RESUMO
The onset of the COVID-19 pandemic confronted medicine with several difficulties, including a lack of specific therapeutic options, the absence of out-of-hospital testing facilities to diagnose the condition, and the sudden extraordinary need for intensive medical care that overwhelmed most hospitals. Early in the pandemic, many physicians recognized that using antibodies harvested from recovering patients was a treatment that had a proven track record for many diseases and that might be used to manage the disease at least as a stopgap until more specific medicines for COVID-19 were developed. But using convalescent plasma raised many additional complications, most especially the logistics that needed to be put in place to collect and distribute such plasma. Unlike drugs ordered from a pharmacy, plasma and other blood products are procured by a complex process that depends intensely on interaction with the public, the provider of all blood products that are directly provided to patients. Blood components such as convalescent plasma, intended to be used immediately without major processing, are entirely supplied by donations from the public. This form of treatment can therefore benefit from patient advocates, especially if they are experienced in solving problems of logistics and in the process of matching supply to demand that is more commonly encountered in the business world than in medicine. In this chapter, one patient advocate, Chaim Lebovits, describes the process of mobilizing the population, interacting with blood banks and hospitals, and successfully channeling thousands of units of plasma from volunteers recovering from COVID-19 to patients in hospitals. Starting in New York City in early 2020 and initially working with communities with which Mr. Lebovits was familiar, the efforts steadily spread across many parts of the US. The model described here, which uses patient advocates to serve as a link between patients, blood banks, and hospitals in the service of gathering and distributing high-titer convalescent plasma to patients is likely to be relevant to the next pandemic.
RESUMO
BACKGROUND: Special Forces (SF) teams operate in remote environments with limited medical support. As a result, they may need to rely on buddy transfusions to treat bleeding teammates. Considering that 450 mL has no direct impact on their combat performances, it might be tempting to take more blood from a compatible donor to save a hemorrhaging teammate. This study investigates the effect of a 900 mL blood donation on SF operator performance and recovery time following this donation. STUDY DESIGN AND METHODS: Participants underwent a multifactorial assessment including measures of physiological parameters, vigilance, and physical performance. Results from the day of blood donation were compared with baseline values obtained 1 week earlier (i.e., immediate effect), as well as repeated testing at 7, 14, and approximately 30 days after blood donation (i.e., recovery period). RESULTS: Hemoglobin levels and heart rate were affected by giving blood. The participants also experienced a significant decrease in physical performance of more than 50% immediately after blood donation. Recovery was slow over the following weeks, remaining significantly different from baseline until full recovery around day 30. However, participants were still able to respond to a simple stimulus and adjust their response, if necessary, even immediately after donating blood. DISCUSSION: A 900 mL blood donation greatly affects the physical fitness of SF operators. A donation may be worthwhile if it is the only life-saving procedure available and does not endanger the donor's life. The donor would then become a patient and unable to complete the mission.
Assuntos
Doação de Sangue , Doadores de Sangue , Humanos , Transfusão de SangueRESUMO
BACKGROUND: Today, with wars raging in Ukraine and the Middle East, the demand for blood is high. Despite this, few companies produce the necessary equipment to draw, store, and transfuse whole blood. This study evaluated the safety and performance of a 3D printed bottle cap in conjunction with a water bottle and some available consumables to draw and store fresh whole blood. STUDY DESIGN AND METHODS: Bags of saline, and freshly donated whole blood, was transferred to the water bottle through a 3D printed bottle cap and stored for 72 h. An identical setup, transferring saline to a Terumo blood collection bag was used as control. Performance and safety were evaluated by calculating infusion rate and observing for backflow, respectively. The blood was also tested for hemolysis and bacterial growth at four sampling points. RESULTS: The cap-and-bottle setup was faster than control in terms of flow rate when transferring saline (1.53 vs. 1.81 mL/s, p < .001), and non-inferior to saline control when transfusing blood (1.53 vs. 1.49 mL/s, p = .641). We did not observe any risks of causing the donor iatrogenic harm, and there was no evidence of increased hemolysis. However, there were traces of bacterial contamination in three of six bottles. CONCLUSION: This study indicates that drawing blood is both feasible and safe, utilizing a 3D printed cap and bottle setup. Flow rate was faster than control, and mechanical properties of the blood were not affected. We were unable to determine the source of bacterial contamination in the blood.
Assuntos
Preservação de Sangue , Impressão Tridimensional , Humanos , Preservação de Sangue/métodos , Desinfecção/métodos , Hemólise , Estudo de Prova de Conceito , Doadores de SangueRESUMO
BACKGROUND AND OBJECTIVES: Solid organ transplant surgeries including liver transplants constitute a substantial risk of bleeding complications and given frequent national blood shortages, supporting D-negative transplant recipients with D-negative red blood cell products perioperatively can be difficult for the transfusion services. This study was designed to compare the incidence of alloimmunization after D-mismatched red cell transfusions between patients with and without a history of solid organ transplant at a single tertiary care hospital. The patients undergoing solid organ transplants are on strong immunosuppressive regimens perioperatively to help reduce the risk of rejection. We hypothesized that the use of these immunosuppressive agents makes these patients very less likely to mount an immune response and form anti-D antibodies when exposed to the D-positive red blood cell products perioperatively. STUDY DESIGN AND METHODS: At our center, D-negative patients who received ≥1 unit of D-positive red blood cell products were identified using historical transfusion records. Antibody testing results were examined to determine the incidence of the formation of anti-D and any other red cell alloantibodies after transfusion and these results were compared between patients with and without a history of solid organ transplant. RESULTS: We were able to identify a total of 22 patients over 10 years with D-negative phenotype who had undergone a solid organ transplant and had received D-positive red blood cell products during the transplant surgeries. We also identified a second group of 54 patients with D-negative phenotype who had received D-positive red blood cell products for other indications including medical and surgical. A comparison of the data showed no new anti-D formation among patients with a history of D mismatched transfusion during solid organ transplant surgeries. CONCLUSION: Among our limited study population, we observed a very low likelihood of D alloimmunization among solid organ transplant recipients. A larger, prospective study could help further evaluate the need for prophylactic D matching for red cell transfusions during solid organ transplant surgeries.
Assuntos
Transfusão de Sangue , Transplante de Órgãos , Imunoglobulina rho(D) , Humanos , Estudos Prospectivos , Incidência , Eritrócitos , IsoanticorposRESUMO
BACKGROUND: Poor disinfection is the main cause of blood contamination, so its elimination is key to limiting the entry of bacteria into the collection system. With the advancement of antiseptic technology, antiseptics with sterile, disposable applicators are now available. AIM: To evaluate in situ two antiseptics (with and without applicators) for blood banks and to demonstrate in vitro antiseptic activity on bacterial biofilms of importance in transfusion medicine. METHODS: Antiseptic A (2% sterile solution of chlorhexidine gluconate/70% isopropyl alcohol provided with applicator) and bulk antiseptic B (10% povidone-iodine) were evaluated. The deferred blood donor arms were subjected to disinfection with antiseptics A and B and the contralateral arms were cultured to determine the baseline bacterial load (control). Antiseptic activity was assessed by ANOVA and logaritmic reduction values (LRV) and percentage reduction values (PRV) were calculated. Finally, the in vitro activity of antiseptic A was analyzed by confocal laser scanning microscopy (CLSM) on biofilm models. RESULTS: Prior to disinfection tests, commensal and clinically important bacteria were identified; antiseptic A showed post-disinfection bacterial growth rates of zero compared to controls (p < 0.0001). The frequency of bacterial growth with antiseptic B was 74%. A significant difference was identified between both antiseptics, where antiseptic A showed higher activity (p < 0.5468). LRV and PRV were 0.6-2.5/100% and 0.3-1.7/66.7-99.7% for antiseptics A and B, respectively. Through CLSM, disinfectant A (without applicator) showed lower in vitro antiseptic activity on the tested biofilms at the exposure times recommended by the manufacturer. CONCLUSIONS: Sterile solution of chlorhexidine gluconate/isopropyl alcohol with applicator showed advantages disinfection in deferred blood donors over povidone-iodine.
Assuntos
Anti-Infecciosos Locais , Clorexidina/análogos & derivados , Humanos , Anti-Infecciosos Locais/farmacologia , Povidona-Iodo/farmacologia , 2-Propanol , Bancos de SangueRESUMO
Knowledge regarding the profile of eligible blood donors presenting positive results in laboratory screening is essential for reducing transfusion-transmitted human immunodeficiency virus (HIV), hepatitis B virus (HBV) and hepatitis C virus (HCV). Our study aimed to evaluate the prevalence, incidence, predictor variables and residual risk (RR) of HIV/HBV/HCV in blood bags donated in Minas Gerais, Brazil. This study analysed data retrieved from the records of a large blood bank relating to donations collected at multiple centres within the period 2012-2018, during which 1 991 120 blood bags were screened using immunoassays and nucleic acid tests (NATs). Multilevel modelling was used to investigate the association between sex, civil status and age group with HIV/HBV/HCV. RR was estimated from the incidence values (restricted to negative and positive tests within the study period) and window periods for infections. The prevalence in first time donors, incidence and RR of HCV (223.73 cases per 100 000; 54.84 per 100 000 persons-year and 1.6527 per 100 000, respectively) were higher than those of HIV (172.65 cases per 100 000; 28.25 per 100 000 persons-year and 0.8514 per 100 000) and HBV (168.17 cases per 100 000; 18.54 per 100 000 persons-year and 0.5588 per 100 000). The odds of acquiring infection were greater in male, single and older donors. Sixteen donors were identified as seronegative and NATs+ during the 7-year span of the study. Our study has clarified some spatiotemporal trends regarding HIV/HBV/HCV infections in donated blood in Brazil. The results will contribute to the formulation of directives addressed to high-risk donors.
Assuntos
Infecções por HIV , Hepatite B , Hepatite C , Masculino , Humanos , Feminino , Incidência , Hepatite B/epidemiologia , Brasil/epidemiologia , Doadores de Sangue , Prevalência , Fatores de Risco , Hepatite C/epidemiologia , Vírus da Hepatite B , Infecções por HIV/epidemiologia , HepacivirusRESUMO
OBJECTIVES: Our objective was to compare the measurement of residual white blood cell (rWBC) and residual red blood cell (rRBC) counts in blood products using the XN Blood Bank mode and the laboratory standard operating procedures for manual counts. In addition, to compare the whole blood complete blood count (CBC) values of blood donors and the quality of blood products using the Sysmex XN analyser versus the XS-1000i analyser. MATERIALS AND METHODS: For blood donors, 190 samples from blood or apheresis donors were analysed on both the Sysmex XS-1000i and XN-1000 analysers and the mean values of six CBC parameters were compared: the white blood cell count (WBC), the red blood cell count (RBC), haemoglobin (HGB), haematocrit (HCT), the mean corpuscular volume (MCV), the platelet count (PLT). For blood products, 164 samples were collected: 13 Plasma products - whole blood, 9 Plasma products - apheresis, 36 RBC concentrates - whole blood, 30 PLT concentrates - buffy coats, 36 PLT concentrates - buffy coats - pooled and 55 PLT concentrates - apheresis. RESULTS: All CBC parameters of the blood donors tested showed similar performance, with excellent correlation coefficients (r) ranging from 0.821 to 0.995. The majority of the blood products did not have a quantifiable number of residual cells, meaning the number of rWBC and rRBC, if present, was below the limit of quantitation (LoQ) of the different methods. rWBC were detected by Blood Bank mode in Plasma products - whole blood with a mean rWBC of 0.012 × 109 /L and in PLT concentrates - buffy coats with a mean rWBC of 0.19 × 109 /L. The correlation coefficient in both analysers for all three parameters (HGB, HCT, RBC) in RBC concentrates - whole blood was excellent, ranging from 0.95 to 0.99. For platelet count, r ranged from 0.98 to 0.99. CONCLUSION: The XN-Series analyser, equipped with a Blood Bank mode, demonstrated reliable performance when used for blood donor evaluation, rWBC enumeration and measurement of end blood products.
Assuntos
Bancos de Sangue , Doadores de Sangue , Humanos , Contagem de Células Sanguíneas/métodos , Contagem de Plaquetas , EritrócitosRESUMO
INTRODUCTION: A radical paradigm shift in the treatment of premature infants failing conventional treatment is to recreate fetal physiology using an extracorporeal Artificial Placenta (AP). The aim of this study is to evaluate the effects of changing fetal hemoglobin percent (HbF%) on physiology and circuit function during AP support in an ovine model. METHODS: Extremely premature lambs (n = 5) were delivered by cesarean section at 117-121 d estimated gestational age (EGA) (term = 145d), weighing 2.5 ± 0.35 kg. Lambs were cannulated using 10-14Fr cannulae for drainage via the right jugular vein and reinfusion via the umbilical vein. Lambs were intubated and lungs were filled with perfluorodecalin to a meniscus with a pressure of 5-8 cm H2O. The first option for transfusion was fetal whole blood from twins followed by maternal red blood cells. Arterial blood gases were used to titrate AP support to maintain fetal blood gas values. RESULTS: The mean survival time on circuit was 119.6 ± 39.5 h. Hemodynamic parameters and lactate were stable throughout. As more adult blood transfusions were given to maintain hemoglobin at 10 mg/dL, the HbF% declined, reaching 40% by post operative day 7. The HbF% was inversely proportional to flow rates as higher flows were required to maintain adequate oxygen saturation and perfusion. CONCLUSIONS: Transfusion of adult blood led to decreased fetal hemoglobin concentration during AP support. The HbF% was inversely proportional to flow rates. Future directions include strategies to decrease the priming volume and establishing a fetal blood bank to have blood rich in HbF.
RESUMO
Umbilical cord blood is a rich source of hematopoietic stem cells that has been used for transplantation for over 30 years, especially when there is no compatible hematopoietic stem cell donor available. Its use has decreased more recently, since the development of methods to improve haploidentical transplants has allowed the use of mobilized peripheral blood as a source of hematopoietic stem cells. Public cord blood banks collect, process and store cord blood samples from voluntary donations. In addition, many public banks are involved in research to enhance hematopoietic stem cell therapies and develop new treatments for haematological and genetic diseases. The COVID-19 pandemic, which emerged in 2019, has had a profound and wide-ranging impact on human health and treatment. The area of hematopoietic stem cell transplantation was deeply affected by reductions in bone marrow, peripheral blood and cord blood donations; logistical challenges; exposure of healthcare workers and other challenges. The present study reviews the impact of the COVID-19 pandemic on cord blood banking and transportation around the world with a special focus on Brazil.
Assuntos
Bancos de Sangue , COVID-19 , Transplante de Células-Tronco de Sangue do Cordão Umbilical , Sangue Fetal , Pandemias , SARS-CoV-2 , Humanos , COVID-19/epidemiologia , Sangue Fetal/citologia , SARS-CoV-2/isolamento & purificação , Brasil/epidemiologia , Doadores de SangueRESUMO
INTRODUCTION: In this report, we describe a training program in emergency whole blood collection and transfusion for medical students at the University of Bergen. The overall aim of the program is to improve the availability of early balanced blood transfusion for the treatment of patients with life-threatening bleeding in rural health care services. STUDY DESIGN AND METHODS: The voluntary training program provides the knowledge needed to practice emergency whole blood transfusions and understand the system for emergency whole blood collection in the framework of a civilian walking blood bank (WBB). It includes theoretical and practical sessions. In-person teaching and web-based learning resources are provided. An anonymous survey of the students attending the training course in the autumn of 2022 and spring 2023 was performed. RESULTS: 128 of 178 students participated in the practical training. 88 of 128 (69%) responded to the survey. 82 (93%) performed blood typing, 71 (81%) performed donor interviews, 61 (69%) partially performed whole blood collection (up to blood in bag) and 27 (30%) participated in complete whole blood collection and performed autologous reinfusion. No complications occurred during training. The students reported that the training course increased their understanding of how to ensure access to emergency blood transfusion by the use of a WBB. DISCUSSION: Structured theoretical and practical training in emergency whole blood collection and emergency transfusion is feasible and of interest to medical students. A multidisciplinary approach to student training in emergency whole blood collection and transfusion should be considered.
Assuntos
Transfusão de Sangue , Estudantes de Medicina , Humanos , Bancos de Sangue , Tipagem e Reações Cruzadas Sanguíneas , Transfusão de Sangue/métodos , Hemorragia , Transfusão de Componentes SanguíneosRESUMO
BACKGROUND AND OBJECTIVES: A spectrum of blood-borne infectious agents may be transmitted through transfusion of blood components from asymptomatic donors. Despite the persistence of polyomaviruses in blood cells, no studies have been conducted in Argentina to assess the risk of transfusion infection. MATERIALS AND METHODS: We investigated BKPyV and JCPyV in 720 blood donors, using polymerase chain reaction (PCR) for a region of T antigen common to both viruses. Positive T-antigen samples were subjected to two additional PCR assays targeting the VP1 region. Viral genotypes were characterized by phylogenetic analysis. RESULTS: Polyomaviruses were detected in 1.25% (9/720) of the blood samples selected; JCPyV was identified in 0.97% (7/720) and BKPyV in 0.28% (2/720) of them. Phylogenetic analysis showed that the JCPyV sequences clustered with 2A genotype and Ia of BKPyV. CONCLUSION: This study describes for the first time the prevalence of polyomavirus DNA in blood donors of Córdoba, Argentina. The polyomavirus DNAemia in healthy populations suggests that those viruses are present in blood components eligible for transfusion. Therefore, the epidemiological surveillance of polyomavirus in blood banks might be incorporated into haemovigilance programmes, to determine the infectious risk and implement newer interventions to ensure the safety of blood supplies, if required.
Assuntos
Vírus BK , Vírus JC , Infecções por Polyomavirus , Polyomavirus , Humanos , Polyomavirus/genética , Vírus JC/genética , Vírus BK/genética , Doadores de Sangue , Argentina/epidemiologia , Filogenia , Infecções por Polyomavirus/epidemiologiaRESUMO
INTRODUCTION: The Colombian National Institute of Health administers the National Information System of Haemovigilance (SIHEVI-INS). Today, SIHEVI-INS constitutes a national blood donor and recipient database, which contains a national deferred donor registry (DDR), allowing blood banks to take acceptance or rejection decisions of a potential donor in real time. The study aimed to determine the rate of people who have made more than one whole blood donation monthly in Colombia, violating the national guideline of intervals between donations (three months for men and four for women), since DDR implementation. METHODS: We detected the unique personal identification number of people who, in 30 calendar days, made more than one whole blood donation at any of the 83 blood banks set up in Colombia. There were three comparison periods: 01/01/2018-08/31/2019 (launch of SIHEVI-INS and first national feedback); 09/01/2019-12/31/2020 (second feedback) and 01/01/2021-09/30/2022 (massive incorporation of web services). RESULTS: For the first period, blood banks accepted 18.0 donations per 1000 people. There was a rate of 28.8 people/10,000 donations who had donated whole blood twice within 30 days. In the second period, there were 17.0 donations/1000 people and a rate of 2.1 people/10,000 donations (OR:14.0 CI95 %:12.2-16.0). For the last period, there were 18.2 donations/1000 people and a rate of 0.9 individuals/10,000 donations (OR:31.3 CI95 %:26.6-36.9, p < 0.001). CONCLUSION: DDR reduced by 31 times the acceptance of blood donors who made more than one whole blood donation in the same month. It was necessary to provide periodic feedback and promote web service implementation to reduce this risky behavior.
Assuntos
Doação de Sangue , Doadores de Sangue , Masculino , Humanos , Feminino , Sistema de Registros , Bancos de Sangue , ColômbiaRESUMO
BACKGROUND AND PURPOSE: Hemovigilance is a set of monitoring methods that covers the blood transfusion chain, from collecting blood and blood products to monitoring the blood recipients. To this end, any error in this process can have serious and irreparable consequences for patients. The present study aimed to investigate the quality of hemovigilance process in Iran, using the first two steps of Six Sigma model. METHODS: This was a quantitative cross-sectional study that was conducted over 6 months (from August 20, 2021, to February 20, 2022) at Afzalipour Hospital in Iran, using the first two steps of Six Sigma model. The study population comprised of all inpatients who needed blood or blood product transfusion in various departments of Afzalipour Hospital, among whom 477 patients were selected via stratified sampling in three shifts (morning, evening, and night). The datasheet was used to record errors in the three shifts. This research was conducted, using the DMAIC cycle's "define" and "measure" steps. RESULTS: In the define step, the hemovigilance process at Afzalipour Hospital was divided into two categories of normal process and emergency process. Each of these processes consists of several sub-processes, including "phlebotomy," "requesting blood and blood products from the department," "preparation of application by the blood bank," " sending a request from the blood bank to the blood transfusion center," "transfusing blood and blood products," and "returning the blood and blood products to the blood bank and waste disposal." In the measure step, the quality of hemovigilance process was evaluated based on sub-processes and labels at morning, evening and night shifts. The sub-process of sending a request from the blood bank to the blood transfusion center had the highest error rate with a sigma level of 1.5. Also, the evening and night shifts had a sigma level of 1.875, and the clinical and registration labels had a sigma level of 1.875. The overall sigma level of hemovigilance process was calculated to be 2. CONCLUSION: The results of this study showed that the quality of hemovigilance process at Afzalipour Hospital was poor. By employing the first two steps of Six Sigma method, we identified the existing errors in the hemovigilance process of Afzalipour hospital in order to assist hospital managers to take the necessary measures to improve this process.
Assuntos
Segurança do Sangue , Gestão da Qualidade Total , Humanos , Estudos Transversais , Transfusão de Sangue , Bancos de SangueRESUMO
BACKGROUND: Red blood cell alloimmunisation during the pregnancy is a significant cause for neonatal mortality and morbidity. This study was planned to determine the prevalence and specificity of irregular erythrocyte antibodies in antenatal mothers and their neonatal outcome. METHODS: In this observational study, blood grouping and red cell antibody screening of mothers were performed at first visit and after 28 weeks of gestation and positive cases were identified and followed up monthly till delivery by repeating antibody titre and middle cerebral artery-peak systolic velocity. After delivery of alloimmunised mothers, cord blood haemoglobin, bilirubin and direct antiglobulin tests (DAT) were analysed and further outcome of neonate was recorded. RESULTS: Among 652 registered antenatal cases, 18 multigravida women were found to be alloimmunised, accounting to prevalence of 2.8%. Most common alloantibody identified was anti D (>70%) followed by anti-Lea, anti-C, anti-Leb, anti-E and anti-Jka. Only 47.7% Rh D negative women received anti-D prophylaxis during previous pregnancies or whenever indicated. DAT was positive in 56.2% of neonates. Among nine DAT positive neonates, two early neonatal deaths due to severe anaemia were observed following birth resuscitation. Four antenatal mothers required intrauterine transfusion in view of fetal anaemia while three neonates received double volume exchange transfusion and top up transfusions after birth. CONCLUSIONS: This study emphasises importance of red cell antibody screening for all multigravida antenatal women at registration of pregnancy and additionally at 28 weeks or later in high-risk cases irrespective of RhD status.
Assuntos
Bilirrubina , Eritrócitos , Gravidez , Recém-Nascido , Feminino , Humanos , Centros de Atenção Terciária , ÍndiaRESUMO
Human visceral leishmaniasis (HVL) is a neglected disease that occurs in 98 countries on five continents, and it is endemic in tropical and subtropical regions. In South America, the etiological agent of HVL is Leishmania infantum (syn. Leishmania chagasi), mainly transmitted through the bite of an infected sandfly female from the genus Lutzomyia. In American HVL endemic areas, the occurrence of asymptomatic infection is common, which contributes to the possibility of L. infantum transmission during a blood transfusion. To know the prevalence of L. infantum asymptomatic infection in blood donors from the microregion of Adamantina, we investigated 324 peripheral blood samples from donors through immunofluorescence (IFAT) and PCR-RFLP techniques. Seven blood samples (2.16%) tested positive for Leishmania by IFAT, and from those, six presented positive results by PCR (85.71%), which were later identified as L. infantum by RFLP. The presence of L. infantum in the peripheral blood of blood donors supported the hypothesis of transmission by blood transfusion and points to the need to include tests for visceral leishmaniasis in blood bank screening tests and pre-storage measures, especially in endemic areas to prevent the exponential increase of HVL by blood transfusion.
Assuntos
Leishmania infantum , Leishmaniose Visceral , Psychodidae , Animais , Humanos , Feminino , Leishmania infantum/genética , Leishmaniose Visceral/diagnóstico , Leishmaniose Visceral/epidemiologia , Doadores de Sangue , Infecções Assintomáticas , Reação em Cadeia da PolimeraseRESUMO
Complexities of D within the Rh blood group system have long been recognized, initially using basic serologic testing and, more recently, using advanced and sensitive typing reagents. Discrepancies may arise when an individual carries a D antigen showing altered D antigen expression. These D variants are clinically important, since they may lead to production of anti-D in the carrier and induce alloimmunization in D- recipients, making their correct identification imperative. For clinical purposes, D variants can be classified into three groups: weak D, partial D, and DEL. The problem surrounding proper characterization of D variants exists because routine serologic tests are sometimes inadequate to detect D variants or resolve discrepant or ambiguous D typing results. Today, molecular analysis has revealed more than 300 RH alleles and is a better method for investigating D variants. Global distribution of variants differs, as observed in European, African, and East Asian populations. Discovery of the novel RHD*01W.150 (weak D type 150) with a nucleotide change of c.327_487-4164dup is proof. This variant, the result of an insertion of a duplicated exon 3 between exons 2 and 4 in the same orientation, was detected in more than 50 percent of Indian D variant samples in a 2018 study. The outcome of studies worldwide has led to the recommendation to manage D variant individuals as D+ or D- according to RHD genotype. The policies and workup with respect to D variant testing in donors, recipients, and prenatal women differ among blood banks, depending on type of variants predominantly encountered. Thus, a general genotyping protocol cannot be followed globally, and an Indian-specific RHD genotyping assay (multiplex polymerase chain reaction) designed to detect D variants frequently found in the Indian population was developed to save time and resources. This assay is also helpful for detecting several partial and null alleles. Identification of D variants by serology and characterization by molecular testing need to go hand-in-hand for better and safer transfusion practices.
Assuntos
Transfusão de Sangue , Sistema do Grupo Sanguíneo Rh-Hr , Gravidez , Humanos , Feminino , Sistema do Grupo Sanguíneo Rh-Hr/genética , Genótipo , Bancos de Sangue , Éxons , Alelos , Doadores de SangueRESUMO
BACKGROUND: Unanticipated transfusion requirements during liver transplantation can delay lifesaving intraoperative resuscitation and strain blood bank resources. Risk-stratified preoperative blood preparation can mitigate these deleterious outcomes. STUDY DESIGN AND METHODS: A two-tiered blood preparation protocol for liver transplantation was retrospectively evaluated. Eleven binary variables served as criteria for high-risk (HR) allocation. Primary outcomes included red blood cell (RBC), plasma (FFP), and platelet (Plt) utilization. Secondary outcomes included product under- and overpreparation. Contingency tables for transfusion requirements above the population means were generated using 15 clinical variables. Modified protocols were developed and retrospectively optimized using the study population. RESULTS: Of 225 recipients, 102 received HR preoperative orders, which correlated to higher intraoperative transfusion requirements. However, univariate analysis identified only two statistical risk factors per product: Hgb ≤7.8 g/dl (p < .001) and MELD ≥38 (p = .035) for RBCs, Hgb ≤7.8 g/dl (p = .002) and acute alcoholic hepatitis (p = 0.015) for FFP, and Hgb ≤7.8 g/dl (p = .001) and normothermic liver preservation (p = .037) for Plts. Based on these findings, we developed modified protocols for individual products, which were evaluated retrospectively for their effectiveness at reducing under-preparatory events while limiting product overpreparation. Cohort statistics were used to define the preparation strategy for each protocol. Retrospective comparative analysis demonstrated the superiority of the modified protocols by improving the under-preparation rate from 24% to <10% for each product, which required a 1.56-fold and 1.44-fold increase in RBC and FFP overpreparation, respectively. Importantly, there was no difference in Plt overpreparation. DISCUSSION: We report translatable data-driven blood bank preparation protocols for liver transplantation.
Assuntos
Transplante de Fígado , Transfusão de Sangue , Transfusão de Eritrócitos/métodos , Humanos , Transplante de Fígado/métodos , Plasma , Estudos RetrospectivosRESUMO
BACKGROUND: Civilian and military guidelines recommend early balanced transfusion to patients with life-threatening bleeding to improve survival. To provide the best care to patients with hemorrhagic shock in regions with reduced access to evacuation, blood preparedness must be ensured also on a municipal health care level. The primary aim of the Norwegian Blood Preparedness project is to enable rural hospitals, prehospital ambulance services, and municipal health care services to start early balanced blood transfusions for patients with life-threatening bleeding regardless of etiology. STUDY DESIGN AND METHODS: The project is designed based on three principles: (1) Early balanced transfusion should be provided for patients with life-threatening bleeding, (2) Management of an emergency requires a planned and rehearsed day-to-day system for blood preparedness, and (3) A decentralized system is needed to ensure local self-sufficiency in an emergency. We developed a system for education and training in blood-based resuscitation with a focus on the municipal health care service. RESULTS: In this publication, we describe the implementation of emergency whole blood collections from a preplanned civilian walking blood bank in the municipal health care service. This includes donor selection, whole blood collection, emergency transfusion and quality assessment of practice. CONCLUSION: We conclude that implementation of a Whole Blood based emergency transfusion program is feasible on all health care levels and that a preplanned civilian walking blood bank should be considered in locations were prolonged transport-times may reduce access to blood transfusion for patients with life threatening bleeding.
Assuntos
Bancos de Sangue , Serviços Médicos de Emergência , Ambulâncias , Atenção à Saúde , Hemorragia/etiologia , Hemorragia/terapia , Hospitais Rurais , Humanos , NoruegaRESUMO
BACKGROUND: The United States Armed Services Blood Program (ASBP) faced complex blood supply challenges during two decades of military operations in the U.S. Central Command (CENTCOM) and through an adaptive, responsive, and agile system, gained valuable insights on blood product usage in combat casualty care. STUDY DESIGN AND METHODS: A retrospective review of blood product introduction and utilization trends was compiled from ASBP data collected during CENTCOM operations from 2014 through 2021. RESULTS: During the study period, several blood products were introduced to the CENTCOM area of operations including Low Titer O Whole Blood (LTOWB), Cold-Stored Platelets (CSP), Liquid Plasma (LP), and French Freeze Dried Plasma (FDP) manufactured from U.S. sourced donor plasma, all while expanding Walking Blood Bank capabilities. There was a gradual substitution of component therapy for whole blood; blood utilization peaked in 2017. Transfusion of Fresh Whole Blood (FWB) from Walking Blood Banks decreased as fully pre-tested LTOWB was supplied by the ASBP. LTOWB was initially supplied in citrate-phosphate-dextrose (CPD) anticoagulant (21-day shelf life) but was largely replaced with LTOWB in citrate-phosphate-dextrose-adenine (CPDA-1) anticoagulant (35-day shelf life) by 2019. Implementation of prehospital transfusion and expansion of surgical and resuscitation teams led to an increase in the number of sites receiving blood. DISCUSSION: ASBP introduced new products to its inventory in order to meet changing blood product demands driven by changes in the Joint Trauma System Clinical Practice Guidelines and operational demands. These products were adopted into clinical practice with a resultant evolution in transfusion strategies.
Assuntos
Ressuscitação , Ferimentos e Lesões , Anticoagulantes , Citratos , Glucose , Humanos , Fosfatos , Estados Unidos , Ferimentos e Lesões/terapiaRESUMO
BACKGROUND: The Blood Donation Service West serves North Rhine-Westphalia (NRW), Rhineland-Palatinate (RP), and Saarland, an area of 56,500 km2. In addition to routine red blood cell concentrates, plasma, and platelets, special products are provided. Since 2014, this has included autologous serum eye drops (ASED) for topical use in patients suffering from different illnesses accompanied by dry eye disease. METHODS: A volume of 250-525 mL of patient blood was collected into an anticoagulant-free blood bag. Laboratory testing included Hepatitis B/C-, HIV 1/2-, and Lues-serology. Coagulation and centrifugation were followed by leukoreduction. Single-use vials were obtained by filling mini-bag systems using a sterile tube welder. Storage at ≤-20 °C enabled a shelf-life of up to 6 months and 30 days at 4 °C after thawing for shipment. RESULTS: Contracts were closed with 15 ophthalmology clinics and medical practices in NRW and RP to supply patients with ASED. The patient pool increased from 19 in 2014 to 46 in 2020, with an average age of 43-55 years. Overall, blood collections almost tripled from 31 to 100 per year, increasing the stock of deliverable single-use vials from 3328 to 13,358. Delivery in a liquid state allowed engagement of 44 pharmacies located in the patient neighborhoods for continuous supply. CONCLUSION: Manufacturing in a closed bag system allowed integration into blood bank operations. However, cost-coverage by health insurance remained a case-by-case decision. Allogeneic application as 'just-another-blood-product' could be an aspiration. Yet, conclusive data from large clinical trials are needed for licensed provision in Germany.