Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Ann Surg ; 276(5): 913-920, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35894448

RESUMO

OBJECTIVE: The aim was to compare the (sentinel) lymph node detection rate of indocyanine green (ICG)-fluorescent imaging versus standard-of-care 99m Tc-nanocoilloid for sentinel lymph node (SLN)-mapping. BACKGROUND: The current gold standard for axillary staging in patients with breast cancer is sentinel lymph node biopsy (SLNB) using radio-guided surgery using radioisotope technetium ( 99m Tc), sometimes combined with blue dye. A promising alternative is fluorescent imaging using ICG. METHODS: In this noninferiority trial, we enrolled 102 consecutive patients with invasive early-stage, clinically node-negative breast cancer. Patients were planned for breast conserving surgery and SLNB between August 2020 and June 2021. The day or morning before surgery, patients were injected with 99m Tc-nanocolloid. In each patient, SLNB was first performed using ICG-fluorescent imaging, after which excised lymph nodes were tested with the gamma-probe for 99m Tc-uptake ex vivo, and the axilla was checked for residual 99m Tc-activity. The detection rate was defined as the proportion of patients in whom at least 1 (S)LN was detected with either tracer. RESULTS: In total, 103 SLNBs were analyzed. The detection rate of ICG-fluorescence was 96.1% [95% confidence interval (95% CI)=90.4%-98.9%] versus 86.4% (95% CI=78.3%-92.4%) for 99m Tc-nanocoilloid. The detection rate for pathological lymph nodes was 86.7% (95% CI=59.5%-98.3%) for both ICG and 99m Tc-nanocoilloid. A median of 2 lymph nodes were removed. ICG-fluorescent imaging did not increase detection time. No adverse events were observed. CONCLUSIONS: ICG-fluorescence showed a higher (S)LN detection rate than 99m Tc-nanocoilloid, and equal detection rate for pathological (S)LNs. ICG-fluorescence may be used as a safe and effective alternative to 99m Tc-nanocoilloid for SLNB in patients with early-stage breast cancer.


Assuntos
Neoplasias da Mama , Linfonodo Sentinela , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Corantes , Feminino , Humanos , Verde de Indocianina , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Linfocintigrafia/métodos , Compostos Radiofarmacêuticos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/patologia , Linfonodo Sentinela/cirurgia , Biópsia de Linfonodo Sentinela/métodos , Tecnécio , Agregado de Albumina Marcado com Tecnécio Tc 99m
2.
Urol Int ; 89(3): 326-31, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22986952

RESUMO

INTRODUCTION: The aim of this study is to evaluate the quality of photodynamic diagnosis (PDD) and transurethral resection of bladder tumors (TURBT) among different urologists. PATIENTS AND METHODS: The selected data consists of 194 patients, 268 5-aminolevulinic acid (5-ALA)-induced PDD procedures and 934 biopsies. Tumors were resected and biopsies were taken from suspicious areas under guidance of white light endoscopy and 5-ALA-induced fluorescence cystoscopy. The quality of PDD was determined by evaluating the mean number of tumors resected by 5 urologists and, thereafter, assessing the time to recurrence between groups. RESULTS: Urologist 1 took 37% more biopsies (p < 0.001) and diagnosed 42% more tumors (p = 0.005) and 46% more false positives (p < 0.001) from bladders compared to urologists 2, 3, 4 and 5 together. The mean time to bladder cancer recurrence for all recurrences within 0-18 months was 11.0 months for operator 1 and 8.3 months for the other urologists (p = 0.01). CONCLUSIONS: The resecting urologist appears to be an important factor for the quality of standard and PDD-assisted TURBT. Learning curve programs may be required with experienced surgeons accompanying those with less experience.


Assuntos
Ácido Aminolevulínico/farmacologia , Fotoquimioterapia/métodos , Neoplasias da Bexiga Urinária/cirurgia , Neoplasias da Bexiga Urinária/terapia , Urologia/métodos , Idoso , Biópsia/métodos , Cistoscopia/métodos , Reações Falso-Positivas , Feminino , Humanos , Masculino , Oncologia/métodos , Pessoa de Meia-Idade , Recidiva , Reprodutibilidade dos Testes , Fatores de Tempo
3.
Minim Invasive Ther Allied Technol ; 21(3): 241-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22455616

RESUMO

BACKGROUND: Precise laparoscopic liver resection requires accurate planning and visualization of important anatomy such as vessels and tumors. Combining laparoscopic ultrasound with navigation technology could provide this. Preoperative images are valuable for planning and overview of the procedure, while intraoperative images provide an updated view of the surgical field. PURPOSE: To validate the accuracy of navigation technology based on preoperative images, we need to understand how much the liver shifts and deforms due to heartbeat, breathing, surgical manipulation and pneumoperitoneum. In this study, we evaluated liver tumor shift and deformation due to pneumoperitoneum in an animal model. METHODS: Tumor models were injected into the liver of the animal, and 3D CT images were acquired before and after insufflation. Tumor shifts and deformation were determined. RESULTS: The results showed significant tumor position shift due to pneumoperitoneum, with a maximum of 28 mm in cranio-caudal direction. No significant tumor deformation was detected. Small standard deviations suggest rigid body transformation of the liver as a whole, but this needs further investigation. CONCLUSION: The findings indicate a need for anatomic shift correction of preoperative images before they are used in combination with LUS guidance during a laparoscopic liver resection procedure.


Assuntos
Laparoscopia/efeitos adversos , Neoplasias Hepáticas/cirurgia , Fígado/cirurgia , Pneumoperitônio/cirurgia , Cirurgia Assistida por Computador/métodos , Animais , Modelos Animais de Doenças , Cuidados Intraoperatórios , Laparoscopia/instrumentação , Laparoscopia/métodos , Neoplasias Hepáticas/patologia , Pneumoperitônio/patologia , Cuidados Pré-Operatórios , Cirurgia Assistida por Computador/instrumentação , Suínos
4.
J Neuromuscul Dis ; 8(2): 185-207, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33337383

RESUMO

Small fiber neuropathy (SFN) is a disorder of the small myelinated Aδ-fibers and unmyelinated C-fibers [5, 6]. SFN might affect small sensory fibers, autonomic fibers or both, resulting in sensory changes, autonomic dysfunction or combined symptoms [7]. As a consequence, the symptoms are potentially numerous and have a large impact on quality of life [8]. Since diagnostic methods for SFN are numerous and its pathophysiology complex, this extensive review focusses on categorizing all aspects of SFN as disease and its diagnosis. In this review, sensitivity in combination with specificity of different diagnostic methods are described using the areas under the curve. In the end, a diagnostic work-flow is suggested based on different phenotypes of SFN.


Assuntos
Neuropatia de Pequenas Fibras/diagnóstico , Doenças do Sistema Nervoso Autônomo/diagnóstico , Biópsia , Feminino , Humanos , Masculino , Fibras Nervosas Amielínicas , Qualidade de Vida
5.
Anal Chem ; 82(14): 5993-9, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20524627

RESUMO

We studied the feasibility of Raman spectroscopy for the diagnosis of bladder cancer in vivo. Since the invasion stage is crucial for the treatment choice, a high-volume based Raman probe was used to investigate the potential of determining the invasiveness of bladder cancer. High quality spectra were obtained from suspicious and nonsuspicious bladder locations during the procedure of transurethral resection of bladder tumors (TURBT) with collection times of 1-5 s. Multivariate analysis was used to generate the classification models. The algorithm was able to distinguish bladder cancer from normal bladder locations with a sensitivity of 85% and a specificity of 79%. The Raman spectra of bladder cancer stages showed a gradual increase in the intensity of specific amino acid peaks and, most likely, an increase in the intensity of DNA peaks.


Assuntos
Análise Espectral Raman/métodos , Neoplasias da Bexiga Urinária/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Aminoácidos/química , DNA/química , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada
6.
J Biomed Opt ; 11(4): 041110, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16965138

RESUMO

A setup based on color Schlieren techniques has been developed to study the interaction of energy sources, such as lasers, with biological tissues. This imaging technique enables real-time visualization of dynamic temperature gradients with high spatial and temporal resolution within a transparent tissue model. High-speed imaging techniques were combined in the setup to capture mechanical phenomena such as explosive vapor, cavitation bubbles, and shock waves. The imaging technique is especially used for qualitative studies because it is complex to obtain quantitative data by relating the colors in the images to temperatures. By positioning thermocouples in the field of view, temperature figures can be added in the image for correlation to colored areas induced by the temperature gradients. The color Schlieren setup was successfully used for various studies to obtain a better understanding of interaction of various laser, rf, and ultrasound devices used in medicine. The results contributed to the safety and the optimal settings of various medical treatments. Although the interaction of energy sources is simulated in model tissue, the video clips have proven to be of great value for educating researchers, surgeons, nurses, and students to obtain a better understanding of the mechanism of action during patient treatment.


Assuntos
Diagnóstico por Imagem/instrumentação , Terapia a Laser/educação , Terapia a Laser/instrumentação , Modelos Biológicos , Óptica e Fotônica/instrumentação , Imagens de Fantasmas , Pesquisa/instrumentação , Fenômenos Biomecânicos , Temperatura Corporal/fisiologia , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos
7.
J Endourol ; 30(6): 685-91, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26886510

RESUMO

OBJECTIVES: To evaluate the ex vivo accuracy of an MRI-TRUS fusion device for guiding targeted prostate biopsies, to identify the origin of errors, and to evaluate the likelihood that lesions can be accurately targeted. MATERIALS AND METHODS: Three prostate phantoms were used to perform 27 biopsies using transperineal MRI-TRUS fusion. All phantoms underwent 3-T MRI. The prostate contour and nine lesions were delineated onto the MRI. A 3D-US dataset was generated and fused with the MRI. Per lesion, one needle was virtually planned. The postbiopsy needle location was virtually registered. The needle trajectory was marked using an MRI-safe guidewire. Postinterventional MRI was performed. The coordinates of the lesion on preinterventional MRI, the virtually planned needle, the virtually registered needle, and the marked needle trajectory on postinterventional MRI were documented and used to calculate the planning error (PE), targeting error (TE), and overall error (OE). Using the OE in the transversal plane, an upper one-sided tolerance interval was calculated to assess the likelihood that a biopsy needle was on target. RESULTS: In the transversal plane, the mean PE, TE, and OE were 1.18, 0.39, and 2.33 mm, respectively. Using a single biopsy core, the likelihood that lesions with a diameter of 2 mm can be accurately targeted is 26%; lesions of 3 mm 61%; lesions of 4 mm 86%; lesions of 5 mm 96%; and lesions of 6 mm 99%. The likelihood of accurate sampling increases if more biopsy cores are used. CONCLUSION: MRI-TRUS fusion allows for accurate sampling of MRI-identified lesions with an OE of 2.33 mm. Lesions with a diameter of 3 mm or more can be accurately targeted. These results should be considered the lower limit of in vivo accuracy.


Assuntos
Biópsia com Agulha de Grande Calibre/métodos , Biópsia/métodos , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Ultrassonografia , Humanos , Masculino , Peritônio , Imagens de Fantasmas , Neoplasias da Próstata/cirurgia , Reprodutibilidade dos Testes
8.
Eur Urol ; 57(4): 655-60, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19819064

RESUMO

BACKGROUND: Photodynamic diagnosis (PDD) is a technique that enhances the detection of occult bladder tumors during cystoscopy using a fluorescent dye. OBJECTIVE: To study the differential effects of bacillus Calmette-Guérin (BCG) and mitomycin C (MMC) intravesical therapy on the false-positive rate of PDD of bladder cancer. DESIGN, SETTING, AND PARTICIPANTS: This study included 552 procedures and 1874 biopsies. INTERVENTION: Tumors were resected and biopsies were taken from suspicious areas, under guidance of white-light endoscopy and 5-ALA (5-aminolevulinic acid)-induced fluorescence cystoscopy. MEASUREMENTS: The influence of intravesical BCG immunotherapy and intravesical MMC chemotherapy on pyuria, inflammation, and PDD specificity was examined in univariate analyses. RESULTS AND LIMITATIONS: BCG significantly results in inflammation (odds ratio [OR]: 1.53, p=0.002), leukocyturia (OR: 1.84, p=0.034), and false positives in PDD (OR: 1.49, p=0.001). However, a single BCG instillation within 3 mo before PDD is most likely not associated with increased false-positive rates (OR: 0.35, p=0.26). Leukocyturia normalizes within 6 wk after the last BCG instillation, but PDD specificity is reduced up to 3 mo. CONCLUSIONS: BCG is an important predictor for false positives in PDD (5-ALA). More than one BCG instillation within 3 mo before fluorescence cystoscopy decreases the specificity of PDD.


Assuntos
Ácido Aminolevulínico , Antibióticos Antineoplásicos/administração & dosagem , Vacina BCG/administração & dosagem , Carcinoma de Células de Transição/diagnóstico , Carcinoma de Células de Transição/terapia , Cistoscopia , Mitomicina/administração & dosagem , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/terapia , Administração Intravesical , Antibióticos Antineoplásicos/efeitos adversos , Vacina BCG/efeitos adversos , Biópsia , Carcinoma de Células de Transição/patologia , Reações Falso-Positivas , Feminino , Humanos , Inflamação/induzido quimicamente , Contagem de Leucócitos , Modelos Logísticos , Masculino , Mitomicina/efeitos adversos , Estadiamento de Neoplasias , Países Baixos , Razão de Chances , Valor Preditivo dos Testes , Piúria/induzido quimicamente , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Fatores de Tempo , Resultado do Tratamento , Neoplasias da Bexiga Urinária/patologia , Urina/citologia
9.
Vet Surg ; 34(4): 353-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16212590

RESUMO

OBJECTIVE: To compare use of neodymium:yttrium aluminum garnet (Nd:YAG) surgical laser and bipolar electrocoagulation (BEC) for laparoscopic ovariectomy (OVE) in dogs. STUDY DESIGN: Prospective clinical trial. ANIMALS: Female dogs (n=72). METHODS: Laparoscopic OVE by Nd:YAG laser (600 microm optical fiber, contact mode) in 36 dogs was compared with laparoscopic OVE by bipolar electro-coagulating grasping forceps. Dogs were paired (laser, electrocoagulation) matched for breed, age, body weight, obesity, and number of heat cycles. Duration of predetermined surgery times and total surgical time were compared between groups. Occurrence of intra- and postoperative complications and their effect on surgical duration were evaluated. RESULTS: Laser surgery resulted in a higher incidence of intraoperative mesovarial bleeding (12 times; 9 dogs) compared with electrosurgery (4 times; 3 dogs). Use of laser caused a 2 minute delay for transection of the left ovary compared with electrosurgery. Postoperative complication rates and convalescence were similar for both groups. CONCLUSIONS: BEC reduced surgical time and intraoperative mesovarial bleeding compared with laser resection. CLINICAL RELEVANCE: Although the laser was effective for laparoscopic OVE, bipolar electrosurgical laparoscopic OVE remained the method of choice.


Assuntos
Cães/cirurgia , Eletrocoagulação/veterinária , Terapia a Laser/veterinária , Ovariectomia/veterinária , Animais , Eletrocoagulação/métodos , Feminino , Hemorragia/epidemiologia , Hemorragia/veterinária , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/veterinária , Laparoscopia/métodos , Laparoscopia/veterinária , Terapia a Laser/métodos , Ovariectomia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/veterinária , Estudos Prospectivos , Distribuição Aleatória , Fatores de Tempo
10.
Urology ; 63(5): 882-6, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15134971

RESUMO

OBJECTIVES: To compare the costs of transurethral resection of the prostate (TURP), contact laser prostatectomy (CLP), and electrovaporization in men with lower urinary tract symptoms associated with benign prostatic hyperplasia. METHODS: We conducted a randomized controlled trial that included men with lower urinary tract symptoms who met the criteria of the International Scientific Committee on benign prostatic hyperplasia. Subjective changes were quantified using questionnaires validated by the American Urological Association. The maximal free urinary flow rate was estimated. Morbidity and mortality were registered. These parameters were measured at regular intervals for up to 1 year and once during long-term follow-up. A cost analysis together with a sensitivity analysis was performed on the basis of a follow-up of 12 months. RESULTS: A total of 50 men were randomized to TURP, 45 to laser treatment, and 46 to electrovaporization. The subjective and objective changes were very similar during the 12 months of follow-up. The costs were highest for CLP (1885 dollars), followed by TURP (1707 dollars), and were lowest for electrovaporization (1489 dollars). However, the length of hospital stay decreased during the trial more for CLP and electrovaporization than for TURP. Recalculations demonstrated almost equal costs for CLP and TURP (1697 dollars and 1643 dollars, respectively) and the lowest costs for electrovaporization (1386 dollars). CONCLUSIONS: Electrovaporization has a better cost-effectiveness than CLP and TURP in patients with lower urinary tract symptoms associated with benign prostatic hyperplasia. CLP and TURP showed very similar cost-effectiveness ratios.


Assuntos
Eletrocirurgia/economia , Terapia a Laser/economia , Prostatectomia/economia , Hiperplasia Prostática/cirurgia , Análise Custo-Benefício , Humanos , Masculino , Prostatectomia/métodos , Sensibilidade e Especificidade , Ressecção Transuretral da Próstata/economia , Ressecção Transuretral da Próstata/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA