Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
J Fish Biol ; 97(2): 537-545, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32447773

RESUMO

This study investigated the impact of the third dimension in geometric morphometrics (GM) using sailfin silversides (Telmatherinidae) from the Malili Lakes of Sulawesi (Indonesia). The three morphospecies of the monophyletic "roundfin" radiation are laterally compressed and vary in shape traits. The results of 2D and 3D GM were compared and quantified to discuss the advantages and disadvantages of both methods for closely related species and their sexes. This approach focused on the head because it is far more complex and three-dimensionally structured than the trunk or the caudal region. The results revealed no significant benefit concerning repeatability and measurement error in 3D GM compared to 2D GM. The z-axis contributed substantially to the variance of the 3D data set but was irrelevant for discrimination of species and sexes in the approach. Limited gain in information was contrasted by substantially higher effort for 3D compared to the 2D analyses. The study concluded that 2D GM is the more efficient shape analysis approach for discriminating roundfins. Broader studies are needed to test which of the two methods is more efficient in distinguishing laterally compressed fishes in general. For future studies, due to the high investment required, this study recommends carefully evaluating the necessity of 3D GM. If in doubt, this study suggests testing for congruence between 2D and 3D GM with a subsample and consequently applying 2D GM in the case of high congruence.


Assuntos
Peixes/anatomia & histologia , Imageamento Tridimensional/veterinária , Animais , Humanos , Indonésia , Modelos Anatômicos , Especificidade da Espécie
2.
Molecules ; 25(2)2020 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-31936633

RESUMO

Due to rigorous new environmental legislations, automotive, marine, aerospace, and construction sectors have redirected their focus into using more recyclable, sustainable, and environmentally friendly lightweight materials driven by strengthening resource efficiency drive. In this study, the influence of moisture absorption on flax and flax/glass hybrid laminates is presented with the aim to investigating their low velocity impact behaviour. Three different types of composite laminates namely, flax fibre reinforced vinyl ester, flax fibre hybridised glass fibre and glass fibre reinforced vinyl ester composites were fabricated using resin infusion technique. The moisture immersion tests were undertaken by immersing the different specimens in sea water bath at room temperature and 70 °C at different time durations. The low velocity falling weight impact testing was performed at 25 Joules of incident energy level and impact damage behaviour was evaluated at both ageing conditions using scanning electron microscopy (SEM) and X-ray microcomputed tomography (micro CT). The percentage of moisture uptake was decreased for flax vinyl ester specimens with glass fibre hybridisation. The maximum percentage of weight gain for flax fibre, flax/glass hybrid and glass fibre reinforced composites immersed at room temperature for 696 h is recorded at 3.97%, 1.93%, and 0.431%, respectively. The hybrid composite exhibited higher load and energy when compared flax/vinyl ester composite without hybridisation, indicating the hybrid system as a valid strategy towards achieving improved structural performance of natural fibre composites. The moisture absorption behaviour of these composites at room was observed to follow Fickian behaviour.


Assuntos
Ésteres/química , Linho/química , Cloreto de Polivinila/química , Água/química , Vidro/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Resistência à Tração , Têxteis/análise , Microtomografia por Raio-X
3.
AAPS PharmSciTech ; 20(5): 207, 2019 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-31161397

RESUMO

The use of inkjet printing for pharmaceutical manufacturing is gaining interest for production of personalized dosage forms tailored to specific patients. As part of the manufacturing, it is imperative to ensure that the correct dose is printed. The aim of this study was to use inkjet printing for manufacturing of personalized dosage forms combined with the use of near-infrared (NIR) and Raman spectroscopy as complementary analytical techniques for active pharmaceutical ingredient (API) quantification of the inkjet-printed dosage forms. Three APIs, propranolol (0.5-4.1 mg), montelukast (2.1-12.1 mg), and haloperidol (0.6-4.1 mg) were inkjet printed in 1 cm2 areas on a porous substrate. The printed doses were non-destructively analyzed by transmission NIR and Raman spectroscopy (both transmission and backscatter). X-ray computed microtomography (µ-CT) analysis was undertaken for porosity measurements of the substrate. The API content was confirmed using high-performance liquid chromatography (HPLC), and the content in the dosage forms was modeled from the NIR and Raman spectra using partial least squares regression (PLS). HPLC analysis revealed a linear correlation of the number of layers printed to the API content. The resulting PLS models for both NIR and Raman had R2 values between 0.95 and 0.99. The best predictive model was obtained using NIR, followed by Raman spectroscopy. µ-CT revealed the substrate to be highly porous and optimal for inkjet printing. In conclusion, NIR and Raman spectroscopic techniques could be used complementary as fast API quantification tools for inkjet-printed medicines.


Assuntos
Preparações Farmacêuticas/química , Impressão Tridimensional , Análise Espectral Raman/métodos , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Análise dos Mínimos Quadrados , Preparações Farmacêuticas/análise , Porosidade , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Microtomografia por Raio-X/métodos
4.
J Microsc ; 272(1): 35-46, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29984831

RESUMO

We show that attenuation X-ray microcomputed tomography (µ-CT) offers a route to extract the three-dimensional pore space of paper reliably enough to distinguish samples of the same kind of paper. Here, we consider two sack kraft papers for cement bags with different basis weights and thicknesses. Sample areas of approximately 5 mm2 with a resolution of 1.5 µm are considered, i.e. sizes that exceed sample areas of 2 mm2 for which the pore structure was previously studied in the literature. The image segmentation is based on indicator kriging as a local method that removes ambiguities in assigning voxels as pore or as fibre. The microstructures of the two samples are statistically compared in terms of descriptors such as sheet thickness, porosity, fractions of externally accessible pores and mean geodesic tortuosity. We demonstrate that a quantitative comparison of samples in terms of porosity and thickness requires a common definition of the sheet surfaces. Finally, the statistical pore space analysis based on the µ-CT scans reliably reveals structural differences between the two paper samples, but only when several descriptors are used. LAY DESCRIPTION: This paper is a seemingly abundant material. Its intrinsic porosity enables a vast number of commercial applications. Particularly packing products, e.g. cement bags, often incorporate sack kraft paper due to its high porosity and its additional mechanical strength. A direct quantification of the porosity of sack kraft papers is, hence, particularly desirable. However, experimental quantification of paper porosity or its pore network properties is difficult and often highly indirect. A nondestructive statistical analysis of the 3D microstructure holds the promise to directly assess the pores. In particular, X-ray microcomputed tomography (µ-CT), frequently with sub-µm resolution, has been established as a method to study the fibre and pore structure of paper. The question arises, whether statistical analysis of the microstructure based on µ-CT imaging is sufficient to reliably distinguish between different sack kraft papers. Here, we explore whether the pore structure of paper can be extracted and statistically analysed for larger sample areas despite the fact that a larger sample size directly translates into a lower resolution of the µ-CT scan. We expect that a large sample size increases the region of interest on the basis of which samples can be better distinguished. A lowered resolution poses a severe challenge for the reliable identification of voxel data as pores or as fibres, because the contrast between paper fibres (made of cellulose) and air, which is established due to X-ray absorption, is weak. We show that we can reliably assign each voxel by using an indicator kriging as a two-step method. This method performs an initial voxel identification based on the overall distribution of measured grey values and refines the identification by inspecting the local environment of each voxel. For the pore space extracted in such a way, we can then compute quantities that are related to the geometry and connectivity properties of the pores. Furthermore, we address a paper-born challenge for such an analysis, i.e. we cannot always unambiguously tell whether a pore is located inside the paper sheet or at the surface of the paper. The way the paper surfaces are extracted from the microstructure decisively determines the final specifications of the predicted properties. A significant distinction of the samples is only possible when comparing the properties of the pore network.

5.
J Microsc ; 268(2): 193-207, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28686286

RESUMO

We reconstruct the 3-D microstructure of centimetre-sized olivine crystals in rocks from the Almirez ultramafic massif (SE Spain) using combined X-ray micro computed tomography (µ-CT) and electron backscatter diffraction (EBSD). The semidestructive sample treatment involves geographically oriented drill pressing of rocks and preparation of oriented thin sections for EBSD from the µ-CT scanned cores. The µ-CT results show that the mean intercept length (MIL) analyses provide reliable information on the shape preferred orientation (SPO) of texturally different olivine groups. We show that statistical interpretation of crystal preferred orientation (CPO) and SPO of olivine becomes feasible because the highest densities of the distribution of main olivine crystal axes from EBSD are aligned with the three axes of the 3-D ellipsoid calculated from the MIL analyses from µ-CT. From EBSD data we distinguish multiple CPO groups and by locating the thin sections within the µ-CT volume, we assign SPO to the corresponding olivine crystal aggregates, which confirm the results of statistical comparison. We demonstrate that the limitations of both methods (i.e. no crystal orientation data in µ-CT and no spatial information in EBSD) can be overcome, and the 3-D orientation of the crystallographic axes of olivines from different orientation groups can be successfully correlated with the crystal shapes of representative olivine grains. Through this approach one can establish the link among geological structures, macrostructure, fabric and 3-D SPO-CPO relationship at the hand specimen scale even in complex, coarse-grained geomaterials.

6.
Eur J Oral Sci ; 124(3): 279-86, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27041355

RESUMO

The dynamic thermomechanical properties, sealing ability, and voids formation of an experimental obturation hydroxyapatite-reinforced polyethylene (HA/PE) composite/carrier system were investigated and compared with those of a commercial system [GuttaCore (GC)]. The HA/PE system was specifically designed using a melt-extrusion process. The viscoelastic properties of HA/PE were determined using a dynamic thermomechanical analyser. Human single-rooted teeth were endodontically instrumented and obturated using HA/PE or GC systems, and then sealing ability was assessed using a fluid filtration system. In addition, micro-computed tomography (µCT) was used to quantify apparent voids within the root-canal space. The data were statistically analysed using one-way anova and post hoc tests. The HA/PE composite exhibited important modulus and damping changes with an increase of temperature. The HA/PE system was more flexible than GC as the modulus of GC appeared to be significantly higher than that of HA/PE as a result of the high positive glass transition temperature (Tg ). However, HA/PE and GC presented similar sealing abilities. In conclusion, because sealing ability and voids formation were comparable between the tested materials, the experimental HA/PE system may be considered a suitable alternative material for root-canal obturation. Moreover, HA/PE possesses specific viscoelastic behaviour and lower melting points, which may facilitate root-canal retreatments.


Assuntos
Durapatita , Polietileno , Obturação do Canal Radicular , Microtomografia por Raio-X , Infiltração Dentária , Vidro , Humanos , Materiais Restauradores do Canal Radicular
7.
Chemosphere ; 362: 142709, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38936491

RESUMO

V-Ti magnetite tailings (VTMTs) contain various heavy metals, such as Fe, Mn, V, Co, and Ni. The groundwater pollution caused by the tailing metal release has become a local environmental concern. Although studies have demonstrated the influence of alternate flooding and drying cycles (FDCs) on metal form and mobility in minerals, little was known about whether FDCs affect the metal release of VTMTs and the transformation of released metals. This study investigated the metal release kinetics of VTMTs and the metal transformation under FDCs in the absence and presence of acid rain (sulfuric and nitric acids) and bio-secreted organic acids (acetic, oxalic, and citric acids). The results showed that FDCs promoted metal release whether or not acids were present. The maximum released concentrations of V, Mn, Fe, Co, and Ni were as high as 78.63 mg L-1,1.47 mg L-1, 67.96 µg L-1, 1.34 mg L-1, and 0.80 mg L-1, respectively, under FDCs and citric acids. FDCs enhanced the tailing metal release by increasing the metal labile fraction proportion. However, the concentrations of released Fe, Mn, V, Co, and Ni all gradually decreased due to their (co-)precipitation. These precipitates conversely inhibited the subsequent mineral dissolution by covering the tailing surface. FDCs also enhanced the tailings' porosities by 2.94%-9.94%. The mineral dissolution, expansion and shrinkage, and changes in tension destroyed the tailing microstructure during FDCs. This study demonstrated the low metal pollution risk of VTMTs under FDCs, either in acid rain or bio-secreted organic acids. However, the increase in tailing porosity should be seriously considered as it would affect the tailing pond safety.


Assuntos
Metais Pesados , Metais Pesados/análise , Óxido Ferroso-Férrico/química , Poluentes Químicos da Água/análise , Inundações , Água Subterrânea/química , Mineração , Dessecação , Chuva Ácida , Cinética
8.
Dent Mater ; 40(6): 930-940, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38724334

RESUMO

OBJECTIVES: An increasing number of CAD/CAM (computer-aided design/computer-aided manufacturing) hybrid materials have been introduced to the dental market in recent years. In addition, CAD/CAM hybrid materials for additive manufacturing (AM) are becoming more attractive in digital dentistry. Studies on material microstructures using micro-computed tomography (µ-CT) combined with scanning electron microscopy (SEM) have only been available to a limited extent so far. METHODS: One CAD/CAM three-dimensional- (3D-) printable hybrid material (VarseoSmile Crown plus) and two CAD/CAM millable hybrid materials (Vita Enamic; Voco Grandio), as well as one direct composite material (Ceram.x duo), were included in the present study. Cylindrical samples with a diameter of 2 mm were produced from each material and investigated by means of synchrotron radiation µ-CT at a voxel size of 0.65 µm. Different samples from the same materials, obtained by cutting and polishing, were investigated by SEM. RESULTS: The 3D-printed hybrid material showed some agglomerations and a more irregular distribution of fillers, as well as a visible layered macrostructure and a few spherical pores due to the printing process. The CAD/CAM millable hybrid materials revealed a more homogenous distribution of ceramic particles. The direct composite material showed multiple air bubbles and microstructural irregularities based on manual processing. SIGNIFICANCE: The µ-CT and SEM analysis of the materials revealed different microstructures even though they belong to the same class of materials. It could be shown that µ-CT and SEM imaging are valuable tools to understand microstructure and related mechanical properties of materials.


Assuntos
Desenho Assistido por Computador , Materiais Dentários , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Microtomografia por Raio-X , Materiais Dentários/química , Resinas Compostas/química , Impressão Tridimensional , Cerâmica/química
9.
Micron ; 164: 103375, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36334385

RESUMO

The objective of the present work is to review the main applications of X-ray microtomography in the microstructural study of mortars, based on a literature search related to the subject, and to enable the development of more innovative and sustainable mortar formulations. This three-dimensional non-destructive microscopy allows qualitative visualization down to micrometric scales, visualization of the spatial distribution of the interior of samples of objects relatively opaque to visible light and the measurement of quantitative microstructural parameters. Furthermore, the combination of X-ray microtomography with other microstructural and compositional techniques can result in data at different scales of observation. Particularly, in the study of mortars, there are benefits in using this technique to better characterize materials in terms of the spatial structure of pores and other voids, aiding in the formulation of new mortars and in the characterization of mortar behavior, for example, after leaching and carbonation processes. This paper intends to contribute to the discussion of the potentials and drawbacks of this advanced technique, allowing a better characterization of mortars and enabling the development of more innovative and sustainable formulations.

10.
Foods ; 12(22)2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-38002108

RESUMO

The impact of the ethylene inhibitor, 1-methylcyclopropene (1-MCP), on four apple cultivars (Braeburn, Fuji, Jazz and Golden Delicious) over 150 days of storage at 2 °C was assessed. Proton transfer reaction quadrupole mass spectrometry (PTR-QUAD-MS) was used to monitor changes in VOC composition, while texture analysis and X-ray microcomputer tomography (µ-CT) scanning were used to study microstructural changes. The application of 1-MCP on apples reduced VOC emissions, concurrently maintaining a firmer texture compared to the untreated apples at each time point. The µ-CT scanning revealed how changes in specific morphological characteristics such as anisotropy, connectivity and porosity, size and shape, as well as the interconnectivity of intracellular spaces (IS) influenced texture even when porosity was similar. Additionally, this study showed that the porosity and connectivity of IS were associated with VOC emission and increased simultaneously. This study highlights how the morphological parameters of an apple can help explain their ripening process during long-term storage and how their microstructure can influence the release of VOCs.

11.
J Biomech ; 147: 111434, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36638579

RESUMO

This study sought to 1) investigate the spatial distribution of mineral density of dog dentin using µ-CT and 2) characterize the relationship between the elastic modulus and mineral density of dog dentin using nanoindentation and µ-CT. Maxillary canine teeth of 10 mature dogs were scanned with a µ-CT then sectioned in the transverse and vertical planes and tested using nanoindentation. Spatial distribution of mineral density and elastic modulus was quantified. Results demonstrated significant spatial variation in mineral density and elastic modulus. Mineral density and elastic modulus generally increased from the dentin-pulp interface to the dentino-enamel junction and from the crown base to the crown tip. Significant site dependent correlations between mineral density and elastic modulus were determined (0.021 > R2 > 0.408). The results of this study suggest that while mineral density is a mediator of elastic modulus, other mediators such as collagen content may contribute to the mechanical behavior of dog dentin.


Assuntos
Dentina , Dente , Animais , Cães , Módulo de Elasticidade , Dentina/diagnóstico por imagem , Minerais , Tomografia Computadorizada por Raios X , Dureza
12.
Wellcome Open Res ; 8: 366, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37928208

RESUMO

Background: The University of Southampton, in collaboration with the University Hospital Southampton (UHS) NHS Foundation Trust and industrial partners, has been at the forefront of developing three-dimensional (3D) imaging workflows using X-ray microfocus computed tomography (µCT) -based technology. This article presents the outcomes of these endeavours and highlights the distinctive characteristics of a µCT facility tailored explicitly for 3D X-ray Histology, with a primary focus on applications in biomedical research and preclinical and clinical studies. Methods: The UHS houses a unique 3D X-ray Histology (XRH) facility, offering a range of services to national and international clients. The facility employs specialised µCT equipment explicitly designed for histology applications, allowing whole-block XRH imaging of formalin-fixed and paraffin-embedded tissue specimens. It also enables correlative imaging by combining µCT imaging with other microscopy techniques, such as immunohistochemistry (IHC) and serial block-face scanning electron microscopy, as well as data visualisation, image quantification, and bespoke analysis. Results: Over the past seven years, the XRH facility has successfully completed over 120 projects in collaboration with researchers from 60 affiliations, resulting in numerous published manuscripts and conference proceedings. The facility has streamlined the µCT imaging process, improving productivity and enabling efficient acquisition of 3D datasets. Discussion & Conclusions: The 3D X-ray Histology (XRH) facility at UHS is a pioneering platform in the field of histology and biomedical imaging. To the best of our knowledge, it stands out as the world's first dedicated XRH facility, encompassing every aspect of the imaging process, from user support to data generation, analysis, training, archiving, and metadata generation. This article serves as a comprehensive guide for establishing similar XRH facilities, covering key aspects of facility setup and operation. Researchers and institutions interested in developing state-of-the-art histology and imaging facilities can utilise this resource to explore new frontiers in their research and discoveries.

13.
ACS Biomater Sci Eng ; 9(12): 6773-6782, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37989264

RESUMO

Various types of microfabricated devices have been proposed for overcoming the gastrointestinal (GI) challenges associated with oral administration of pharmaceutical compounds. However, unidirectional drug release in very close forced proximity to the intestinal wall still appears to be an unresolved issue for many of these microdevices, which typically show low drug absorption and thereby low bioavailabilities. This work explores how recently developed and promising self-unfolding foils (SUFs) can be magnetically and/or radiopaquely (M/R-) functionalized, by the addition of BaSO4 or Fe3O4 nanoparticles, for improving their applicability within oral drug delivery. Through surface characterization, mechanical testing, and X-ray imaging, the (M/R-)SUFs are generally inspected and their overall properties compared. Furthermore, R-SUFs are being used in an in vivo rat X-ray imaging study, whereas in situ rat testing of MR-SUFs are attempted together with an investigation of their general magnetic properties. Unfolding of the R-SUF, and its very close forced proximity to the small intestine, is very easily observed 2 h post-administration by applying both computed tomography scanning and planar X-ray imaging. In addition, MR-SUFs show a great magnetic response in water, which suggests the possibility for controlled motion and retention in the GI tract. However, the magnetic response does not seem strong enough for in situ rat testing, but most likely a strong magnetization of the MR-SUFs using for example an impulse magnetizer can be made for increasing the magnetic response. All of the results presented herein are highly relevant and applicable for future usage of (M/R-)SUFs, as well as similar devices, in pre-clinical studies and potential clinical trials.


Assuntos
Fenômenos Magnéticos , Ratos , Animais , Preparações Farmacêuticas
14.
J Med Imaging (Bellingham) ; 10(5): 053501, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37753271

RESUMO

Purpose: Assessing the complex three-dimensional (3D) structure of the cochlea is crucial to understanding the fundamental aspects of signal transduction in the inner ear and is a prerequisite for the development of novel cochlear implants. X-ray phase-contrast computed tomography offers destruction-free 3D imaging with little sample preparation, thus preserving the delicate structure of the cochlea. The use of heavy metal stains enables higher contrast and resolution and facilitates segmentation of the cochlea. Approach: For µ-CT of small animal and human cochlea, we explore the heavy metal osmium tetroxide (OTO) as a radiocontrast agent and delineate laboratory µ-CT from synchrotron CT. We investigate how phase retrieval can be used to improve the image quality of the reconstructions, both for stained and unstained specimens. Results: Image contrast for soft tissue in an aqueous solution is insufficient under the in-house conditions, whereas the OTO stain increases contrast for lipid-rich tissue components, such as the myelin sheaths in nervous tissue, enabling contrast-based rendering of the different components of the auditory nervous system. The overall morphology of the cochlea with the three scalae and membranes is very well represented. Further, the image quality of the reconstructions improves significantly when a phase retrieval scheme is used, which is also suitable for non-ideal laboratory µ-CT settings. With highly brilliant synchrotron radiation (SR), we achieve high contrast for unstained whole cochleae at the cellular level. Conclusions: The OTO stain is suitable for 3D imaging of small animal and human cochlea with laboratory µ-CT, and relevant pathologies, such as a loss of sensory cells and neurons, can be visualized. With SR and optimized phase retrieval, the cellular level can be reached even for unstained samples in aqueous solution, as demonstrated by the high visibility of single hair cells and spiral ganglion neurons.

15.
Animals (Basel) ; 13(11)2023 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-37889740

RESUMO

Traditional methods for age determination of wildlife include either slicing thin sections off or grinding a tooth, both of which are laborious and invasive. Especially when it comes to ancient and valuable museum samples of rare or extinct species, non-invasive methods are preferable. In this study, X-ray micro-computed tomography (µ-CT) was verified as an alternative non-invasive method for age determination of three species within the order of Carnivora and suborders Odontoceti. Teeth from 13 red foxes (Vulpes vulpes), 2 American mink (Neogale vison), and 2 harbor porpoises (Phocoena phocoena) of known age were studied using µ-CT. The number of visible dental growth layers in the µ-CT were highly correlated with true age for all three species (R2 = 96%, p < 0.001). In addition, the Bland-Altman plot showed high agreement between the age of individuals and visible dental layers represented in 2D slices of the 3D µ-CT images. The true age of individuals was on average 0.3 (±0.6 SD) years higher than the age interpreted by the µ-CT image, and there was a 95% agreement between the true age and the age interpreted from visible dental layers in the µ-CT.

16.
ACS Biomater Sci Eng ; 8(10): 4236-4248, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36153956

RESUMO

Magnesium is projected for use as a degradable orthopedic biomaterial. However, its fast degradation in physiological media is considered as a significant challenge for its successful clinical applications. Bioactive reinforcements containing Mg-based composites constitute one of the promising approaches for developing degradable metallic implants because of their adjustable mechanical behaviors, corrosion resistance, and biological response. Strontium is a trace element known for its role in enhancing osteoblast activity. In this study, bioactive SrO-doped magnesium phosphate (MgP)-reinforced Mg composites containing 1, 3, and 5 wt % MgP were developed through the casting route. The influence of the SrO-doped MgP reinforcement on degradation behaviors of the composites along with its cell-material interactions and in vivo biocompatibility was investigated. The wt % and distribution of MgP particles significantly improved the mechanical properties of the composite. HBSS immersion study indicated the least corrosion rate (0.56 ± 0.038 mmpy) for the Mg-3MgP composite. The higher corrosion resistance of Mg-3MgP leads to a controlled release of Sr-containing bioactive reinforcement, which eventually enhanced the cytotoxicity as measured using MG-63 cell-material interactions. The in vivo biocompatibility of the composite was evaluated using the rabbit femur defect model. Micro-computed tomography (µ-CT) and histological analysis supported the fact that Mg-3MgP maintained its structural integrity and enhanced osteogenesis (50.36 ± 2.03%) after 2 months of implantation. The results indicated that the Mg-MgP composite could be used as a degradable internal fracture fixation device material.


Assuntos
Magnésio , Oligoelementos , Ligas , Animais , Materiais Biocompatíveis/farmacologia , Preparações de Ação Retardada , Magnésio/farmacologia , Compostos de Magnésio , Teste de Materiais , Fosfatos , Coelhos , Estrôncio/farmacologia , Microtomografia por Raio-X
17.
Front Bioeng Biotechnol ; 10: 862395, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35782504

RESUMO

In oral- and maxillofacial bone augmentation surgery, non-vascularized grafts from the iliac crest demonstrate better clinical performance than alveolar bone grafts. The underlying mechanisms are not fully understood but are essential for the enhancement of bone regeneration scaffolds. Synchrotron Radiation µ-CT at a pixel size of 2.3 µm was used to characterize the gross morphology and the vascular and osteocyte lacuna porosity of patient-matched iliac crest/alveolar bone samples. The results suggest a difference in the spatial distribution of the vascular pore system. Fluid simulations reveal the permeability tensor to be more homogeneous in the iliac crest, indicating a more unidirectional fluid flow in alveolar bone. The average distance between bone mineral and the closest vessel pore boundary was found to be higher in alveolar bone. At the same time, osteocyte lacunae density is higher in alveolar bone, potentially compensating for the longer average distance between the bone mineral and vessel pores. The present study comprehensively quantified and compared the 3D microarchitecture of intraindividual human alveolar and iliac bone. The identified difference in pore network architecture may allow a bone graft from the iliac crest to exhibit higher regeneration potential due to an increased capacity to connect with the surrounding pore network of the residual bone. The results may contribute to understanding the difference in clinical performance when used as bone grafts and are essential for optimization of future scaffold materials.

18.
Placenta ; 127: 88-94, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36030631

RESUMO

INTRODUCTION: Syngnathids (seahorses, pipefishes and seadragons) are among the few vertebrates that display male pregnancy. During seahorse pregnancy, males incubate developing embryos embedded in a placenta within a fleshy brood pouch, before expelling fully developed neonates at parturition. The mechanisms underpinning seahorse parturition are poorly understood. METHODS: We examined the morphology of the brood pouch using microcomputed tomography and histological techniques, in combination with physiological assays, to examine how male pot-bellied seahorses (Hippocampus abdominalis) control labour. In female-pregnant vertebrates, nonapeptide hormones (such as vasopressin- and oxytocin-like hormones) produce contractions of gestational smooth muscle to produce labour. RESULTS: Histological analysis of the seahorse brood pouch reveals only scattered small smooth muscle bundles in the brood pouch, and in-vitro application of isotocin (a teleost nonapeptide hormone) to the brood pouch do not produce measurable muscle contractions. Micro-computed tomography shows differences in size and orientation of the anal fin assembly between male and female pot-bellied seahorses, and histological analysis reveals large skeletal muscle bundles attached to the anal fin bones at the male brood pouch opening. DISCUSSION: We conclude that seahorse parturition may be facilitated by contraction of these muscles, which, in combination with body movements, serves to gape open the pouch and expel the neonates. Future biomechanical studies are needed to test this hypothesis.


Assuntos
Smegmamorpha , Animais , Parto Obstétrico , Feminino , Hormônios , Humanos , Recém-Nascido , Masculino , Parto , Gravidez , Smegmamorpha/anatomia & histologia , Smegmamorpha/fisiologia , Microtomografia por Raio-X
19.
Materials (Basel) ; 15(14)2022 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-35888222

RESUMO

The fracture behavior of the Cu/Sn-3.0Ag-0.5Sn (SAC305)/Cu solder joint was investigated by conducting tensile tests with in situ X-ray micro-computed tomography (µ-CT) observation, and finite element (FE) simulation. The tensile fracture process of solder joints with a real internal defect structure was simulated and compared with the experimental results in terms of defect distribution and fracture path. Additionally, the stress distribution around the defects during the tensile process was calculated. The experimental results reveal that the pores near the intermetallic compound (IMC) layers and the flaky cracks inside the solder significantly affected the crack path. The aggregation degree of the spherical pores and the angle between the crack surface and the loading direction controlled the initiation position and propagation path of the cracks. The fracture morphology indicates that the fracture of the IMC layer was brittle, while the solder fracture exhibited ductile tearing. There are significant differences in the fracture morphology under tensile and shear loading.

20.
Adv Sci (Weinh) ; 9(20): e2200458, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35567337

RESUMO

The opening and closing of pine cones is based on the hygroscopic behavior of the individual seed scales around the cone axis, which bend passively in response to changes in environmental humidity. Although prior studies suggest a bilayer architecture consisting of lower actuating (swellable) sclereid and upper restrictive (non- or lesser swellable) sclerenchymatous fiber tissue layers to be the structural basis of this behavior, the exact mechanism of how humidity changes are translated into global movement are still unclear. Here, the mechanical and hydraulic properties of each structural component of the scale are investigated to get a holistic picture of their functional interplay. Measurements of the wetting behavior, water uptake, and mechanical measurements are used to analyze the influence of hydration on the different tissues of the cone scales. Furthermore, their dimensional changes during actuation are measured by comparative micro-computed tomography (µ-CT) investigations of dry and wet scales, which are corroborated and extended by 3D-digital image correlation-based displacement and strain analyses, biomechanical testing of actuation force, and finite element simulations. Altogether, a model allowing a detailed mechanistic understanding of pine cone actuation is developed, which is a prime concept generator for the development of biomimetic hygromorphic systems.


Assuntos
Fenômenos Mecânicos , Cone de Plantas , Sementes/fisiologia , Molhabilidade , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA