAC) from its α-isomer, with sensitivity nearly as good as HPLC. Building on this feasibility study, in this paper, we describe the first effort to miniaturize the chemical identity and purity tests by using microchip electrophoresis (MCE). The fully automated proof-of-concept system comprises a chip for sample injection, a separation capillary, and an optical detection chip. Using the same model compound (FLT and its known by-products), we demonstrate that samples can be injected, separated, and detected, and show the potential to match the performance of HPLC. Addition of a radiation detector in the future would enable analysis of radiochemical identity and purity in the same device. We envision that eventually this MCE method could be combined with other miniaturized QC tests into a compact integrated system for automated routine QC testing of radiopharmaceuticals in the future. Graphical abstract Miniaturized quality control (QC) testing of batches of radiopharmaceuticals via microfluidic analysis. The proof-of-concept hybrid microchip electrophoresis (MCE) device demonstrated the feasibility of achieving comparable performance to conventional analytical instruments (HPLC or CE) for chemical purity testing.


Assuntos
Eletroforese em Microchip/instrumentação , Compostos Radiofarmacêuticos/análise , Cromatografia Líquida de Alta Pressão , Eletroforese em Microchip/métodos , Desenho de Equipamento , Controle de Qualidade
10.
J Am Chem Soc ; 137(17): 5686-94, 2015 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-25860121

RESUMO

Nucleophilic radiofluorination is an efficient synthetic route to many positron-emission tomography (PET) probes, but removal of water to activate the cyclotron-produced [(18)F]fluoride has to be performed prior to reaction, which significantly increases overall radiolabeling time and causes radioactivity loss. In this report, we demonstrate the possibility of (18)F-radiofluorination in highly aqueous medium. The method utilizes titania nanoparticles, 1:1 (v/v) acetonitrile-thexyl alcohol solvent mixture, and tetra-n-butylammonium bicarbonate as a phase-transfer agent. Efficient radiolabeling is directly performed with aqueous [(18)F]fluoride without the need for a drying/azeotroping step to significantly reduce radiosynthesis time. High radiochemical purity of the target compound is also achieved. The substrate scope of the synthetic strategy is demonstrated with a range of aromatic, aliphatic, and cycloaliphatic tosylated precursors.


Assuntos
Radioisótopos de Flúor/química , Titânio/química , Compostos de Tosil/síntese química , Acetonitrilas/química , Álcoois/química , Catálise , Estrutura Molecular , Nanopartículas/química , Compostos de Tosil/química , Água/química
11.
Mol Imaging ; 14(12): 13-14, 2015 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-26650206

RESUMO

The emerging technology of digital microfluidics is opening up the possibility of performing radiochemistry at the microliter scale to produce tracers for positron emission tomography (PET) labeled with fluorine-18 or other isotopes. Working at this volume scale not only reduces reagent costs but also improves specific activity (SA) by reducing contamination by the stable isotope. This technology could provide a practical means to routinely prepare high-SA tracers for applications such as neuroimaging and could make it possible to routinely achieve high SA using synthesis strategies such as isotopic exchange. Reagent droplets are controlled electronically, providing high reliability, a compact control system, and flexibility for diverse syntheses with a single-chip design. The compact size may enable the development of a self-shielded synthesizer that does not require a hot cell. This article reviews the progress of this technology and its application to the synthesis of PET tracers.

12.
J Micromech Microeng ; 25(8)2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29167603

RESUMO

Microscopic droplets or slugs of mixed reagents provide a convenient platform for performing large numbers of isolated biochemical or chemical reactions for many screening and optimization applications. Myriad microfluidic approaches have emerged for creating droplets or slugs with controllable size and composition, generally using an immiscible carrier fluid to assist with the formation or merging processes. We report a novel device for generation of liquid slugs in air when the use of a carrier liquid is not compatible with the application. The slug generator contains two adjacent chambers, each of which has a volume that can be digitally adjusted by closing selected microvalves. Reagents are filled into the two chambers, merged together into a contiguous liquid slug, ejected at the desired time from the device using gas pressure, and mixed by flowing in a downstream channel. Programmable size and composition of slugs is achieved by dynamically adjusting the volume of each chamber prior to filling. Slug formation in this fashion is independent of fluid properties and can easily be scaled to mix larger numbers of reagents. This device has already been used to screen monomer ratios in supramolecular nanoparticle assembly and radiolabeling conditions of engineered antibodies, and here we provide a detailed description of the underlying device.

13.
Proc Natl Acad Sci U S A ; 109(3): 690-5, 2012 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-22210110

RESUMO

We have developed an all-electronic digital microfluidic device for microscale chemical synthesis in organic solvents, operated by electrowetting-on-dielectric (EWOD). As an example of the principles, we demonstrate the multistep synthesis of [(18)F]FDG, the most common radiotracer for positron emission tomography (PET), with high and reliable radio-fluorination efficiency of [(18)F]FTAG (88 ± 7%, n = 11) and quantitative hydrolysis to [(18)F]FDG (> 95%, n = 11). We furthermore show that batches of purified [(18)F]FDG can successfully be used for PET imaging in mice and that they pass typical quality control requirements for human use (including radiochemical purity, residual solvents, Kryptofix, chemical purity, and pH). We report statistical repeatability of the radiosynthesis rather than best-case results, demonstrating the robustness of the EWOD microfluidic platform. Exhibiting high compatibility with organic solvents and the ability to carry out sophisticated actuation and sensing of reaction droplets, EWOD is a unique platform for performing diverse microscale chemical syntheses in small volumes, including multistep processes with intermediate solvent-exchange steps.


Assuntos
Eletrônica/instrumentação , Microquímica/instrumentação , Microquímica/métodos , Técnicas Analíticas Microfluídicas , Sondas Moleculares/síntese química , Animais , Cromatografia em Camada Fina , Eletroumectação , Radioisótopos de Flúor , Fluordesoxiglucose F18/síntese química , Halogenação , Humanos , Linfoma/diagnóstico por imagem , Camundongos , Camundongos SCID , Tomografia por Emissão de Pósitrons , Controle de Qualidade , Distribuição Tecidual , Tomografia Computadorizada por Raios X , Ensaios Antitumorais Modelo de Xenoenxerto
14.
Lab Chip ; 24(4): 728-737, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38240629

RESUMO

The [18F]fluorobenzyltriphenylphosphonium cation ([18F]FBnTP) has emerged as a highly promising positron emission tomography (PET) tracer for myocardial perfusion imaging (MPI) due to its uniform distribution in the myocardium and favorable organ biodistribution demonstrated in preclinical studies. However, a complex and low-efficiency radiosynthesis procedure has significantly hindered its broader preclinical and clinical explorations. Recently, Zhang et al. developed a pinacolyl arylboronate precursor, enabling a one-step synthesis process that greatly streamlines the production of [18F]FBnTP. Building upon this progress, our group successfully adapted the approach to a microdroplet reaction format and demonstrated improved radiosynthesis performance in a preliminary optimization study. However, scaling up to clinical dose amounts was not explored. In this work, we demonstrate that scale-up can be performed in a straightforward manner using a "numbering up" strategy (i.e. performing multiple droplet reactions in parallel and pooling the crude products). The resulting radiochemical yield after purification and formulation was high, up to 66 ± 1% (n = 4) for a set of experiments involving pooling of 4 droplet reactions, accompanied by excellent radiochemical purity (>99%) and molar activity (339-710 GBq µmol-1). Notably, we efficiently achieved sufficient activity yield (0.76-1.84 GBq) for multiple clinical doses from 1.6 to 3.7 GBq of [18F]fluoride in just 37-47 min.


Assuntos
Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Distribuição Tecidual , Tomografia por Emissão de Pósitrons/métodos , Radioquímica , Radioisótopos de Flúor
15.
Analyst ; 138(19): 5654-64, 2013 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-23928799

RESUMO

Microfluidic technologies provide an attractive platform for the synthesis of radiolabeled compounds. Visualization of radioisotopes on chip is critical for synthesis optimization and technological development. With Cerenkov imaging, beta particle emitting isotopes can be localized with a sensitive CCD camera. In order for Cerenkov imaging to also serve as a quantitative tool, it is necessary to understand how material properties relevant to Cerenkov emission, namely, index of refraction and beta particle stopping power, affect Cerenkov light output. In this report, we investigate the fundamental physical characteristics of Cerenkov photon yield at different stages of [(18)F]FDG synthesis on the electrowetting on dielectric (EWOD) microfluidic platform. We also demonstrate how Cerenkov imaging has enabled synthesis optimization. Geant4, a Monte Carlo program applied extensively in high energy physics, is used to simulate Cerenkov photon yield from (18)F beta particles traversing materials of interest during [(18)F]FDG synthesis on chip. Our simulations show that the majority (approximately two-thirds) of the (18)F beta particle energy available to produce Cerenkov photons is deposited on the glass plates of the EWOD chip. This result suggests the possibility of using a single calibration factor to convert Cerenkov signal to radioactivity, independent of droplet composition. We validate our simulations with a controlled measurement examining varying ratios of [(18)O]H2O, dimethyl sulfoxide (DMSO), and acetonitrile (MeCN), and find a consistent calibration independent of solvent composition. However, the calibration factor may underestimate the radioactivity in actual synthesis due to discoloration of the droplet during certain steps of probe synthesis. In addition to the attractive quantitative potential of Cerenkov imaging, this imaging strategy provides indispensable qualitative data to guide synthesis optimization. We are able to use this imaging technique to optimize the mixing protocol as well as identify and correct for loss of radioactivity due to the migration of radioactive vapor outside of the EWOD heater, enabling an overall increase in the crude radiochemical yield from 50 ± 3% (n = 3) to 72 ± 13% (n = 5).


Assuntos
Fluordesoxiglucose F18/análise , Microfluídica/métodos , Imagem Óptica/métodos , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18/síntese química
16.
Anal Methods ; 15(3): 377-387, 2023 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-36542448

RESUMO

The list of new positron-emission tomography (PET) tracers has rapidly grown in the past decade, following discoveries of new biological targets and therapeutic strategies, with several compounds garnering recent regulatory approval for clinical use. During the development of synthesis methods and production of new tracers for imaging, analytical methods for radio-high performance liquid chromatography (radio-HPLC) and radio-thin layer chromatography (radio-TLC) separations need to be developed to assess radiochemical compositions. Radio-TLC is often faster, simpler, and sometimes more accurate than radio-HPLC (as there is no underestimation of [18F]fluoride when analyzing 18F-labeled radiopharmaceuticals). Many protocols have been developed for separating 18F-radiopharmaceuticals on silica TLC plates, typically with [18F]fluoride retained at the origin and the radiopharmaceutical (and impurities) migrating along the plate. Interestingly, many reports describe the use of aqueous conditions to mobilize polar species, but it is known that aqueous conditions can modify silica and alter its chromatographic behavior. In this technical note, we explore the effects that aqueous conditions have on the analysis of 18F-radiopharmaceutical mixtures, revealing that with sufficient water, the radionuclide ([18F]fluoride) can migrate away from the origin and can be split into multiple bands. Furthermore, water can hinder the migration of the radiopharmaceutical. These effects can lead to overlapped bands or reversal of the normally expected order of bands, potentially leading to the misinterpretation of results if care is not taken to validate the TLC method carefully.


Assuntos
Fluoretos , Compostos Radiofarmacêuticos , Compostos Radiofarmacêuticos/efeitos adversos , Compostos Radiofarmacêuticos/química , Cromatografia em Camada Fina , Água , Dióxido de Silício
17.
Lab Chip ; 23(21): 4652-4663, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37818614

RESUMO

Copper-mediated radiofluorination has demonstrated remarkable potential in forming aromatic C-18F bonds of radioligands for positron emission tomography (PET). Achieving optimal results often requires optimization efforts, requiring a substantial amount of radiolabeling precursor and time, severely limiting the experimental throughput. Recently, we successfully showcased the feasibility of performing and optimizing Cu-mediated radiosynthesis on a high-throughput microdroplet platform using the well-known and clinically used radioligand [18F]FDOPA as an illustrative example. In our current work, we optimized the Cu-mediated synthesis of a novel monoacylglycerol lipase (MAGL) PET tracer ([18F]YH149), showing the versatility of droplet-based techniques for early stage tracer development. Across 5 days, we conducted a total of 117 experiments, studying 36 distinct conditions, while utilizing <15 mg of total organoboron precursor. Compared to the original report in which the radiochemical yield (RCY) was 4.4 ± 0.5% (n = 5), the optimized droplet condition provided a substantial improvement in RCY (52 ± 8%, n = 4) and showed excellent radiochemical purity (100%) and molar activity (77-854 GBq µmol-1), using a starting activity of 0.2-1.45 GBq. Furthermore, we showed for the first time a translation of the optimized microscale conditions to a vial-based method. With similar starting activity (0.2-1.44 GBq), the translated synthesis exhibited a comparable RCY of 50 ± 10% (n = 4) while maintaining excellent radiochemical purity (100%) and acceptable molar activity (20-46 GBq µmol-1). The successful translation to vial-based reactions ensures wider applicability of the optimized synthesis by leveraging widely available commercial vial-based synthesis modules.


Assuntos
Cobre , Monoacilglicerol Lipases , Radioisótopos de Flúor/química , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/química
18.
J Chromatogr A ; 1687: 463656, 2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36463649

RESUMO

Radiopharmaceutical analysis is limited by conventional methods. Radio-HPLC may be inaccurate for some compounds (e.g., 18F-radiopharmaceuticals) due to radionuclide sequester. Radio-TLC is simpler, faster, and detects all species but has limited resolution. Imaging-based readout of TLC plates (e.g., using Cerenkov luminescence imaging) can improve readout resolution, but the underlying chromatographic separation efficiency may be insufficient to resolve chemically similar species such as product and precursor-derived impurities. This study applies a systematic mobile phase optimization method, PRISMA, to improve radio-TLC resolution. The PRISMA method optimizes the mobile phase by selecting the correct solvent, optimizing solvent polarity, and optimizing composition. Without prior knowledge of impurities and by simply observing the separation resolution between a radiopharmaceutical and its nearest radioactive or non-radioactive impurities (observed via UV imaging) for different mobile phases, the PRISMA method enabled the development of high-resolution separation conditions for a wide range of 18F-radiopharmaceuticals ( [18F]PBR-06, [18F]FEPPA, [18F]Fallypride, [18F]FPEB, and [18F]FDOPA). Each optimization required a single batch of crude radiopharmaceutical and a few hours. Interestingly, the optimized TLC method provided greater accuracy (compared to other published TLC methods) in determining the product abundance of one radiopharmaceutical studied in more depth ( [18F]Fallypride) and was capable of resolving a comparable number of species as isocratic radio-HPLC. We used the PRISMA-optimized mobile phase for [18F]FPEB in combination with multi-lane radio-TLC techniques to evaluate reaction performance during high-throughput synthesis optimization of [18F]FPEB. The PRISMA methodology, in combination with high-resolution radio-TLC readout, enables a rapid and systematic approach to achieving high-resolution and accurate analysis of radiopharmaceuticals without the need for radio-HPLC.


Assuntos
Benzamidas , Compostos Radiofarmacêuticos , Cromatografia em Camada Fina/métodos , Cromatografia Líquida de Alta Pressão , Solventes
19.
Anal Chem ; 84(4): 1915-23, 2012 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-22248060

RESUMO

We demonstrate a new approach to impedance measurement on digital microfluidics chips for the purpose of simple, sensitive, and accurate volume and liquid composition measurement. Adding only a single series resistor to existing AC droplet actuation circuits, the platform is simple to implement and has negligible effect on actuation voltage. To accurately measure the complex voltage across the resistor (and hence current through the device and droplet), the designed system is based on software-implemented lock-in amplification detection of the voltage drop across the resistor which filters out noise, enabling high-resolution and low-limit signal recovery. We observe picoliter sensitivity with linear correlation of voltage to volume extending to the microliter volumes that can be handled by digital microfluidic devices. Due to the minimal hardware, the system is robust and measurements are highly repeatable. The detection technique provides both phase and magnitude information of the real-time current flowing through the droplet for a full impedance measurement. The sensitivity and resolution of this platform enables it to distinguish between various liquids which, as demonstrated in this paper, could potentially be extended to quantify solute concentrations, liquid mixtures, and presence of analytes.


Assuntos
Técnicas Biossensoriais , Impedância Elétrica , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos , Soluções/química , Simulação por Computador , Técnicas Analíticas Microfluídicas/instrumentação , Microfluídica/instrumentação , Modelos Teóricos
20.
Methods Mol Biol ; 2393: 813-828, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34837213

RESUMO

The short-lived radiolabeled "tracers" needed for performing whole body imaging in animals or patients with positron-emission tomography (PET) are generally produced via automated "radiosynthesizers". Most current radiosynthesizers are designed for routine production of relatively large clinical batches and are very wasteful when only a small batch of a tracer is needed, such as is the case for preclinical in vivo PET imaging studies. To overcome the prohibitively high cost of producing small batches of PET tracers, we developed a droplet microreactor system that performs radiochemistry at the 1-10µL scale instead of the milliliter scale of conventional technologies. The overall yield for the droplet-based production of many PET tracers is comparable to conventional approaches, but 10-100× less reagents are consumed, the synthesis can be completed in much less time (<30 min), and only a small laboratory footprint and minimal radiation shielding are needed. By combining these advantages, droplet microreactors enable the economical production of small batches PET tracers on demand. Here, we describe the fabrication method of the droplet microreactor and the droplet-based synthesis of an example radiotracer ([18F]fallypride).


Assuntos
Radioquímica , Animais , Humanos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA