Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
NMR Biomed ; 37(4): e5086, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38110293

RESUMO

Fluorine MRI is finding wider acceptance in theranostics applications where imaging of 19 F hotspots of fluorinated contrast material is central. The essence of such applications is to capture ghosting-artifact-free images of the inherently low MR response under clinically viable conditions. To serve this purpose, this work introduces the balanced spiral spectroscopic imaging (BaSSI) sequence, which is implemented on a 3.0 T clinical scanner and is capable of generating 19 F hotspot images in an efficient manner. The sequence utilizes an all-phase-encoded pseudo-spiral k-space trajectory, enabling the acquisition of broadband (80 ppm) fluorine spectra free from chemical shift ghosting. BaSSI can acquire a 64 × 64 image with 1 mm × 1 mm voxels in just 14 s, significantly outperforming typical MRSI sequences used in 1 H or 31 P imaging. The study employed in silico characterization to verify essential design choices such as the excitation pulse, as well as to identify the boundaries of the parameter space explored for optimization. BaSSI's performance was further benchmarked against the 3D ultrashort-echo-time balanced steady-state free precession (3D UTE BSSFP) sequence, a well established method used in 19 F MRI, in vitro. Both sequences underwent extensive optimization through exploration of a wide parameter space on a small phantom containing 10 µL of non-diluted bulk perfluorooctylbromide (PFOB) prior to comparative experiments. Subsequent to optimization, BaSSI and 3D UTE BSSFP were employed to capture images of small non-diluted bulk PFOB samples (0.10 and 0.05 µL), with variations in the number of signal averages, and thus the total scan time, in order to assess the detection sensitivities of the sequences. In these experiments, the detection sensitivity was evaluated using the Rose criterion (Rc ), which provides a quantitative metric for assessing object visibility. The study further demonstrated BaSSI's utility as a (pre)clinical tool through postmortem imaging of polymer microspheres filled with PFOB in a BALB/c mouse. Anatomic localization of 19 F hotspots was achieved by denoising raw data obtained with BaSSI using a filter based on the Rose criterion. These data were then successfully registered to 1 H anatomical images. BaSSI demonstrated superior detection sensitivity in the benchmarking analysis, achieving Rc values approximately twice as high as those obtained with the 3D UTE BSSFP method. The technique successfully facilitated imaging and precise localization of 19 F hotspots in postmortem experiments. However, it is important to highlight that imaging 10 mM PFOB in small mice postmortem, utilizing a 48 × 48 × 48 3D scan, demanded a substantial scan time of 1 h and 45 min. Further studies will explore accelerated imaging techniques, such as compressed sensing, to enhance BaSSI's clinical utility.


Assuntos
Fluorocarbonos , Hidrocarbonetos Bromados , Camundongos , Animais , Flúor , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos
2.
NMR Biomed ; 37(5): e5100, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38230415

RESUMO

Magnetic resonance imaging (MRI) is a routine diagnostic modality in oncology that produces excellent imaging resolution and tumor contrast without the use of ionizing radiation. However, improved contrast agents are still needed to further increase detection sensitivity and avoid toxicity/allergic reactions associated with paramagnetic metal contrast agents, which may be seen in a small percentage of the human population. Fluorine-19 (19F)-MRI is at the forefront of the developing MRI methodologies due to near-zero background signal, high natural abundance of 100%, and unambiguous signal specificity. In this study, we have developed a colloidal nanoemulsion (NE) formulation that can encapsulate high volumes of the fluorous MRI tracer, perfluoro-[15-crown-5]-ether (PFCE) (35% v/v). These nanoparticles exhibit long-term (at least 100 days) stability and high PFCE loading capacity in formulation with our semifluorinated triblock copolymer, M2F8H18. With sizes of approximately 200 nm, these NEs enable in vivo delivery and passive targeting to tumors. Our diagnostic formulation, M2F8H18/PFCE NE, yielded in vivo 19F-MR images with a high signal-to-noise ratio up to 100 in a tumor-bearing mouse model at clinically relevant scan times. M2F8H18/PFCE NE circulated stably in the vasculature, accumulated in high concentration of an estimated 4-9 × 1017 19F spins/voxel at the tumor site, and cleared from most organs over the span of 2 weeks. Uptake by the mononuclear phagocyte system to the liver and spleen was also observed, most likely due to particle size. These promising results suggest that M2F8H18/PFCE NE is a favorable 19F-MR diagnostic tracer for further development in oncological studies and potential clinical translation.


Assuntos
Imagem por Ressonância Magnética de Flúor-19 , Neoplasias , Camundongos , Humanos , Animais , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Razão Sinal-Ruído , Fígado
3.
J Nanobiotechnology ; 22(1): 180, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622591

RESUMO

To address the limitations of traditional photothermal therapy (PTT)/ photodynamic therapy (PDT) and real-time cancer metastasis detection, a pH-responsive nanoplatform (NP) with dual-modality imaging capability was rationally designed. Herein, 1 H,1 H-undecafluorohexylamine (PFC), served as both an oxygen carrier and a 19F magnetic resonance imaging (MRI) probe, and photosensitizer indocyanine green (ICG) were grafted onto the pH-responsive peptide hexahistidine (H6) to form H6-PFC-ICG (HPI). Subsequently, the heat shock protein 90 inhibitor, gambogic acid (GA), was incorporated into hyaluronic acid (HA) modified HPI (HHPI), yielding the ultimate HHPI@GA NPs. Upon self-assembly, HHPI@GA NPs passively accumulated in tumor tissues, facilitating oxygen release and HA-mediated cell uptake. Once phagocytosed by lysosomes, protonation of H6 was triggered due to the low pH, resulting in the release of GA. With near-infrared laser irradiation, GA-mediated decreased HSP90 expression and PFC-mediated increased ROS generation amplified the PTT/PDT effect of HHPI@GA, leading to excellent in vitro and in vivo anticancer efficacies. Additionally, the fluorescence and 19F MRI dual-imaging capabilities of HHPI@GA NPs enabled effective real-time primary cancer and lung metastasis monitoring. This work offers a novel approach for enhanced cancer phototherapy, as well as precise cancer diagnosis.


Assuntos
Neoplasias Pulmonares , Nanopartículas , Fotoquimioterapia , Humanos , Fototerapia/métodos , Verde de Indocianina , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Oxigênio , Concentração de Íons de Hidrogênio , Linhagem Celular Tumoral
4.
Nano Lett ; 23(24): 11989-11998, 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38064383

RESUMO

Due to their appealing physiochemical properties, metal-organic frameworks (MOFs) have been widely employed in biomedical fields. In this study, we utilize ferric ions and fluorine-containing organic ligands as both structural and functional units to develop a stimulus-responsive nanoagent, 19FIMOF-TA nanoparticles, for activatable 19F magnetic resonance imaging (MRI) and synergistic therapy of tumors. This nanoagent could respond to excess GSH in a tumor microenvironment, discharging fluorinated organic ligands and reduced ferrous ions. The release of these fluorine-containing small molecules results in boosting of the 19F MRI signals, which could be further enhanced by the photothermal effect of this nanoagent to achieve a responsive cascaded amplification of 19F MRI signals for tumor visualization. Meanwhile, ferroptosis promoted by the ferrous ions leads to significant tumor cell death, which is synergistically aggravated by the photothermal effect. The encouraging results illustrate the promising potential of our nanoagent for effective tumor imaging and combinative cancer therapy.


Assuntos
Estruturas Metalorgânicas , Nanopartículas , Neoplasias , Humanos , Estruturas Metalorgânicas/uso terapêutico , Estruturas Metalorgânicas/química , Flúor/química , Ferro , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Neoplasias/patologia , Nanopartículas/química , Íons , Linhagem Celular Tumoral , Microambiente Tumoral
5.
Nano Lett ; 23(7): 2964-2973, 2023 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-36947431

RESUMO

Recent advances in intratracheal delivery strategies have sparked considerable biomedical interest in developing this promising approach for lung cancer diagnosis and treatment. However, there are very few relevant studies on the behavior and mechanism of imaging nanoparticles (NPs) after intratracheal delivery. Here, we found that nanosized perfluoro-15-crown-5-ether (PFCE NPs, ∼200 nm) exhibite significant 19F-MRI signal-to-noise ratio (SNR) enhancement than perfluorooctyl bromide (PFOB NPs) up to day 7 after intratracheal delivery. Alveolar macrophages (AMs) engulf PFCE NPs, become PFCE NPs-laden AMs, and then migrate into the tumor margin, resulting in increased tumor PFCE concentration and 19F-MRI signals. AMs-mediated translocation of PFCE NPs to lung draning lymph nodes (dLNs) decreases the background PFCE concentration. Our results shed light on the dynamic AMs-mediated translocation of intratracheally delivered PFC NPs for effective lung tumor visualization and reveal a pathway to develop and promote the clinical translation of an intratracheal delivery-based imaging strategy.


Assuntos
Fluorocarbonos , Neoplasias Pulmonares , Nanopartículas , Humanos , Macrófagos Alveolares , Imageamento por Ressonância Magnética/métodos , Neoplasias Pulmonares/tratamento farmacológico
6.
Small ; 19(42): e2302621, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37340585

RESUMO

The clinical patency of small-diameter vascular grafts (SDVGs) (ID < 6 mm) is limited, with the formation of mural thrombi being a major threat of this limitation. Herein, a bilayered hydrogel tube based on the essential structure of native blood vessels is developed by optimizing the relation between vascular functions and the molecular structure of hydrogels. The inner layer of the SDVGs comprises a zwitterionic fluorinated hydrogel, avoiding the formation of thromboinflammation-induced mural thrombi. Furthermore, the position and morphology of the SDVGs can be visualized via 19 F/1 H magnetic resonance imaging. The outer poly(N-acryloyl glycinamide) hydrogel layer of SDVGs provides matched mechanical properties with native blood vessels through the multiple and controllable intermolecular hydrogen-bond interactions, which can withstand the accelerated fatigue test under pulsatile radial pressure for 380 million cycles (equal to a service life of 10 years in vivo). Consequently, the SDVGs exhibit higher patency (100%) and more stable morphology following porcine carotid artery transplantation for 9 months and rabbit carotid artery transplantation for 3 months. Therefore, such a bioinspired, antithrombotic, and visualizable SDVG presents a promising design approach for long-term patency products and great potential of helping patients with cardiovascular diseases.


Assuntos
Hidrogéis , Trombose , Humanos , Animais , Suínos , Coelhos , Inflamação , Prótese Vascular , Imageamento por Ressonância Magnética
7.
Chembiochem ; 24(19): e202300354, 2023 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-37345408

RESUMO

Capmatinib is an FDA-approved drug to treat metastatic non-small cell lung cancer with MET-exon 14 skipping. Herein, the perfluoro-tert-butyl group, which possesses nine chemically identical fluorine atoms, was introduced on Capmatinib to afford a targeted 19 F magnetic resonance imaging (MRI) probe, perfluoro-tert-butyl group-derived Capmatinib (9F-CAP). The 19 F MRI concentration limit was found to be 25 mM in FLASH sequence. Molecular docking simulation, surface plasmon resonance (SPR) (with a Kd of 40.7 µM), half-inhibitory concentration (with a IC50 of 168 nM), Annexin V, and cytotoxicity assays jointly demonstrated that the 9F-CAP targeted cMET protein specifically. Therefore, the targeted imaging capability of 9F-CAP is of great significance for the preoperative diagnosis of specific cancers.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/patologia , Simulação de Acoplamento Molecular , Imageamento por Ressonância Magnética
8.
Magn Reson Med ; 89(6): 2318-2331, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36744719

RESUMO

PURPOSE: To demonstrate the feasibility of using octafluorocyclobutane (OFCB, c-C4 F8 ) for T1 mapping of lungs in 19 F MRI. METHODS: The study was performed at 7 T in three healthy rats and three rats with pulmonary hypertension. To increase the sensitivity of 19 F MRI, a bent-shaped RF coil with periodic metal strips structure was used. The double flip angle method was used to calculate normalized transmitting RF field (B1n + ) maps and for correcting T1 maps built with the variable flip angle (VFA) method. The ultrashort TE pulse sequence was applied for acquiring MR images throughout the study. RESULTS: The dependencies of OFCB relaxation times on its partial pressure in mixtures with oxygen, air, helium, and argon were obtained. T1 of OFCB linearly depended on its partial pressure with the slope of about 0.35 ms/kPa in the case of free diffusion. RF field inhomogeneity leads to distortion of T1 maps built with the VFA method, and therefore to high standard deviation of T1 in these maps. To improve the accuracy of the T1 maps, the B1n + maps were applied for VFA correction. This contributed to a 2-3-fold decrease in the SD of T1 values in the corresponding maps compared with T1 maps calculated without the correction. Three-dimensional T1 maps were obtained, and the mean T1 in healthy rat lungs was 35 ± 10 ms, and in rat lungs with pulmonary hypertension - 41 ± 9 ms. CONCLUSION: OFCB has a spin-rotational relaxation mechanism and can be used for 19 F T1 mapping of lungs. The calculated OFCB maps captured ventilation defects induced by edema.


Assuntos
Hipertensão Pulmonar , Ratos , Animais , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas
9.
Chemistry ; 29(53): e202301442, 2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37606898

RESUMO

A new fluorinated manganese porphyrin, (Mn-TPP-p-CF3 ) is reported capable of providing, based on the Mn(III)/Mn(II) equilibrium, dual 1 H relaxivity and 19 F NMR response to redox changes. The physical-chemical characterization of both redox states in DMSO-d6 /H2 O evidenced that the 1 H relaxometric and 19 F NMR properties are appropriate for differential redox MRI detection. The Mn(III)-F distance (dMn-F =9.7-10 Å), as assessed by DFT calculations, is well tailored to allow for adequate paramagnetic effect of Mn(III) on 19 F T1 and T2 relaxation times. Mn-TPP-p-CF3 has a reversible Mn(II)/Mn(III) redox potential of 0.574 V vs. NHE in deoxygenated aqueous HEPES/ THF solution. The reduction of Mn(III)-TPP-p-CF3 in the presence of ascorbic acid is slowly, but fully reversed in the presence of air oxygen, as monitored by UV-Vis spectrometry and 19 F NMR. The broad 1 H and 19 F NMR signals of Mn(III)-TPP-p-CF3 disappear in the presence of 1 equivalent ascorbate replaced by a shifted and broadened 19 F NMR signal from Mn(II)-TPP-p-CF3 . Phantom 19 F MR images in DMSO show a MRI signal intensity decrease upon reduction of Mn(III)-TPP-p-CF3 , retrieved upon complete reoxidation in air within ~24 h. 1 H NMRD curves of the Mn(III)/(II)-TPP-p-CF3 chelates in mixed DMSO/water solvent have the typical shape of Mn(II)/Mn(III) porphyrins.

10.
Macromol Rapid Commun ; 44(16): e2200744, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36512446

RESUMO

Visualization of biomolecules, cells, and tissues, as well as metabolic processes in vivo is significant for studying the associated biological activities. Fluorine magnetic resonance imaging (19 F MRI) holds potential among various imaging technologies thanks to its negligible background signal and deep tissue penetration in vivo. To achieve detection on the targets with high resolution and accuracy, requirements of high-performance 19 F MRI probes are demanding. An ideal 19 F MRI probe is thought to have, first, fluorine tags with magnetically equivalent 19 F nuclei, second, high fluorine content, third, adequate fluorine nuclei mobility, as well as excellent water solubility or dispersity, but not limited to. This review summarizes the research progresses of 19 F MRI probes and mainly discusses the impacts of structures on in vitro and in vivo imaging performances. Additionally, the applications of 19 F MRI probes in ions sensing, molecular structures analysis, cells tracking, and in vivo diagnosis of disease lesions are also covered in this article. From authors' perspectives, this review is able to provide inspirations for relevant researchers on designing and synthesizing advanced 19 F MRI probes.


Assuntos
Meios de Contraste , Flúor , Flúor/química , Meios de Contraste/química , Imageamento por Ressonância Magnética , Íons
11.
Angew Chem Int Ed Engl ; 62(50): e202313753, 2023 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-37899303

RESUMO

The abnormality in the glycosylation of surface proteins is critical for the growth and metastasis of tumors and their capacity for immunosuppression and drug resistance. This anomaly offers an entry point for real-time analysis on glycosylation fluctuations. In this study, we report a strategy, glycan metabolic fluorine labeling (MEFLA), for selectively tagging glycans of tumor cells. As a proof of concept, we synthesized two fluorinated unnatural monosaccharides with distinctive 19 F chemical shifts (Ac4 ManNTfe and Ac4 GalNTfa). These two probes could undergo selective uptake by tumor cells and subsequent incorporation into surface glycans. This approach enables efficient and specific 19 F labeling of tumor cells, which permits in vivo tracking of tumor cells and in situ assessment of glycosylation changes by 19 F MRI. The efficiency and specificity of our probes for labeling tumor cells were verified in vitro with A549 cells. The feasibility of our method was further validated with in vivo experiments on A549 tumor-bearing mice. Moreover, the capacity of our approach for assessing glycosylation changes of tumor cells was illustrated both in vitro and in vivo. Our studies provide a promising means for visualizing tumor cells in vivo and assessing their glycosylation variations in situ through targeted multiplexed 19 F MRI.


Assuntos
Flúor , Monossacarídeos , Animais , Camundongos , Glicosilação , Monossacarídeos/metabolismo , Polissacarídeos/metabolismo
12.
Mol Cancer ; 21(1): 212, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36457016

RESUMO

BACKGROUND: Non-small cell lung cancer (NSCLC) patients with primary tumors and liver metastases have substantially reduced survival. Since mesenchymal-epithelial transition factor (MET) plays a significant role in the molecular mechanisms of advanced NSCLC, small molecule MET inhibitor capmatinib (INC280) hold promise for clinically NSCLC treatment. However, the major obstacles of MET-targeted therapy are poor drug solubility and off-tumor effects, even oral high-dosing regimens cannot significantly increase the therapeutic drug concentration in primary and metastatic NSCLC. METHODS: We developed a multirooted delivery system INC280-PFCE nanoparticles (NPs) by loading INC280 into perfluoro-15-crown-5-ether for improving MET-targeted therapy. Biodistribution and anti-MET/antimetastatic effects of NPs were validated in orthotopic NSCLC and NSCLC liver metastasis models in a single low-dose. The efficacy of INC280-PFCE NPs was also explored in human NSCLC specimens. RESULTS: INC280-PFCE NPs exhibited excellent antitumor ability in vitro. In orthotopic NSCLC models, sustained release and prolonged retention behaviors of INC280-PFCE NPs within tumors could be visualized in real-time by 19F magnetic resonance imaging (19F-MRI), and single pulmonary administration of NPs showed more significant tumor growth inhibition than oral administration of free INC280 at a tenfold higher dose. Furthermore, a single low-dose INC280-PFCE NPs administered intravenously suppressed widespread dissemination of liver metastasis without systemic toxicity. Finally, we verified the clinical translation potential of INC280-PFCE NPs in human NSCLC specimens. CONCLUSIONS: These results demonstrated high anti-MET/antimetastatic efficacies, real-time MRI visualization and high biocompatibility of NPs after a single low-dose.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Hepáticas , Neoplasias Pulmonares , Nanopartículas , Humanos , Medicina de Precisão , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Distribuição Tecidual , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Hepáticas/tratamento farmacológico
13.
Small ; 18(41): e2107308, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36074982

RESUMO

A labeling strategy for in vivo 19 F-MRI (magnetic resonance imaging) based on highly fluorinated, short hydrophilic peptide probes, is developed. As dual-purpose probes, they are functionalized further by a fluorophore and an alkyne moiety for bioconjugation. High fluorination is achieved by three perfluoro-tert-butyl groups, introduced into asparagine analogues by chemically stable amide bond linkages. d-amino acids and ß-alanine in the sequences endow the peptide probes with low cytotoxicity and high serum stability. This design also yielded unstructured peptides, rendering all 27 19 F substitutions chemically equivalent, giving rise to a single 19 F-NMR resonance with <10 Hz linewidth. The resulting performance in 19 F-MRI is demonstrated for six different peptide probes. Using fluorescence microscopy, these probes are found to exhibit high stability and long circulation times in living zebrafish embryos. Furthermore, the probes can be conjugated to bovine serum albumin with only amoderate increase in 19 F-NMR linewidth to ≈30 Hz. Overall, these peptide probes are hence suitable for in vivo 19 F-MRI applications.


Assuntos
Asparagina , Soroalbumina Bovina , Alcinos , Amidas , Aminoácidos/química , Animais , Imageamento por Ressonância Magnética , Peptídeos/química , Peixe-Zebra , beta-Alanina
14.
Magn Reson Med ; 87(4): 1952-1970, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34812528

RESUMO

PURPOSE: Low SNR in fluorine-19 (19 F) MRI benefits from cryogenically-cooled transceive surface RF probes (CRPs), but strong B1 inhomogeneities hinder quantification. Rapid acquisition with refocused echoes (RARE) is an SNR-efficient method for MRI of neuroinflammation with perfluorinated compounds but lacks an analytical signal intensity equation to retrospectively correct B1 inhomogeneity. Here, a workflow was proposed and validated to correct and quantify 19 F-MR signals from the inflamed mouse brain using a 19 F-CRP. METHODS: In vivo 19 F-MR images were acquired in a neuroinflammation mouse model with a quadrature 19 F-CRP using an imaging setup including 3D-printed components to acquire co-localized anatomical and 19 F images. Model-based corrections were validated on a uniform 19 F phantom and in the neuroinflammatory model. Corrected 19 F-MR images were benchmarked against reference images and overlaid on in vivo 1 H-MR images. Computed concentration uncertainty maps using Monte Carlo simulations served as a measure of performance of the B1 corrections. RESULTS: Our study reports on the first quantitative in vivo 19 F-MR images of an inflamed mouse brain using a 19 F-CRP, including in vivo T1 calculations for 19 F-nanoparticles during pathology and B1 corrections for 19 F-signal quantification. Model-based corrections markedly improved 19 F-signal quantification from errors > 50% to < 10% in a uniform phantom (p < 0.001). Concentration uncertainty maps ex vivo and in vivo yielded uncertainties that were generally < 25%. Monte Carlo simulations prescribed SNR ≥ 10.1 to reduce uncertainties < 10%, and SNR ≥ 4.25 to achieve uncertainties < 25%. CONCLUSION: Our model-based correction method facilitated 19 F signal quantification in the inflamed mouse brain when using the SNR-boosting 19 F-CRP technology, paving the way for future low-SNR 19 F-MRI applications in vivo.


Assuntos
Imageamento por Ressonância Magnética , Doenças Neuroinflamatórias , Animais , Imageamento por Ressonância Magnética/métodos , Camundongos , Imagens de Fantasmas , Ondas de Rádio , Estudos Retrospectivos
15.
Chemistry ; 28(5): e202102556, 2022 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-34705306

RESUMO

Magnetic resonance imaging (MRI) is one of the most powerful imaging tools today, capable of displaying superior soft-tissue contrast. This review discusses developments in the field of 19 F MRI multimodal probes in combination with optical fluorescence imaging (OFI), 1 H MRI, chemical exchange saturation transfer (CEST) MRI, ultrasonography (USG), X-ray computed tomography (CT), single photon emission tomography (SPECT), positron emission tomography (PET), and photoacoustic imaging (PAI). In each case, multimodal 19 F MRI probes compensate for the deficiency of individual techniques and offer improved sensitivity or accuracy of detection over unimodal counterparts. Strategies for designing 19 F MRI multimodal probes are described with respect to their structure, physicochemical properties, biocompatibility, and the quality of images.


Assuntos
Imagem Multimodal , Tomografia por Emissão de Pósitrons , Imageamento por Ressonância Magnética , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
16.
Angew Chem Int Ed Engl ; 61(50): e202213495, 2022 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-36263727

RESUMO

Nitroreductase (NTR) is an important biomarker widely used to evaluate the degree of tumor hypoxia. Although a few optical methods have been reported for detecting nitroreductase at low concentration ranges, an effective strategy for nitroreductase monitoring in vivo without limits to the imaging depth is still lacking. Herein, a novel dual-mode NIR fluorescence and 19 F MRI agent, FCy7-NO2 , is proposed for imaging tumor hypoxia. We show that FCy7-NO2 serves as not only a rapid NIR fluorescence enhanced probe for monitoring and bioimaging of nitroreductase in tumors, but also a novel 19 F MR chemical shift-sensitive contrast agent for selectively detecting nitroreductase catalyzed reduction. Notably, integrating two complementary imaging technologies into FCy7-NO2 enables sensitive detection of nitroreductase in a broad concentration range without tissue-depth limit. In general, this agent has a remarkable response to nitroreductase, which provides a promising method for understanding tumor evolution and its physiological role in the hypoxic microenvironment.


Assuntos
Neoplasias , Dióxido de Nitrogênio , Humanos , Corantes Fluorescentes/química , Microscopia de Fluorescência/métodos , Nitrorredutases/química , Imagem Óptica/métodos , Neoplasias/diagnóstico por imagem , Imageamento por Ressonância Magnética , Microambiente Tumoral
17.
Angew Chem Int Ed Engl ; 61(48): e202206074, 2022 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-36222012

RESUMO

Lipid peroxides accumulation induced ferroptosis is an effective cell death pathway for cancer therapy. However, the hypoxic condition of tumor microenvironment significantly suppresses the efficacy of ferroptosis. Here, we design a novel nanoplatform to overcome hypoxia-induced ferroptosis resistance. Specifically, we synthesize a novel kind of perfluorocarbon (PFOB)@manganese oxide (MnOx) core-shell nanoparticles (PM-CS NPs). Owing to the good carrier of O2 as fuel, PM-CS NPs can induce higher level of ROS generation, lipid peroxidation and GSH depletion, as well as lower activity of GPX4, compared with MnOx NPs alone. Moreover, the supplement of O2 can relieve tumor hypoxia to break down the storage of intracellular lipid droplets and increase expression of ACSL4 (a symbol for ferroptosis sensitivity). Furthermore, upon stimulus of GSH or acidity, PM-CS NPs exhibit the "turn on" 19 F-MRI signal and activatable T1 /T2 -MRI contrast for correlating with the release of Mn. Finally, PM-CS NPs exert high cancer inhibition rate for ferroptosis based therapy via synergetic combination of O2 -mediated enhancement of key pathways of ferroptosis.


Assuntos
Ferroptose , Nanoestruturas , Humanos , Linhagem Celular Tumoral , Imageamento por Ressonância Magnética , Hipóxia
18.
Magn Reson Med ; 85(6): 3343-3352, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33507591

RESUMO

PURPOSE: To assess the reproducibility of percentage ventilated lung volume (%VV) measurements in healthy volunteers acquired by fluorine (19 F)-MRI of inhaled perfluoropropane, implemented at two research sites. METHODS: In this prospective, ethically approved study, 40 healthy participants were recruited (May 2018-June 2019) to one of two research sites. Participants underwent a single MRI scan session on a 3T scanner, involving periodic inhalation of a 79% perfluoropropane/21% oxygen gas mixture. Each gas inhalation session lasted about 30 seconds, consisting of three deep breaths of gas followed by a breath-hold. Four 19 F-MR ventilation images were acquired per participant, each separated by approximately 6 minutes. The value of %VV was determined by registering separately acquired 1 H images to ventilation images before semi-automated image segmentation, performed independently by two observers. Reproducibility of %VV measurements was assessed by components of variance, intraclass correlation coefficients, coefficients of variation (CoV), and the Dice similarity coefficient. RESULTS: The MRI scans were well tolerated throughout, with no adverse events. There was a high degree of consistency in %VV measurements for each participant (CoVobserver1 = 0.43%; CoVobserver2 = 0.63%), with overall precision of %VV measurements determined to be within ± 1.7% (95% confidence interval). Interobserver agreement in %VV measurements revealed a high mean Dice similarity coefficient (SD) of 0.97 (0.02), with only minor discrepancies between observers. CONCLUSION: We demonstrate good reproducibility of %VV measurements in a group of healthy participants using 19 F-MRI of inhaled perfluoropropane. Our methods have been successfully implemented across two different study sites, supporting the feasibility of performing larger multicenter clinical studies.


Assuntos
Flúor , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Feminino , Flúor/administração & dosagem , Flúor/farmacocinética , Fluorocarbonos/administração & dosagem , Fluorocarbonos/farmacocinética , Humanos , Pulmão/metabolismo , Medidas de Volume Pulmonar/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
19.
Nano Lett ; 20(1): 363-371, 2020 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-31838855

RESUMO

Molecular probes featuring promising capabilities including specific targeting, high signal-to-noise ratio, and in situ visualization of deep tissues are in great demand for tumor diagnosis and therapy. 19F magnetic resonance imaging (MRI) techniques incorporating stimuli-responsive probes are anticipated to be highly beneficial for specific detection and imaging of tumors because of negligible background and deep tissue penetration. Herein, we report a cascaded multiresponsive self-assembled nanoprobe, which enables sequential redox-triggered and near-infrared (NIR) irradiation-induced 19F MR signal activation/amplification for sensing and imaging. Specifically, we designed and synthesized a cascaded multiresponsive 19F-bearing nanoprobe based on the self-assembly of amphiphilic redox-responsive 19F-containing polymers and NIR-absorbing indocyanine green (ICG) molecules. It could realize the activation of 19F signals in the reducing tumor microenvironment and subsequent signal amplification via the photothermal process. This stepwise two-stage activation/amplification of 19F signals was validated by 19F NMR and MRI both in vitro and in vivo. The multiresponsive 19F nanoprobes capable of cascaded 19F signal activation/amplification and photothermal effect exertion can provide accurate sensing and imaging of tumors.


Assuntos
Imagem por Ressonância Magnética de Flúor-19 , Raios Infravermelhos , Neoplasias Hepáticas Experimentais/diagnóstico por imagem , Nanopartículas , Microambiente Tumoral/efeitos dos fármacos , Animais , Feminino , Células Hep G2 , Humanos , Camundongos , Camundongos Nus , Nanopartículas/química , Nanopartículas/uso terapêutico
20.
Nano Lett ; 20(10): 7207-7212, 2020 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-32897716

RESUMO

Paramagnetic relaxation enhancement (PRE) is the current strategy of choice for enhancing magnetic resonance imaging (MRI) contrast and for accelerating MRI acquisition schemes. Yet, debates regarding lanthanides' biocompatibility and PRE-effect on MRI signal quantification have raised the need for alternative strategies for relaxation enhancement. Herein, we show an approach for shortening the spin-lattice relaxation time (T1) of fluoride-based nanocrystals (NCs) that are used for in vivo 19F-MRI, by inducing crystal defects in their solid-crystal core. By utilizing a phosphate-based rather than a carboxylate-based capping ligand for the synthesis of CaF2 NCs, we were able to induce grain boundary defects in the NC lattice. The obtained defects led to a 10-fold shorter T1 of the NCs' fluorides. Such paramagnetic-free relaxation enhancement of CaF2 NCs, gained without affecting either their size or their colloidal characteristics, improved 4-fold the obtained 19F-MRI signal-to-noise ratio, allowing their use, in vivo, with enhanced hotspot MRI sensitivity.


Assuntos
Fluoretos , Nanopartículas , Meios de Contraste , Ligantes , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA