Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Endoscopy ; 54(5): 488-495, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34293811

RESUMO

BACKGROUND: To optimize colonoscopy quality, several performance measures have been developed. These are usually assessed without distinction between the indications for colonoscopy. This study aimed to assess the feasibility of linking two national registries (one for colonoscopy and one for adverse events of gastrointestinal endoscopies in the Netherlands), and to describe the results of colonoscopy quality per indication. METHODS: This retrospective study was conducted with prospectively collected data of the Dutch Gastrointestinal Endoscopy Audit (DGEA) and the Dutch Registration of Complications in Endoscopy (DRCE). Data between 01-01-2016 and 01-01-2019 were analyzed. To calculate adverse event rates, data were linked at the level of endoscopy service. RESULTS: During the 3-year study period, 266 981 colonoscopies were recorded in DGEA. Of all indications, cecal intubation rate was highest in fecal immunochemical test (FIT)-positive screening colonoscopies (97.1 %), followed by surveillance (93.2 %), diagnostic (90.7 %), and therapeutic colonoscopies (83.1 %). The highest rate of adequate bowel preparation was observed in FIT-positive screening colonoscopies (97.1 %). A total of 1540 colonoscopy-related adverse events occurred (0.58 % of all colonoscopies). Bleeding and perforation and rates were highest for therapeutic (1.56 % and 0.51 %, respectively) and FIT-positive screening (0.72 % and 0.06 %, respectively) colonoscopies. The colonoscopy-related mortality was 0.006 %. CONCLUSION: This study describes the first results of the Dutch national colonoscopy registry, which was successfully linked to data from the national registry for adverse events of gastrointestinal endoscopies. In this large dataset, performance varied between indications. Our results emphasize the importance of defining benchmarks per indication in future guidelines.


Assuntos
Colonoscopia , Neoplasias Colorretais , Ceco , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Humanos , Países Baixos , Sistema de Registros , Estudos Retrospectivos
2.
Gastrointest Endosc ; 92(1): 154-162.e1, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32057727

RESUMO

BACKGROUND AND AIMS: The importance of having quality assessment, assurance, and improvement tools in health care is increasingly recognized. However, the additional associated administration burden progressively interferes with the structural implementation and adoption of such tools, especially when it concerns high-volume procedures such as colonoscopies. The development of the Dutch Gastrointestinal Endoscopy Audit (DGEA), a registry with automated extraction of colonoscopy quality data, and its first results are described. METHODS: In close cooperation with commercial endoscopy reporting systems and a national histopathology database, healthcare professionals performing colonoscopies initiated a quality registry that extracts data from its core hospital resource or histology database without manual interference of the healthcare providers. Data extracted consisted of patient age, gender, indication of the colonoscopy, American Society of Anesthesiologists score, Boston Bowel Preparation Score, and cecal intubation; for the colonoscopy after a positive fecal immunochemical test in the colorectal cancer screening program, other data were polyp detection rate, which was available for all 48 hospitals or endoscopy centers, and adenoma detection rate, which was available for 26 hospitals or endoscopy centers. RESULTS: Between January 1, 2016 and March 31, 2019, 48 hospitals or endoscopy centers voluntarily participated in the DGEA, and 275,017 unique patients with 313,511 colonoscopies were registered. Overall missing values were limited to <1%. CONCLUSIONS: The results of this study demonstrate that it is feasible to deploy a quality registry collecting uniform data without additional administration burden for healthcare professionals.


Assuntos
Neoplasias Colorretais , Adenoma , Ceco , Colonoscopia , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer , Humanos , Sangue Oculto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA