RESUMO
Macrophages are innate immune cells that prevent infections and help in wound healing and vascular inflammation. While these cells are natural helper cells, they also contribute to chronic diseases, e.g., by infiltrating the endothelial layer in early atherosclerosis and by promoting vascular inflammation. There is a crosstalk between inflammatory pathways and key players in thrombosis, such as platelets and endothelial cells - a phenomenon known as 'thromboinflammation'. The role of the embedded macrophages in thromboinflammation in the context of vascular disease is incompletely understood. Blood vessels-on-chips, which are microfluidic vascular cell culture models, have been used extensively to study aspects of vascular disease, like permeability, immune cell adhesion and thrombosis. Blood perfusion assays in blood vessel-on-chip models benefit from multiple unique aspects of the models, such as control of microvessel structure and well-defined flow patterns, as well as the ability to perform live imaging. However, due to their simplified nature, blood vessels-on-chip models have not yet been used to capture the complex cellular crosstalk that is important in thromboinflammation. Using induced pluripotent stem cell-derived endothelial cells and polarized THP-1 monocytes, we have developed and systematically set up a 3D blood vessel-on-chip with embedded (lipid-laden) macrophages, which is created using sequential cell seeding in viscous finger patterned collagen hydrogels. We have set up a human whole blood perfusion assay for these 3D blood vessels-on-chip. An increased deposition of fibrin in the blood vessel-on-chip models containing lipid-laden macrophages was observed. We anticipate the future use of this advanced vascular in vitro model in drug development for early atherosclerosis or aspects of other vascular diseases.
Assuntos
Aterosclerose , Trombose , Humanos , Células Endoteliais , Inflamação , Tromboinflamação , Macrófagos , LipídeosRESUMO
The blood-brain barrier (BBB) is a unique feature of the human body, preserving brain homeostasis and preventing toxic substances to enter the brain. However, in various neurodegenerative diseases, the function of the BBB is disturbed. Mechanisms of the breakdown of the BBB are incompletely understood and therefore a realistic model of the BBB is essential. We present here the smallest model of the BBB yet, using a microfluidic chip, and the immortalized human brain endothelial cell line hCMEC/D3. Barrier function is modulated both mechanically, by exposure to fluid shear stress, and biochemically, by stimulation with tumor necrosis factor alpha (TNF-α), in one single device. The device has integrated electrodes to analyze barrier tightness by measuring the transendothelial electrical resistance (TEER). We demonstrate that hCMEC/D3 cells could be cultured in the microfluidic device up to 7 days, and that these cultures showed comparable TEER values with the well-established Transwell assay, with an average (± SEM) of 36.9 Ω.cm(2) (± 0.9 Ω.cm(2)) and 28.2 Ω.cm(2) (± 1.3 Ω.cm(2)) respectively. Moreover, hCMEC/D3 cells on chip expressed the tight junction protein Zonula Occludens-1 (ZO-1) at day 4. Furthermore, shear stress positively influenced barrier tightness and increased TEER values with a factor 3, up to 120 Ω.cm(2). Subsequent addition of TNF-α decreased the TEER with a factor of 10, down to 12 Ω.cm(2). This realistic microfluidic platform of the BBB is very well suited to study barrier function in detail and evaluate drug passage to finally gain more insight into the treatment of neurodegenerative diseases.
Assuntos
Barreira Hematoencefálica/metabolismo , Fenômenos Mecânicos , Técnicas Analíticas Microfluídicas/instrumentação , Fenômenos Biomecânicos , Barreira Hematoencefálica/citologia , Linhagem Celular , Impedância Elétrica , Células Endoteliais/metabolismo , Humanos , Microscopia ConfocalRESUMO
In vitro neuronal models are essential for studying neurological physiology, disease mechanisms and potential treatments. Most in vitro models lack controlled vasculature, despite its necessity in brain physiology and disease. Organ-on-chip models offer microfluidic culture systems with dedicated micro-compartments for neurons and vascular cells. Such multi-cell type organs-on-chips can emulate neurovascular unit (NVU) physiology, however there is a lack of systematic data on how individual cell types are affected by culturing on microfluidic systems versus conventional culture plates. This information can provide perspective on initial findings of studies using organs-on-chip models, and further optimizes these models in terms of cellular maturity and neurovascular physiology. Here, we analysed the transcriptomic profiles of co-cultures of human induced pluripotent stem cell (hiPSC)-derived neurons and rat astrocytes, as well as one-day monocultures of human endothelial cells, cultured on microfluidic chips. For each cell type, large gene expression changes were observed when cultured on microfluidic chips compared to conventional culture plates. Endothelial cells showed decreased cell division, neurons and astrocytes exhibited increased cell adhesion, and neurons showed increased maturity when cultured on a microfluidic chip. Our results demonstrate that culturing NVU cell types on microfluidic chips changes their gene expression profiles, presumably due to distinct surface-to-volume ratios and substrate materials. These findings inform further NVU organ-on-chip model optimization and support their future application in disease studies and drug testing.
Assuntos
Astrócitos/metabolismo , Células Endoteliais da Veia Umbilical Humana/metabolismo , Células-Tronco Pluripotentes Induzidas/citologia , Microfluídica , Neurônios/metabolismo , Transcriptoma/genética , Animais , Adesão Celular/genética , Diferenciação Celular/genética , Células Cultivadas , Perfilação da Expressão Gênica , Regulação da Expressão Gênica , Ontologia Genética , Humanos , Neurônios/citologia , RatosRESUMO
Acceptance of microfluidic technology in everyday laboratory practice by biologists is still low. One of the reasons for this is that the technology combines poorly with standard cell biological and biochemical analysis tools. Flow cytometry is an example of a conventional analytical tool that is considered to be incompatible with microfluidic technology and its inherent small sample sizes. In this study, it is shown that properly designed microfluidic devices contain cell populations that are large enough to be analyzed by flow cytometry. To illustrate this, the uptake of fluorescent human low-density lipoprotein (LDL) by human endothelial cells that were cultured in a microfluidic channel was analyzed. It was found that the uptake of LDL by the cells increased linearly over time. Moreover, the uptake decreased when cells were pretreated with fluid shear stress inside the microfluidic devices. This study shows that microfluidic technology can be combined with conventional flow cytometry, while retaining the advantages of working with microfluidics such as low reagent use and dynamic cell culture conditions. This approach of combining microfluidic technology with conventional laboratory tools may contribute to greater acceptance of microfluidic devices in biological research.
Assuntos
Células Endoteliais/metabolismo , Citometria de Fluxo/métodos , Lipoproteínas LDL/metabolismo , Células Endoteliais/citologia , Humanos , Técnicas Analíticas Microfluídicas , Estresse MecânicoRESUMO
Organ-on-chip devices are intensively studied in academia and industry due to their high potential in pharmaceutical and biomedical applications. However, most of the existing organ-on-chip models focus on proof of concept of individual functional units without the possibility of testing multiple experimental stimuli in parallel. Here we developed a polydimethylsiloxane (PDMS) multiplexed chip with eight parallel channels branching from a common access port through which all eight channels can be addressed simultaneously without the need for extra pipetting steps thus increasing the reproducibility of the experimental results. At the same time, eight outlets provide individual entry to each channel with the opportunity to create eight different experimental conditions. A multiplexed chip can be assembled as a one-layer device for studying monocultures or as a two-layer device for studying barrier tissue functions. For a two-layer device, a â¼2 µm thick transparent PDMS membrane with 5 µm through-hole pores was fabricated in-house using a soft lithography technique, thereby allowing visual inspection of the cell-culture in real-time. The functionality of the chip was studied by recapitulating the blood-brain barrier. For this, human cerebral microvascular endothelial cells (hCMEC/D3) were cultured in mono- or coculture with human astrocytes. Immunostaining revealed a cellular monolayer with the expression of tight junction ZO-1 and adherence junction VE-cadherin proteins in endothelial cells as well as glial fibrillary acidic protein (GFAP) expression in astrocytes. Furthermore, multiplexed permeability studies of molecule passage through the cellular barrier exhibited expected high permeability coefficients for smaller molecules (4 kDa FITC-dextran) whereas larger molecules (20 kDa) crossed the barrier at a lower rate. With these results, we show that our device can be used as an organ-on-chip model for future multiplexed drug testing.
Assuntos
Barreira Hematoencefálica , Células Endoteliais , Técnicas de Cocultura , Humanos , Dispositivos Lab-On-A-Chip , Reprodutibilidade dos TestesRESUMO
Microfluidic systems enable automated and highly parallelized cell culture with low volumes and defined liquid dosing. To achieve this, systems typically integrate all functions into a single, monolithic device as a "one size fits all" solution. However, this approach limits the end users' (re)design flexibility and complicates the addition of new functions to the system. To address this challenge, we propose and demonstrate a modular and standardized plug-and-play fluidic circuit board (FCB) for operating microfluidic building blocks (MFBBs), whereby both the FCB and the MFBBs contain integrated valves. A single FCB can parallelize up to three MFBBs of the same design or operate MFBBs with entirely different architectures. The operation of the MFBBs through the FCB is fully automated and does not incur the cost of an extra external footprint. We use this modular platform to control three microfluidic large-scale integration (mLSI) MFBBs, each of which features 64 microchambers suitable for cell culturing with high spatiotemporal control. We show as a proof of principle that we can culture human umbilical vein endothelial cells (HUVECs) for multiple days in the chambers of this MFBB. Moreover, we also use the same FCB to control an MFBB for liquid dosing with a high dynamic range. Our results demonstrate that MFBBs with different designs can be controlled and combined on a single FCB. Our novel modular approach to operating an automated microfluidic system for parallelized cell culture will enable greater experimental flexibility and facilitate the cooperation of different chips from different labs.
RESUMO
Vascular cell biology is an area of research with great biomedical relevance. Vascular dysfunction is involved in major diseases such as atherosclerosis, diabetes, and cancer. However, when studying vascular cell biology in the laboratory, it is difficult to mimic the dynamic, three-dimensional microenvironment that is found in vivo. Microfluidic technology offers unique possibilities to overcome this difficulty. In this review, an overview of the recent applications of microfluidic technology in the field of vascular biological research will be given. Examples of how microfluidics can be used to generate shear stresses, growth factor gradients, cocultures, and migration assays will be provided. The use of microfluidic devices in studying three-dimensional models of vascular tissue will be discussed. It is concluded that microfluidic technology offers great possibilities to systematically study vascular cell biology with setups that more closely mimic the in vivo situation than those that are generated with conventional methods.
Assuntos
Vasos Sanguíneos/fisiologia , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Animais , Pesquisa Biomédica/instrumentação , Pesquisa Biomédica/métodos , Vasos Sanguíneos/citologia , Humanos , Doenças Vasculares/patologia , Doenças Vasculares/fisiopatologiaRESUMO
Pulmonary thrombosis is a significant cause of patient mortality; however, there are no effective in vitro models of thrombi formation in human lung microvessels that could also assess therapeutics and toxicology of antithrombotic drugs. Here, we show that a microfluidic lung alveolus-on-a-chip lined by human primary alveolar epithelium interfaced with endothelium and cultured under flowing whole blood can be used to perform quantitative analysis of organ-level contributions to inflammation-induced thrombosis. This microfluidic chip recapitulates in vivo responses, including platelet-endothelial dynamics and revealed that lipopolysaccharide (LPS) endotoxin indirectly stimulates intravascular thrombosis by activating the alveolar epithelium, rather than acting directly on endothelium. This model is also used to analyze inhibition of endothelial activation and thrombosis due to a protease activated receptor-1 (PAR-1) antagonist, demonstrating its ability to dissect complex responses and identify antithrombotic therapeutics. Thus, this methodology offers a new approach to study human pathophysiology of pulmonary thrombosis and advance drug development.
Assuntos
Barreira Alveolocapilar/efeitos dos fármacos , Desenvolvimento de Medicamentos/métodos , Descoberta de Drogas/métodos , Fibrinolíticos/farmacologia , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Microvasos/efeitos dos fármacos , Alvéolos Pulmonares/irrigação sanguínea , Trombose/tratamento farmacológico , Barreira Alveolocapilar/metabolismo , Barreira Alveolocapilar/patologia , Células Cultivadas , Técnicas de Cocultura , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo , Células Endoteliais/patologia , Células Epiteliais/efeitos dos fármacos , Células Epiteliais/metabolismo , Células Epiteliais/patologia , Medicina Baseada em Evidências/métodos , Humanos , Microvasos/metabolismo , Microvasos/patologia , Segurança do Paciente , Medição de Risco , Transdução de Sinais/efeitos dos fármacos , Trombose/metabolismo , Trombose/patologia , Pesquisa Translacional Biomédica/métodosRESUMO
Essentials Vessel stenosis due to large thrombus formation increases local shear 1-2 orders of magnitude. High shear at stenotic sites was exploited to trigger eptifibatide release from nanocapsules. Local delivery of eptifibatide prevented vessel occlusion without increased tail bleeding times. Local nanocapsule delivery of eptifibatide may be safer than systemic antiplatelet therapies. SUMMARY: Background Myocardial infarction and stroke remain the leading causes of mortality and morbidity. The major limitation of current antiplatelet therapy is that the effective concentrations are limited because of bleeding complications. Targeted delivery of antiplatelet drug to sites of thrombosis would overcome these limitations. Objectives Here, we have exploited a key biomechanical feature specific to thrombosis, i.e. significantly increased blood shear stress resulting from a reduction in the lumen of the vessel, to achieve site-directed delivery of the clinically used antiplatelet agent eptifibatide by using shear-sensitive phosphatidylcholine (PC)-based nanocapsules. Methods PC-based nanocapsules (2.8 × 1012 ) with high-dose encapsulated eptifibatide were introduced into microfluidic blood perfusion assays and into in vivo models of thrombosis and tail bleeding. Results Shear-triggered nanocapsule delivery of eptifibatide inhibited in vitro thrombus formation selectively under stenotic and high shear flow conditions above a shear rate of 1000 s-1 while leaving thrombus formation under physiologic shear rates unaffected. Thrombosis was effectively prevented in in vivo models of vessel wall damage. Importantly, mice infused with shear-sensitive antiplatelet nanocapsules did not show prolonged bleeding times. Conclusions Targeted delivery of eptifibatide by shear-sensitive nanocapsules offers site-specific antiplatelet potential, and may form a basis for developing more potent and safer antiplatelet drugs.
Assuntos
Arteriopatias Oclusivas/prevenção & controle , Sistemas de Liberação de Medicamentos/métodos , Fibrinolíticos/administração & dosagem , Nanocápsulas , Peptídeos/administração & dosagem , Inibidores da Agregação Plaquetária/administração & dosagem , Agregação Plaquetária/efeitos dos fármacos , Trombose/prevenção & controle , Animais , Arteriopatias Oclusivas/sangue , Arteriopatias Oclusivas/fisiopatologia , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Preparações de Ação Retardada , Modelos Animais de Doenças , Composição de Medicamentos , Eptifibatida , Fibrinolíticos/química , Fibrinolíticos/toxicidade , Hemorragia/induzido quimicamente , Camundongos Endogâmicos C57BL , Peptídeos/química , Peptídeos/toxicidade , Fosfatidilcolinas/química , Inibidores da Agregação Plaquetária/química , Inibidores da Agregação Plaquetária/toxicidade , Fluxo Sanguíneo Regional , Estresse Mecânico , Trombose/sangue , Trombose/fisiopatologiaRESUMO
The physiology of vascular endothelial cells is strongly affected by fluid shear stress on their surface. In this study, a microfluidic assay was employed to analyze the alignment of actin filaments in endothelial cells in response to shear stress. When cells were cultured in microfluidic channels and subjected to shear stress, the alignment of filaments in the channel direction was significantly higher than in static cultures. By adding inhibitory drugs, the roles of several signaling proteins in the process of alignment were determined. Thus, it is shown how microfluidic technology can be employed to provide a mechanistic insight into cell physiology.
RESUMO
Vascular endothelial cells form the inner lining of all blood vessels and play a central role in vessel physiology and disease. Endothelial cells are highly responsive to the mechanical stimulus of fluid shear stress that is exerted by blood flowing over their surface. In this study, the immediate micromechanical response of endothelial cells to physiological shear stress was characterized by tracking of ballistically injected, sub-micron, fluorescent particles. It was found that the mean squared displacement (MSD) of the particles decreases by a factor 1.5 within 10 min after the onset of shear stress. This decrease in particle motion is transient, since the MSD returns to control values within 15-30 min after the onset of shear. The immediate micromechanical stiffening is dependent on activation of the vascular endothelial growth factor receptor (VEGFR)-2, because inhibition of the receptor abrogates the micromechanical response. This work shows that the cytoskeleton is actively involved in the acute, functional response of endothelial cells to shear stress.
Assuntos
Células Endoteliais/metabolismo , Microesferas , Movimento (Física) , Estresse Mecânico , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/metabolismo , Actinas/metabolismo , Forma Celular , Células Cultivadas , Citoesqueleto/metabolismo , Células Endoteliais/citologia , Hemorreologia , Humanos , Injeções , Microfluídica , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/antagonistas & inibidoresRESUMO
Vascular endothelial cells have an extensive response to physiological levels of shear stress. There is evidence that the protein caveolin-1 is involved in the early phase of this response. In this study, caveolin-1 was downregulated in human endothelial cells by RNAi. When these cells were subjected to a shear stress of 15 dyn/cm(2) for 10 minutes, activation of Akt and ERK1/2 was significantly lower than in control cells. Moreover, activation of Akt and ERK1/2 in response to vascular endothelial growth factor was significantly lower in cells with low levels of caveolin-1. However, activation of integrin-mediated signaling during cell adhesion onto fibronectin was not hampered by lowered caveolin-1 levels. In conclusion, caveolin-1 is an essential component in the response of endothelial cells to shear stress. Furthermore, the results suggest that the role of caveolin-1 in this process lies in facilitating efficient VEGFR2-mediated signaling.
RESUMO
1. The pharmacokinetics of R(+)-bupivacaine and S(-)-bupivacaine were investigated following a 10 min intravenous infusion of the racemate (dose 30 mg) in 10 healthy males. 2. The fractions unbound of R(+)- and S(-)-bupivacaine in pre-dose plasma were determined for each subject after in vitro addition of rac-bupivacaine (concentration of each enantiomer: approximately 300 ng ml-1). 3. The total plasma clearance of R(+)-bupivacaine (mean +/- s.d.: 0.395 +/- 0.076 l min-1) was greater (P < 0.0001) than that of S(-)-bupivacaine (0.317 +/- 0.067 l min-1). The volumes of distribution of R(+)-bupivacaine at steady state (84 +/- 29 l) and during the terminal log-linear phase (117 +/- 47 l) were larger (P < 0.0002) than those of S(-)-bupivacaine (54 +/- 20 l and 71 +/- 34 l, respectively). The terminal half-life (210 +/- 95 min) and mean residence time (215 +/- 74 min) of R(+)-bupivacaine were longer than those of S(-)-bupivacaine (157 +/- 77 min, P < 0.01, and 172 +/- 55 min, P < 0.02, respectively). 4. The free percentage of R(+)-bupivacaine (6.6 +/- 3.0 %) was greater (P < 0.0002) than that of S(-)-bupivacaine (4.5 +/- 2.1 %). 5. The plasma clearance of unbound R(+)-bupivacaine (7.26 +/- 3.60 1 min-1) was smaller (P < 0.01) than that of S(-)-bupivacaine (8.71 +/- 4.27 l min-1). Volumes of distribution based on unbound R(+)-bupivacaine concentrations (Vuss: 1576 +/- 934 l; Vu: 2233 +/- 1442 l) did not differ from those of S(-)-bupivacaine (Vuss: 1498 +/- 892 l; Vu: 1978 +/- 1302 l). 6. The enantioselective systemic disposition of bupivacaine can to a large extent be attributed to differences in the degree of plasma binding of the enantiomers.
Assuntos
Bupivacaína/farmacocinética , Adulto , Análise de Variância , Proteínas Sanguíneas/metabolismo , Coleta de Amostras Sanguíneas , Bupivacaína/administração & dosagem , Bupivacaína/sangue , Bupivacaína/química , Humanos , Infusões Intravenosas , Masculino , Ligação Proteica , EstereoisomerismoRESUMO
BACKGROUND: Prilocaine exists in two stereoisomeric configurations, the enantiomers S(+)- and R(-)-prilocaine. The drug is clinically used as the racemate. This study examined the pharmacokinetics of the enantiomers after intravenous administration of the racemate. METHODS: Ten healthy male volunteers received 200 mg racemic prilocaine as a 10-min intravenous infusion. Blood samples were collected for 8 h after the start of the infusion. Plasma concentrations were measured by stereoselective high-performance liquid chromatography (HPLC). Unbound fractions of the enantiomers in blank blood samples, spiked with racemic prilocaine, were determined using equilibrium dialysis. RESULTS: The unbound fraction of R(-)-prilocaine (mean +/- SD, 70%+/-8%) was smaller (P < 0.05) than that of S(+)-prilocaine (73%+/-5%). The total plasma clearance of R(-)-prilocaine (2.57+/-0.46 l/min) was larger (P < 0.0001) than that of S(+)-prilocaine (1.91+/-0.30 l/min). The steady-state volume of distribution of R(-)-prilocaine (279+/-94 l) did not differ from that of S(+)-prilocaine (291+/-93 l). The terminal half-life of R(-)-prilocaine (87+/-27 min) was shorter (P < 0.05) than that of S(+)-prilocaine (124+/-64 min), as was the mean residence time of R(-)-prilocaine (108+/-30 min) compared with S(+)-prilocaine (155+/-59 min; P < 0.005). CONCLUSIONS: The pharmacokinetics of prilocaine are enantioselective. The difference in clearance is most likely a result of a difference in intrinsic metabolic clearance. The difference in the pharmacokinetics of the enantiomers of prilocaine does not seem to be clinically relevant.
Assuntos
Anestésicos Locais/farmacocinética , Prilocaína/farmacocinética , Adulto , Humanos , Infusões Intravenosas , Masculino , Prilocaína/administração & dosagem , EstereoisomerismoRESUMO
From September 1983 to December 1985 40 patients from a total of 55 with periampullary and pancreatic head carcinoma underwent resectional surgery in our department. Following a policy of precise evaluation of each patient's operative findings, six patients underwent a Whipple duodenopancreatectomy, 29 patients underwent regional subtotal pancreatectomy, and five underwent regional total pancreatectomy. Five patients underwent vascular reconstruction of their regional vascular structures after transection of the invaded segments of their vessels and eight had positive lymph nodes. Lymph node involvement was confined to the regional area. Patients with distant lymph node involvement (paraaortic) were not considered eligible to resection. Three patients died and 10 required reoperation. Thirty-one had radical resection, one palliative and eight equivocal resection. From the survived patients (n = 37) 33 are alive and doing well at the time of this report (overall mean survival 18 months). The results of this study demonstrate that a radical approach based on a precise evaluation of operative findings of the individual patient might well offer a higher resectability rate and is probably the only chance for radical resection and for a longer survival in patients with periampullary and pancreatic head carcinoma.