Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int Orthop ; 48(3): 643-649, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38015209

RESUMO

PURPOSE: The number of seven required throws per knot was previously reported as providing sufficient security against slippage. A novel high-strength suture featuring dynamic tightening may allow for throw number reduction without compromising stability. The aims of this study were to (1) investigate the influence of the throw number and the effect of different ambient conditions on the knot security of two different high-strength sutures, and (2) compare their biomechanical competence. METHODS: Two sutures (FiberWire (FW) and DynaCord (DC)) were considered for preparing alternating surgical knots. The specimens were stratified for exposure to different media during biomechanical testing-namely air (dry), saline solution (wet), and fat (fatty-wet). A monotonic tensile ramp loading to failure was applied in each test run. For each suture and ambient condition, seven specimens with three to seven throws each were tested (n = 7), evaluating their slippage and ultimate force to failure. The minimum number of throws preventing suture unraveling was determined for each suture type and condition. RESULTS: For each suture type and condition, failure occurred via rupture in all specimens for the following minimum number of throws: FW-dry-7, wet-7, fatty-wet-7; DC-dry-6, wet-4, fatty-wet-5. When applying seven throws, FW demonstrated significantly larger slippage (6.5 ± 2.2 mm) versus DC (3.5 ± 0.4 mm) in wet (p = 0.004) but not in dry and fatty-wet conditions (p ≥ 0.313). CONCLUSIONS: The lower number of throws providing knot security of DC versus FW in the more realistic wet and fatty-wet conditions indicates that the novel DC suture may allow to decrease the foreign body volume and save surgical time without compromising the biomechanical competence.


Assuntos
Técnicas de Sutura , Suturas , Humanos , Teste de Materiais , Resistência à Tração , Ruptura , Técnicas de Sutura/efeitos adversos
2.
Arch Orthop Trauma Surg ; 143(8): 4983-4991, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36821049

RESUMO

BACKGROUND: Proximal humeral shaft fractures are surgically challenging and plate osteosynthesis with a long straight plate is one operative treatment option in these patients although endangering the radial nerve distally. Helical plates potentially avoid the radial nerve by twisting around the humeral shaft. Aim of the study was to investigate in a human cadaveric model the biomechanical competence of helical plates versus straight lateral plates used for fixation of proximal third comminuted humeral shaft fractures. METHODS: Eight pairs of humeral cadaveric humeri were instrumented using either a long 90°-helical plate (Group1) or a straight long PHILOS plate (Group2). An unstable proximal humeral shaft fracture was simulated by means of a 5 cm osteotomy gap. All specimens were tested under quasi-static loading in axial compression, internal and external rotation, and bending in four directions. Subsequently, progressively increasing cyclic loading in internal rotation until failure was applied and interfragmentary movements were monitored by motion tracking. RESULTS: During static testing flexion/extension deformation in Group1 was significantly higher, however, varus/valgus deformation as well as shear and torsional displacement under torsional load remained statistically indifferent between both groups. During cyclic testing shear and torsional displacements were both significantly higher in Group1 compared to Group 2. However, cycles to catastrophic failure remained statistically indifferent between the groups. CONCLUSIONS: From a biomechanical perspective, although 90°-helical plating is associated with higher initial stability against varus/valgus collapse and comparable endurance under dynamic loading, it demonstrates lower resistance to flexion/extension and internal rotation with bigger shear interfragmentary displacements versus straight lateral plating and, therefore, cannot be considered as its real alternative. Alternative helical plate designs should be investigated in the future.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Humanos , Fenômenos Biomecânicos , Fixação Interna de Fraturas , Placas Ósseas , Fraturas do Úmero/cirurgia , Úmero , Fraturas do Ombro/cirurgia , Cadáver
3.
Medicina (Kaunas) ; 59(11)2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-38004092

RESUMO

Background and Objectives: The surgical treatment of proximal humeral shaft fractures usually considers application of either long straight plates or intramedullary nails. By being able to spare the rotator cuff and avoid the radial nerve distally, the implementation of helical plates might overcome the downsides of common fixation methods. The aims of the current study were (1) to explore the biomechanical competence of different plate designs and (2) to compare their performance versus the alternative treatment option of using intramedullary nails. Materials and Methods: Twenty-four artificial humeri were assigned to the following four groups for simulation of an unstable proximal humeral shaft fracture and instrumentation: Group 1 (Straight-PHILOS), Group 2 (MULTILOC-Nail), Group 3 (45°-Helical-PHILOS), and Group 4 (90°-Helical-PHILOS). All specimens underwent non-destructive, quasi-static biomechanical testing under loading in axial compression, torsion in internal/external rotation, and pure bending in four directions, accompanied by motion tracking. Results: Axial stiffness/displacement in Group 2 was significantly higher/smaller than in all other groups (p ≤ 0.010). Torsional displacement in Group 2 was significantly bigger than in all other groups (p ≤ 0.017). Significantly smaller coronal plane displacement was identified in Group 2 versus all other groups (p < 0.001) and in Group 4 versus Group 1 (p = 0.022). Significantly bigger sagittal plane displacement was detected in Group 4 versus all other groups (p ≤ 0.024) and in Group 1 versus Group 2 (p < 0.001). Conclusions: Intramedullary nails demonstrated higher axial stiffness and smaller axial interfragmentary movements compared with all investigated plate designs. However, they were associated with bigger torsional movements at the fracture site. Although 90°-helical plates revealed bigger interfragmentary movements in the sagittal plane, they demonstrated improved resistance against displacements in the coronal plane when compared with straight lateral plates. In addition, 45°-helical plates manifested similar biomechanical competence to straight plates and may be considered a valid alternative to the latter from a biomechanical standpoint.


Assuntos
Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/métodos , Pinos Ortopédicos , Fenômenos Biomecânicos , Fixação Interna de Fraturas , Úmero , Placas Ósseas
4.
Medicina (Kaunas) ; 57(9)2021 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-34577807

RESUMO

Background and Objectives: Wound infections provoked by alterations in microcirculation are major complications in the treatment of trochanteric femur fractures. Surgical fracture fixation on a traction table is the gold standard for treatment, but the effect on tissue microcirculation is unknown. Microcirculation could be impaired by the pull on the soft-tissue or by a release of vasoactive factors. We hypothesized that intraoperative traction impairs soft-tissue microcirculation. Materials and Methods: In 22 patients (14 women, eight men), average age 78 years (range 36-96 ± 14), with trochanteric femur fractures, non-invasive laser-Doppler spectrophotometry was used to assess oxygen saturation, hemoglobin content, and blood flow in the skin and subcutaneous tissue before and after application of traction. Measurements were recorded in nine locations around the greater trochanter at a depth of 2, 8, and 15 mm before and after fracture reduction by traction. Results: No differences were found in any depth with traction compared to without (oxygen saturation: p = 0.751, p = 0.308, and p = 0.955, haemoglobin content: p = 0.651, p = 0.928, and p = 0.926, blood flow: p = 0.829, p = 0.866, and p = 0.411). Conclusion: In this pilot study, the application of traction does not affect skin and subcutaneous microcirculation in the surgery of proximal femur fractures.


Assuntos
Fraturas do Fêmur , Tração , Adulto , Feminino , Fraturas do Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Masculino , Microcirculação , Pessoa de Meia-Idade , Projetos Piloto , Adulto Jovem
5.
Sci Rep ; 13(1): 17750, 2023 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-37853088

RESUMO

Lateral wall thickness is a known predictor for postoperative stability of trochanteric femoral fractures and occurrence of secondary lateral wall fractures. Currently, the AO/OTA classification relies on the absolute lateral wall thickness (aLWT) to distinguish between stable A1.3 and unstable A2.1 fractures that does not take interpersonal patient differences into account. Thus, a more individualized and accurate measure would be favorable. Therefore, we proposed and validated a new patient-specific measure-the relative lateral wall thickness (rLWT)-to consider individualized measures and hypothesized its higher sensitivity and specificity compared with aLWT. First, in 146 pelvic radiographs of patients without a trochanteric femoral fracture, the symmetry of both caput-collum-diaphyseal angle (CCD) and total trochanteric thickness (TTT) was assessed to determine whether the contralateral side can be used for rLWT determination. Then, data of 202 patients were re-evaluated to compare rLWT versus previously published aLWT. Bilateral symmetry was found for both CCD and TTT (p ≥ 0.827), implying that bone morphology and geometry of the contralateral intact side could be used to calculate rLWT. Validation revealed increased accuracy of the rLWT compared with the gold standard aLWT, with increased specificity by 3.5% (Number Needed to Treat = 64 patients) and sensitivity by 1% (Number Needed to Treat = 75 patients). The novel rLWT is a more accurate and individualized predictor of secondary lateral wall fractures compared with the standard aLWT. This study established the threshold of 50.5% rLWT as a reference value for predicting fracture stability in trochanteric femoral fractures.


Assuntos
Parafusos Ósseos , Fraturas do Quadril , Humanos , Resultado do Tratamento , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Fixação Interna de Fraturas , Fêmur/diagnóstico por imagem , Fêmur/cirurgia
6.
Spine (Phila Pa 1976) ; 47(17): 1212-1220, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35853162

RESUMO

STUDY DESIGN: Laboratory study. OBJECTIVE: This study aimed to investigate the biomechanical competence and fracture characteristics of the odontoid process. SUMMARY OF BACKGROUND DATA: Odontoid fractures of the second cervical vertebra (C2) represent the most common spine fracture type in the elderly. However, very little is known about the underlying biomechanical fracture mechanisms. MATERIALS AND METHODS: A total of 42 C2 human anatomic specimens were scanned via computed tomography, divided in six groups, and subjected to combined quasistatic loading at -15°, 0°, and 15° in sagittal plane and -50° and 0° in transverse plane until fracturing. Bone mineral density (BMD), height, fusion state of the ossification centers, stiffness, yield load, and ultimate load were assessed. RESULTS: While lowest values for stiffness, yield load, and ultimate load were observed at load inclination of 15° in sagittal plane, no statistically significant differences were observed between the study groups ( P ≥0.235). BMD correlated positively with yield load ( r2 =0.350, P <0.001) and ultimate load ( r2 =0.955, P <0.001) but not with stiffness ( r2 =0.082, P =0.07). The specimens with clearly distinguishable fusion of the ossification centers revealed less data scattering of the biomechanical outcomes. CONCLUSION: Load direction plays a subordinate role in traumatic fractures of the odontoid process. BMD was associated with significant correlation to the biomechanical outcomes. Thus, odontoid fractures appear to result from of an interaction between the load magnitude and bone quality.


Assuntos
Fraturas Ósseas , Processo Odontoide , Fraturas da Coluna Vertebral , Idoso , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Humanos , Processo Odontoide/diagnóstico por imagem , Processo Odontoide/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem
7.
Front Bioeng Biotechnol ; 10: 1000624, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36406221

RESUMO

The purpose of this study was to compare the biomechanical stability, especially graft slippage of an allograft screw and a conventional interference screw for tibial implant fixation in ACL reconstruction. Twenty-four paired human proximal tibia specimens underwent ACL reconstruction, with the graft in one specimen of each pair fixed using the allograft screw and the other using the conventional interference screw. Specimens were subjected to cyclic tensile loading until failure. The two fixation methods did not show any statistical difference in load at graft slippage (p = 0.241) or estimated mean survival until slippage onset (p = 0.061). The ultimate load and the estimated mean survival until failure were higher for the interference screw (p = 0.04, and p = 0.018, respectively). Graft displacement at ultimate load reached values of up to 7.2 (interference screw) and 11.3 mm (allograft screw). The allograft screw for implant fixation in ACL reconstruction demonstrated comparable behavior in terms of graft slippage to the interference screw but underperformed in terms of ultimate load. However, the ultimate load, occurring at progressive graft slippage, may not be considered a direct indicator of clinical failure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA