Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Ophthalmol ; 33(3): 1390-1397, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36567614

RESUMO

PURPOSE: To compare the performance of Tecnis Eyhance ICB00 with Tecnis PCB00 IOL for far, intermediate, and near vision, in patients after bilateral cataract surgery. SETTINGS: This study was done at Geneva University Hospitals. DESIGN: This is a retrospective study of 224 eyes that underwent cataract between May 2019 and June 2020. METHODS: Visual acuity was assessed from month 1 to 12 after surgery for distance, intermediate and near visual acuity, by the same optometrist, which was blind regarding the type of IOL. The patients answered to a quality of life questionnaire. Patients were excluded for: monocular surgery, macular disease, other IOL type, or inability to reach 20/20 visual acuity in both eyes without correction. RESULTS: One hundred and fifty-two eyes were excluded. Three groups were then analyzed: PCB00 group (38 eyes), ICB00 group (22 eyes), and mismatch group (12 eyes). Monocular visual acuities (CIVA, UNVA and CNVA, in logMAR) were higher in the ICB00 group than the PCB00 group (respectively 0.3 vs 0.4, p = 0.0033; 0.3 vs 0.4, p = 0.0408; 0.3 vs 0.4, p = 0.0039). Binocular visual acuities, CIVA and CNVA were higher in the ICB00 group than the PCB00 group (0.2 vs 0.4, p = 0.0061; 0.15 vs 0.3, p = 0.018). This mirrored the findings of the quality of life questionnaire. There was no significant difference between PCB00 and mismatch groups. CONCLUSIONS: the Tecnis Eyhance was more effective for intermediate and near vision. The central defocus of the lens might help patients achieve spectacle independence and better quality of life.


Assuntos
Catarata , Lentes Intraoculares , Miopia , Facoemulsificação , Humanos , Implante de Lente Intraocular , Qualidade de Vida , Estudos Retrospectivos , Desenho de Prótese , Satisfação do Paciente , Visão Binocular
2.
Eur J Ophthalmol ; : 11206721231207470, 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37849296

RESUMO

PURPOSE: This study investigates the relationship between pupil size during biometry examinations and the chord mu value in candidates for cataract surgery. METHODS: Retrospective analysis of ocular biometry measurements was performed on consecutive cataract surgery candidates above 50 years of age, examined between 2018 and 2020 at a single tertiary referral center. Statistical analysis assessed the association between pupil size and the chord mu value. The population was categorized into groups based on pupil size, and an analysis was conducted on the barycenter positions of the iris and pupil center for each group. RESULTS: The analysis included 2877 patients. A weak positive correlation was observed between the chord mu value and pupil size using Pearson's test (r = 0.160, p < 0.01). Group stratification by pupil size indicated temporal and inferior shifts in pupil center barycenter as pupil size increased, reflecting asymmetrical pupil dilation during mydriasis. A moderate positive correlation between the chord mu value and chord alpha value was identified (Pearson's test, r = 0.641, p < 0.01). As expected, no correlation was found between chord alpha value and pupil size. CONCLUSIONS: Chord mu values were higher in patients with mydriatic pupils, likely due to asymmetric pupil dilation and center displacement. Evaluating chord mu values requires considering pupil status and conducting biometry under standardized lighting to prevent misinterpretation caused by pharmacological dilation. This caution is crucial to avoid erroneously excluding eligible patients from multifocal IOL implants. Alternatively, the chord alpha value could serve as a more appropriate alternative in such scenarios.

3.
Eur J Ophthalmol ; : 11206721231220331, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38112344

RESUMO

PURPOSE: To present the profile of a large cohort of children with persistent fetal vasculature (PFV) and identify their predictors of poor visual outcome in a tertiary eye hospital in Saudi Arabia. METHODS: This was a single-center study. Medical records of children diagnosed with persistent fetal vasculature between January 1990 and January 2020 at King Khaled Eye Specialist Hospital (KKESH), Riyadh, were reviewed. Data were collected on PFV type, presenting features, management, and visual acuity. Poisson regression with robust error variance was used to identify the predictors of poor visual outcome. RESULTS: Data of 175 eyes of 170 children with PFV were analyzed. Most had unilateral disease (n = 165, 96.2%), and over half of them (57.1%) were males. The main presenting complaints were leukocoria (n = 126, 72.0%), followed by smaller eye (n = 36, 20.6%), poor vision (n = 15, 8.6%), and strabismus (n = 13, 7.4%). Anterior, posterior, and combined PFV were present in 30.9%, 10.9%, and 58.3% eyes, respectively. In eyes with measurable visual acuity (n = 124), BCVA at the last follow-up was ≥20/100, <20/100-20/400, CF/HM and LP/NLP in 11 (8.9%), 32 (25.8%), 43 (34.7%), and 38 (30.6%) eyes, respectively. In the multivariable poisson regression analysis, eyes with posterior PFV were approximately two times more likely to have a BCVA of CF or worse than those with anterior PFV (Adjusted incidence ratio: 1.82 (95%: 1.23, 2.70; P = 0.003). Compared with eyes with primary or secondary IOL implantation, aphakic eyes or those with no cataract surgery were significantly more likely to have BCVA of CF or worse (adjusted incidence ratio: 1.84 [95%: 1.18, 2.86], p = 0.007 and adjusted incidence ratio: 1.64 [95%: 1.08, 2.50], p = 0.020, respectively). CONCLUSIONS: The prognosis of PFV varies depending on the severity of the disease. Patients with posterior PFV had worse visual outcome than anterior or combined type. Whether primary or secondary, IOL implantation increases the probability of having BCVA better than CF.

4.
Eur J Ophthalmol ; : 11206721221144928, 2022 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-36529873

RESUMO

BACKGROUND: To assess the visual quality and the tolerance to low refractive errors of two trifocal intraocular lenses (IOL) with different amounts of spherical aberration (SA). METHODS: The study included patients having bilateral implantation of the AcrySof® IQ PanOptixTM (aberration-correcting) or the RayOneTM (aberration-free) Trifocal IOL. Three months after the surgery patients underwent: monocular/binocular and uncorrected/corrected distance visual acuity (VA) and binocular defocus curves. Binocular contrast sensitivity (CSF) and subjective halo perception were assessed with the best distance correction (CDVA), with a positive defocus of + 0.50D and with a negative defocus of -0.50D. Patient's satisfaction was evaluated with the Catquest9-SF questionnaire. RESULTS: This study included 54 eyes (28 with PanOptix and 26 with RayOne) of 27 patients. Both groups achieved corrected/uncorrected and monocular/binocular distance VA values better than 0.0 logMAR (1.0 decimal) with no statistically significant differences between them (p > 0.05 for all cases). Defocus curves showed a VA of 0.1 logMAR or better between -2.5 and + 1.0D with no differences between groups (p > 0.05 at all distances). Overall CSF values remained stable under the induced residual refractions for both groups. The halo effect remained stable for the PanOptix group but increased with myopization in the RayOne group (p = 0.02). The questionnaire showed high rates of patient's satisfaction with no differences between groups. CONCLUSION: Both lenses showed overall good visual outcomes and offered high rates of patient's satisfaction. Moreover, in normal patients with trifocal IOLs, the combination of residual refractive errors and certain amounts of SA may increase some visual disturbances.

5.
Eur J Ophthalmol ; 31(5): 2370-2376, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33054421

RESUMO

PURPOSE: To compare the accuracy of 11 intraocular lens (IOL) power calculation formulas (SRK-T, Hoffer Q, Holladay I, Haigis, Holladay II, Olsen, Barrett Universal II, Hill-RBF, Ladas Super formula, EVO and Kane). SETTING: Private university hospital (QuironSalud, Madrid, Spain). DESIGN: Retrospective case series. METHODS: Data were compiled from 481 eyes of 481 patients who had undergone uneventful cataract surgery with IOL insertion. Preoperative biometric measurements were made using an IOL Master® 700. Respective ULIB IOL constants (http://ocusoft.de/ulib/c1.htm) for each of 4 IOL models implanted were used to calculate the predictive refractive outcome for each formula. This was compared with the actual refractive outcome determined 3 months postoperatively. The primary outcome was mean absolute prediction error (MAE). The study sample was divided according to axial length (AL) into three groups of eyes: short (⩽22.00 mm), normal (22.00-25.00 mm) and long (⩾25.00 mm). RESULTS: The Barrett Universal II and Haigis formulas yielded the lowest MAEs over the entire AL range (p < .01, except EVO) as well as in the long (p < .01, all formulas) and normal (p < .01, except Haigis, Holladay II, Olsen and LSF) eyes. In the short eyes, the lower MAEs were provided by Haigis and EVO (p < .01 except Hoffer Q, SRK/T and Holladay I). CONCLUSIONS: Barrett Universal II was the most accurate for IOL power calculation in the normal and long eyes. For short eyes, the formulas Haigis and EVO seem best at predicting refractive outcomes.


Assuntos
Lentes Intraoculares , Facoemulsificação , Comprimento Axial do Olho , Biometria , Humanos , Implante de Lente Intraocular , Óptica e Fotônica , Refração Ocular , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA