Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Endocr Pract ; 30(3): 239-245, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38122932

RESUMO

OBJECTIVE: To investigate the usefulness of ultrasound (US) for the localization of ectopic hyperparathyroidism and compare it with 99mTc-sestamibi (99mTc-MIBI), 4-dimensional computed tomography (4D-CT), and 11C-choline positron emission tomography/ computed tomography (PET/CT). METHODS: Of the 527 patients with surgically confirmed primary hyperparathyroidism, 79 patients with ectopic hyperparathyroidism were enrolled. The diagnostic performance of US, 99mTc-MIBI, US + MIBI, 4D-CT, and 11C-choline PET/CT was calculated, and the factors affecting the sensitivity of US and 99mTc-MIBI were analyzed. RESULTS: Eighty-three ectopic parathyroid lesions were found in 79 patients. The sensitivity was 75.9%, 81.7%, 95.1%, 83.3%, and 100% for US, 99mTc-MIBI, US + MIBI, 4D-CT, and 11C-choline PET/CT, respectively. The difference in sensitivity among these different modalities did not achieve statistical significance (P > .05). The US sensitivity was significantly higher for ectopic lesions in the neck region than for those in the anterior mediastinum/chest wall (85.9% vs. 42.1%, P < .001). The 99mTc-MIBI and 4D-CT sensitivity was not significantly different between these two groups (84.1% vs. 94.6%, P = .193 and 81.3% vs. 85.7%, P = 1). The 11C-choline PET/CT sensitivity was 100% in both groups. CONCLUSIONS: US is a valuable tool for the localization of ectopic hyperparathyroidism, especially for ectopic lesions in the neck region.


Assuntos
Hiperparatireoidismo Primário , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia Computadorizada Quadridimensional/métodos , Hiperparatireoidismo Primário/diagnóstico por imagem , Colina , Tecnécio Tc 99m Sestamibi , Glândulas Paratireoides/diagnóstico por imagem , Compostos Radiofarmacêuticos
2.
J Endocrinol Invest ; 47(10): 2383-2396, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38837101

RESUMO

BACKGROUND: In recent years, nuclear medicine imaging methods have proven to be of paramount importance in a wide variety of diseases, particularly in oncology, where they are crucial for assessing the extent of disease when conventional methods fall short. Moreover, nuclear imaging modalities are able to better characterize lesions using target agents related to specific pathways (e.g. glucose metabolism, cellular proliferation, amino acid transport, lipid metabolism, specific receptor ligands). The clinical presentation of endocrine diseases encompasses a broad spectrum of sign and symptoms. Moreover, endocrine tumors show varying degrees of aggressiveness from well differentiated and indolent to highly aggressive cancers, respectively. RATIONALE: With the application of new medicinal radio-compounds and increasingly advanced tomographic imaging technology, the utility of Positron Emission Tomography/Computed Tomography (PET/CT) in the field of endocrine diseases is expanding. AIM: This review aims to analyze and summarize the primary indications of PET/CT, providing a practical approach for clinicians. A comprehensive literature search on PubMed was conducted to provide an updated overview of the available evidence regarding the use of PET/CT in endocrinology. Within this review, we will discuss the applications of PET/CT, compare different radiopharmaceuticals and highlight the uptake mechanism, excluding neuroendocrine carcinomas from discussion. CONCLUSIONS: PET/CT is a valuable tool in diagnosing and managing endocrine disorders due to its capacity to furnish both functional and anatomical information, facilitate early lesion detection, guide treatment decisions, and monitor treatment response. Its non-invasive nature and precision make it an integral component of modern endocrine healthcare. This review aims to provide physicians with a clear perspective on the role of PET/CT imaging, discussing its emerging opportunities and appropriateness of use in endocrinological diseases.


Assuntos
Doenças do Sistema Endócrino , Endocrinologia , Imagem Molecular , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Imagem Molecular/métodos , Imagem Molecular/tendências , Endocrinologia/métodos , Endocrinologia/tendências , Doenças do Sistema Endócrino/diagnóstico por imagem , Compostos Radiofarmacêuticos
3.
Clin Endocrinol (Oxf) ; 97(3): 258-267, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35150160

RESUMO

OBJECTIVE: Preoperative location of hyperfunctioning parathyroid glands (HPGs) is vital when planning minimally invasive surgery in patients with primary hyperparathyroidism (PHPT). Dual-isotope subtraction scintigraphy with 99m Tc-MIBI/123 Iodide using SPECT/CT and planar pinhole imaging (Di-SPECT) has shown high sensitivity, but is challenged by high radiation dose, time consumption and cost. 11 C-Choline PET/CT (faster with a lower radiation dose) is non-inferior to Di-SPECT. We aim to clarify to what extent the two are interchangeable and how often there are discrepancies. DESIGN: This is a prospective, GCP-controlled cohort study. PATIENTS AND MEASUREMENTS: One hundred patients diagnosed with PHPT were included and underwent both imaging modalities before parathyroidectomy. Clinical implications of differences between imaging findings and negative imaging results were assessed. Surgical findings confirmed by biochemistry and pathology served as reference standard. RESULTS: Among the 90 patients cured by parathyroidectomy, sensitivity was 82% (95% confidence interval [CI]: 74%-88%) and 87% (95% CI: 79%-92%) for Choline PET and Di-SPECT, respectively, p = .88. In seven cases at least one imaging modality found no HPG. Of these, neither modality found any true HPGs and only two were cured by surgery. When a positive finding in one modality was incorrect, the alternative modality was correct in approximately half of the cases. CONCLUSION: Choline PET and Di-SPECT performed equally well and are both appropriate as first-line imaging modalities for preoperative imaging of PHPT. When the first-line modality fails to locate an HPG, additional preoperative imaging with the alternate modality offers no benefit. However, if parathyroidectomy is unsuccessful, additional imaging with the alternate modality has merit before repeat surgery.


Assuntos
Hiperparatireoidismo Primário , Tecnécio Tc 99m Sestamibi , Colina , Estudos de Coortes , Humanos , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/patologia , Hiperparatireoidismo Primário/cirurgia , Iodetos , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/patologia , Glândulas Paratireoides/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Prospectivos , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
AJR Am J Roentgenol ; 218(1): 141-150, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34346785

RESUMO

PET with targeted radiotracers has become integral to mapping the location and burden of recurrent disease in patients with biochemical recurrence (BCR) of prostate cancer (PCa). PET with 11C-choline is part of the National Comprehensive Cancer Network and European Association of Urology guidelines for evaluation of BCR. With advances in PET technology, increasing use of targeted radiotracers, and improved survival of patients with BCR because of novel therapeutics, atypical sites of metastases are being increasingly encountered, challenging the conventional view that prostate cancer rarely metastasizes beyond bones or lymph nodes. The purpose of this article is to describe such atypical metastases in the abdomen and pelvis on 11C-choline PET (including metastases to the liver, pancreas, genital tract, urinary tract, peritoneum, abdominal wall, and perineural spread) and to present multimodality imaging features and relevant imaging pitfalls. Given atypical metastases' inconsistent relationship with the serum PSA level and the nonspecific presenting symptoms, atypical metastases are often first detected on imaging. Awareness of their imaging features is important because their detection affects clinical management, patient counseling, prognosis, and clinical trial eligibility. Such awareness is particularly critical because the role of radiologists in the imaging and management of BCR will continue to increase given the expanding regulatory approvals of other targeted and theranostic radiotracers.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Radioisótopos de Carbono , Colina , Segunda Neoplasia Primária/diagnóstico por imagem , Neoplasias Pélvicas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/patologia , Cavidade Abdominal/diagnóstico por imagem , Neoplasias Abdominais/secundário , Humanos , Masculino , Imagem Multimodal , Neoplasias Pélvicas/secundário , Pelve/diagnóstico por imagem
5.
Langenbecks Arch Surg ; 407(8): 3661-3669, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35945299

RESUMO

PURPOSE: A successful focused surgical approach in primary hyperparathyroidism (pHPT) relies on accurate preoperative localization of the parathyroid adenoma (PA). Most often, ultrasound is followed by [99mTc]-sestamibi scintigraphy, but the value of this approach is disputed. Here, we evaluated the diagnostic approach in patients with surgically treated pHPT in our center with the aim to further refine preoperative diagnostic procedures. METHODS: A single-center retrospective analysis of patients with pHPT from 01/2005 to 08/2021 was carried out followed by evaluation of the preoperative imaging modalities to localize PA. The localization of the PA had to be confirmed intraoperatively by the fresh frozen section and significant dropping of the intraoperative parathyroid hormone (PTH) levels. RESULTS: From 658 patients diagnosed with pHPT, 30 patients were excluded from the analysis because of surgery for recurrent or persistent disease. Median age of patients was 58.0 (13-93) years and 71% were female. Neck ultrasound was carried out in 91.7% and localized a PA in 76.6%. In 23.4% (135/576) of the patients, preoperative neck ultrasound did not detect a PA. In this group, [99mTc]-sestamibi correctly identified PA in only 25.4% of patients. In contrast, in the same cohort, the use of [11C]-methionine or [11C]-choline PET resulted in the correct identification of PA in 79.4% of patients (OR 13.23; 95% CI 5.24-33.56). CONCLUSION: [11C]-Methionine or [11C]-choline PET/CT are superior second-line imaging methods to select patients for a focused surgical approach when previous ultrasound failed to identify PA.


Assuntos
Adenoma , Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adenoma/diagnóstico por imagem , Adenoma/cirurgia , Colina , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/cirurgia , Metionina , Hormônio Paratireóideo , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Cintilografia , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Tecnécio Tc 99m Sestamibi , Adolescente , Adulto Jovem , Adulto
6.
Int J Urol ; 29(9): 1072-1078, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35875967

RESUMO

OBJECTIVE: The utility of 11 C-choline positron emission tomography/computed tomography for determining treatment response as compared with prostate-specific antigen response and prognosis prediction in castration-resistant prostate cancer patients was investigated. METHODS: Eighty-four 11 C-choline-positron emission tomography/computed tomography scans before/after treatments with abiraterone (n = 12 patients), enzalutamide (n = 3), docetaxel (n = 9), cabazitaxel (n = 5), radiation therapy alone (n = 3), radiation therapy, enzalutamide, and/or abiraterone (n = 5), radium-223 (n = 4), and radiofrequency ablation (n = 1) in 42 castration-resistant prostate cancer patients were retrospectively examined. Prostate-specific antigen values were determined before and after treatment. Using the Kaplan-Meier method, the correlation of Positron Emission Tomography Response Criteria In Solid Tumors with prostate-specific antigen response and prognostic impact was evaluated. RESULTS: Pretreatment 11 C-choline-positron emission tomography/computed tomography findings identified local, lymph node, bone, and visceral metastasis in 12, 12, 29, and five patients, respectively. Following treatments, complete metabolic response was noted in one, partial metabolic response in eight, stable metabolic disease in 13, and progressive metabolic disease in 20. Mean prostate-specific antigen change for complete metabolic response, partial metabolic response, stable metabolic disease and progressive metabolic disease was -48.9%, -55.0% (range -92.4% to -19.1%), -4.2% (-33.2% to 35.1%), and 142.7% (30.7% to 373.8%), respectively, significantly greater in the progressive metabolic disease cases (P < 0.01). Positron Emission Tomography Response Criteria In Solid Tumors was well correlated with prostate-specific antigen change. Patients with no progression (complete metabolic response/partial metabolic response/stable metabolic disease) showed significantly longer cancer-specific survival than progressive metabolic disease (P < 0.005). Using pretreatment 11 C-choline-positron emission tomography/computed tomography results to divide into three groups; (a) local and/or lymph node metastasis without bone metastasis (n = 10), (b) <6 bone metastasis sites (n = 16), (c) ≥6 bone metastasis sites and/or visceral metastasis (n = 16), cancer-specific survival showed significant stratification (P < 0.001). CONCLUSIONS: 11 C-choline-positron emission tomography/computed tomography may reflect castration-resistant prostate cancer metastatic lesion activity for treatment response and prognosis evaluations.


Assuntos
Doenças Metabólicas , Neoplasias de Próstata Resistentes à Castração , Neoplasias da Próstata , Benzamidas , Radioisótopos de Carbono , Colina , Humanos , Masculino , Nitrilas , Feniltioidantoína , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Antígeno Prostático Específico , Neoplasias da Próstata/patologia , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/terapia , Estudos Retrospectivos
7.
Eur J Nucl Med Mol Imaging ; 46(4): 921-929, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30631911

RESUMO

PURPOSE: The main drawback of 11C-choline PET/CT for restaging prostate cancer (PCa) patients with biochemical failure is the relatively low positive detection rate for prostate specific antigen (PSA) < 1 ng/ml. This study assessed whether 11C-choline PET/CT predicts survival in PCa patients with PSA < 1 ng/ml. METHODS: This retrospective study included 210 PCa patients treated with radical prostatectomy who underwent 11C-choline PET/CT from December 1, 2004 to July 31, 2007 due to biochemical failure. PCa-specific survival was estimated using Kaplan-Meier curves. Cox regression analysis was used to evaluate the association between clinicopathologic variables and PCa-specific survival. PCa-specific survival was computed as the interval from radical prostatectomy to PCa-specific death. RESULTS: Median follow-up after radical prostatectomy was 6.9 years (95% confidence interval, CI, 2.0-14.5 years). 11C-choline PET/CT was positive in 20.5% of patients. Median PCa-specific survival was 13.4 years (95% CI, 9.9-16.8 years) in patients with positive 11C-choline PET/CT, and it was not achieved in patients with negative 11C-choline PET/CT (log-rank, chi-square = 15.0, P < 0.001). Ten-year survival probabilities for patients with negative 11C-choline PET/CT and for patients with positive 11C-choline PET/CT were 86.0% (95% CI: 80.7%-91.3%) and 63.6% (95% CI: 54.5-72.7%). At multivariate analysis, only 11C-choline PET/CT significantly predicted PCa-specific survival (hazard ratio = 2.54, 95% CI, 1.05-6.13, P = 0.038). Patients with pathological 11C-choline uptake in the prostatic bed or in pelvic lymph nodes had longer PCa-specific survival in comparison to patients with pathological tracer uptake in the skeleton (log-rank: chi-square = 27.4, P < 0.001). CONCLUSION: Despite the relatively low positive detection rate for PSA < 1 ng/ml, positive 11C-choline PET/CT predicts PCa-specific survival in this low PSA range. As long as more sensitive radiotracers, such as 68Ga-PSMA-11, do not become more widely available, these results might support a broader use of radiolabeled choline in restaging PCa for PSA < 1 ng/ml.


Assuntos
Radioisótopos de Carbono , Colina , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Antígeno Prostático Específico/metabolismo , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Prostatectomia , Neoplasias da Próstata/cirurgia , Análise de Sobrevida
8.
Acta Med Okayama ; 73(4): 341-347, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31439957

RESUMO

We investigated the effectiveness of 11C-choline-positron emission tomography/computed tomography (PET/CT) for evaluating treatment response in patients with prostate cancer or renal cell carcinoma. We performed 34 11C-choline PET/CT scans before/after a combined total of 17 courses of treatment in 6 patients with prostate cancer and 2 with renal cell carcinoma. The 17 treatments including hormonal therapy, radiotherapy, chemotherapy, radium-223, molecular target therapy, radiofrequency ablation, transcatheter arterial embolization, and cancer immunotherapy yielded 1 (5.9%) complete metabolic response (CMR), 3 (17.6%) partial metabolic responses (PMRs), 2 (11.8%) stable metabolic diseases (SMDs), and 11 (64.7%) progressive metabolic diseases (PMDs). Target lesions were observed in bone (n=14), lymph nodes (n=5), lung (n=2), prostate (n=2), and pleura (n=1), with CMR in 4, PMR in 10, SMD in 8 and PMD in 2 lesions. SUVmax values of the target lesions before and after treatment were 7.87±2.67 and 5.29±3.98, respectively, for a mean reduction of -35.4±43.6%. The response for the 8 prostate cancer-treatment courses was PMD, which correlated well with changes in serum prostatic specific antigen (PSA) (7 of 8 cases showed increased PSA). 11C-choline-PET/CT may be an effective tool for detecting viable residual tumors and evaluating treatment response in prostate cancer and renal cell carcinoma patients.


Assuntos
Carcinoma de Células Renais/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/terapia , Idoso , Radioisótopos de Carbono , Colina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia
9.
Eur J Nucl Med Mol Imaging ; 45(5): 751-758, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29192364

RESUMO

AIM: During our daily clinical practice using 11C-Choline PET/CT for restaging patients affected by relapsing prostate cancer (rPCa) we noticed an unusual but significant occurrence of hypodense hepatic lesions with a different tracer uptake. Thus, we decided to evaluate the possible correlation between rPCa and these lesions as possible hepatic metastases. MATERIALS AND METHODS: We retrospectively enrolled 542 patients diagnosed with rPCa in biochemical relapse after a radical treatment (surgery and/or radiotherapy). Among these, patients with a second tumor or other benign hepatic diseases were excluded. All patients underwent 11C-Choline PET/CT during the standard restaging workup of their disease. We analyzed CT images to evaluate the presence of hypodense lesions and PET images to identify the relative tracer uptake. In accordance to the subsequent oncological history, five clinical scenarios were recognized [Table 1]: normal low dose CT (ldCT) and normal tracer distribution (Group A); evidence of previously unknown hepatic round hypodense areas at ldCT with normal rim uptake (Group B); evidence of previously known hepatic round hypodense areas at ldCT stable over time and with normal rim uptake (Group C); evidence of previously known hepatic round hypodense areas at ldCT, in a previous PET/CT scan, with or without rim uptake and significantly changing over time in terms of size and/or uptake (Group D); evidence of hepatic round hypodense areas at ldCT with or without rim uptake confirmed as prostate liver metastases by histopathology, triple phase ceCT, ce-ultra sound (CEUS) and clinical/biochemical evaluation (Group E). We evaluated the correlation with PSA level at time of scan, rim SUVmax and association with local relapse or non-hepatic metastases (lymph nodes, bone, other parenchyma). RESULTS: Five hundred and forty-two consecutive patients were retrospectively enrolled. In 140 of the 542 patients more than one 11C-choline PET/CT had been performed. A total of 742 11C-Choline PET/CT scans were analyzed. Of the 542 patients enrolled, 456 (84.1%) had a normal appearance of the liver both at ldCT and PET (Group A). 19/542 (3,5%) belonged to Group B, 13/542 (2.4%) to Group C, 37/542 (6.8%) to Group D and 18/542 (3.3%) to Group E. Mean SUVmax of the rim was: 4.5 for Group B; 4.2 for Group C; 4.8 for Group D; 5.9 for Group E. Mean PSA level was 5.27 for Group A, 7.9 for Group B, 10.04 for Group C, 10.01 for Group D, 9.36 for Group E. Presence of positive findings at 11C-Choline PET/CT in any further anatomical area (local relapse, lymph node, bone, other extra hepatic sites) correlated with an higher PSA (p = 0.0285). In both the univariate and multivariate binary logistic regression analyses. PSA, SUVmax of the rim, local relapse, positive nodes were not associated to liver mets (Groups D-E) (p > 0.05). On the contrary, a significant correlation was found between the presence of liver metG (group D-E) and bone lesions (p= 0.00193). CONCLUSION: Our results indicate that liver metastases in relapsing prostate cancer may occur frequently. The real incidence evaluation needs more investigations. In this case and despite technical limitations, Choline PET/CT shows alterations of tracer distribution within the liver that could eventually be mistaken for simple cysts but can be suspected when associated to high trigger PSA, concomitant bone lesions or modification over time. In this clinical setting an accurate analysis of liver tracer distribution (increased or decreased uptake) by the nuclear medicine physician is, therefore, mandatory.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/patologia , Idoso , Idoso de 80 Anos ou mais , Radioisótopos de Carbono , Colina , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Tomografia por Emissão de Pósitrons , Antígeno Prostático Específico , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
10.
Eur J Nucl Med Mol Imaging ; 45(6): 962-969, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29453702

RESUMO

PURPOSE: Previous studies in prostate cancer (PCa) patients tried to correlate the onset of local recurrence (LR) with the development of distant metastases and formulated, based on theoretical and experimental data, hypotheses linking the two events. We aimed to address this issue with 11C-choline positron emission tomography/computed tomography (PET/CT). METHODS: This retrospective study included 491 PCa patients previously treated with radical prostatectomy who had undergone 11C-choline PET/CT owing to biochemical failure. Further inclusion criteria were availability of clinical and pathological variables for survival analysis. Statistical significance was taken at P < 0.05. RESULTS: Seventy-two patients (14.7%) had evidence of LR at 11C-choline PET/CT. The frequency of LR increased from 13.8% in the interval 0-4 years after prostatectomy, to 23.9% in the 12-16-year interval (P = 0.080). On the contrary, the frequency of lymph node metastases (overall rate in the 0-16 years interval after prostatectomy: 26.3%) and of bone metastases (overall rate: 13.8%) decreased significantly over time. Kaplan-Meier curves showed no significant group difference in the rates of lymph node or bone metastases between patients with LR and patients without LR. LR significantly predicted PCa-specific survival at univariate analysis, but the statistical significance was lost at multivariate analysis. CONCLUSION: We found no differences in the rates of lymph node and bone metastases between patients with and without LR. An inverse time-dependent trend was observed in the frequency of LR on one side and of lymph node and bone metastases on the other side. These findings were discussed in relation to previous theories linking LR to distant metastases and our study design.


Assuntos
Metástase Neoplásica/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Radioisótopos de Carbono , Colina , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Antígeno Prostático Específico , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
11.
Contemp Oncol (Pozn) ; 22(4): 260-265, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30783391

RESUMO

The importance of [11C]-choline as a PET/CT marker has been extensively described, although its production presents considerable technical difficulties. The main ones are short half-lives and the occurrence of dimethylformamide (DMF) as a residual solvent. While the losses resulting from the radionuclide decay can be minimised by shortening the duration of the process, the best solution for reducing the content of DMF is its elimination from the reaction environment. In the current work two methods are compared for [11C]-choline synthesis - a green chemistry approach (with ethanol as a green solvent) and a dry synthesis. The results were compared with each other and with those of the method based on DMF. The solid phase synthesis proved to be the most effective in total elimination of DMF, its final release was the highest, and the synthesis time was the shortest. The optimised synthesis led to the formation of the desired radiotracer with a high radiochemical yield (65% ±3%) in a short production time (12 min) and the residual precursor in the final product at the level of 1 µg/ml. 27% increase of the saturation yield was possible, which resulted in 9 GBq higher activity from 40 minutes of beaming. Each test batch passed all standard quality control requirements, and the levels of residual DMEA were below the limits that have been published in the last Pharmacopoeia monograph.

12.
Eur J Nucl Med Mol Imaging ; 44(10): 1751-1776, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28409220

RESUMO

We here aim to provide a comprehensive and critical review of the literature concerning the clinical applications of positron emission tomography/computed tomography (PET/CT) with radiolabeled choline in patients with prostate cancer (PCa). We will initially briefly summarize the historical context that brought to the synthesis of [11C]choline, which occurred exactly 20 years ago. We have arbitrarily grouped the clinical studies in three different periods, according to the year in which they were published and according to their relation with their applications in urology, radiotherapy and oncology. Studies at initial staging and, more extensively, studies in patients with biochemical failure, as well as factors predicting positive PET/CT will be reviewed. The capability of PET/CT with radiolabeled choline to provide prognostic information on PCa-specific survival will also be examined. The last sections will be devoted to the use of radiolabeled choline for monitoring the response to androgen deprivation therapy, radiotherapy, and chemotherapy. The accuracy and the limits of the technique will be discussed according to the information available from standard validation processes, including biopsy or histology. The clinical impact of the technique will be discussed on the basis of changes induced in the management of patients and in the evaluation of the response to therapy. Current indications to PET/CT, as officially endorsed by guidelines, or as routinely performed in the clinical practice will be illustrated. Emphasis will be made on methodological factors that might have influenced the results of the studies or their interpretation. Finally, we will briefly highlight the potential role of positron emission tomography/magnetic resonance and of new radiotracers for PCa imaging.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Colina , Humanos , Marcação por Isótopo , Masculino , Estadiamento de Neoplasias , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Neoplasias da Próstata/terapia , Resultado do Tratamento
13.
BJU Int ; 119(3): 406-413, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27104782

RESUMO

OBJECTIVE: To report the 3-year toxicity and outcomes of carbon 11 (11C)-choline-positron emission tomography (PET)/computed tomography (CT)-guided radiotherapy (RT), delivered via helical tomotherapy (HTT; Tomotherapy® Hi-Art II® Treatment System, Accuray Inc., Sunnyvale, CA, USA) after lymph node (LN) relapses in patients with prostate cancer. PATIENTS AND METHODS: From January 2005 to March 2013, 81 patients with biochemical recurrence after surgery, with or without adjuvant/salvage RT or radical RT, and with evidence of LN 11C-choline-PET/CT pathological uptake, underwent HTT (median [range] prostate-specific antigen level 2.59 [0.61-187] ng/mL). Of the 81 patients, 72 were treated at the pelvic and/or lumbar-aortic LN chain with HTT at 51.8 Gy/28 fr and with simultaneous integrated boost to a median dose of 65.5 Gy on the pathological uptake sites detected by 11C-choline-PET/CT. Nine patients were treated without simultaneous integrated boost (50-65.5 Gy, 25-30 fr). RESULTS: With a median (range) follow-up of 36 (9-116) months, 91.4% of the patients had a PSA reduction 3 months after HTT. The 3-year overall, local relapse-free and clinical relapse-free survival rates were 80.0, 89.8 and 61.8%, respectively. The 3-year actuarial incidences of ≥grade 2 rectal and ≥grade 2 genitourinary toxicity were 6.6% (±2.9%) and 26.3% (±5.5%), respectively. A PSA nadir of ≥0.26 ng/mL (hazard ratio [HR] 3.6, 95% confidence interval [CI] 1.7-7.7; P = 0.001), extrapelvic 11C-choline-PET/CT-positive LN location (HR 2.4, 95% CI 0.9-6.4; P = 0.07), RT previous to HTT (HR 2.7; 95% CI 1.07-6.9, P = 0.04) and number of positive LNs (HR 1.13, 95% CI 1.04-1.22; P = 0.003) were the main predictors of clinical relapse after HTT. CONCLUSIONS: 11C-choline-PET/CT-guided HTT is safe and effective in the treatment of LN relapses of prostate cancer in previously treated patients.


Assuntos
Colina/análogos & derivados , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Idoso , Idoso de 80 Anos ou mais , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Terapia de Salvação/métodos , Resultado do Tratamento
14.
Prostate ; 76(1): 3-12, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26390847

RESUMO

BACKGROUND: Index lesion characterization is important in the evaluation of primary prostate carcinoma (PPC). The aim of this study was to analyze the contribution of (11) C-Choline PET/CT and the Apparent Diffusion Coefficient maps (ADC) in detecting the Index Lesion and clinically significant tumors in PPC. METHODS: Twenty-one untreated patients with biopsy-proven PPC and candidates for radical prostatectomy (RP) were prospectively evaluated by means of Ultra-High Definition PET/CT and 3T MRI, which included T2-weighted imaging (T2WI) and ADC maps obtained from diffusion weighted imaging (DWI). Independent experts analyzed all the images separately and were unaware of the pathological data. In each case, the Index lesion was defined as the largest tumor measured on histopathology (Index H). In addition, the largest lesion observed on MRI (Index MRI) and the highest avid (11) C-Choline uptake lesion (Index PET) were obtained. The Gleason scores (GS) of the tumors were determined. PET/CT and ADC map quantitative parameters were also calculated. Measures of correlation among imaging parameters as well as the sensitivity (S), specificity (Sp), negative and positive predictive values (NPV and PPV) for tumor detection were analyzed. All data was validated with the pathological study. RESULTS: In the morphological study, 139 foci of carcinoma were identified, 47 of which corresponded to clinically significant tumors (>0.5 cm(3)). The remaining foci presented a maximum diameter (dmax ) of 0.1 cm ± SD 0.75 and were not classified as clinically significant. Thirty-two tumors presented a GS (3 + 3), nine GS (3 + 4), and six GS (4 + 3). A total of 21 Index H (dmax = 1.37 cm SD ± 0.61) were identified. The S, Sp, NPV, and PPV for tumor detection with PET were 100%, 70%, 83%, 100%, and for MRI were 46%, 100%, 100%, 54%, respectively. Both Index PET and Index MRI were complementary and identified 95% of the Index H when quantitative criteria were used. CONCLUSION: In spite of the fact that PET imaging has higher tumor sensitivity than MRI, (11) C-Choline PET and ADC maps have complementary roles in the evaluation of Index Lesion in PPC. Index PET and Index MRI could be complementary targets in the therapeutic planning of PPC.


Assuntos
Carcinoma/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Próstata/patologia , Neoplasias da Próstata/patologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Biópsia , Radioisótopos de Carbono/farmacologia , Colina/farmacologia , Pesquisa Comparativa da Efetividade , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Cuidados Pré-Operatórios/métodos , Compostos Radiofarmacêuticos/farmacologia , Sensibilidade e Especificidade , Carga Tumoral
15.
Tumour Biol ; 37(3): 2999-3007, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26415734

RESUMO

The early diagnosis of prostate cancer (PCa) appears to be of vital significance for the provision of appropriate treatment programs. Even though several sophisticated imaging techniques such as positron emission tomography/computed tomography (PET/CT) and elastosonography (ES) have already been developed for PCa diagnosis, the diagnostic accuracy of these imaging techniques is still controversial to some extent. Therefore, a comprehensive meta-analysis in this study was performed to compare the accuracy of various diagnostic imaging methods for PCa, including 11C-choline PET/CT, 11C-acetate PET/CT, 18F-fluorocholine PET/CT, 18F-fluoroglucose PET/CT, transrectal real-time elastosonography (TRTE), and shear-wave elastosonography (SWE). The eligible studies were identified through systematical searching for the literature in electronic databases including PubMed, Cochrane, and Web of Science. On the basis of the fixed-effects model, the pooled sensitivity (SEN), specificity (SPE), and area under the receiver operating characteristics curve (AUC) were calculated to estimate the diagnostic accuracy of 11C-choline PET/CT, 11C-acetate PET/CT, 18F-fluorocholine (FCH) PET/CT, 18F-fluoroglucose (FDG) PET/CT, TRTE, and SWE. All the statistical analyses were conducted with R language Software. The present meta-analysis incorporating a total of 82 studies demonstrated that the pooled sensitivity of the six imaging techniques were sorted as follows: SWE > 18F-FCH PET/CT > 11C-choline PET/CT > TRTE > 11C-acetate PET/CT > 18F-FDG PET/CT; the pooled specificity were also compared: SWE > 18F-FCH PET/CT > 11C-choline PET/CT > TRTE > 18F-FDG PET/CT > 11C-acetate PET/CT; finally, the pooled diagnostic accuracy of the six imaging techniques based on AUC were ranked as below: SWE > 18F-FCH PET/CT > 11C-choline PET/CT > TRTE > 11C-acetate PET/CT > 18F-FDG PET/CT. SWE and 18F-FCH PET/CT imaging could offer more assistance in the early diagnosis of PCa than any other studied imaging techniques. However, the diagnostic ranking of the six imaging techniques might not be applicable to the clinical phase due to the shortage of stratified analysis.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Colina/análogos & derivados , Fluordesoxiglucose F18 , Humanos , Masculino
16.
Eur J Nucl Med Mol Imaging ; 43(1): 55-69, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26450693

RESUMO

PURPOSE: For the last decade PET and PET/CT with (11)C-choline have been proposed for the evaluation of prostate cancer (PC), but the diagnostic performance of (11)C-choline PET/CT is still a matter of debate. We performed a comprehensive review of the most important clinical application of (11)C-choline PET, restaging of patients with biochemical relapse, following a rigorous methodological approach and including assessment of the risk of bias. We conducted a systematic review and meta-analysis of the literature assessing (11)C-choline PET/CT for its accuracy in the diagnosis and ability to detect the site of recurrence of PC in the restaging of patients with biochemical recurrence after initial treatment with curative intent. METHODS: We performed a comprehensive literature search of PubMed and the Cochrane Library to determine the accuracy for the detection of the site of recurrence (prostate bed recurrences, metastatic spread to locoregional pelvic lymph nodes or distant metastases). Only studies with a reference standard (for prostatic bed histopathology, for histopathology or biopsy of distant metastases or a composite reference standard with clinical follow-up of at least 12 months, correlative imaging and clinical data) were included. RESULTS: Overall 425 studies were retrieved, of which 43 were judged as potentially relevant and 29 with 2,686 participants were finally included. Of these 29 studies, 18 reported results for any relapse, All 18 studies, with a total of 2,126 participants, reported detection rates. The pooled rate was 62 % (95 % CI 53 - 71 %). Of the 18 studies, 12 with 1,270 participants reported useful data to derive sensitivity and specificity. The pooled sensitivity was 89 % (95 % CI 83 - 93 %) and the pooled specificity was 89 % (95 % CI 73 - 96 %). Of 11 studies reporting results for local relapse, 9 with 993 participants reported detection rates. The pooled rate was 27 % (95 % CI 16 - 38 %). Six studies with 491 participants reported sensitivity and specificity. The pooled sensitivity was 61 % (95 % CI 40 - 80 %) and the pooled specificity was 97 % (95 % CI 87 - 99 %). Ten studies reported results for lymph nodes and distant metastases. For nodal disease, 7 studies with 752 participants reported detection rates. The pooled rate was 36 % (95 % CI 22 - 50 %). For bone metastases, 8 studies with 775 participants reported detection rates. The pooled rate was 25 % (95 % CI 16 - 34 %). CONCLUSION: There is a significant amount of (11)C-choline PET data published showing a high degree of consistency in inclusion criteria, acquisition protocols and scan interpretation criteria. Furthermore, the quality of the data derived limited to the same standard of reference was acceptable. Despite a high variability in the observed prevalence of any relapse, the diagnostic performance of (11)C-choline PET was in line with previous meta-analyses. Our data confirm the very good accuracy of (11)C-choline PET for detection of lymph node metastases and/or distant lesions in a single examination in patients with biochemical relapse.


Assuntos
Radioisótopos de Carbono , Colina , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/metabolismo , Tomografia Computadorizada por Raios X/métodos , Humanos , Masculino , Neoplasias da Próstata/patologia , Recidiva
17.
Eur J Nucl Med Mol Imaging ; 43(5): 852-859, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26577938

RESUMO

PURPOSE: In this prospective study, our goal was to emphasize the diagnostic value of combining (11)C-choline and (18)F-FDG PET/CT for hepatocellular carcinoma (HCC) in patients with chronic liver disease. METHODS: Thirty-three consecutive patients were enrolled. All patients were suspected to have HCC based on CT and/or MRI imaging. A final diagnosis was obtained by histopathological examination or by imaging alone according to American Association for the Study of Liver Disease criteria. All patients underwent PET/CT with both tracers within a median of 5 days. All lesions showing higher tracer uptake than normal liver were considered positive for HCC. We examined how tracer uptake was related to biological (serum α-fetoprotein levels) and pathological (differentiation status, peritumoral capsule and vascular invasion) prognostic markers of HCC, as well as clinical observations at 6 months (recurrence and death). RESULTS: Twenty-eight HCC, four cholangiocarcinomas and one adenoma were diagnosed. In the HCC patients, the sensitivity of (11)C-choline, (18)F-FDG and combined (11)C-choline and (18)F-FDG PET/CT for the detection of HCC was 75 %, 36 % and 93 %, respectively. Serum α-fetoprotein levels >200 ng/ml were more frequent among patients with (18)F-FDG-positive lesions than those with (18)F-FDG-negative lesions (p < 0.05). Early recurrence (n=2) or early death (n=5) occurred more frequently in patients with (18)F-FDG-positive lesions than in those with (18)F-FDG-negative lesions (p < 0.05). CONCLUSION: The combined use of (11)C-choline and (18)F-FDG PET/CT detected HCC with high sensitivity. This approach appears to be of potential prognostic value and may facilitate the selection of patients for surgical resection or liver transplantation.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Fluordesoxiglucose F18/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Radioisótopos de Carbono/administração & dosagem , Colina/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
18.
Eur J Nucl Med Mol Imaging ; 43(9): 1601-10, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26960562

RESUMO

PURPOSE: To compare the accuracy of (18)F-FACBC and (11)C-choline PET/CT in patients radically treated for prostate cancer presenting with biochemical relapse. METHODS: This prospective study enrolled 100 consecutive patients radically treated for prostate cancer and presenting with rising PSA. Of these 100 patients, 89 were included in the analysis. All had biochemical relapse after radical prostatectomy (at least 3 months previously), had (11)C-choline and (18)F-FACBC PET/CT performed within 1 week and were off hormonal therapy at the time of the scans. The two tracers were compared directly in terms of overall positivity/negativity on both a per-patient basis and a per-site basis. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were calculated for both the tracers; follow-up at 1 year (including correlative imaging, PSA trend and pathology when available) was considered as the standard of reference. RESULTS: In 51 patients the results were negative and in 25 patients positive with both the tracers, in eight patients the results were positive with (18)F-FACBC but negative with (11)C-choline, and in five patients the results were positive with (11)C-choline but negative with (18)F-FACBC. Overall in 49 patients the results were false-negative (FN), in two true-negative, in 24 true-positive (TP) and in none false-positive (FP) with both tracers. In terms of discordances between the tracers: (1) in one patient, the result was FN with (11)C-choline but FP with (18)F-FACBC (lymph node), (2) in seven, FN with (11)C-choline but TP with (18)F-FACBC (lymph node in five, bone in one, local relapse in one), (3) in one, FP with (11)C-choline (lymph node) but TP with (18)F-FACBC (local relapse), (4) in two, FP with (11)C-choline (lymph nodes in one, local relapse in one) but FN with (18)F-FACBC, and (5) in three, TP with (11)C-choline (lymph nodes in two, bone in one) but FN with (18)F-FACBC. With (11)C-choline and (18)F-FACBC, sensitivities were 32 % and 37 %, specificities 40 % and 67 %, accuracies 32 % and 38 %, PPVs 90 % and 97 %, and NPVs 3 % and 4 %, respectively. Categorizing patients by PSA level (<1 ng/ml 28 patients, 1 - <2 ng/ml 28 patients, 2 - <3 ng/ml 11 patients, ≥3 ng/ml 22 patients), the number (percent) of patients with TP findings were generally higher with (18)F-FACBC than with (11)C-choline: six patients (21 %) and four patients (14 %), eight patients (29 %) and eight patients (29 %), five patients (45 %) and four patients (36 %), and 13 patients (59 %) and 11 patients (50 %), respectively. CONCLUSION: (18)F-FACBC can be considered an alternative tracer superior to (11)C-choline in the setting of patients with biochemical relapse after radical prostatectomy.


Assuntos
Radioisótopos de Carbono , Ácidos Carboxílicos , Colina , Ciclobutanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/secundário , Reações Falso-Negativas , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Antígeno Prostático Específico/metabolismo , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Recidiva
19.
Eur J Nucl Med Mol Imaging ; 43(11): 1971-9, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27277279

RESUMO

PURPOSE: To evaluate (11)C-choline PET/CT as a diagnostic tool for restaging prostate cancer (PCa), in a large, homogeneous and clinically relevant population of patients with biochemical recurrence (BCR) of PCa after primary therapy. The secondary aim was to assess the best timing for performing (11)C-choline PET/CT during BCR. METHODS: We retrospectively analysed 9,632 (11)C-choline PET/CT scans performed in our institution for restaging PCa from January 2007 to June 2015. The inclusion criteria were: (1) proven PCa radically treated with radical prostatectomy (RP) or with primary external beam radiotherapy (EBRT); (2) PSA serum values available; (3) proven BCR (PSA >0.2 ng/mL after RP or PSA >2 ng/mL above the nadir after primary EBRT with rising PSA levels). Finally, 3,203 patients with recurrent PCa matching all the inclusion criteria were retrospectively enrolled and 4,426 scans were analysed. RESULTS: Overall, 52.8 % of the (11)C-choline PET/CT scans (2,337/4,426) and 54.8 % of the patients (1,755/3,203) were positive. In 29.4 % of the scans, at least one distant finding was observed. The mean and median PSA values were, respectively, 4.9 and 2.1 ng/mL at the time of the scan (range 0.2 - 50 ng/mL). In our series, 995 scans were performed in patients with PSA levels between 1 and 2 ng/mL. In this subpopulation the positivity rate in the 995 scans was 44.7 %, with an incidence of distant findings of 19.2 % and an incidence of oligometastatic disease (one to three lesions) of 37.7 %. The absolute PSA value at the time of the scan and ongoing androgen deprivation therapy were associated with an increased probability of a positive (11)C-choline PET/CT scan (p < 0.0001). In the ROC analysis, a PSA value of 1.16 ng/mL was the optimal cut-off value. In patients with a PSA value <1.16 ng/mL, 26.8 % of 1,426 (11)C-choline PET/CT scans were positive, with oligometastatic disease in 84.7 % of positive scans. CONCLUSION: In a large cohort of patients, the feasibility of (11)C-choline PET/CT for detecting the sites of metastatic disease in PCa patients with BCR was confirmed. The PSA level was the main predictor of a positive scan with 1.16 ng/mL as the optimal cut-off value. In the majority of positive scans oligometastatic disease, potentially treatable with salvage therapies, was observed.


Assuntos
Colina/análogos & derivados , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Estudos de Viabilidade , Humanos , Itália/epidemiologia , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/epidemiologia , Estadiamento de Neoplasias , Neoplasias da Próstata/epidemiologia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
20.
Rep Pract Oncol Radiother ; 20(2): 104-12, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25859399

RESUMO

AIM: To evaluate the influence of (11)C-choline PET/CT on radiotherapy planning in prostate cancer patients. BACKGROUND: Precise information on the extension of prostate cancer is crucial for the choice of an appropriate therapeutic strategy. (11)C-choline positron emission tomography ((11)C-choline PET/CT) has two roles in radiation oncology (RT): (1) patient selection for treatment and (2) target volume selection and delineation. In conjunction with high-accuracy techniques, it might offer an opportunity of dose escalation and better tumour control while sparing healthy tissues. MATERIALS AND METHODS: We carried out a retrospective study in order to analyse RT planning modification based on (11)C-choline PET/CT in 16 prostate cancer patients. Patients were treated with hypofractionated step-and-shoot Intensity Modulated Radiotherapy (IMRT), or Volumetric Modulated Arc Therapy (VMAT), and a daily cone-beam CT for Image Guided Radiation Therapy (IGRT). All patients underwent a (11)C-choline-PET/CT scan prior to radiotherapy. RESULTS: In 37.5% of cases, a re-delineation and new dose prescription occurred. Data show good preliminary clinical results in terms of biochemical control and toxicity. No gastrointestinal (GI)/genitourinary (GU) grade III toxicities were observed after a median follow-up of 9.5 months. CONCLUSIONS: In our experience, concerning the treatment of prostate cancer (PCa), (11)C-choline PET/CT may be helpful in radiotherapy planning, either for dose escalation or exclusion of selected sites.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA