Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Ann Surg ; 272(6): 919-924, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33021367

RESUMO

OBJECTIVE: To determine the yield of preoperative screening for COVID-19 with chest CT and RT-PCR in patients without COVID-19 symptoms. SUMMARY OF BACKGROUND DATA: Many centers are currently screening surgical patients for COVID-19 using either chest CT, RT-PCR or both, due to the risk for worsened surgical outcomes and nosocomial spread. The optimal design and yield of such a strategy are currently unknown. METHODS: This multicenter study included consecutive adult patients without COVID-19 symptoms who underwent preoperative screening using chest CT and RT-PCR before elective or emergency surgery under general anesthesia. RESULTS: A total of 2093 patients without COVID-19 symptoms were included in 14 participating centers; 1224 were screened by CT and RT-PCR and 869 by chest CT only. The positive yield of screening using a combination of chest CT and RT-PCR was 1.5% [95% confidence interval (CI): 0.8-2.1]. Individual yields were 0.7% (95% CI: 0.2-1.1) for chest CT and 1.1% (95% CI: 0.6-1.7) for RT-PCR; the incremental yield of chest CT was 0.4%. In relation to COVID-19 community prevalence, up to ∼6% positive RT-PCR was found for a daily hospital admission rate >1.5 per 100,000 inhabitants, and around 1.0% for lower prevalence. CONCLUSIONS: One in every 100 patients without COVID-19 symptoms tested positive for SARS-CoV-2 with RT-PCR; this yield increased in conjunction with community prevalence. The added value of chest CT was limited. Preoperative screening allowed us to take adequate precautions for SARS-CoV-2 positive patients in a surgical population, whereas negative patients needed only routine procedures.


Assuntos
Infecções Assintomáticas , COVID-19/diagnóstico , Tratamento de Emergência , Programas de Rastreamento/estatística & dados numéricos , Cuidados Pré-Operatórios/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2 , Procedimentos Cirúrgicos Operatórios , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Procedimentos Cirúrgicos Eletivos , Humanos , Estudos Retrospectivos
2.
Catheter Cardiovasc Interv ; 93(4): E248-E254, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30208263

RESUMO

OBJECTIVES: The aim of this study was to assess the predictive value of PMA measurement for mortality. BACKGROUND: Current surgical risk stratification have limited predictive value in the transcatheter aortic valve implantation (TAVI) population. In TAVI workup, a CT scan is routinely performed but body composition is not analyzed. Psoas muscle area (PMA) reflects a patient's global muscle mass and accordingly PMA might serve as a quantifiable frailty measure. METHODS: Multi-slice computed tomography scans (between 2010 and 2016) of 583 consecutive TAVI patients were reviewed. Patients were divided into equal sex-specific tertiles (low, mid, and high) according to an indexed PMA. Hazard ratios (HR) and their confidence intervals (CI) were determined for cardiac and all-cause mortality after TAVI. RESULTS: Low iPMA was associated with cardiac and all-cause mortality in females. One-year adjusted cardiac mortality HR in females for mid-iPMA and high-iPMA were 0.14 [95%CI, 0.05-0.45] and 0.40 [95%CI, 0.15-0.97], respectively. Similar effects were observed for 30-day and 2-years cardiac and all-cause mortality. In females, adding iPMA to surgical risk scores improved the predictive value for 1-year mortality. C-statistics changed from 0.63 [CI = 0.54-0.73] to 0.67 [CI: 0.58-0.75] for EuroSCORE II and from 0.67 [CI: 0.59-0.77] to 0.72 [CI: 0.63-0.80] for STS-PROM. CONCLUSIONS: Particularly in females, low iPMA is independently associated with an higher all-cause and cardiac mortality. Prospective studies should confirm whether PMA or other body composition parameters should be extracted automatically from CT-scans to include in clinical decision making and outcome prediction for TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Composição Corporal , Fragilidade/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Músculos Psoas/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Fragilidade/mortalidade , Fragilidade/fisiopatologia , Nível de Saúde , Humanos , Masculino , Valor Preditivo dos Testes , Músculos Psoas/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sarcopenia/mortalidade , Sarcopenia/fisiopatologia , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Eur Radiol ; 28(1): 257-264, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28710578

RESUMO

OBJECTIVES: To evaluate aortic velocity, wall shear stress (WSS) and viscous energy loss (EL) of stented and stentless bioprostheses using 4D flow MRI 1 year after surgical aortic valve replacement. METHODS: For this cross-sectional study 28 patients with stented (n = 14) or stentless (n = 14) bioprosthesis underwent non-contrast-enhanced 4D-flow MRI at 1.5 T. Analyses included a comparison of velocity, WSS and EL in the ascending aorta during peak systole for both spatially averaged values and a comparison of local differences using per-voxel analysis. RESULTS: No significant differences were found in peak and mean velocity (stented vs. stentless: 2.45 m/s vs. 2.11 m/s; p = 0.09 and 0.60 m/s vs. 0.62 m/s; p = 0.89), WSS (0.60 Pa vs. 0.59 Pa; p = 0.55) and EL (10.17 mW vs. 7.82 mW; p = 0.10). Per-voxel analysis revealed significantly higher central lumen velocity, and lower outer lumen velocity, WSS and EL for stentless versus stented prostheses. CONCLUSION: One year after aortic valve implantation with stented and stentless bioprostheses, velocity, WSS and EL were comparable when assessed for averaged values in the ascending aorta. However, the flow profile described with local analysis for stentless prosthesis is potentially favourable with a significantly higher central velocity profile and lower values for outer lumen velocity, WSS and EL. KEY POINTS: • Stentless bioprostheses can be implanted instead of stented aortic valve bioprostheses. • Haemodynamic performance of valve prosthesis can be assessed using 4D flow MRI. • Averaged ascending aorta PSV, WSS and EL are comparable 1 year post-implantation. • Centreline velocity is highest, WSS and EL is lowest for stentless prosthesis.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Próteses Valvulares Cardíacas , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Stents , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Estudos Transversais , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Desenho de Prótese , Reprodutibilidade dos Testes
4.
Am J Obstet Gynecol ; 216(5): 523.e1-523.e7, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28209494

RESUMO

BACKGROUND: Women with hypertensive disorders in pregnancy, in particular early-onset preeclampsia, are at increased risk of developing cardiovascular disease later in life. These women have a more than 2-fold increased risk of dying from cardiovascular diseases. Most studies have focused on identification of risk factors shortly after pregnancy. Less is known on the prevalence of risk factors or actual signs of cardiovascular disease 5-20 years later. The presence of hypertension or metabolic syndrome can be seen as an opportunity for preventive interventions to reduce the development of severe cardiovascular diseases like myocardial infarction and stroke. OBJECTIVE: To assess cardiovascular risk factors and established cardiovascular disease in women after early-onset preeclampsia, in the fifth decade of life. As a consequence, we can assess whether there is still a window of opportunity for preventive measures and to establish in what proportion of women cardiovascular disease already has developed. STUDY DESIGN: In a prospective observational study, cardiovascular risk assessment was performed in women with early-onset preeclampsia (<34 weeks' gestation) and normotensive controls (≥37 weeks' gestation) 9-16 years after their index pregnancy. Medical records of 2 tertiary hospitals in Amsterdam, The Netherlands, were screened consecutively, and all eligible women were invited. Cardiovascular risk assessment consisted of a questionnaire, blood pressure measurement, anthropometrics, and blood and urine for fasting lipids, lipoproteins, glucose levels, glycated hemoglobin, renal function, N-terminal brain natriuretic peptide, and albuminuria. History of cardiovascular diseases (ie, myocardial infarction and stroke) was determined. Prevalence of women presenting in an optimal window of opportunity for preventive measures was defined by the presence of cardiovascular risk factors (ie, hypertension and metabolic syndrome) but in the absence of established cardiovascular diseases (ie, myocardial infarction and stroke). RESULTS: Women with a history of early-onset preeclampsia (n = 131) had significantly greater systolic and diastolic blood pressure, greater body mass index, more often had an abnormal lipid profile (lower high-density lipoprotein levels, higher triglycerides), greater glycated hemoglobin, and greater levels of albuminuria compared to controls (n = 56). None of the women with a history of early-onset preeclampsia was diagnosed with cardiovascular disease; 38.2% were diagnosed with hypertension; and 18.2% were diagnosed with metabolic syndrome. A total of 42% met the criteria for the window of opportunity for preventive measures. In women with a history of an uncomplicated pregnancy, no women were diagnosed with cardiovascular disease; 14.3% were diagnosed with hypertension; 1.8% with metabolic syndrome. In this cohort, 14.3% met the criteria for the window of opportunity for preventive measures. CONCLUSION: A large proportion of women who experienced early-onset preeclampsia had major cardiovascular risk factors in the fifth decade of life, compared with healthy controls. These women are currently outside the scope of most preventive programs due to their relatively young age, but have important modifiable risk factors for cardiovascular diseases.


Assuntos
Doenças Cardiovasculares/epidemiologia , Pré-Eclâmpsia/epidemiologia , Adulto , Albuminúria/epidemiologia , Índice de Massa Corporal , Estudos de Casos e Controles , Feminino , Seguimentos , Hemoglobinas Glicadas/análise , Humanos , Hipertensão/epidemiologia , Lipídeos/sangue , Síndrome Metabólica/epidemiologia , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Gravidez , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Saúde da Mulher
5.
J Invasive Cardiol ; 33(10): E823-E832, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34609327

RESUMO

OBJECTIVES: To analyze the effect of percutaneous coronary intervention (PCI) before transcatheter aortic valve replacement (TAVR) on all-cause and cardiovascular mortality after TAVR, differentiating between significant proximal lesions and the non-proximal (residual) lesions. METHODS: An institutional TAVR database was complemented with data on the extent of coronary artery disease (CAD), lesion location, lesion severity, and the location of PCI. Survival analysis was performed to investigate the impact on 6-month and 3-year mortality after TAVR in all patients and in subgroups of patients with significant proximal lesions (>70% diameter stenosis [DS], >50% DS in left main), the non-proximal residual lesions, and in a propensity score matched cohort. RESULTS: Among the 577 included patients, mean age was 83 years, 50% were female, and 31% had diabetes mellitus. Preprocedural PCI of unselected lesions was independently associated with increased 6-month mortality (hazard ratio, 2.2; 95% confidence interval, 1.0-4.6; P=.04), but selective PCI of significant proximal lesions did not have an association with higher mortality, nor did we find a significant effect of PCI on mortality in the propensity-matched cohort. CONCLUSION: Routine pre-TAVR PCI is not associated with mortality reduction in TAVR patients with coronary lesions in any segment or in patients with proximal coronary lesions. Despite the lack of a beneficial effect of routine pre-TAVR PCI, we cannot exclude a beneficial effect in a selection of patients with proximal lesions. Therefore, we strongly support the current clinical guidelines to only consider pre-TAVR PCI in proximal coronary lesions, while advocating a restrictive pre-TAVR PCI strategy.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Am J Cardiol ; 121(12): 1581-1586, 2018 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-29627110

RESUMO

In patients who underwent transcatheter aortic valve implantation (TAVI), postoperative mortality risk is commonly assessed with risk scores such as the Society of Thoracic Surgeons-Postoperative Risk of Mortality (STS-PROM) and EuroSCORE II, in which age plays a dominant role. However, we reason that in the naturally selected oldest-old patients (nonagenarians), this may not be completely justified and that therefore age should play a minor role in decision-making. The objective of this study was to compare procedural outcome and mid-term mortality of transfemoral (TF)-TAVI patients aged ≥90 years with patients aged <90 years. In this single-center analysis of 599 prospectively acquired consecutive TF-TAVI patients between 2009 and 2017, we compared patients aged ≥90 (i.e., nonagenarians, n = 47) with patients aged <90 years (n = 552), using Kaplan-Meyer analysis and multivariate logistic regression. In the nonagenarians, we found more aortic regurgitation, moderate to severe paravalvular leakage, strokes and vascular complications, and less device success and bleeding complications compared with patients <90 years. Both groups showed similar symptomatic improvement. The predicted (STS-PROM) and actual procedural mortality were 8.033% and 2.1% (3.8×) and 4.868% and 1.8% (2.7×) for the nonagenarians and controls, respectively. Survival was not statistically different at the 1-, 2-, 3-, 4-, and 5-year mark. In conclusion, nonagenarians had similar symptomatic improvement and acceptable procedural outcome and mid-term survival to TF-TAVI patients aged <90 years. Thus, age is not a risk factor in predicting postoperative outcome and mortality and therefore should not be a reason to deny the oldest-old patient transfemoral TAVI.


Assuntos
Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Hemorragia Pós-Operatória/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Complicações Pós-Operatórias/epidemiologia , Modelos de Riscos Proporcionais , Resultado do Tratamento
7.
Open Heart ; 5(2): e000879, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30275957

RESUMO

Objective: Transcatheter aortic valve implantation (TAVI) provides a significant symptom relief and mortality reduction in most patients; however, a substantial group of patients does not experience the same beneficial results according to physician-determined outcomes. Methods: Single-centre prospective design; the population comprises all consecutive patients undergoing TAVI in 2012-2017. TAVI futility was defined as the combined endpoint of either no symptomatic improvement or mortality at 1 year. We actively gathered telephone follow-up using a predefined questionnaire. Results: Guideline defined TAVI futility was present in 212/741 patients. Multivariate regression showed lower albumin and non-transfemoral approach to be predictive for futility. In addition to these, chronic obstructive pulmonary disease, lower estimated glomerular filtration rate, atrial fibrillation, low-flow-low-gradient aortic stenosis and lower Body Mass Index were predictive for 1-year mortality. Patients who showed symptomatic benefit estimated the percentage in which their symptoms were remedied higher than patients who did not (80% vs 60%, p<0.001). Guideline-defined TAVI futility occurs frequently, contrasting with patient-reported outcome measures (PROMs). The vast majority in both groups would again choose for TAVI treatment. Conclusion: Lower albumin and non-transfemoral access route were predictors for guideline-defined TAVI futility, defined as mortality within 1 year or no objective symptomatic improvement in New York Heart Association class. Futility according to this definition occurred frequently in this study, contrasting with much more positive PROMs. The majority of patients would undergo a TAVI again, underlining the patients' experienced value of TAVI and putting the definition of TAVI futility further on debate. In the near future, less-strict criteria for TAVI futility, that is, using a shorter warranted life expectancy and incorporating patients' perceived outcomes, should be used.

8.
Am J Cardiol ; 121(7): 856-861, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29415808

RESUMO

Over the years increasing experience and technical device improvements in transcatheter aortic valve implantation (TAVI) have led to treatment of patients with lower surgical risks. Specifically for this population, device performance and longer term outcome are of great importance. In this single center, we performed a retrospective analysis of 515 consecutive patients with low- to intermediate surgical risk (STS-PROM ≤8), who underwent transfemoral TAVI between January 2009 and February 2017 with the SXT and ES3 prostheses, and we assessed procedural outcome and procedural and 3-year survival. Mean age (82 years in both groups, p = 0.344) and STS-PROM risk score (3.862 vs 3.992, p = 0.154) did not differ between the ES3 and SXT group. ES3-treated patients showed favorable procedural outcomes, with significantly higher device success (90% vs 73%, p <0.0001) and less paravalvular leakage (7% vs 13%, p <0.0001). Procedural mortality (0.87% vs 1.45%, p = 0.245) and the very low rate of permanent pacemaker implantations (7.4% vs 6.1%, p = 0.234) did not differ significantly. Three-year survival was 87% in the ES3 vs 80% in the SXT group (log-rank p = 0.385). In conclusion, we showed excellent survival and procedural outcomes in patients receiving a transfemoral TAVI with either the SAPIEN 3 or the SAPIEN XT device. The newer SAPIEN 3 even outperforms the SAPIEN XT in terms of less major bleeding complications, substantially higher device success rates, and less paravalvular leakage, with the permanent pacemaker implantation rate being very low in both groups. Survival curves show a nonsignificant trend toward better midterm survival in the ES3 group.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Marca-Passo Artificial , Hemorragia Pós-Operatória/epidemiologia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Taxa de Sobrevida , Resultado do Tratamento
9.
Am J Cardiol ; 121(10): 1231-1238, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29703437

RESUMO

Vascular complications (VCs) after transfemoral transcatheter aortic valve implantation (TAVI) have always been reported to occur frequently. Studies addressing VCs have been conducted with older-generation prostheses. We aimed to evaluate the incidence, predictors, and impact of VCs after transfemoral TAVI with the balloon-expandable SAPIEN 3. We report a single-center retrospective analysis of 400 consecutive patients of a prospectively acquired cohort. All patients underwent transfemoral TAVI with SAPIEN 3 between January 2014 and December 2016. VC was defined according to the Valve Academic Research Consortium. In this cohort 83 patients had VCs (20.8%), 5.8% major and 15.0% minor. Sheath-to-iliofemoral artery ratio was the only predictor of major VCs (odds ratio 7.51, 95% confidence interval 1.61 to 34.95, p = 0.010). The area under the receiver-operator characteristic curve for sheath-to-iliofemoral artery ratio was 0.63 (poor accuracy). Thirty-day mortality rates were 17.4%, 1.7%, and 0.6% for major, minor, and no VCs, respectively (log-rank p ≤0.001). After adjustment, only major VCs were associated with 30-day mortality (adjusted hazard ratio 48.31, 95% confidence interval 7.80 to 299.24). Mortality from 30 days until 1 year did not differ between patients with and without VCs (log-rank p = 0.61). In conclusion we report that VCs remain an issue of transfemoral TAVI with the SAPIEN 3, and their prediction continues to be difficult, albeit the low-incidence, major VCs were associated with higher 30-day mortality. However, after these first 30 days, they were not of influence on survival anymore.


Assuntos
Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/epidemiologia , Falso Aneurisma/epidemiologia , Angiografia por Tomografia Computadorizada , Falha de Equipamento/estatística & dados numéricos , Feminino , Artéria Femoral/anatomia & histologia , Próteses Valvulares Cardíacas , Ventrículos do Coração/lesões , Hematoma/epidemiologia , Humanos , Artéria Ilíaca/anatomia & histologia , Incidência , Modelos Logísticos , Masculino , Mortalidade , Tamanho do Órgão , Hemorragia Pós-Operatória/epidemiologia , Desenho de Prótese , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Dispositivos de Oclusão Vascular
10.
Med Eng Phys ; 39: 123-128, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27913175

RESUMO

Minimally invasive aortic valve replacement (mini-AVR) procedures are a valuable alternative to conventional open heart surgery. Currently, planning of mini-AVR consists of selection of the intercostal space closest to the sinotubular junction on preoperative computer tomography images. We developed an automated algorithm detecting the sinotubular junction (STJ) and intercostal spaces for finding the optimal incision location. The accuracy of the STJ detection was assessed by comparison with manual delineation by measuring the Euclidean distance between the manually and automatically detected points. In all 20 patients, the intercostal spaces were accurately detected. The median distance between automated and manually detected STJ locations was 1.4 [IQR= 0.91-4.7] mm compared to the interobserver variation of 1.0 [IQR= 0.54-1.3] mm. For 60% of patients, the fourth intercostal space was the closest to the STJ. The proposed algorithm is the first automated approach for detecting optimal incision location and has the potential to be implemented in clinical practice for planning of various mini-AVR procedures.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Implante de Prótese de Valva Cardíaca , Procedimentos Cirúrgicos Minimamente Invasivos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Automação , Feminino , Humanos , Masculino
11.
Am J Cardiol ; 120(6): 994-1001, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28774429

RESUMO

Computed tomography angiography (CTA) in workup for transcatheter aortic valve implantation (TAVI) frequently reveals potentially malignant incidental findings. Most incidental findings provoke discussions on their influence. We aimed to analyze if these findings were a predictor of long-term survival after TAVI. In a single-center retrospective analysis, all consecutive patients with pre-TAVI CTA were included (years 2009 to 2014). Patients were divided by presence or absence of incidental findings. We analyzed up to 5 years of all-cause, non-cardiovascular and cardiovascular mortality for all 553 patients who underwent TAVI; 113 had a potentially malignant incidental finding (20.4%). At 5 years, all-cause mortality risk was 64.5% in patients with versus 49.1% in patients without a finding (hazard ratio [HR] 1.70, 95% confidence interval [CI] 1.25 to 2.31). After adjustment, the findings remained an independent predictor of all-cause (adjusted HR 1.46, 95% CI 1.07 to 1.99) and non-cardiovascular mortality (adjusted subdistribution HR 1.84, 95% CI 1.06 to 3.20), but not of cardiovascular mortality. In conclusion, the presence of potentially malignant incidental findings on CTA is an independent predictor of long-term all-cause and noncardiovascular mortality but not of cardiovascular mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Achados Incidentais , Neoplasias/diagnóstico , Medição de Risco , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Causas de Morte/tendências , Feminino , Seguimentos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Neoplasias/complicações , Neoplasias/epidemiologia , Países Baixos/epidemiologia , Período Pós-Operatório , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo
12.
Expert Rev Med Devices ; 13(1): 31-45, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26567756

RESUMO

Over the past decade transcatheter aortic valve implantation (TAVI) has evolved towards the routine therapy for high-risk patients with severe aortic valve stenosis. Technical refinements in TAVI are rapidly evolving with a simultaneous expansion of the number of available devices. This review will present an overview of the current status of development of TAVI-prostheses; describes the technical features and applicability of each device and the clinical data available.


Assuntos
Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Ensaios Clínicos como Assunto , Humanos , Stents Metálicos Autoexpansíveis , Resultado do Tratamento
13.
Int J Cardiovasc Imaging ; 32(3): 501-11, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26498339

RESUMO

Transcatheter aortic valve implantation is currently a well-established minimal invasive treatment option for patients with severe aortic valve stenosis. CT Angiography is used for the pre-operative planning and sizing of the prosthesis. To reduce the inconsistency in sizing due to interobserver variability, we introduce and evaluate an automatic aortic root landmarks detection method to determine the sizing parameters. The proposed algorithm detects the sinotubular junction, two coronary ostia, and three valvular hinge points on a segmented aortic root surface. Using these aortic root landmarks, the automated method determines annulus radius, annulus orientation, and distance from annulus plane to right and left coronary ostia. Validation is performed by the comparison with manual measurements of two observers for 40 CTA image datasets. Detection of landmarks showed high accuracy where the mean distance between the automatically detected and reference landmarks was 2.81 ± 2.08 mm, comparable to the interobserver variation of 2.67 ± 2.52 mm. The mean annulus to coronary ostium distance was 16.9 ± 3.3 and 17.1 ± 3.3 mm for the automated and the reference manual measurements, respectively, with a mean paired difference of 1.89 ± 1.71 mm and interobserver mean paired difference of 1.38 ± 1.52 mm. Automated detection of aortic root landmarks enables automated sizing with good agreement with manual measurements, which suggests applicability of the presented method in current clinical practice.


Assuntos
Pontos de Referência Anatômicos , Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese de Valva Cardíaca/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Cateterismo Cardíaco/instrumentação , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes
14.
Hypertens Pregnancy ; 35(1): 55-61, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26910620

RESUMO

OBJECTIVE: Women with a history of preeclampsia have an increased risk of cardiovascular disease. Gynaecologists have an important role in the counselling and management of cardiovascular risk factors after preeclampsia. We aimed to assess the role of gynaecologists in informing women on interventions and risk factor follow-up after early and late preeclampsia. METHODS: In 2011 and 2014, all gynaecologists in the Netherlands were invited for a questionnaire. Results were analysed and compared over time. RESULTS: In 2011, the questionnaire was answered by 244 and in 2014 by 167 gynaecologists. After early preeclampsia, in 2011, 53% advised yearly blood pressure measurements; this increased to 65% in 2014. Over the years there was an increase in respondents advising an increased physical activity of 35% in 2011 to 56% in 2014. After late preeclampsia, in 2011, 36% advised yearly blood pressure measurements; this increased to 46% in 2014. There was an increase in gynaecologists advising increased activity (32% in 2011 to 56% in 2014). In both early and late preeclampsia, smoking cessation and weigh loss were advised often (70-80%); glucose and lipid screening were advised rarely (6-20%). CONCLUSION: Although there is still a considerable scope for improvement, an increasing number of gynaecologists advise women after preeclampsia on preventive interventions to decrease risks of cardiovascular disease.


Assuntos
Pressão Sanguínea/fisiologia , Doenças Cardiovasculares/prevenção & controle , Pré-Eclâmpsia/fisiopatologia , Adulto , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/fisiopatologia , Aconselhamento , Exercício Físico , Feminino , Seguimentos , Humanos , Estilo de Vida , Programas de Rastreamento , Pessoa de Meia-Idade , Gravidez , Medição de Risco , Fatores de Risco , Abandono do Hábito de Fumar
15.
EuroIntervention ; 12(4): 499-507, 2016 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-27436602

RESUMO

AIMS: Our aim was to determine whether use of the filter-based Sentinel™ Cerebral Protection System (CPS) during transcatheter aortic valve implantation (TAVI) can affect the early incidence of new brain lesions, as assessed by diffusion-weighted magnetic resonance imaging (DW-MRI), and neurocognitive performance. METHODS AND RESULTS: From January 2013 to July 2015, 65 patients were randomised 1:1 to transfemoral TAVI with or without the Sentinel CPS. Patients underwent DW-MRI and extensive neurological examination, including neurocognitive testing one day before and five to seven days after TAVI. Follow-up DW-MRI and neurocognitive testing was completed in 57% and 80%, respectively. New brain lesions were found in 78% of patients with follow-up MRI. Patients with the Sentinel CPS had numerically fewer new lesions and a smaller total lesion volume (95 mm3 [IQR 10-257] vs. 197 mm3 [95-525]). Overall, 27% of Sentinel CPS patients and 13% of control patients had no new lesions. Ten or more new brain lesions were found only in the control cohort (in 20% vs. 0% in the Sentinel CPS cohort, p=0.03). Neurocognitive deterioration was present in 4% of patients with Sentinel CPS vs. 27% of patients without (p=0.017). The filters captured debris in all patients with Sentinel CPS protection. CONCLUSIONS: Filter-based embolic protection captures debris en route to the brain in all patients undergoing TAVI. This study suggests that its use can lead to fewer and overall smaller new brain lesions, as assessed by MRI, and preservation of neurocognitive performance early after TAVI. CLINICAL TRIAL REGISTRATION: Dutch trial register-ID: NTR4236. URL http://www.trialregister.nl/trialreg/admin/rctsearch.asp?Term=mistral.


Assuntos
Estenose da Valva Aórtica/cirurgia , Isquemia Encefálica/terapia , Dispositivos de Proteção Embólica , Embolia Intracraniana/prevenção & controle , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Testes Neuropsicológicos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
16.
Circ Cardiovasc Interv ; 8(8): e002443, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26245891

RESUMO

BACKGROUND: Aortic valve stenosis (AS) induces compensatory alterations in left ventricular hemodynamics, leading to physiological and pathological alterations in coronary hemodynamics. Relief of AS by transcatheter aortic valve implantation (TAVI) decreases ventricular afterload and is expected to improve microvascular function immediately. We evaluated the effect of AS on coronary hemodynamics and the immediate effect of TAVI. METHODS AND RESULTS: Intracoronary pressure and flow velocity were simultaneously assessed at rest and at maximal hyperemia in an unobstructed coronary artery in 27 patients with AS before and immediately after TAVI and in 28 patients without AS. Baseline flow velocity was higher and baseline microvascular resistance was lower in patients with AS as compared with controls, which remained unaltered post-TAVI. In patients with AS, hyperemic flow velocity was significantly lower as compared with controls (44.5±14.5 versus 54.3±18.6 cm/s; P=0.04). Hyperemic microvascular resistance (expressed in mm Hg·cm·s(-1)) was 2.10±0.69 in patients with AS as compared with 1.80±0.60 in controls (P=0.096). Coronary flow velocity reserve in patients with AS was lower, 1.9±0.5 versus 2.7±0.7 in controls (P<0.001). Improvement in coronary hemodynamics after TAVI was most pronounced in patients without post-TAVI aortic regurgitation. In these patients (n=20), hyperemic flow velocity increased significantly from 46.24±15.47 pre-TAVI to 56.56±17.44 cm/s post-TAVI (P=0.003). Hyperemic microvascular resistance decreased from 2.03±0.71 to 1.66±0.45 (P=0.050). Coronary flow velocity reserve increased significantly from 1.9±0.4 to 2.2±0.6 (P=0.009). CONCLUSIONS: The vasodilatory reserve capacity of the coronary circulation is reduced in AS. TAVI induces an immediate decrease in hyperemic microvascular resistance and a concomitant increase in hyperemic flow velocity, resulting in immediate improvement in coronary vasodilatory reserve.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Vasos Coronários/fisiologia , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Circulação Coronária/fisiologia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade
17.
Hypertens Pregnancy ; 34(2): 261-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25815424

RESUMO

OBJECTIVE: To analyse preventive interventions of women with cardiovascular risk factors postpartum. METHODS: 3.5 years postpartum, women with history of hypertension in pregnancy were invited for a questionnaire, 1 year after a cardiovascular risk assessment. RESULTS: Two hundred and fifty-seven women completed the questionnaire. At risk factor analyses, 35% had hypertension, 37% abnormal lipid- or glucose levels, 63% BMI ≥ 25 and 19% smoked. One year later, 36% of women with hypertension used anti-hypertensives, 0% of women with abnormal laboratory findings used anti-cholesterol and 1% anti-diabetes medication, 31% of the obese women achieved BMI reduction (≥ 5%), 42% of the women who smoked, quit. CONCLUSION: A minority improved their risk profile.


Assuntos
Anti-Hipertensivos/uso terapêutico , Doenças Cardiovasculares/prevenção & controle , Hipertensão Induzida pela Gravidez/tratamento farmacológico , Período Pós-Parto , Comportamento de Redução do Risco , Doenças Cardiovasculares/epidemiologia , Estudos de Coortes , Feminino , Seguimentos , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Hipertensão Induzida pela Gravidez/epidemiologia , Obesidade/complicações , Período Pós-Parto/sangue , Gravidez , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Inquéritos e Questionários
18.
J Vasc Access ; 15 Suppl 7: S114-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24817467

RESUMO

A patent vascular access is the lifeline of end-stage renal disease patients depending on hemodialysis treatment. Once a functioning vascular access has been established, maintaining its patency is of utmost importance. During the last decades percutaneous techniques became increasingly important for the treatment of hemodialysis vascular access graft failure. In this review, the role of percutaneous balloon angioplasty and stent implantation is evaluated for different clinical scenarios, based on the available evidence.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Diálise Renal , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Fluxo Sanguíneo Regional , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA