Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Surg Endosc ; 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39266761

RESUMO

AIM: The study objective was to evaluate the primary feasibility of endoscopic submucosal resection (ESD) and endoscopic full-thickness resection (EFTR) via balloon-assisted enteroscopy (BAE) to treat small bowel subepithelial lesions (SELs). METHOD: A retrospective case series study was performed. The first fifteen consecutive patients who underwent ESD (n = 10) and EFTR (n = 5) via BAE to remove small bowel SELs from November 2016 to December 2023 were included. The main outcome measures were the technique success rate, operative time and complication rate. RESULTS: This research focused on 15 cases of jejunoileal SELs, four cases of lipomyoma, three cases of ectopic pancreas, two cases of NETs, three cases of benign fibrous tumours and three cases of angioma. The overall technique success rate was 86.7%, with 100% (10/10) and 60% (3/5) for BAE-ESD and BAE-EFTR, respectively, in removing small bowel SELs. Two cases of EFTR failed, as the BAE operation was unsuitable for tumour resection and suture repair of a perforated wound. No serious bleeding or any postoperative complications occurred. The median time of endoscopic resection via BAE for SELs was 44 min (range 22-68 min). CONCLUSION: ESD and EFTR via BAE might be alternative choices for treating small SELs in the small bowel, with the advantages of clear and accurate positioning and minimal invasiveness. However, its superiority over surgery still needs to be further investigated.

2.
Scand J Gastroenterol ; 58(7): 805-812, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36651020

RESUMO

BACKGROUND: To analyze the diversity in endoscopic manifestations of Meckel's diverticulum (MD) in adults by using balloon-assisted enteroscopy (BAE) and supply more information on the application of BAE. METHODS: A retrospective study was carried out on adult patients diagnosed with MD by BAE in two tertiary general hospitals in China, from May 2007 to September 2021. The patients were divided into a small bowel bleeding (SBB) group and a control group according to their main symptoms. Clinical charts and endoscopic images were reviewed, analyzed, and summarized. RESULTS: Single diverticulum in the ileum and double-lumen sign were observed in all patients. The SBB group consisted of 51 patients, among which 35 cases of ulcerative lesions, 9 cases of erosive lesions, 9 cases of active bleeding/blood clots, and 4 cases of lumps inside the diverticulum were observed respectively. Majority of ulcerative lesions were inside the diverticulum (23/35). A circumferential stricture inside the diverticulum was discovered in 11 cases, and ulcerative lesions tended to occur at this structure (10/11). In the control group consisting of 15 patients, 1 case of erosive lesions at the orifice edge was observed. The percentage of patients with MD-associated ulcerative lesions was significantly higher in the SBB group than that in the control group (p < 0.001). CONCLUSIONS: The endoscopic manifestations of MD in adults are extraordinarily complex and connected with the patients' primary symptoms. The internal features of MD should be regarded as crucial observational objectives in adult patients.


Assuntos
Divertículo Ileal , Humanos , Adulto , Divertículo Ileal/complicações , Divertículo Ileal/diagnóstico , Estudos Retrospectivos , Hospitais Gerais , Íleo/patologia , China , Hemorragia Gastrointestinal/diagnóstico
3.
BMC Gastroenterol ; 23(1): 331, 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37759282

RESUMO

There are limited studies on the endoscopic assessment of disease activity using balloon-assisted enteroscopy (BAE) and its predictive role for long-term outcomes of patients with small bowel Crohn's disease (CD). We sought to investigate the value of BAE as a predictor of long-term outcomes in patients with small-bowel CD. A total of 111 patients with small-bowel CD whose endoscopic disease activity was assessed using BAE based on the small-bowel simple endoscopic score for Crohn's disease (small-bowel SES-CD) at Samsung Medical Center were retrospectively selected from January 2014 to August 2020. The outcome was an evaluation of the risk of surgery according to a small-bowel SES-CD of 0-6 vs. ≥ 7 and endoscopic findings (presence of any ulcer and degree of stricture) using the Cox proportional hazards model. The risk of surgery was significantly increased in patients with a small-bowel SES-CD of ≥ 7 compared to a small-bowel SES-CD of 0-6 [hazard ratio (HR) 6.31; 95% confidence interval (CI) 1.48-26.91; p = 0.013]. In addition, the risk of surgery was significantly increased in patients with stenosis with "cannot be passed" compared to the cases without stenosis (HR 12.34; 95% CI 1.66-91.92; p = 0.014), whereas there was no significance in any ulcer. The present study demonstrated the role of BAE in the endoscopic assessment of disease activity and its predictive value for the risk of surgery in small-bowel CD patients. Further optimization of BAE utilization for the assessment of disease activity is warranted in clinical practice.


Assuntos
Doença de Crohn , Enteropatias , Humanos , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/cirurgia , Constrição Patológica/etiologia , Estudos Retrospectivos , Úlcera
4.
Digestion ; 103(4): 308-318, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35398852

RESUMO

INTRODUCTION: An association has been found between human-gut microbiota and various diseases (e.g., metabolic disease) by analyzing fecal or colonic microbiota. Despite the importance of the small intestinal microbiota, sampling difficulties prevent its full analysis. We investigated the composition and metagenomic functions of microbiota along the small intestine and compared them with the microbiota from feces and from other gastrointestinal (GI) sites. METHODS: Mucosal samples from the six GI sites (stomach, duodenum, distal jejunum, proximal ileum, terminal ileum, and rectum) were collected under balloon-assisted enteroscopy. Fecal samples were collected from all participants. The microbial structures and metagenomic functions of the small intestinal mucosal microbiota were compared with those from feces and other GI sites using 16S ribosomal RNA gene sequencing. RESULTS: We analyzed 133 samples from 29 participants. Microbial beta diversity analysis showed that the jejunum and ileum differed significantly from the lower GI tract and the feces (p < 0.001). Jejunal and duodenal microbiotas formed similar clusters. Wide clusters spanning the upper and lower GI tracts were observed with the ileal microbiota, which differed significantly from the jejunal microbiota (p < 0.001). Veillonella and Streptococcus were abundant in the jejunum but less so in the lower GI tract and feces. The metagenomic functions associated with nutrient metabolism differed significantly between the small intestine and the feces. CONCLUSIONS: The fact that the compositional structures of small intestinal microbiota differed from those of fecal and other GI microbiotas reveals that analyzing the small intestinal microbiota is necessary for association studies on metabolic diseases and gut microbiota.


Assuntos
Microbioma Gastrointestinal , Microbiota , Fezes , Microbioma Gastrointestinal/genética , Humanos , Intestino Delgado , RNA Ribossômico 16S/genética
5.
Dig Dis Sci ; 67(7): 2882-2890, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34973148

RESUMO

BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy is technically difficult. Extensive training is required to develop the ability to perform this procedure. AIMS: To investigate the learning curve of single-balloon-assisted enteroscopy ERCP (SBE-ERCP). METHODS: We conducted a retrospective, observational case series at a single center. We evaluated the SBE-ERCP procedures between April 2011 and February 2021. The main outcomes were the rate of reaching the target site and the success rate of the entire procedure. These parameters were additionally expressed as a learning curve. RESULTS: A total of 687 SBE-ERCP procedures were analyzed. The learning curve was analyzed in blocks of 10 cases. In this study, seven endoscopists, experts in conventional ERCP, were included. The overall SBE-ERCP procedural success rate was 92.2% (634/687 cases). Combining all data from individual endoscopists' evaluation periods, the insertion and success rates of the SBE-ERCP procedures gradually increased with increased experience performing SBE-ERCP. The insertion success rates for the number of SBE-ERCP cases (< 20, 21-30, > 30) were 82.9%, 92.9%, and 94.3%, respectively; the procedure success rates were 74.3%, 81.4%, and 92.9%, respectively. The endoscopists who had performed > 30 SBE-ERCP cases had a success rate of ≥ 90%. CONCLUSIONS: Our results suggest that performing > 30 cases is one of the targets for conventional ERCP experts to become competent in performing SBE-ERCP in patients with a surgically altered anatomy.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Enteroscopia de Balão Único , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Enteroscopia de Duplo Balão , Humanos , Curva de Aprendizado , Estudos Retrospectivos
6.
Digestion ; 102(2): 180-187, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-31536998

RESUMO

BACKGROUND: Patency confirmation is useful for avoiding the retention of capsule endoscopy (CE). We first evaluated the clinical utility of the tag-less PillCamTM Patency Capsule (PPC) for up to 72 h after ingestion prospectively. METHODS: Excretion of an intact capsule or intact body within 72 h, or positive PPC image in the colon or negative PPC image by abdominal X-ray at 30 h was defined as confirmed functional patency. In patients with unconfirmed functional patency, balloon-assisted enteroscopy was performed to evaluate the reason. RESULTS: Functional patency was confirmed in 44 of 57 patients. Patency was confirmed in 38 patients (66.7%) at 30 h. In 6 of 19 patients (31.6%) in whom patency was not confirmed at 30 h, patency was confirmed within 72 h and no capsule retention (CR) occurred. The rate of pan-enteroscopy did not differ between patients whose patency was confirmed at 30 h and those whose patency was confirmed within 72 h. Excretion time of the PPC significantly correlated with that of the capsule (r = 0.650). Severe adhesions (>5 cm) interfered with PPC passage in 2 patients, despite the absence of critical stricture. The rate of no CR in patients with functional patency confirmed by prior PPC was 97.7%. Misjudgment of the location of the PPC is a risk for CR. CONCLUSIONS: Extending the time to confirm functional patency to 72 h may be acceptable and increase the possibility to perform CE safely in whom CE can perform intrinsically. University Hospital Medical Information Network registration No: 000002564.


Assuntos
Endoscopia por Cápsula , Constrição Patológica , Humanos , Estudos Prospectivos
7.
J Minim Access Surg ; 17(1): 104-107, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33353896

RESUMO

Jejunoileal neuroendocrine tumours (NETs) are frequently multifocal and represent a consistent source of obscure gastrointestinal bleeding (OGIB). We report the real-life case of a female presenting to our attention for severe episodes of haematochezia caused by multiple localisation of jejunoileal NETs. A discrepancy between pre-operative total body contrast-enhancement computed tomography scan and capsule endoscopy (CE) emerged, in terms of numbers of lesions, so that, as completeness, an intraoperative balloon-assisted enteroscopy (BAE) was carried out, leading to the detection of the multiple lesions missed during CE. In case of obscure gastrointestinal bleeding sources missed by capsule endoscopy, laparoscopic-assisted balloon enteroscopy plays an essential role, allowing both to assess a precise diagnosis and to resect the intestinal bleeding tract.

8.
Scand J Gastroenterol ; 55(10): 1243-1247, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32907435

RESUMO

BACKGROUND AND AIMS: The diagnostic yield (DY) and therapeutic yield (TY) of balloon-assisted enteroscopy (BAE) in overt obscure gastrointestinal bleeding (OGIB) is higher in the first 72 h. This study aimed to evaluate if this higher DY and TY after urgent BAE impacted the rebleeding rate, time to rebleed and short-term mortality. METHODS: Retrospective cohort-study, which consecutively included all patients submitted to BAE for overt OGIB, between 2010 and 2019. Patients were distributed in 2 groups: (1) Urgent BAE; (2) Non-urgent BAE. Rebleeding was defined as an Hb drop >2 g/dL, need for transfusional support or presence of melena/hematochezia. RESULTS: Fifty-four patients were included, of which 17 (31.5%) were submitted to BAE in the first 72 h. DY and TY of urgent BAE (DY 88.2%; n = 15; TY 94.1%; n = 16) was higher compared to non-urgent BAE (DY 59.5%; n = 22; TY 45.9%; n = 17) (DY p = .03) (TY p = .001). The rebleeding rate at 1, 2, and 5 years was 32.0%, 34.0%and 37.0%, respectively. Rebleeding was lower after urgent BAE (17.6%; n = 3) compared to non-urgent BAE (45.9%; n = 17) (p = .04). Rebleeding tended to occurr earlier in non-urgent BAE, being at 6-months (32.5%) and 36 months (41.3%) (p = .05). OGIB related 30-day mortality was 5.4% (n = 2) for non-urgent BAE and 0% for urgent BAE (p = .5). CONCLUSION: Urgent BAE might be associated with higher DY and TY with lower rebleeding and trend toward higher rebleeding-free time.


Assuntos
Hemorragia Gastrointestinal , Intestino Delgado , Enteroscopia de Duplo Balão , Hemorragia Gastrointestinal/etiologia , Humanos , Estudos Retrospectivos
9.
Dig Dis Sci ; 65(9): 2630-2636, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31894488

RESUMO

BACKGROUND: Predictors besides symptoms of obstruction indicating small bowel stenosis are little known. AIMS: To detect predictors of small bowel stenosis in balloon-assisted enteroscopy. METHODS: Over a 6-year period, 461 patients had enteroscopy for suspected small intestinal disease. Details of clinical manifestations, medical history, demographic characteristics, findings of examinations, information on enteroscopy, and treatment were retrospectively collected based on medical records. Small bowel stenosis was defined as stricture that over-tube cannot go through in enteroscopy. Univariate and multivariate analyses were performed to identify predictors for small bowel stenosis. RESULTS: A total of 314 patients had definite diagnosis after enteroscopy, imaging modalities, and/or even surgical exploration. They were included in this study for analyses. Mean age for them was 48.2 years old (range 15-81 years). Small bowel stenosis was present in 59 patients (18.8%). Analyses showed that CT/MRI indicating stenosis was significantly associated with severe stenosis (p = 0.014) but insignificant related to general stenosis (p = 0.097). Predictive factors that accompanied stenosis were age ≥ 60 years (OR = 2.1, 95% CI 1.1-4.0), underweight (BMI ≤ 18.5) (OR = 3.4, 95% CI 1.4-8.4), symptoms of obstruction (OR = 3.6, 95% CI 1.8-7.4), and overt small bowel bleeding (OR = 0.5, 95% CI 0.2-0.9). CONCLUSIONS: Small bowel stenosis more tended to occur to patients with symptoms of obstruction, no overt small bowel bleeding, age ≥ 60 years, or underweight.


Assuntos
Enteroscopia de Balão/efeitos adversos , Obstrução Intestinal/etiologia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Constrição Patológica , Feminino , Humanos , Obstrução Intestinal/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Magreza/complicações , Adulto Jovem
10.
Dig Dis Sci ; 64(8): 2256-2264, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30796686

RESUMO

BACKGROUND AND AIMS: Single-balloon enteroscopy (SBE) is utilized in the evaluation of obscure gastrointestinal bleeding, but 40-50% of these patients experience continued GI blood loss, in part due to missed lesions. The utilization of a transparent cap attached to the end of the endoscope can improve mucosal visualization in other endoscopic applications, but has not yet been evaluated in SBE. The aim of this study was to evaluate the impact of a cap on the diagnostic yield of SBE. METHODS: Consecutive adult patients scheduled for anterograde SBE for the evaluation of obscure GI bleeding were screened for inclusion from 2014 to 2017. Patients were randomized to SBE with or without a transparent cap. The primary outcome was the proportion of enteroscopies in which a P2 lesion (high potential for bleeding) was identified. RESULTS: A total of 90 patients (65.7 ± 12.7 years old, 47.7% female) were analyzed. There were significantly more P2 arteriovenous malformations identified in the cap group (14.8% vs. 0%, p = 0.02). Additionally, the use of a cap was associated with a significantly greater depth of small bowel insertion (191.9 cm vs. 156.2 cm, p = 0.01). There was one perforation in the group without a cap, successfully treated with clip placement, and no adverse events in the cap group. CONCLUSIONS: The use of a transparent cap during SBE performed for the evaluation of obscure gastrointestinal bleeding may be an important, safe augmentation to standard SBE techniques.


Assuntos
Endoscópios Gastrointestinais , Hemorragia Gastrointestinal/diagnóstico , Enteroscopia de Balão Único/instrumentação , Idoso , Desenho de Equipamento , Feminino , Hemorragia Gastrointestinal/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Missouri , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
11.
J Physiol ; 596(15): 3411-3424, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29178568

RESUMO

KEY POINTS: Balloon-assisted enteroscopy (BAE) is an emerging standard procedure by utilizing distensible balloons to facilitate deep endoscopy in the small and large intestine. Sporadic cases of bacteraemia were found after BAE. Balloon distension by BAE caused gut tissue hypoxia. The impact of balloon distension-induced hypoxia on intestinal barriers remains unclear. Murine models of BAE by colonic balloon distension showed that short- and long-term hypoxia evoked opposite effects on epithelial tight junctions (TJs). Short-term hypoxia fortified TJ integrity, whereas long-term hypoxia caused damage to barrier function. Our data showed for the first time the molecular mechanisms and signalling pathways of epithelial barrier fortification and TJ reorganization by short-term hypoxia for the maintenance of gut homeostasis. The findings suggest avoiding prolonged balloon distension during BAE to reduce the risk of hypoxia-induced gut barrier dysfunction. ABSTRACT: Balloon-assisted enteroscopy (BAE) is an emerging standard procedure that uses distensible balloons to facilitate deep endoscopy. Intestines are known to harbour an abundant microflora. Whether balloon distension causes perturbation of blood flow and gut barrier dysfunction, and elicits risk of bacterial translocation remains unknown. Our aims were to (1) conduct a prospective study to gather microbiological and molecular evidence of bacterial translocation by BAE in patients, (2) establish a murine model of colonic balloon distension to investigate tissue hypoxia and intestinal barrier, and (3) assess the effect of short- and long-term hypoxia on epithelial permeability using cell lines. Thirteen patients were enrolled for BAE procedures, and blood samples were obtained before and after BAE for paired comparison. Four of the 13 patients (30.8%) had positive bacterial DNA in blood after BAE. Post-BAE endotoxaemia was higher than the pre-BAE level. Nevertheless, no clinical symptom of sepsis or fever was reported. To mimic clinical BAE, mice were subjected to colonic balloon distension. Local tissue hypoxia was observed during balloon inflation, and reoxygenation after deflation. A trend of increased gut permeability was seen after long-term distension, whereas a significant reduction of permeability was observed by short-term distension in the proximal colon. Human colonic epithelial Caco-2 cells exposed to hypoxia for 5-20 min exhibited increased tight junctional assembly, while those exposed to longer hypoxia displayed barrier disruption. In conclusion, sporadic cases of bacteraemia were found after BAE, without septic symptoms. Short-term hypoxia by balloon distension yielded a protective effect whereas long-term hypoxia caused damage to the gut barrier.


Assuntos
Enteroscopia de Balão , Hipóxia , Mucosa Intestinal/metabolismo , Adulto , Idoso , Animais , Células CACO-2 , Feminino , Humanos , Hipóxia/diagnóstico , Hipóxia/metabolismo , Hipóxia/microbiologia , Fígado/microbiologia , Masculino , Camundongos Endogâmicos BALB C , Pessoa de Meia-Idade , Proteínas Quinases Ativadas por Mitógeno/metabolismo , Permeabilidade , Baço/microbiologia , Junções Íntimas/metabolismo
12.
Digestion ; 98(1): 26-32, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29672285

RESUMO

BACKGROUND/AIMS: Endoscopic balloon dilatation (EBD) is an alternative to surgery for strictures in patients with Crohn's disease (CD). The aim of the present study was to clarify the efficacy and safety of EBD for strictures in patients with CD. METHODS: Twenty-six patients with CD who underwent EBD for strictures from August 2008 to November 2015 were followed up after dilatation. Short-term success was defined as the disappearance of obstructive symptoms after technically adequate dilatation was achieved. The short-term success rate of EBD, safety profile of EBD, and cumulative surgery-free and redilatation-free rates were analyzed. RESULTS: Sixty-five EBDs were performed for CD patients in the follow-up period. The short-term success rate was 100% (26/26), and no complications were encountered during this study. Two (7.7%) patients underwent surgery during the observation period. The cumulative surgery-free rate after the initial EBD was 90.3% at both 2 and 3 years. The cumulative redilatation-free rate after the initial EBD was 52.1% at 2 years and 39.1% at 3 years. CONCLUSION: EBD for strictures secondary to CD provides not only short-term success but also long-term efficacy. Although a high redilatation rate is one of the clinical problems of this procedure, EBD is an effective therapy for avoiding intestinal recession in CD -stricture.


Assuntos
Colonoscopia/métodos , Constrição Patológica/terapia , Doença de Crohn/complicações , Dilatação/métodos , Obstrução Intestinal/terapia , Adulto , Idoso , Colonoscopia/efeitos adversos , Colonoscopia/instrumentação , Constrição Patológica/etiologia , Dilatação/efeitos adversos , Dilatação/instrumentação , Feminino , Seguimentos , Humanos , Obstrução Intestinal/etiologia , Masculino , Pessoa de Meia-Idade , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
13.
Clin Gastroenterol Hepatol ; 15(1): 56-62, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27565523

RESUMO

BACKGROUND & AIMS: Previous studies have not found a correlation between fecal level of calprotectin and small bowel Crohn's disease (CD). However, these studies evaluated patients mainly by ileocolonoscopy, which views up to only the terminal ileum rather than entire small intestine. We investigated whether level of fecal calprotectin (FC) is a marker of active CD of the small bowel, identified by balloon-assisted enteroscopy and computed tomography enterography (CTE). METHODS: We performed a prospective study of 123 patients with CD (35 with ileitis, 72 with ileocolitis, and 16 with colitis) evaluated by balloon-assisted enteroscopy from May 2012 through July 2015 at Toho University Sakura Medical Centre in Japan. Patients with strictures detected by balloon-assisted enteroscopy were evaluated by CTE (n = 17). Fecal samples were collected from each patient, and levels of calprotectin were measured; patient demographic variables and medical history were also collected. We developed a CTE scoring system for disease severity that was based on bowel wall thickness, mural hyperenhancement, and engorged vasa recta. The association between level of FC and simple endoscopic index for CD score or CTE was evaluated by using Spearman rank correlation coefficient. RESULTS: Level of FC correlated with the simple endoscopic index for CD score (r = 0.6362, P < .0001), even in patients with only active disease of the small intestine (r = 0.6594, P = .0005). In the 17 patients with strictures that could not be passed with the enteroscope, CTE detected all lesions beyond the strictures as well as areas in the distal side of the strictures. Level of FC correlated with CTE score in these patients (r = 0.4018, P = .0011, n = 63). In receiver operating characteristic analyses, the FC cutoff value for mucosal healing was 215 µg/g; this cutoff value identified patients with healing with 82.8% sensitivity, 71.4% specificity, positive predictive value of 74.3%, negative predictive value of 80.6%, odds ratio of 12.0, and area under the receiver operating characteristic curve value of 0.81. CONCLUSIONS: A combination of measurement of level of FC and CTE appears to be effective for monitoring CD activity in patients with small intestinal CD, including patients with strictures that cannot be passed by conventional endoscopy.


Assuntos
Biomarcadores/análise , Doença de Crohn/patologia , Fezes/química , Intestino Delgado/patologia , Complexo Antígeno L1 Leucocitário/análise , Adolescente , Adulto , Idoso , Enteroscopia de Balão , Doença de Crohn/diagnóstico por imagem , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Adulto Jovem
14.
J Gastroenterol Hepatol ; 32(2): 388-394, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27356264

RESUMO

BACKGROUND AND AIMS: Angioectasias are the most common sources of bleeding in the small bowel. They can be treated using balloon-assisted enteroscopy (BAE). This study aimed to identify the rebleeding rate and associated factors after BAE in patients with small bowel angioectasia bleeding. METHODS: We retrospectively analyzed the records of patients with bleeding due to small bowel vascular lesion in a multicenter enteroscopy database including 1108 BAEs. Finally, in rebleeding analysis, we analyzed 66 patients with angioectasia on the basis of the Yano-Yamamoto classification. Patients who had undergone endotherapy (ET) were divided into ET (n = 45) and non-ET (n = 21) groups. Rebleeding was defined as evidence of bleeding at least 30 days after BAE. RESULTS: Fifty-three patients (80.4%) underwent only one-side enteroscopy. The most common ET was argon plasma coagulation (87.2%). During a mean follow-up duration of 24.5 months, ET and non-ET groups had rebleeding rates of 15.6% and 38.1% (P = 0.059), respectively. Median rebleeding time of ET and non-ET groups was 32.5 and 62 months, respectively. Liver cirrhosis (LC), low platelet count (< 105 /µL), and transfusions were the rebleeding-associated factors in the univariate analysis. In the multivariate analysis, the presence of LC (HR 4.064, 95% CI 1.098-15.045; P = 0.036) was the only independent rebleeding-associated risk factor. CONCLUSIONS: ET using BAE did not significantly affect the rebleeding rate in patients with small bowel angioectasia bleeding. An independent rebleeding risk factor was the presence of LC. Regardless of ET, careful long-term follow-up may be needed, especially in LC patients with small bowel angioectasia bleeding.


Assuntos
Enteroscopia de Balão , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/cirurgia , Intestino Delgado/cirurgia , Estudos Multicêntricos como Assunto , Adulto , Idoso , Enteroscopia de Balão/efeitos adversos , Feminino , Humanos , Cirrose Hepática/complicações , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
15.
BMC Gastroenterol ; 16(1): 98, 2016 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-27549034

RESUMO

BACKGROUND: Roux-en-Y reconstructive surgery excludes the biliopancreatic system from conventional endoscopic access. Balloon-assisted enteroscopy allows therapeutic endoscopic retrograde cholangiopancreatography (ERCP) in these patients, avoiding rescue surgery. The objective of the current study is to compare success and complication rate of double-balloon (DBE) and single-balloon enteroscope (SBE) to perform ERCP in Roux-en-Y patients. METHODS: Seventy three Roux-en-Y patients with suspected biliary tract pathology underwent balloon-assisted enteroscopy in a tertiary-care center. Retrospective analysis of 95 consecutive therapeutic ERCP procedures was performed to define and compare success and complication rate of DBE and SBE. RESULTS: Male-female ratio was 28/45 with a mean age of 58 ± 2 years. 30 (32 %) procedures were performed with DBE and 65 (68 %) with SBE. Overall ERCP success rate was 73 % for DBE and 75 % for SBE (P = 0.831). Failure was due to inability to reach or cannulate the intact papilla or bilioenteric anastomosis. Success rate was significantly higher when performed at the bilioenteric anastomosis (80 % success in 56 procedures) or at the intact papilla in short-limb Roux-en-Y (80 % in 15 procedures) as compared to the intact papilla in long-limb (58 % in 24 procedures; P = 0.040). Adverse event rates were 10 % (DBE) and 8 % (SBE) (P = 0.707) and mostly dealt with conservatively. CONCLUSIONS: ERCP after Roux-en-Y altered small bowel anatomy is feasible and safe using both DBE and SBE. Both techniques are equally competent with high success rates and acceptable adverse events rates. ERCP at the level of the intact papilla in long limb Roux-en-Y is less successful as compared to short-limb or bilioenteric anastomosis.


Assuntos
Anastomose em-Y de Roux , Colangiopancreatografia Retrógrada Endoscópica/métodos , Enteroscopia de Duplo Balão , Intestino Delgado/cirurgia , Enteroscopia de Balão Único , Adulto , Idoso , Idoso de 80 Anos ou mais , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Enteroscopia de Duplo Balão/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Enteroscopia de Balão Único/efeitos adversos
16.
Curr Gastroenterol Rep ; 18(6): 28, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27098815

RESUMO

Deep enteroscopy allows for the diagnosis and treatment of small bowel disorders that historically required operative intervention. There are a variety of endoscopic platforms using balloons and rotational overtubes to facilitate small bowel intubation and even allow for total enteroscopy. Obscure gastrointestinal bleeding is the most common indication for deep enteroscopy. By visualizing segments of the small bowel not possible through standard EGD or push enteroscopy, deep enteroscopy has an established high rate of identification and treatment of bleeding sources. In addition to obscure bleeding, other common indications include diagnosis and staging of Crohn's disease, evaluation of findings on capsule endoscopy and investigation of possible small bowel tumors. Large endoscopy databases have shown deep enteroscopy to be not only effective but safe. Recent research has focused on comparing the diagnostic rates, efficacy, and total enteroscopy rates of the different endoscopic platforms.


Assuntos
Endoscopia Gastrointestinal/métodos , Enteropatias/diagnóstico , Intestino Delgado , Endoscopia por Cápsula/métodos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Enteroscopia de Duplo Balão/métodos , Hemorragia Gastrointestinal/etiologia , Humanos
17.
Dig Endosc ; 28(4): 443-449, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26688319

RESUMO

BACKGROUND AND AIM: Previous studies addressed the outcome of balloon-assisted enteroscopy (BAE) were based on its early experience. This procedure is operator-dependent and requires learning curve. Therefore, the accumulated BAE experience over the last decade might affect its pattern of use and outcome. In order to evaluate the changes of BAE practice over time, we compared the indications, diagnostic yield, and complication rate between the early and late stages of BAE implementation. METHODS: This multicenter study analyzed BAE-related factors of 1,108 BAE procedures performed in 860 patients and compared the BAEs performed in early stage (Jan. 2004-Aug. 2008, n=543 procedures) to those performed in late stage (Sept. 2008-Feb. 2013, n=565 procedures). RESULTS: The most common indication for BAE was obscure gastrointestinal bleeding (58.3%). In the early stage, BAE to assess unexplained symptoms/signs was more common (18.8% vs. 9.7%), whereas BAE to confirm abnormal findings of imaging studies was more common in late stage (9.4% vs. 18.8%, P<0.001). Overall diagnostic yield of BAE was 74.6% (95% CI, 72.0%-77.1%). There was no significant difference in the diagnostic yield between the early and late stages (72.2% vs. 77.0%, P=0.073). BAE-associated complications occurred in 12 procedures (1.1%; 95% CI, 0.6%-1.9%). The complication rate decreased significantly in late stage compared to that during early stage (1.8% vs. 0.4%, P=0.020). CONCLUSIONS: BAE is a safe and useful tool for the diagnosis and management of small bowel disease. With time, the indications for BAE have become more specific and the BAE-associated complication rate has decreased. This article is protected by copyright. All rights reserved.

18.
Dig Dis Sci ; 60(12): 3716-20, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26224642

RESUMO

BACKGROUND AND AIMS: Within the community, patients with positive capsule endoscopy (CE) are often referred to centers performing balloon-assisted enteroscopy. There is limited data evaluating the concordance and diagnostic/therapeutic yield of CE performed in the community versus CE conducted at institutions experienced with enteroscopy. The primary aim of this retrospective study was to evaluate the concordance between CE and SBE after CE was performed either in the community or at our tertiary care center. METHODS: A total of 141 patients were analyzed after selecting patients undergoing evaluation of obscure GI bleeding from January 2010 to May 2014. Forty-seven CE were performed inside and the remaining 94 CE were performed at outside institutions prior to single-balloon enteroscopy at our institution. Agreement beyond chance was evaluated using kappa coefficient. A p value <5% was considered significant. RESULTS: The most frequent findings on CE were vascular lesions in 39 patients (41.5%) within the referral group and 23 within inside patients (48.9%), followed by active bleeding/clots in 23 patients (24.5%) and in 14 patients (29.8%) respectively. There was a fair degree of concordance in the referral group for vascular lesions 0.23 (0.03-0.42) compared to a good degree in the inside group 0.65 (0.44-0.87). Fair agreement was found looking at ulcers within the referral group 0.29 (0.06-0.65) compared to a moderate agreement in the inside group 0.55 (0.17-0.94). CONCLUSIONS: Degree of concordance for vascular lesions and ulcers was significantly higher for patients undergoing CE at our institution compared to those referred from the community. Patients referred to tertiary care centers for balloon-assisted enteroscopy may benefit from advanced endoscopists re-reading the capsule findings or even potentially repeating CE in hemodynamically stable patients if the study is not available.


Assuntos
Endoscopia Gastrointestinal/métodos , Hemorragia Gastrointestinal/diagnóstico , Centros de Atenção Terciária , Idoso , Idoso de 80 Anos ou mais , Endoscopia Gastrointestinal/instrumentação , Feminino , Hemorragia Gastrointestinal/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Encaminhamento e Consulta , Estudos Retrospectivos , Fatores de Risco
19.
Dig Endosc ; 27(1): 82-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25040667

RESUMO

BACKGROUND AND AIM: A limited number of endoscopic retrograde cholangiopancreatography (ERCP) accessories are compatible with the conventional single-balloon enteroscope (SBE) because of the latter's dimensions. The aim of the present study was to assess the utility of a prototype SBE that has a shorter working length and a wider channel than the conventional SBE. METHODS: ERCP procedures carried out between January 2012 and July 2013 using the short SBE prototype were reconstructions such as Billroth II (B-II), post-gastrectomy with Roux-en-Y (RY-G), and post-choledochojejunostomy with Roux-en-Y (RY-CJ). We retrospectively analyzed the rate of reaching the blind end of the intestine, the diagnostic success rate, the interventional success rate, and the frequency of related complications. RESULTS: Twenty-seven ERCP procedures on 18 patients analyzed comprised two B-II, 15 RY-G, and 10 RY-CJ reconstructions. With a mean procedure time of 56 min (range 40-150 min), the rate of reaching the blind end, the diagnostic success rate, and the interventional success rate were 24/27 (89%), 20/27 (74%), and 19/27 (70%), respectively. There were no major ERCP-related complications in any patient. CONCLUSIONS: The prototype short-type SBE appears safe and effective for use in ERCP, and is compatible with conventional endoscopy accessories.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/instrumentação , Endoscópios Gastrointestinais , Trato Gastrointestinal/patologia , Complicações Pós-Operatórias/cirurgia , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Trato Gastrointestinal/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Estudos Retrospectivos
20.
Dig Endosc ; 26(4): 545-51, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24528293

RESUMO

BACKGROUND AND AIM: Endoscopic balloon dilation (EBD) is an alternative to surgery for small bowel strictures of patients with Crohn's disease (CD). However, little is known about the long-term efficacy of EBD. The aim of the present study was to clarify the long-term outcome of EBD for small bowel strictures in patients with CD. METHODS: Subjects comprised 65 patients with CD who underwent EBD for small intestinal strictures and were followed up for at least 6 months. All subjects had obstructive symptoms as a result of small bowel strictures. Short-term success was defined as technical success and the disappearance of obstructive symptoms. The short-term success rate of EBD, its safety profile, the cumulative surgery-free rate and the cumulative redilation-free rate were investigated. RESULTS: Short-term success rate was 80.0% (52/65). Complications were encountered in six of the 65 patients (9.2%). Seventeen patients (26.2%) underwent surgery during the observation period of this study. Cumulative surgery-free rate after initial EBD was 79% at 2 years and 73% at 3 years, respectively. EBD successful cases showed significantly higher surgery-free rates than unsuccessful cases (P < 0.0001). In 52 of the successful cases, the cumulative redilation-free rate after initial EBD was 64% at 2 years and 47% at 3 years, respectively. CONCLUSION: EBD for small bowel strictures secondary to CD provides not only short-term success but also long-term efficacy. However, the high redilation rate is one of the clinical problems of this procedure.


Assuntos
Doença de Crohn/complicações , Endoscopia Gastrointestinal/métodos , Obstrução Intestinal/terapia , Intestino Delgado , Adulto , Dilatação/métodos , Feminino , Humanos , Obstrução Intestinal/etiologia , Obstrução Intestinal/patologia , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA