1.
Magn Reson Med ; 91(6): 2310-2319, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38156825

RESUMO

PURPOSE: This study aimed to evaluate the potential of 3D EPI for improving the reliability of T 2 * $$ {\mathrm{T}}_2^{\ast } $$ -weighted data and quantification of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ decay rate and susceptibility (χ) compared with conventional gradient-echo (GRE)-based acquisition. METHODS: Eight healthy subjects in a wide age range were recruited. Each subject received repeated scans for both GRE and EPI acquisitions with an isotropic 1 mm resolution at 3 T. Maps of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and χ were quantified, and their interscan differences were used to evaluate the test-retest reliability. Interprotocol differences of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and χ between GRE and EPI were also measured voxel by voxel and in selected regions of interest to test the consistency between the two acquisition methods. RESULTS: The quantifications of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and χ using EPI protocols showed increased test-retest reliability with higher EPI factors up to 5 as performed in the experiment and were consistent with those based on GRE. CONCLUSION: The result suggests that multishot multi-echo 3D EPI can be a useful alternative acquisition method for T 2 * $$ {\mathrm{T}}_2^{\ast } $$ -weighted MRI and quantification of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ and χ with reduced scan time, improved test-retest reliability, and similar accuracy compared with commonly used 3D GRE.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Humanos , Imagem Ecoplanar/métodos , Reprodutibilidade dos Testes , Voluntários Saudáveis
2.
Eur Radiol ; 27(4): 1596-1604, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27436014

RESUMO

OBJECTIVE: To quantitatively compare the extent of enhancement of abdominal structures on MRI in an intraindividual fashion at 1.5 and 3 T. METHODS: HIPAA-compliant, retrospective, longitudinal, intraindividual, crossover study, with waived informed consent, of consecutive individuals scanned at both 1.5 and 3 T closed-bore magnets using gadobenate dimeglumine during different phases of enhancement at tightly controlled arterial phase timing. Quantitative ROI measurements and qualitative sub-phase arterial phase assignments were independently performed by two radiologists. Qualitative discrepancies were resolved by a senior radiologist. RESULTS: Final population included 60 patients [41 female and 19 male; age, 49.35 ± 18.31 years (range 16-81); weight, 78.88 ± 20.3 kg (range 44.5-136)]. Similar enhancement peak patterns were noted at both field strengths. Interobserver agreement of quantitative evaluations was substantial. Significantly higher amplitudes of enhancement peaks were noted for all abdominal solid organs during all phases at 3 T, except for the pancreas (p = 0.17-0.30). Significantly higher amplitudes of enhancement peaks of the abdominal aorta at 1.5 T were noted. CONCLUSION: Similar peak patterns of enhancement for abdominal structures were observed at 1.5 and 3 T, with solid abdominal organs showing a higher percentage enhancement at 3 T, while unexpectedly higher aortic higher percentage enhancement was observed at 1.5 T. KEY POINTS: • Similar enhancement peak patterns at both field strengths for studied abdominal structures. • Significantly higher percentage enhancement of most abdominal organs at 3 T. • Non-statistically significant trend of higher pancreatic percentage enhancement at 3 T. • Significantly lower abdominal aortic percentage enhancement at 3 T.


Assuntos
Abdome/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Cross-Over , Feminino , Humanos , Estudos Longitudinais , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
3.
Acta Radiol ; 57(8): 955-63, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26567963

RESUMO

BACKGROUND: Pediatric and adult patients unable to suspend respiration generally undergo magnetic resonance (MR) examinations that lack arterial phase imaging, which is a phase that provides substantial information on disease processes. An MR strategy that provides this type of information may be of considerable value. PURPOSE: To describe and assess the feasibility and enhancement quality of early-phase imaging utilizing long-duration radial 3D-GRE imaging by initiating the sequence prior to starting contrast injection. MATERIAL AND METHODS: Thirty-three consecutive patients (10 men, 23 women; 50.7 ± 25.5 years) underwent free-breathing gadolinium-enhanced radial 3D-GRE, with sequence initiation 30 s prior to contrast injection. Late hepatic arterial (LHA) phase was chosen for comparison. Images were evaluated for enhancement and overall image quality. Organ enhancement was calculated. Sub-group analysis was performed. RESULTS: Twenty-two examinations of radial 3D-GRE sequences were acquired during the LHA phase. Organ enhancement scores were of satisfactory to good quality (range, 3.32-3.82). There was a significant trend of superior overall enhancement quality scores in pediatrics and examinations performed at 3 T (P = 0.0225 and 0.0001, respectively). CONCLUSION: Arterial phase abdominal MR imaging is feasible using conventional radial 3D-GRE by adopting this simplistic proposed approach, which may allow arterial-phase imaging in patients unable to breath-hold.


Assuntos
Abdome/diagnóstico por imagem , Suspensão da Respiração , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Cooperação do Paciente , Criança , Pré-Escolar , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Eur Radiol ; 25(12): 3596-605, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25916391

RESUMO

OBJECTIVES: To assess the feasibility of high-resolution 3D-gradient-recalled echo (GRE) fat-suppressed T1-weighted images using controlled aliasing acceleration technique (CAIPIRINHA-VIBE), and compare image quality and lesion detection to standard-resolution 3D-GRE images using conventional acceleration technique (GRAPPA-VIBE). MATERIALS AND METHODS: Eighty-four patients (41 males, 43 females; age range: 14-90 years, 58.8 ± 15.6 years) underwent abdominal MRI at 1.5 T with CAIPIRINHA-VIBE [spatial resolution, 0.76 ± 0.04 mm] and GRAPPA-VIBE [spatial resolution, 1.17 ± 0.14 mm]. Two readers independently reviewed image quality, presence of artefacts, lesion conspicuity, and lesion detection. Kappa statistic was used to assess interobserver agreement. Wilcoxon signed-rank test was used for image qualitative pairwise comparisons. Logistic regression with post-hoc testing was used to evaluate statistical significance of lesions evaluation. RESULTS: Interobserver agreement ranged between 0.45-0.93. Pre-contrast CAIPIRINHA-VIBE showed significantly (p < 0.001) sharper images and lesion conspicuity with decreased residual aliasing, but more noise enhancement and inferior image quality. Post-contrast CAIPIRINHA-VIBE showed significantly (p < 0.001) sharper images and higher lesion conspicuity, with less respiratory motion and residual aliasing artefacts. Inferior fat-suppression was noticeable on CAIPIRINHA-VIBE sequences (p < 0.001). CONCLUSION: High in-plane resolution abdominal 3D-GRE fat-suppressed T1-weighted imaging using controlled-aliasing acceleration technique is feasible and yields sharper images compared to standard-resolution images using standard acceleration, with higher post-contrast image quality and trend for improved hepatic lesions detection. KEY POINTS: • High-resolution imaging of the upper abdomen is clinically feasible using 2D-controlled aliasing acceleration technique. • High-resolution imaging yields significantly sharper images and increased hepatic lesions conspicuity. • High-resolution imaging yields significantly less respiratory motion and residual aliasing artefacts. • Controlled-aliasing offers substantial acquisition-time reduction in patients with breath-holding difficulties.


Assuntos
Abdome/patologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Suspensão da Respiração , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reprodutibilidade dos Testes , Adulto Jovem
5.
ArXiv ; 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37645047

RESUMO

This study aimed to evaluate the potential of 3D echo-planar imaging (EPI) for improving the reliability of T2*-weighted (T2*w) data and quantification of R2* decay rate and susceptibility (χ) compared to conventional gradient echo (GRE)-based acquisition. Eight healthy subjects in a wide age range were recruited. Each subject received repeated scans for both GRE and EPI acquisitions with an isotropic 1 mm resolution at 3 T. Maps of R2* and χ were quantified and compared using their inter-scan difference to evaluate the test-retest reliability. Inter-protocol differences of R2* and χ between GRE and EPI were also measured voxel by voxel and in selected ROIs to test the consistency between the two acquisition methods. The quantifications of R2* and χ using EPI protocols showed increased test-retest reliability with higher EPI factors up to 5 as performed in the experiment and were consistent with those based on GRE. This result suggested multi-shot multi-echo 3D EPI can be a useful alternative acquisition method for T2*w MRI and quantification of R2* and χ with reduced scan time, improved test-retest reliability and similar accuracy compared to commonly used 3D GRE.

6.
Radiography (Lond) ; 25(2): e45-e51, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30955698

RESUMO

INTRODUCTION: This multi-site study evaluated two breath-hold sequences commonly utilised for liver MRI; non-enhanced T1W-3D-FS-GRE-TRA and T2W-2D-FSE-TRA sequences, using physical measurements of SNR and CNR, and observer perceptions' (Visual Grading Analysis: VGA). METHODS: Liver MR image datasets (n = 168) from nine hospitals in the Kingdom of Saudi Arabia (KSA) and 11 hospitals in the Republic of Ireland were evaluated. Images were categorised into two groups per sequence, defined by slice thickness (T2W-2D-FSE, ≤5 mm vs ≥ 6 mm and T1W-3D-GRE-FS, ≤3 mm vs 4 mm). Images were evaluated using visual grading analysis VGA and physical measurements: SNR/CNR. Account was taken of varying patient sizes based on AP/transverse diameter measurements. RESULTS: Physical image quality measurements (SNR/CNR) returned no significant findings across Irish and KSA hospitals, for both sequences, despite variations in acquisition parameters. Statistically significant differences were found for some scoring criteria based on the observers' perceptions including spleen parenchyma, and spatial resolution for the non-enhanced T1W-3D-FS-GRE-TRA images, with a preference for images acquired using thin slices (≤3 mm). In addition, statistically significant difference was found for the scoring criteria motion artefact for the axial T2W-2D-FSE-TRA images, with a preference for images acquired using thick slices (≥5 mm). Negligible correlation was noted between SNR/CNR and measured abdominal AP/transverse diameters. CONCLUSION: Whilst variations in sequences rendered no statistical differences in SNR/CNR findings, significant differences in observer image criteria scores was noted. The importance of both physical measurements and observers' perceptions evaluation methods for quality assessment of MR images was demonstrated and optimisation of liver sequence parameters is warranted.


Assuntos
Aumento da Imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Competência Clínica , Humanos , Imageamento Tridimensional , Irlanda , Imageamento por Ressonância Magnética/normas , Variações Dependentes do Observador , Arábia Saudita , Baço/diagnóstico por imagem
7.
Cancer Imaging ; 18(1): 21, 2018 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-29784058

RESUMO

BACKGROUND: To investigate the application value of fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI in regional nodes with different short-axis diameter ranges in rectal cancer, especially in nodes ≤5 mm. METHODS: Patients with rectal adenocarcinoma confirmed by postoperative histopathology were included, and all the patients underwent preoperative 3.0 T rectal magnetic resonance imaging (MRI) and total mesorectal excision (TME) within 2 weeks after an MR scan. The harvested nodes from specimens were matched with nodes in the field of view (FOV) of images for a node-by-node evaluation. The maximum short-axis diameters of all the visible nodes in the FOV of images were measured by a radiologist; the morphological and enhancement characteristics of these nodes were also independently evaluated by two radiologists. The χ 2 test was used to evaluate differences in morphological and enhancement characteristics between benign and malignant nodes. The enhancement characteristics were further compared between benign and malignant nodes with different short-axis diameter ranges using the χ 2 test. Kappa statistics were used to describe interobserver agreement. RESULTS: A total of 441 nodes from 70 enrolled patients were included in the evaluation, of which 111 nodes were metastatic. Approximately 85.5 and 95.6% of benign nodes were found to have obvious enhancement and homogeneous or mild-heterogeneous enhancement, respectively, whereas approximately 89.2 and 85.1% of malignant nodes showed moderate or mild enhancement and obvious-heterogeneous or rim-like enhancement, respectively. The area under the receiver operating characteristic (ROC) curve (AUC) values of the enhancement degree for identifying the overall nodal status, nodes ≤5 mm and nodes > 5 mm and ≤ 10 mm were 0.887, 0.859 and 0.766 for radiologist 1 and 0.892, 0.823 and 0.774 for radiologist 2, respectively. The AUCs of enhancement homogeneity were 0.940, 0.928 and 0.864 for radiologist 1 and 0.944, 0.938 and 0.842 for radiologist 2, respectively. Nodal border and signal homogeneity were also of certain value in distinguishing metastatic nodes. CONCLUSIONS: Enhancement characteristics based on fat-suppressed gadolinium-enhanced isotropic high-resolution 3D-GRE-T1WI were helpful for diagnosing metastatic nodes in rectal cancer and were a reliable indicator for nodes ≤5 mm.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Imagem Ecoplanar/métodos , Gadolínio/administração & dosagem , Neoplasias Retais/diagnóstico por imagem , Adenocarcinoma/patologia , Adulto , Idoso , Imagem Ecoplanar/normas , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Neoplasias Retais/patologia , Sensibilidade e Especificidade
8.
J Neurosurg ; 129(3): 620-628, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29027863

RESUMO

OBJECTIVE Accurate presurgical localization of microadenomas in Cushing's disease (CD) leads to improved remission rates and decreased adverse events. Volumetric gradient recalled echo (3D-GRE) MRI detects pituitary microadenomas in CD in up to 50%-80% cases as a focus of hypointensity due to delayed contrast wash-in. The authors have previously reported that postcontrast FLAIR imaging may be useful in detecting otherwise MRI-negative pituitary microadenomas as foci of hyperintensity. This reflects theoretically complementary imaging of microadenomas due to delayed contrast washout. The authors report on the diagnostic accuracy and clinical utility of FLAIR imaging in the detection of microadenomas in patients with CD. METHODS The authors prospectively analyzed imaging findings in 23 patients (24 tumors) with biochemically proven CD who underwent transsphenoidal surgery for CD. Preoperatively, the patients underwent pituitary MRI with postcontrast FLAIR and postcontrast 3D-GRE sequences. RESULTS Postcontrast FLAIR hyperintensity was detected in macroadenomas, and in 3D-GRE-positive or -negative microadenomas. Overall, 3D-GRE was superior in detecting surgically and histopathologically confirmed, location-concordant microadenomas. Of 24 pituitary adenomas, 18 (75%; sensitivity 82%, positive predictive value 95%) were found on 3D-GRE, and 13 (50% [1 was false positive]; sensitivity 55%, positive predictive value 92%) were correctly identified on FLAIR. The stand-alone specificity of 3D-GRE and FLAIR was similar (50%). These results confirm the superiority of 3D-GRE as a stand-alone imaging modality. The authors then tested the utility of FLAIR as a complementary tool to 3D-GRE imaging. All 5 patients with negative 3D-GRE MRI displayed a distinct focus of FLAIR enhancement. Four of those 5 cases (80%) had location-concordant positive histopathological results and achieved postsurgical biochemical remission. The remaining patient was not cured, because resection did not include the region of FLAIR hyperintensity. CONCLUSIONS This study suggests that delayed microadenoma contrast washout may be detected as FLAIR hyperintensity in otherwise MRI-negative CD cases. The authors propose adding postcontrast FLAIR sequences to complement 3D-GRE for surgical planning in patients with CD. Clinical trial registration no.: NIH protocol 03-N-0164, NCT00060541 (clinicaltrials.gov).


Assuntos
Adenoma/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Hipersecreção Hipofisária de ACTH/diagnóstico por imagem , Neoplasias Hipofisárias/diagnóstico por imagem , Adenoma/cirurgia , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hipersecreção Hipofisária de ACTH/cirurgia , Neoplasias Hipofisárias/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
Clin Imaging ; 40(4): 707-13, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27317215

RESUMO

PURPOSE: To compare diagnostic performance of two MRI protocols, motion resistant and conventional breath-hold, in patients with acute abdominal pain. MATERIALS AND METHODS: Thirty-five patients unable to breath-hold underwent a motion-resistant protocol (Radial group). Twenty-seven patients able to breath-hold underwent conventional protocol. The diagnostic performance of MRI was calculated. Cartesian and radial 3D-GRE sequences were compared. RESULTS: In Radial group, diagnosis was correct in 31/35 patients (88.5%), with sensitivity and specificity of 85.7% and 87.5%. In Cartesian group, diagnosis was correct in 24/27 patients (88.9%), with sensitivity and specificity of 93.7% and 81.8%. CONCLUSION: MRI appeared moderately successful for non-cooperative patients presenting with acute abdominal pain, with comparable accuracy to the standard breath-hold protocol.


Assuntos
Abdome Agudo/diagnóstico por imagem , Abdome/patologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Suspensão da Respiração , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem