Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Emerg Med ; 27(8): 1017.e1-2, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19857428

RESUMO

We report a case of a 49-year-old woman with a ruptured liver and spleen found at autopsy, which may have been related to the use of a mechanical cardiopulmonary resuscitation (CPR) device (AutoPulse, ZOLL Medical Corporation, Chelmsford, Mass). She was admitted because of an out-of-hospital resuscitation, and under the suspicion of a pulmonary embolism, a thrombolytic agent was administered. Despite prolonged continuation of mechanical CPR, she died of persistent asystole. The evidence for improved outcomes after the use of a mechanical CPR device during resuscitation is still scarce. To prevent the unique complications reported here, regular checking of proper position of the chest band during resuscitation is advised.


Assuntos
Reanimação Cardiopulmonar/efeitos adversos , Reanimação Cardiopulmonar/instrumentação , Fígado/lesões , Ruptura Esplênica/etiologia , Evolução Fatal , Feminino , Humanos , Doença Iatrogênica , Pessoa de Meia-Idade