Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.242
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Struct Biol ; 216(1): 108057, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38182035

RESUMO

Ctfplotter in the IMOD software package is a flexible program for determination of CTF parameters in tilt series images. It uses a novel approach to find astigmatism by measuring defocus in one-dimensional power spectra rotationally averaged over a series of restricted angular ranges. Comparisons with Ctffind, Gctf, and Warp show that Ctfplotter's estimated astigmatism is generally more reliable than that found by these programs that fit CTF parameters to two-dimensional power spectra, especially at higher tilt angles. In addition to that intrinsic advantage, Ctfplotter can reduce the variability in astigmatism estimates further by summing results over multiple tilt angles (typically 5), while still finding defocus for each individual image. Its fitting strategy also produces better phase estimates. The program now includes features for tuning the sampling of the power spectrum so that it is well-represented for analysis, and for determining an appropriate fitting range that can vary with tilt angle. It can thus be used automatically in a variety of situations, not just for fitting tilt series, and has been integrated into the SerialEM acquisition software for real-time determination of focus and astigmatism.


Assuntos
Algoritmos , Astigmatismo , Extratos Vegetais , Humanos , Astigmatismo/diagnóstico , Software , Processamento de Imagem Assistida por Computador/métodos , Microscopia Crioeletrônica/métodos
2.
Ophthalmology ; 131(3): 383-392, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38149945

RESUMO

PURPOSE: To review the published literature evaluating the visual and refractive outcomes and rotational stability of eyes implanted with toric monofocal intraocular lenses (IOLs) for the correction of keratometric astigmatism during cataract surgery and to compare those outcomes with outcomes of eyes implanted with nontoric monofocal IOLs and other astigmatism management methods performed during cataract surgery. This assessment was restricted to the toric IOLs available in the United States. METHODS: A literature search of English-language publications in the PubMed database was last conducted in July 2022. The search identified 906 potentially relevant citations, and after review of the abstracts, 63 were selected for full-text review. Twenty-one studies ultimately were determined to be relevant to the assessment criteria and were selected for inclusion. The panel methodologist assigned each a level of evidence rating; 12 studies were rated level I and 9 studies were rated level II. RESULTS: Eyes implanted with toric IOLs showed excellent postoperative uncorrected distance visual acuity (UCDVA), reduction of postoperative refractive astigmatism, and good rotational stability. Uncorrected distance visual acuity was better and postoperative cylinder was lower with toric IOLs, regardless of manufacturer, when compared with nontoric monofocal IOLs. Correcting pre-existing astigmatism with toric IOLs was more effective and predictable than using corneal relaxing incisions (CRIs), especially in the presence of higher magnitudes of astigmatism. CONCLUSIONS: Toric monofocal IOLs are effective in neutralizing pre-existing corneal astigmatism at the time of cataract surgery and result in better UCDVA and significant reductions in postoperative refractive astigmatism compared with nontoric monofocal IOLs. Toric IOLs result in better astigmatic correction than CRIs, particularly at high magnitudes of astigmatism. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Oftalmologia , Facoemulsificação , Humanos , Astigmatismo/cirurgia , Implante de Lente Intraocular , Desenho de Prótese , Refração Ocular
3.
Int J Med Sci ; 21(7): 1329-1336, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38818477

RESUMO

Purpose: The purpose of this study was to compare the differences in myopic control effects between orthokeratology (OK) contact lenses and defocus incorporated multiple segments (DIMS) spectacle lenses. Methods: A retrospective cohort study was conducted that included patients who had received OK lens, DIMS spectacle lens or single-vision spectacle treatments. A total of 54 eyes from 27 individuals, 38 eyes from 19 individuals and 42 eyes from 21 individuals were enrolled into the OK lens, DIMS and control groups, respectively. The primary outcomes were the changes in the spherical equivalent refraction (SER) and axial length (AXL) among the groups. A repeated-measure ANCOVA was adopted to calculate the SER progression and AXL elongation of the OK lens group compared with the DIMS group. Results: The difference in the SER progression was clinically non-significant in the OK lens group compared with the DIMS and control groups (P = 0.001). The total AXL elongation results were similar between the OK lens and DIMS groups, but these were lower than in the control group (P = 0.005). The repeated-measure ANCOVA revealed that the SER progression difference during the study interval was clinically non-significant in the OK lens group when compared with the DIMS group (P = 0.028). The AXL elongation results between the OK lens and DIMS populations did not illustrate a significant difference (P = 0.607). In a subgroup analysis of moderate astigmatism, better AXL control was observed in the DIMS subgroup compared with the OK lens subgroup (P = 0.016). Conclusions: The OK lens demonstrated a clinically non-significant effect on the SER and AXL controls compared with the DIMS spectacle lens.


Assuntos
Óculos , Miopia , Procedimentos Ortoceratológicos , Refração Ocular , Humanos , Miopia/terapia , Miopia/fisiopatologia , Masculino , Feminino , Procedimentos Ortoceratológicos/métodos , Estudos Retrospectivos , Refração Ocular/fisiologia , Adulto , Lentes de Contato , Adulto Jovem , Adolescente , Acuidade Visual , Resultado do Tratamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-38613688

RESUMO

PURPOSE: To report the prevalence data for total corneal astigmatism (TCA) in cataract patients. METHODS: The authors retrospectively collected and analyzed the preoperative biometric data of the patients who underwent cataract surgery in the Department of Ophthalmology, Peking University Third Hospital, from January 2019 to May 2023. RESULTS: The mean age of the 10817 patients was 71 ± 10 years; the male/female ratio was 4653/6164. The mean TCA obtained by the IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany), the Abulafia-Koch (AK) formula, and the Barrett toric calculator was 1.11 ± 0.81 diopter (D), 1.13 ± 0.75 D, and 1.12 ± 0.74 D respectively, which was significantly greater than the mean standard keratometric (K) astigmatism (0.99 ± 0.75 D) obtained by IOLMaster 700. Against-the-rule (ATR) astigmatism was dominant in all the TCA measurements, and its proportion increased with age. TCA measurements by different methods exhibit high variability, with a total of 1574 (8.9%) data sets from 1016 (9.4%) patients showing a difference larger than 0.5 D in at least one pair of TCA measurements. CONCLUSION: The use of TCA rather than K astigmatism significantly influenced the choice of intraocular lenses (IOLs) as more patients would be candidates for toric IOLs. It was essential to carefully compare and select TCA obtained with multiple methods for optimal postoperative visual quality.

5.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 249-260, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37552315

RESUMO

PURPOSE: The scientific community has established Javal's rule as a model linking refractive (RA) and keratometric (KA) astigmatism since its appearance more than 100 years ago. The aim was to improve the accuracy of this relationship according to subject's age by applying the power vector analysis. Posterior corneal curvature has also been studied. METHODS: The IOLMaster 700 optical biometer was used to measure the corneal thickness and the radius of curvature of the anterior and posterior corneal surfaces. Refractive error was determined by a non-cycloplegic subjective refraction process with trial lenses. Linear regression analyses were applied using J0 and J45 power vector components. An evaluation was carried out according to the subject's age resulting into eight regression relationships for each astigmatic vector component for each relationship. RESULTS: A total of 2254 right eyes from 2254 healthy subjects were evaluated. A trend towards against-the-rule astigmatism (ATR) was found with aging, both for refractive astigmatism (RA) and keratometric astigmatism (KA), with 95.2% of subjects under 20 years old having with-the-rule (WTR) KA, and only 22.8% above 79 years old. The following regression equations were found between RA and KA: [Formula: see text] = 0.73 × [Formula: see text] - 0.18 (R = 0.78) and [Formula: see text] = 0.70 × [Formula: see text] + 0.04 (R = 0.69) and between RA and total corneal astigmatism (TCA): [Formula: see text] = 0.73 × [Formula: see text] + 0.13 (R=0.78) and [Formula: see text] = 0.70 × [Formula: see text] - 0.06 (R = 0.68) for the whole sample, but with sensible differences among age groups, both in the slope and in the intercept. CONCLUSION: Ignoring the age of the subject when using Javal's rule could lead to an error in the final cylinder calculation that would increase in high astigmatisms. Applying this new power vector approach based on subject's age could improve the accuracy of the astigmatism prediction.


Assuntos
Astigmatismo , Erros de Refração , Humanos , Adulto Jovem , Adulto , Idoso , Astigmatismo/diagnóstico , Erros de Refração/diagnóstico , Refração Ocular , Córnea , Envelhecimento , Topografia da Córnea
6.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 295-303, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37410179

RESUMO

PURPOSE: To describe the association of refraction development and axial length (AL) in young children and provide new insights into the progression of cylinder power. METHODS: Children (2-3 grades) were enrolled from primary schools in Shanghai and followed up for two years. Cycloplegic refraction, AL, and corneal curvature radius were measured. Refraction parameters were compared among groups with different AL, AL1 (AL < 23.5 mm), AL2 (23.5 mm ≤ AL < 24.5 mm), and AL3 (AL ≥ 24.5 mm). Multiple regression analysis was used to explore risk factors of diopter of cylinder (DC) progression. RESULTS: In total, out of 6891 enrolled children, 5961 participants (7-11 yrs) were included in the final analysis. Over the two-year period, the cylinder power significantly changed, and those with longer AL had more rapid DC progression over the two years (AL1, -0.09 ± 0.35 D; AL2, -0.15 ± 0.39 D; AL3, -0.29 ± 0.44 D) (P < 0.001). The change in DC was independently associated with AL at baseline (P < 0.001). The proportion of with-the-rule astigmatism increased from 91.3% to 92.1% in AL1 group, from 89.1% to 91.8% in AL2 group and from 87.1% to 92.0% in AL3 group. CONCLUSIONS: Young children with long AL experienced rapid progression of cylinder power. Both the control of myopia progression and attention to the correction of astigmatism are necessary in the health management of children with long AL. The significantly increased AL in participants might contribute to both the extent and direction of astigmatism.


Assuntos
Astigmatismo , Criança , Humanos , Pré-Escolar , Seguimentos , Progressão da Doença , China , Refração Ocular , Comprimento Axial do Olho
7.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1169-1180, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37950754

RESUMO

PURPOSE: To evaluate the impact of residual astigmatism on the optical and visual performance of an enhanced-monofocal isofocal intraocular lens (EM Isopure, BVI medical, Belgium) compared to a monofocal one (Micropure, BVI medical, Belgium). METHODS: Laboratory investigation and prospective, comparative and randomized clinical study. Optical quality was assessed on an optical bench for 2.0, 3.0, and 4.5 mm pupils. The effect of residual astigmatism was investigated from through-focus images recorded with increasing amounts of regular positive astigmatism induced with a deformable mirror. To evaluate the impact of residual astigmatism, 28 eyes of 28 patients were randomly assigned to either group. Residual astigmatism was induced with positive and negative cylinder lenses at 90 and 180°. Visual acuity (VA) was measured at each step. RESULTS: The optical performance of both IOLs was quite similar for 2.0 and 3.0 mm pupils. For 4.5-mm pupil, the EM Isopure showed a significant reduction of its optical quality in comparison with the monofocal IOL. When visual performance was evaluated, no statistically significant differences were found for any power of induced astigmatism. More differences were found when positive induced astigmatism was compared within each group, and VA was better when the astigmatism was induced at 180° vs. 90°. The greatest differences were found for and induced positive astigmatism of + 1.50D (p = 0.009 for Isopure and p = 0.023 for Micropure). CONCLUSIONS: The tolerance to residual astigmatism of the EM Isopure lens is similar to that of a reference monofocal lens with pupils up to 3.5 mm.


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Astigmatismo/diagnóstico , Astigmatismo/cirurgia , Estudos Prospectivos , Facoemulsificação/métodos , Desenho de Prótese
8.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 133-141, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37470808

RESUMO

PURPOSE: Corneal scars after infectious keratitis lead to insufficient transparency and irregular astigmatism, affecting visual acuity; therefore, they should be accurately evaluated to estimate visual function. This study aimed to quantitatively evaluate corneal irregularity and scarring after infectious keratitis using anterior segment optical coherence tomography (AS-OCT). METHODS: This was an observational clinical study. We included patients who had corneal scarring after treatment of infectious keratitis between 2014 and 2021 at University of Tokyo Hospital. We retrospectively examined best spectacle-corrected visual acuity (BSCVA), average keratometric power, central corneal thickness (CCT), and four components of the Fourier harmonic analysis including spherical and asymmetry components, as well as regular astigmatism and higher-order irregularity. We included anterior and posterior corneal data and compared results with those of contralateral healthy eyes. Additionally, we quantitatively evaluated the densitometry of the cornea obtained using AS-OCT. RESULTS: A total of 122 eyes of 61 patients were examined; male predominance was observed (n = 37), and the mean patient age was 55.3 ± 19.4 years. Comparisons with contralateral healthy eyes showed that BSCVA worsened (0.30 ± 0.83 and 0.93 ± 1.36 logMAR, respectively, P = 0.003), and CCT (531.1 ± 46.2 and 591.8 ± 132.4 µm, respectively, P < 0.001) and corneal densitometry (84.4 ± 11.8 and 111.9 ± 19.2 grayscale units, respectively, P < 0.001) increased significantly in affected eyes. The asymmetry component and higher-order irregularities that were not corrected with spectacles significantly increased (both P < 0.001), and there were no significant differences in the changes among the bacterial, fungal, herpetic, and acanthamoeba types of keratitis. CONCLUSION: Corneal scarring persisted after treatment for infectious keratitis, and the asymmetry and irregularities of corneal astigmatism increased as visual acuity deteriorated. AS-OCT with the Fourier harmonic analysis was useful for evaluating corneal topographic changes in patients with corneal scarring after keratitis.


Assuntos
Astigmatismo , Lesões da Córnea , Ceratite , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Tomografia de Coerência Óptica/métodos , Cicatriz/patologia , Astigmatismo/patologia , Estudos Retrospectivos , Córnea/patologia , Topografia da Córnea , Lesões da Córnea/patologia
9.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 847-855, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37672101

RESUMO

OBJECTIVE: To study the effect of astigmatism correction, rotational stability, and related factors of two different haptic type toric intraocular lenses. METHODS: A prospective, randomized, controlled trial. Cataract patients with preoperative corneal astigmatism of > 1 D were randomly implanted with C-loop haptic toric IOL (AcrySof-toric IOL) (group A) or plate-haptic toric IOL (AT TORBI 709 M IOL) (group B). The residual astigmatism, intraocular lens rotation, and visual quality were determined and compared between the two groups at 3 months after surgery. RESULTS: Seventy-nine eyes were included in this study, including 40 eyes in the group A and 39 eyes in the group B. No significant difference in preoperative visual acuity, intraocular pressure, and ophthalmic biological parameters was found between the two groups. There was no significant difference in residual astigmatism between the two groups at 3 months after surgery (P > 0.05). The rotation degree in the group A was 3.85 ± 2.92°, the rotation degree in the group B was 2.33 ± 2.31°, and a significant difference in intraocular lens rotation was identified between the two groups (P < 0.05). Upon exploring the rotation-related factors of the two different haptic type toric intraocular lenses, the rotation after implanting C-loop haptic toric IOL was positively correlated with axial length (Pearson r = 0.522, P = 0.01) and corneal white-to-white distance (Pearson correlation analysis r = 0.356, P = 0.024). CONCLUSIONS: The two different haptic type toric intraocular lenses effectively corrected regular corneal astigmatism and provided a good rotational stability after surgery. But the stability of plate-haptic toric IOL was better than that of C-loop haptic toric IOL. The rotational stability of C-loop haptic toric IOL was often related to axial length and corneal white-to-white distance.


Assuntos
Astigmatismo , Doenças da Córnea , Lentes Intraoculares , Humanos , Astigmatismo/cirurgia , Tecnologia Háptica , Estudos Prospectivos , Córnea
10.
Graefes Arch Clin Exp Ophthalmol ; 262(2): 631-639, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37725147

RESUMO

PURPOSE: To explore the impact of the preoperative manifest cylinder on astigmatism correction via femtosecond lenticule extraction (FLEX), or small incision lenticule extraction (SMILE). METHODS: This was a prospective observational study. Eyes were categorized into mild (n = 88), moderate (n = 46), and severe (n = 53) astigmatism groups, based on the preoperative manifest cylinder. Vector analysis was conducted with the back vertex distance set at 12 mm. The primary outcome was the correction index (CI), with secondary outcomes including the safety, efficacy, predictability, and vectoral alterations related to FLEX. RESULTS: The average target-induced astigmatism was 0.45 ± 0.20 D, 0.95 ± 0.17 D, and 1.99 ± 0.65 D in the three groups (P < 0.001), and the average CI was 1.12± 0.05, 1.01 ± 0.03, and 0.95 ± 0.02 (P = 0.020), with the severe astigmatism group displaying a notably lower CI. The efficacy, safety, predictability, or stability of FLEX did not demonstrate any significant differences among the three groups. The CIs exhibited a significant difference in eyes with with-the-rule (WTR) astigmatism and against-the-rule (ATR) astigmatism from the mild to severe astigmatism group. In eyes with oblique astigmatism, the average CI exceeded one. CONCLUSION: Patients with manifest cylinder exceeding 1.25 D have a heightened risk of under-correction in WTR and ATR astigmatism compared to those with mild astigmatism, and mild over-correction may occur in cases of oblique astigmatism.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Miopia , Humanos , Acuidade Visual , Refração Ocular , Astigmatismo/cirurgia , Substância Própria/cirurgia , Lasers de Excimer , Miopia/cirurgia , Resultado do Tratamento
11.
BMC Ophthalmol ; 24(1): 252, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38867207

RESUMO

BACKGROUND: To comparatively analyze the surgically induced astigmatism (SIA) of the anterior, posterior, and total corneas of eyes undertaking implantable collamer lens (ICL) implantation with temporal or superior corneal incisions. METHODS: One hundred and nine eyes of 109 patients who received ICL implantation were recruited: 40 eyes had temporal incisions and 69 eyes had superior incisions. Total corneal refractive power (TCRP); simulated keratometry of the anterior (Sim-KAnt) and posterior (Sim-KPost) corneal curvature; and astigmatism of the anterior (CAAnt), posterior (CAPost), and total (CATCRP) cornea were recorded through a Pentacam preoperatively and 3 months postoperatively. The SIA of the anterior, posterior, and total cornea were also compared between the two groups. RESULTS: There were no significant intergroup differences for TCRP, Sim-KAnt, Sim-KPost, CAAnt, CAPost, or CATCRP, preoperatively. However, values of CAAnt, CAPost, and CATCRP with temporal incision were significantly higher than those parameters with superior incision postoperatively. All of the SIA of the anterior, posterior, and total cornea were significantly lower for temporal incision than those with a superior incision (p < 0.001, p = 0.006 and p = 0.001 respectively). Meanwhile, the superior incisions created against-the-rule (ATR) astigmatism, and temporal incisions always induce with-the-rule (WTR) astigmatism in total cornea. CONCLUSIONS: A superior incision may be suitable for correcting WTR astigmatism, while a temporal incision for correcting ATR astigmatism when using a non-toric ICL. Meanwhile, temporal incision could be a better choice with little preoperative astigmatism or that preoperative astigmatism would be corrected with toric ICLs. TRIAL REGISTRATION: Registration number: ChiCTR2100051739. Prospectively registered: 01 October 2021.


Assuntos
Astigmatismo , Córnea , Implante de Lente Intraocular , Lentes Intraoculares Fácicas , Refração Ocular , Acuidade Visual , Humanos , Astigmatismo/etiologia , Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Feminino , Masculino , Adulto , Córnea/cirurgia , Refração Ocular/fisiologia , Adulto Jovem , Miopia/cirurgia , Miopia/fisiopatologia , Pessoa de Meia-Idade , Topografia da Córnea , Estudos Retrospectivos , Complicações Pós-Operatórias/diagnóstico , Estudos Prospectivos
12.
BMC Ophthalmol ; 24(1): 45, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38287289

RESUMO

BACKGROUND: To evaluate the possible topographic and surgical risk factors for high postoperative residual astigmatism in patients who undergo small-incision lenticule extraction (SMILE) surgery and have different myopia degrees. METHODS: A retrospective cohort study was conducted, and patients who underwent SMILE surgery were enrolled. A total of 80 and 150 eyes from 40 to 75 individuals, respectively, were selected as the low myopia and high myopia groups. The demographic data, visual acuity, refraction, topographic parameters and surgical settings were recorded. Multiple linear regression with interaction tests were performed to survey the risk factors for high postoperative residual astigmatism in each group. RESULTS: Five (6.25%) and 9 (6.00%) eyes presented with high postoperative residual astigmatism in the low myopia and high myopia groups, respectively, but these differences were not significant (P = 0.569). A steep corneal curvature was correlated with a greater risk of high postoperative residual astigmatism in the low myopia group (P = 0.015), while a higher degree of cycloplegic cylinder power, steeper corneal curvature, greater topographic cylinder power, smaller optic zone and longer incision length were associated with a high rate of postoperative residual astigmatism in the high myopia group (all P < 0.05). In addition, the interaction effects of cycloplegic and topographic cylinder power and longer incision length on the incidence of high postoperative residual astigmatism development were more evident in the high myopia group than in the low myopia group (all P < 0.05). CONCLUSIONS: A steep corneal curvature correlates with a high risk of high postoperative residual astigmatism after SMILE surgery, and a higher degree of cycloplegic and topographic cylinder and longer incision are associated with high postoperative residual astigmatism in individuals with high myopia.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Miopia , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Estudos Retrospectivos , Midriáticos , Topografia da Córnea , Microcirurgia , Refração Ocular , Miopia/cirurgia , Córnea/cirurgia , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico
13.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741093

RESUMO

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Aberrações de Frente de Onda da Córnea , Miopia , Refração Ocular , Acuidade Visual , Humanos , Miopia/cirurgia , Miopia/fisiopatologia , Astigmatismo/fisiopatologia , Astigmatismo/etiologia , Masculino , Feminino , Adulto , Acuidade Visual/fisiologia , Cirurgia da Córnea a Laser/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Adulto Jovem , Refração Ocular/fisiologia , Substância Própria/cirurgia , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Complicações Pós-Operatórias , Topografia da Córnea , Adolescente
14.
BMC Ophthalmol ; 24(1): 179, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641836

RESUMO

BACKGROUND: Plusoptix photoscreeners are capable of measuring refractive errors of children from 1 meter distance, without cyloplegia. We aimed to compare refractive data obtained from the newest version of Plusoptix (model 12) with cycloplegic autorefraction. METHODS: We examined 111 consecutive children aged 3-7 years first by Plusoptix A12C under manifest condition and subsequently for cycloplegic refraction by Topcon KR-1 tabletop autorefractometer. Sphere, spherical equivalent, cylinder and axis of astigmatism measured by the two methods were analyzed to determine correlation, agreement and differences. RESULTS: Binocular examination of 111 children aged 4.86±1.27 years revealed good agreement between refractive data obtained by Plusoptix and cycloautorefraction, according to Bland-Altman plots. Significant (p < 0.001) and strong correlation was found between all refractive measurements (Pearson's r value of 0.707 for sphere, 0.756 for pherical equivalent, and 0.863 for cylinder). Plusoptix mean sphere, spherical equivalent and cylinder were 1.22, 0.56, and -1.32 D, respectively. Corresponding values for cycloautorefraction were 1.63, 1.00, and -1.26 D. The difference between axis of cylinder measured by the two methods was < 10° in 144 eyes (64.9%). CONCLUSIONS: Considering the significant agreement and correlation between Plusoptix photoscreener and cycloplegic autorefraction, the need for cycloplegic drops in refractive examination of children may be obviated. The mean difference between cylinder measurements are considerably trivial (0.06 D), but sphere is approximately 0.4 D underestimated by Plusoptix compared to cycloautorefraction, on average.


Assuntos
Astigmatismo , Erros de Refração , Seleção Visual , Criança , Humanos , Midriáticos , Seleção Visual/métodos , Erros de Refração/diagnóstico , Refração Ocular
15.
BMC Ophthalmol ; 24(1): 79, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378511

RESUMO

PURPOSE: To evaluate objective and subjective refraction differences in healthy young adults. METHODS: Data concerning candidates for the Israeli Air Force Flight Academy, as well as active air force pilots in all stages of service who underwent a routine health checkup between the years 2018 and 2019 were retrospectively analyzed. Objective refraction measured using a single autorefractometer was compared with subjective refraction measured by an experienced military optometrist during the same visit. The results were converted to power vectors (spherical equivalent [SE], J0, and J45). To interpret astigmatism using power vector values, the cylinder power (Cp) was determined. RESULTS: This study included 1,395 young adult participants. The average age was 22.17 years (range, 17-39, 84.8% males). The average SE was - 0.65 ± 1.19 diopter (D) compared with - 0.71 ± 0.91D in the auto- and subjective refraction, respectively (p = 0.001). Cp was 0.91 ± 0.52D and 0.67 ± 0.40D, respectively (p < 0.001). This difference was more common in older participants (p < 0.001). J0 and J45 value differences were not significant. The absolute SE value of subjective refraction was lower in the myopic (p < 0.001) and hyperopic (p < 0.001) patients. CONCLUSIONS: Young hyperopic participants tended to prefer "less plus" in subjective refraction compared with autorefraction. Young myopic participants tended to prefer "less minus" in subjective refraction compared with autorefraction. All participants, but mainly older participants, preferred slightly "less Cp" than that measured using autorefraction; The astigmatic axis did not differ significantly between the methods.


Assuntos
Hiperopia , Miopia , Masculino , Humanos , Adulto Jovem , Idoso , Adulto , Feminino , Estudos Retrospectivos , Refração Ocular , Testes Visuais
16.
BMC Ophthalmol ; 24(1): 116, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481203

RESUMO

BACKGROUND: To investigate the prevalence and risk factors for astigmatism in 7-19-year-old students in Xinjiang, China. METHODS: A school-based, cross-sectional study was conducted on students who underwent refraction examination in Xinjiang, China, between May and December 2019. The prevalence of astigmatism was determined. Astigmatism was defined as cylinder power (C) ≤-0.75 D, undefined astigmatism as ≤-1.50 D, and high astigmatism as C ≤-3.00 D. Astigmatism types were: against-the-rule astigmatism (maximum refraction of the main meridian in 180° ± 30°), with-the-rule astigmatism (maximum refraction of the main meridian at 90°±30°), and oblique astigmatism (all other cases). RESULTS: Of the 71,838 students examined (51.0% boys, 7 - 19 years old), 25,945 (36.1%, 95%CI: 35.52-36.68%) had astigmatism and 1267 (1.8%, 95%CI: 1.07-2.53%) had high astigmatism. The prevalence of astigmatism was greater in Han individuals (39.6%) compared with the Hui (34.0%), Kazakh (34.0%), Kyrgyz (32.1%), and Uyghur (26.4%) populations. Among the 25,945 students with astigmatism, 19,947 had with-the-rule astigmatism (76.9%), 3405 had against-the-rule astigmatism (13.1%), and 2593 had oblique astigmatism (10.0%). Multivariable logistic regression analysis showed that ethnicity (Han individuals more susceptible), male gender, age, and refractive errors (myopia and hyperopia) were independently associated with astigmatism, high astigmatism, and with-the-rule astigmatism (all P < 0.05). CONCLUSIONS: The prevalence of astigmatism among children and adolescents in Xinjiang was 36.1%, including 1.8% of high astigmatism. In this population, astigmatism was mainly of the with-the-rule astigmatism type (76.9%). Han ethnicity, male gender, and myopia or hyperopia were independently associated with a high risk of astigmatism.


Assuntos
Astigmatismo , Hiperopia , Miopia , Erros de Refração , Criança , Adolescente , Humanos , Masculino , Adulto Jovem , Adulto , Feminino , Astigmatismo/epidemiologia , Astigmatismo/diagnóstico , Estudos Transversais , Prevalência , Erros de Refração/epidemiologia , Miopia/epidemiologia , Estudantes , Fatores de Risco , China/epidemiologia
17.
BMC Ophthalmol ; 24(1): 83, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388340

RESUMO

BACKGROUND: To investigate and compare the vision-related quality of life (QOL) in different types of refractive error (RE). METHODS: This cross-sectional study was performed on 200 subjects, categorized into four groups of 50 each, consisting of subjects with myopia, hyperopia, astigmatism, and emmetropia, the latter being the control group. The mean age of the participants was 23.88 ± 5.87 (range, 15 to 38: 110 females and 90 males). RE was defined as myopia, spherical equivalent (SE) < -0.25 diopters (D), hyperopia, SE > + 0.25 D, astigmatism, cylinder < -0.25 D, and emmetropia (-0.25 ≤ SE(D) ≤ + 0.25, cylinder ≥ -0.25). Groups are subdivided into very low magnitudes of RE (0.50 and 0.75) and significant RE (1.00 ≤). Vision-related QOL was assessed using the Persian version of the 25-item National Eye Institute Visual Functioning Questionnaire (NEI-VFQ-25). The NEI-VFQ was scored as visual function and socioemotional scales using Rasch analysis. RESULTS: Corrected myopia, astigmatism, uncorrected myopia, and hyperopia had a lower vision-related QOL than emmetropes. (P < 0.001). Vision-related QOL in myopic subjects was lower than that in astigmatic participants. Very low myopes, who often do not use correction, had a significantly lower QOL than other groups. CONCLUSION: Individuals with refractive errors experience a lower QOL score than those without. Notably, the adverse impact on QOL score is significantly greater in myopic cases, particularly very low myopia, compared to other refractive errors. Therefore, it is strongly recommended not to neglect managing very low myopia since it may improve participants' QOL.


Assuntos
Astigmatismo , Hiperopia , Miopia , Erros de Refração , Masculino , Feminino , Humanos , Qualidade de Vida , Estudos Transversais
18.
BMC Ophthalmol ; 24(1): 170, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627750

RESUMO

BACKGROUND: This study aimed to compare the results of the Chronos binocular/monocular refraction system, that measures objective and subjective ocular refraction in one unit, to objective findings obtained from a conventional autorefractometer and a conventional subjective ocular refraction using a trial-frame in real space. METHODS: Twenty-eight healthy volunteers (21.2 ± 1.5 years old) were included in this study. Objective ocular refraction was measured using two tests: the Chronos binocular/monocular refraction system under binocular conditions and a conventional autorefractometer under monocular conditions. Subjective ocular refraction was measured using three tests: Chronos binocular/monocular refraction system under binocular, monocular conditions, and trial-frame in the real space under monocular conditions. The measurement distance was set to 5.0 m for each test. All ocular refractions were converted into spherical equivalents (SEs). RESULTS: The objective SE was significantly more negative with Chronos binocular/monocular refraction system under binocular condition (- 4.08 ± 2.76 D) than with the conventional autorefractometer under monocular condition (- 3.85 ± 2.66 D) (P = 0.002). Although, the subjective SE was significantly more negative with Chronos binocular/monocular refraction system under binocular condition (- 3.55 ± 2.67 D) than with the trial-frame in the real space under monocular condition (- 3.33 ± 2.75 D) (P = 0.002), Chronos binocular/monocular refraction system under monocular condition (- 3.17 ± 2.57 D) was not significantly different from that in trial-frame in real space under monocular condition (P = 0.33). CONCLUSION: These findings suggest that the Chronos binocular/monocular refraction system, which can complete both objective and subjective ocular refraction tests in a single unit, is suitable for screening ocular refraction, although it produces slightly more myopic results. Furthermore, subjective ocular refraction testing accuracy in Chronos binocular/monocular refraction system can be equivalent to trial-frame in real-space testing by switching from binocular to monocular condition.


Assuntos
Refração Ocular , Visão Binocular , Humanos , Adulto Jovem , Adulto , Acuidade Visual , Testes Visuais , Olho
19.
BMC Ophthalmol ; 24(1): 40, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273262

RESUMO

BACKGROUND: This study aimed to compare the corneal high-order aberrations and surgically induced astigmatism between the clear corneal incision and limbus tunnel incision for posterior chamber implantable collamer lens (ICL/TICL) implantation. METHODS: A total of 127 eyes from 73 myopic patients underwent ICL V4c implantation, with 70 eyes receiving clear corneal incisions and 57 eyes receiving limbus tunnel incisions. The anterior and back corneal surfaces were measured and the Root Mean Square of all activated aberrations (TRMS) was calculated, including higher-order aberration (HOA RMS), spherical aberration Z40, coma coefficients (Coma RMS) Z3-1 Z31, and surgically induced astigmatism (SIA). The measurements were taken preoperatively and postoperatively at 1 day, 1 week, and 1, 3, and 6 months. In this study, the corneal higher-order aberration was estimated as the Zernike coefficient calculated up to 5th order. The measurements were taken at a maximum diameter of 6.5 mm using Pentacam. RESULTS: One week after the operation, the corneal back Z31 of the clear corneal incision group was 0.06 ± 0.06, while the limbus tunnel incision group showed a measurement of 0.05 ± 0.06 (p = 0.031). The corneal back Z40 of the clear corneal incision group was -0.02 ± 0.25, compared to -0.04 ± 0.21 in the limbus tunnel incision group (p = 0.01). One month after the operation, the corneal back SIA of the clear corneal incision group was 0.11 ± 0.11, compared to 0.08 ± 0.11of the limbus tunnel incision group (p = 0.013), the corneal total SIA of the clear corneal incision group was 0.33 ± 0.30, compared to 0.15 ± 0.16 in the limbus tunnel incision group (p = 0.004); the clear corneal incision group exhibited higher levels of back astigmatism and total SIA than the limbus tunnel incision in the post-operation one month period. During the 6- month post-operative follow-up period, no significant difference in Z31, Z40, and other HOA RMS data was observed between the two groups. The total SIA of the corneal incision group and the limbus tunnel incision group were 0.24 ± 0.14 and 0.33 ± 0.32, respectively (p = 0.393), showing no significant difference between the two groups 6 months after the operation. CONCLUSION: Our data showed no significant difference in the high-order aberration and SIA between clear corneal incision and limbus tunnel incision up to 6 months after ICL-V4c implantation.


Assuntos
Astigmatismo , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Implante de Lente Intraocular , Coma/cirurgia , Córnea/cirurgia , Pseudofacia/cirurgia
20.
BMC Ophthalmol ; 24(1): 72, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38365667

RESUMO

PURPOSE: To compare the rotational stability of a monofocal and a diffractive multifocal toric intraocular lens(IOLs) with identical design and material. METHODS: This prospective study enrolled patients who underwent plate-haptic toric IOL (AT TORBI 709 M and AT LISA 909 M) implantation. Propensity score matching (PSM) was performed to balance baseline factors. Follow-up examinations were conducted at 1 h, 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. A linear mixed model of repeated measures was used to investigate the changes in IOL rotation over time. A 2-week timeframe was utilized to assess differences in IOL rotation between the two groups. RESULT: After PSM, a total of 126 eyes were selected from each group for further analysis. Postoperatively, the time course of IOL rotation change in the two groups remained consistent, with the greatest rotation occurring between 1 h and 1 day postoperatively. At the 2-week postoperative mark, the monofocal toric IOL exhibited a higher degree of rotation compared to the multifocal toric IOL (5.40 ± 7.77° vs. 3.53 ± 3.54°, P = 0.015). In lens thickness(LT) ≥ 4.5 mm and white-to-white distance(WTW) ≥ 11.6 mm subgroups, the monofocal toric IOL rotated greater than the multifocal toric IOL (P = 0.026 and P = 0.011, respectively). CONCLUSION: The diffractive multifocal toric IOL exhibits superior rotational stability compared to the monofocal toric IOL, especially in subgroups LT ≥ 4.5 mm and WTW ≥ 11.6 mm. Moreover, the time course of IOL rotation change is consistent for both, with the maximum rotation occurring between 1 h and 1 day postoperatively.


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Pseudofacia/cirurgia , Acuidade Visual , Pontuação de Propensão , Astigmatismo/cirurgia , Refração Ocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA