Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proteomics ; 24(16): e2300607, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38783781

RESUMO

In this study, we sought to compare protein concentrations obtained from a high-throughput proteomics platform (Olink) on samples collected using capillary blood self-collection (with the Tasso+ device) versus standard venipuncture (control). Blood collection was performed on 20 volunteers, including one sample obtained via venipuncture and two via capillary blood using the Tasso+ device. Tasso+ samples were stored at 2°C-8°C for 24-hs (Tasso-24) or 48-h (Tasso-48) prior to processing to simulate shipping times from a study participant's home. Proteomics were analyzed using Olink (384 Inflammatory Panel). Tasso+ blood collection was successful in 37/40 attempts. Of 230 proteins included in our analysis, Pearson correlations (r) and mean coefficient of variation (CV) between Tasso-24 or Tasso-48 versus venipuncture were variable. In the Tasso-24 analysis, 34 proteins (14.8%) had both a correlation r > 0.5 and CV < 0.20. In the Tasso-48 analysis, 68 proteins (29.6%) had a correlation r > 0.5 and CV < 0.20. Combining the Tasso-24 and Tasso-48 analyses, 26 (11.3%) proteins met these thresholds. We concluded that protein concentrations from Tasso+ samples processed 24-48 h after collection demonstrated wide technical variability and variable correlation with a venipuncture gold-standard. Use of home capillary blood self-collection for large-scale proteomics should be limited to select proteins with good agreement with venipuncture.


Assuntos
Coleta de Amostras Sanguíneas , Proteômica , Humanos , Proteômica/métodos , Coleta de Amostras Sanguíneas/métodos , Masculino , Adulto , Feminino , Flebotomia/métodos , Proteínas Sanguíneas/análise , Ensaios de Triagem em Larga Escala/métodos , Pessoa de Meia-Idade
2.
Clin Chem Lab Med ; 61(11): 2002-2009, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37270688

RESUMO

OBJECTIVES: Contamination of blood samples from patients receiving intravenous fluids is a common error with potential risk to the patient. Algorithms based on the presence of aberrant results have been described but have the limitation that not all infusion fluids have the same composition. Our objective is to develop an algorithm based on the detection of the dilution observed on the analytes not usually included in infusion fluids. METHODS: A group of 89 cases was selected from samples flagged as contaminated. Contamination was confirmed by reviewing the clinical history and comparing the results with previous and subsequent samples. A control group with similar characteristics was selected. Eleven common biochemical parameters not usually included in infusion fluids and with low intraindividual variability were selected. The dilution in relation to the immediate previous results was calculated for each analyte and a global indicator, defined as the percentage of analytes with significant dilution, was calculated. ROC curves were used to define the cut-off points. RESULTS: A cut-off point of 20 % of dilutional effect requiring also a 60 % dilutional ratio achieved a high specificity (95 % CI 91-98 %) with an adequate sensitivity (64 % CI 54-74 %). The Area Under Curve obtained was 0.867 (95 % CI 0.819-0.915). CONCLUSIONS: Our algorithm based on the global dilutional effect presents a similar sensitivity but greater specificity than the systems based on alarming results. The implementation of this algorithm in the laboratory information systems may facilitate the automated detection of contaminated samples.


Assuntos
Serviços de Laboratório Clínico , Laboratórios Clínicos , Humanos , Curva ROC , Fezes , Algoritmos
3.
Clin Chem Lab Med ; 61(1): 93-103, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36302372

RESUMO

OBJECTIVES: Clinical decision-making in emergency medicine is under constant pressure from demand and performance requirements, with blood tests being a fundamental part of this. However, the preanalytical process has received little attention. Therefore, this study aimed to investigate the quality of preanalytical phase processes in European emergency departments (EDs) from the perspectives of the three main providers: clinicians, nurses, and laboratory specialists. METHODS: This online survey, distributed among European EDs and laboratories, was supported by the European Society for Emergency Nursing (EUSEN), European Society for Emergency Medicine (EuSEM), and the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM). The size of the centres, the European region, the responder's profession and the country's economic condition were used as co-variables. RESULTS: We included 376 responses from all ED-related professions from 306 European centres. In 66.9% of all ED visits, at least one blood test was performed. Tests were requested mostly by nurses (44.6%) using electronic Order/Entry systems (65.4%). Only a minority (19%) reported not using laboratory quality indicators (QIs). Most responders defined the TAT starting point "when the laboratory receives the sample" (66.1%), defining the goal to be "less than 60 min" (69.9%), but only 42.4% of the centres estimated achieving this goal. CONCLUSIONS: Our survey illustrates the current situation on preanalytical blood sample processing in European EDs from the clinical and laboratory perspectives. The results emphasise the importance of the IT infrastructure and QI usage in this process and highlight some differences between European regions.


Assuntos
Química Clínica , Fase Pré-Analítica , Humanos , Laboratórios , Inquéritos e Questionários , Serviço Hospitalar de Emergência
4.
Artigo em Inglês | MEDLINE | ID: mdl-37997299

RESUMO

AIMS: The aim of this study is to measure staff compliance with the local umbilical cord lactate (UCL) sampling guideline and investigate the quality of paired UCG samples at a tertiary maternity unit. METHODS: We performed a retrospective consecutive sampling of 100 babies delivered via emergency caesarean section and 50 babies with each of all other guideline-based indications for UCL sampling born on and before 31 December 2021. Data were extracted from physical and electronic records. Compliance with guideline-based indications for UCL at birth was measured. The proportion of valid UCG samples was calculated. Samples were considered invalid under the following cases: (i) inadvertently collecting from the same vessel, (ii) switching arterial and venous samples, (iii) collecting from only one vessel or (iv) committing errors during sample collection and handling. RESULTS: Of the samples collected at birth from 321 babies, 280 (87%) had UCL. Small for gestational age and concerns about fetal well-being in labour were indications associated with poorer compliance, 66% and 78%, respectively. About 99 (44%) babies of 226 babies with UCG performed had valid UCG samples. The most common reasons for invalid samples were collection and handling errors (22%) and inadvertent collection from the same vessel (15%). CONCLUSIONS: Generally, compliance with the guidelines is good. However, invalid UCG samples were more frequent than expected.

5.
Medicina (Kaunas) ; 59(11)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-38003952

RESUMO

Platelet-rich fibrin (PRF) is a second-generation platelet concentrate whose use in clinical practice has been widely disseminated. This has led to the development of several commercial protocols, creating great confusion as to the terminology and implications of each of them. This integrative review aims to identify the critical factors of each of the phases of the solid-based PRF matrix protocol and their possible influence on their macro- and microscopic characteristics. An electronic search of the MEDLINE database (via PubMed), Web of Science, Scopus, LILACS, and OpenGrey was carried out. The search was temporarily restricted from 2001 to 2022. After searching, 43 studies were included that met the established criteria. There were numerous factors to consider in the PRF protocol, such as the material of the blood collection tubes, the duration of phlebotomy, the parameters related to blood centrifugation, the time from centrifugation to dehydration of the fibrin clots and their dehydration into membranes, as well as the time to clinical use. These factors influenced the macro- and microscopic characteristics of the PRF and its physical properties, so knowledge of these factors allows for the production of optimised PRF by combining the protocols and materials.


Assuntos
Fibrina Rica em Plaquetas , Cirurgia Bucal , Humanos , Desidratação , Leucócitos , Plaquetas
6.
Aust Crit Care ; 36(6): 1129-1137, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36635184

RESUMO

OBJECTIVES: The objective of this study was to critically appraise and synthesise evidence for blood conservation strategies in intensive care. Blood sampling is a critical aspect of intensive care to guide clinical decision-making. Repeated blood sampling can result in blood waste and contamination, leading to iatrogenic anaemia and systemic infection. REVIEW METHOD USED: Cochrane systematic review methods were used including meta-analysis, and independent reviewers. DATA SOURCES: A systematic search was conducted in Medline, CINAHL, PUBMED and EMBASE databases. The search was limited to randomised controlled trials (RCTs) and cluster RCTs, published in English between 2000 and 2021. REVIEW METHODS: Paired authors independently assessed database search results and identified eligible studies. Trials comparing any blood conservation practice or product in intensive care were included. Primary outcomes were blood sample volumes and haemoglobin change. Secondary outcomes included proportion of patients receiving transfusions and infection outcomes. Quality appraisal employed the Cochrane Risk of Bias tool. Meta-analysis using random effects approach and narrative synthesis summarised findings. RESULTS: Eight studies (n = 1027 patients), all RCTs were eligible. Six studies included adults, one studied paediatrics and one studied preterm infants. Seven studies evaluated a closed loop blood sampling system, and one studied a conservative phlebotomy protocol. Studies were of low to moderate quality. Meta-analysis was not possible for interventions targeting blood sample volumes or haemoglobin. Decreased blood sample volumes reported in four studies were attributable to a closed loop system or conservative phlebotomy. No study reported a significant change in haemoglobin. Meta-analysis demonstrated that use of a closed system (compared to open system) reduced the proportion of patients receiving transfusion [Risk Ratio (RR) 0.65, 95% CI 0.46-0.92; 287 patients] and reduced intraluminal fluid colonisation [RR 0.25, 95% CI 0.07-0.58; 500 patients]. CONCLUSIONS: Limited evidence demonstrates closed loop blood sampling systems reduced transfusion use and fluid colonisation. Simultaneous effectiveness-implementation evaluation of these systems and blood conservation strategies is urgently required. PROSPERO PROTOCOL REGISTRATION REFERENCE: CRD42019137227.


Assuntos
Cuidados Críticos , Recém-Nascido Prematuro , Recém-Nascido , Adulto , Humanos , Criança , Hemoglobinas
7.
Pol J Radiol ; 87: e592-e596, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36532249

RESUMO

Purpose: Unenhanced magnetic resonance imaging (MRI) is known to be useful in characterizing adrenal adenomas through the implementation of in-phase (IPI) and opposed-phase imaging (OPI) based on chemical shift artifacts. However, whether unenhanced MRI can contribute to the identification of right adrenal vein (RAV) remains unclear. The aim of this study was to evaluate the feasibility of unenhanced MRI for the identification of RAV. Material and methods: This retrospective study reviewed 30 patients (16 men; median age 60 years; range 34-76 years) who underwent MRI and subsequent adrenal venous sampling (AVS). Chemical shift MRI was acquired using echo times of 2.3 ms (OPI) and 4.6 ms (IPI) with a slice thickness of 3 mm and a gap of 1 mm. T2-weighted imaging (T2WI) was also performed. Identification of RAVs was performed by 2 independent radiologists. Inter-observer agreement on a 3-point rating scale was evaluated using κ statistics. The identification rate of RAVs was compared between OPI, IPI, and T2WI using McNemar's test. Results: Good inter-observer agreement was found for the OPI (κ = 0.744), whereas fair agreement was obtained for both other sequences (IPI: κ = 0.375; T2WI: 0.348). For both raters, the identification rate of RAVs was higher with OPI (36/60; 60.0%) than with other sequences (IPI: 16/60, 26.7%; T2WI: 9/60, 15.0%; p < 0.05, each). Conclusions: OPI may play a screening role in the identification of RAVs preceding AVS, which could reduce the required radiation exposure and doses of contrast agent.

8.
Crit Rev Clin Lab Sci ; 58(3): 207-224, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33929278

RESUMO

In the clinical laboratory, knowledge of and the correct use of clot activators and anticoagulant additives are critical to preserve and maintain samples in optimal conditions prior to analysis. In 2017, the Latin America Confederation of Clinical Biochemistry (COLABIOCLI) commissioned the Latin American Working Group for Preanalytical Phase (WG-PRE-LATAM) to study preanalytical variability and establish guidelines for preanalytical procedures to be applied by clinical laboratories and health care professionals. The aim of this critical review, on behalf of COLABIOCLI WG-PRE-LATAM, is to provide information to understand the mechanisms of the interactions and reactions that occur between blood and clot activators and anticoagulant additives inside evacuated tubes used for laboratory testing. Clot activators - glass, silica, kaolin, bentonite, and diatomaceous earth - work by surface dependent mechanism whereas extrinsic biomolecules - thrombin, snake venoms, ellagic acid, and thromboplastin - start in vitro coagulation when added to blood. Few manufacturers of evacuated tubes state the type and concentration of clot activators used in their products. With respect to anticoagulant additives, sodium citrate and oxalate complex free calcium and ethylenediaminetetraacetic acid chelates calcium. Heparin potentiates antithrombin and hirudin binds to active thrombin, inactivating the thrombin irreversibly. Blood collection tubes have improved continually over the years, from the glass tubes containing clot activators or anticoagulant additives that were prepared by laboratory personnel to the current standardized evacuated systems that permit more precise blood/additive ratios. Each clot activator and anticoagulant additive demonstrates specific functionality, and both manufacturers of tubes and laboratory professional strive to provide suitable interference-free sample matrices for laboratory testing. Both manufacturers of in vitro diagnostic devices and laboratory professionals need to understand all aspects of venous blood sampling so that they do not underestimate the impact of tube additives on laboratory testing.


Assuntos
Anticoagulantes , Coleta de Amostras Sanguíneas , Anticoagulantes/farmacologia , Coagulação Sanguínea , Humanos , Flebotomia
9.
Scand J Clin Lab Invest ; 81(6): 508-510, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34182857

RESUMO

The increasing use of Point Of Care Testing (POCT) in the prehospital setting demands a high and consistent quality of blood samples. We have investigated the degree of haemolysis in 779 prehospital blood samples and found a significant increase in haemolysis compared to intrahospital samples. The degree of haemolysis was within acceptable limits for current analyses. However, haemolysis should be taken into account when implementing future analyses in the prehospital field.


Assuntos
Coleta de Amostras Sanguíneas , Hemólise/fisiologia , Hospitais , Idoso , Humanos
10.
Scand J Clin Lab Invest ; 81(6): 461-468, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34278897

RESUMO

In this study, we evaluated the in vitro stability of direct oral anticoagulants (DOACs) in blood samples of 57 patients under different storage conditions using functional coagulation assays. We determined the analyte concentrations (1) immediately after blood collection (baseline); (2) after storage of citrated whole blood (agitated) at room temperature and citrated plasma at room temperature and at 4 °C for 4, 8, and 24 h, respectively; and (3) after storage of citrated plasma at -20 °C for 30, 60, and 90 days. According to the concept of acceptable change limits (ACL), analytes were considered stable if the mean relative analyte recovery at a given time was >78%. The mean baseline values (range) of dabigatran, rivaroxaban, apixaban, and edoxaban were 115 ng/mL (62-217), 129 ng/mL (31-215), 156 ng/mL (49-362), and 101 ng/mL (33-283), respectively. After applying the analyte stability limit, all four DOACs were stable for 24 h at room temperature and at 4 °C. The mean recovery after 24 h was 102-111% for dabigatran, 88-97% for rivaroxaban, 95-98% for apixaban, and 90-96% for edoxaban. When plasma samples were stored at -20 °C, the mean percentage deviation after 90 days for all four DOACs was ≤10%, even after three freeze-thaw cycles. Thus, for the correct determination of DOAC plasma concentrations, blood samples do not have to be analyzed immediately and can be stored at room temperature for up to 24 h before analysis. In clinical practice, blood sample transport and storage for DOAC measurements appear to be unproblematic.


Assuntos
Anticoagulantes/administração & dosagem , Anticoagulantes/sangue , Coleta de Amostras Sanguíneas , Preservação Biológica , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Dabigatrana/sangue , Humanos , Pessoa de Meia-Idade , Pirazóis/sangue , Piridinas/sangue , Piridonas/sangue , Rivaroxabana/sangue , Tiazóis/sangue
11.
Transfus Apher Sci ; 59(4): 102812, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32439491

RESUMO

BACKGROUND AND OBJECTIVE: There are several steps in transfusion chain where accurate documentation is critical. This study was conducted to evaluate the frequency of documentation errors during transfusion process and to evaluate the effectiveness of interventions in error-management. METHODS /MATERIAL: This study was conducted at Aga Khan University, Pakistan during 2016-2018. Transcription and bedside documentation errors were identified from in-house computerized system and from medical charts. Raw WBIT rate was calculated for repeat blood samples and adjusted for frequencies of ABO-groups in our population accounting for silent WBIT. Rate of ABO-mismatched red cell transfusions was calculated for the annual totals of red cell transfusions. Chi-square was used for observing relationship among errors of various data sets. RESULTS: A total of 43 WBIT was identified during 54,219 repeat blood samples where blood group was already defined in blood bank information system. Annual unadjusted and cryptic WBIT rate was consistent at 0.8 and 0.6 per 1000 samples respectively during 2016-2018 (p 0.859). There were 1161 transcription errors (1.1 %) in blood group documentation in 105,064 blood samples received for arranging blood products. ABO-mismatched transfusion rate was 0.9 for 10,000 RBC transfusions in pre- and decreased to 0.4 in post-typing era. Overall, the compliance for completing checklist, correct ABO technique and appropriate ABO-interpretation was 88 %, 40 % and 24 % in the reviewed medical charts. CONCLUSIONS: Sample labeling errors were not improved through training or counseling. Bedside ABO-typing and checklist prior to blood transfusion can control the ABO-mismatched transfusion if done timely and correctly.


Assuntos
Transfusão de Sangue/métodos , Documentação/normas , Erros Médicos/estatística & dados numéricos , Adulto , Idoso , Feminino , Humanos , Masculino
12.
J Clin Monit Comput ; 33(4): 549-556, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29992507

RESUMO

Injection ports used to administer medications and draw blood samples have inherent dead-volume. This volume can potentially lead to inadvertent drug administration, contribute to erroneous laboratory values by dilution of blood samples, and increase the risk of vascular air embolism. We sought to characterize provider practice in management of intravenous (IV) and arterial lines and measure dead-volumes of various injection ports. A survey was circulated to anesthesiology physicians and nurses to determine practice habits when administering medications and drawing blood samples. Dead-volume of one and four-way injection ports was determined by injecting methylene blue to simulate medication administration or blood sample aspiration and using absorption spectroscopy to measure sample concentration. Among the 65 survey respondents, most (64.52%) increase mainstream flow rate to flush medication given by a 1-way injection port. When using 4-way stopcocks, 56.45% flush through the same injection site. To obtain a sample from an arterial line, 67.74% draw back blood and collect the sample from the same 4-way stopcock; 32.26% use a different stopcock. Mean (SD) dead-volume in microliters ranged from 0.1 (0.0) to 5.6 (1.0) in 1-way injection ports and from 54.1 (2.8) to 126.5 (8.3) in 4-way injection ports. The practices of our providers when giving medications and drawing blood samples are variable. The dead-volume associated with injection ports used at our institution may be clinically significant, increasing errors in medication delivery and laboratory analysis.


Assuntos
Administração Intravenosa , Coleta de Amostras Sanguíneas/instrumentação , Cateteres de Demora , Sistemas de Liberação de Medicamentos , Embolia Aérea/prevenção & controle , Bombas de Infusão , Segurança do Paciente , Calibragem , Desenho de Equipamento , Humanos , Infusões Intravenosas , Pressão , Software , Espectrofotometria
13.
Crit Rev Clin Lab Sci ; 55(7): 480-500, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30309270

RESUMO

The constrained economic context leads laboratories to centralize their routine analyses on high-throughput platforms, to which blood collection tubes are sent from peripheral sampling sites that are sometimes distantly located. Providing biochemistry results as quickly as possible implies to consolidate the maximum number of tests on a minimum number of blood collection tubes, mainly serum tubes and/or tubes with anticoagulants. However, depending on the parameters and their pre-analytical conditions, the type of matrix - serum or plasma - may have a significant impact on results, which is often unknown or underestimated in clinical practice. Importantly, the matrix-related effects may be a limit to the consolidation of analyses on a single tube, and thus must be known by laboratory professionals. The purpose of the present critical review is to put forward the main differences between using serum and plasma samples on clinical biochemistry analyses, in order to sensitize laboratory managers to the need for standardization. To enrich the debate, we also provide an additional comparison of serum and plasma concentrations for approximately 30 biochemistry parameters. Properties, advantages, and disadvantages of serum and plasma are discussed from a pre-analytical standpoint - before, during, and after centrifugation - with an emphasis on the importance of temperature, delay, and transport conditions. Then, differences in results between these matrices are addressed for many classes of biochemistry markers, particularly proteins, enzymes, electrolytes, lipids, circulating nucleic acids, metabolomics markers, and therapeutic drugs. Finally, important key-points are proposed to help others choose the best sample matrix and guarantee quality of clinical biochemistry assays. Moreover, awareness of the implications of using serum and plasma samples on various parameters assayed in the laboratory is an important requirement to ensure reliable results and improve patient care.


Assuntos
Testes de Química Clínica , Plasma/química , Soro/química , Coleta de Amostras Sanguíneas , Testes de Química Clínica/métodos , Testes de Química Clínica/normas , Humanos , Segurança do Paciente , Reprodutibilidade dos Testes , Gestão da Qualidade Total
14.
Clin Chem Lab Med ; 56(11): 1806-1818, 2018 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-29729140

RESUMO

BACKGROUND: The stability limit of an analyte in a biological sample can be defined as the time required until a measured property acquires a bias higher than a defined specification. Many studies assessing stability and presenting recommendations of stability limits are available, but differences among them are frequent. The aim of this study was to classify and to grade a set of bibliographic studies on the stability of five common blood measurands and subsequently generate a consensus stability function. METHODS: First, a bibliographic search was made for stability studies for five analytes in blood: alanine aminotransferase (ALT), glucose, phosphorus, potassium and prostate specific antigen (PSA). The quality of every study was evaluated using an in-house grading tool. Second, the different conditions of stability were uniformly defined and the percent deviation (PD%) over time for each analyte and condition were scattered while unifying studies with similar conditions. RESULTS: From the 37 articles considered as valid, up to 130 experiments were evaluated and 629 PD% data were included (106 for ALT, 180 for glucose, 113 for phosphorus, 145 for potassium and 85 for PSA). Consensus stability equations were established for glucose, potassium, phosphorus and PSA, but not for ALT. CONCLUSIONS: Time is the main variable affecting stability in medical laboratory samples. Bibliographic studies differ in recommedations of stability limits mainly because of different specifications for maximum allowable error. Definition of a consensus stability function in specific conditions can help laboratories define stability limits using their own quality specifications.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Alanina Transaminase/sangue , Glicemia/química , Humanos , Fósforo/sangue , Potássio/sangue , Fase Pré-Analítica , Antígeno Prostático Específico/sangue , Estabilidade Proteica , Temperatura
15.
Clin Chem Lab Med ; 56(11): 1870-1877, 2018 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-29750640

RESUMO

BACKGROUND: When performed erroneously, the venous blood specimen collection (VBSC) practice steps patient identification, test request management and test tube labeling are at high risk to jeopardize patient safety. VBSC educational programs with the intention to minimize risk of harm to patients are therefore needed. In this study, we evaluate the efficiency of a large-scale online e-learning program on personnel's adherence to VBSC practices and their experience of the e-learning program. METHODS: An interprofessional team transformed an implemented traditional VBSC education program to an online e-learning program developed to stimulate reflection with focus on the high-risk practice steps. We used questionnaires to evaluate the effect of the e-learning program on personnel's self-reported adherence to VBSC practices compared to questionnaire surveys before and after introduction of the traditional education program. We used content analysis to evaluate the participants free text experience of the VBSC e-learning program. RESULTS: Adherence to the VBSC guideline high-risk practice steps generally increased following the implementation of a traditional educational program followed by an e-learning program. We however found a negative trend over years regarding participation rates and the practice to always send/sign the request form following the introduction of an electronic request system. The participants were in general content with the VBSC e-learning program. CONCLUSIONS: Properly designed e-learning programs on VBSC practices supersedes traditional educational programs in usefulness and functionality. Inclusion of questionnaires in the e-learning program is necessary for follow-up of VBSC participant's practices and educational program efficiency.


Assuntos
Instrução por Computador , Flebotomia/normas , Avaliação de Programas e Projetos de Saúde , Feminino , Fidelidade a Diretrizes , Humanos , Internet , Masculino , Guias de Prática Clínica como Assunto , Autorrelato , Inquéritos e Questionários
16.
Scand J Clin Lab Invest ; 78(7-8): 591-594, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30338721

RESUMO

The preanalytical phase contains a vast number of practices whose variation may influence the results of laboratory testing and should, therefore, be standardized. The Working Group on Preanalytical Phase of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM WG-PA) has suggested a standardization of venous blood specimen collection (VBSC) requirements for fasting samples including 12 h fasting time and water ad lib in the morning prior to specimen collection. The Nordic Scientific Preanalytical Working Group investigated the fasting definitions used in the Nordic countries. The Internet was assessed for stated fasting definitions of official organizations, larger laboratories, or laboratory groups. Fasting instructions for VBSC generally demanded patients to abstain from alcohol a day prior to, and to abstain from coffee, tea, smoking, and snuff intake in the morning of VBSC. Norway had a national fasting definition. Required fasting times varied from 8 to 14 h. The amount of water allowed in the morning of VBSC varied from ad lib to half a glass of water. The list of analytes, where fasting was required, held 9-15 analytes except for Finland with 65 analytes. Implementation of the EFLM WG-PRE standardization of VBSC requirements for fasting samples would decrease preanalytical variability and be beneficial for medical decisions and patient data comparison. We suggest the laboratories in the Nordic countries to implement the suggested fasting requirements, which are in line with those used when fasting reference intervals were established in the Nordic reference interval project.


Assuntos
Análise Química do Sangue/normas , Jejum , Guias de Prática Clínica como Assunto , Países Escandinavos e Nórdicos , Fatores de Tempo
17.
Scand J Clin Lab Invest ; 78(5): 407-410, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29786456

RESUMO

Posture changes have been known for a long time to influence the concentration of many analytes in blood especially macromolecules. It is very clear that when someone switches from supine to sitting or standing or from sitting to standing a hemoconcentration is induced. Similarly, when someone switches from standing to sitting or lying a hemodilution occurs. In the context of clinical chemistry, rules have been issued to buffer the impact of postural changes close to the blood specimen collection (e.g. 15 min of seated rest before the blood puncture). A big work has then been performed to educate the personnel concerned by blood specimen collection (medical doctors, nurses, phlebotomists, pharmacists, clinical researchers, scientists, etc.) through professional training to standardize the puncture and the collection procedures. Official procedures and guidelines have been published. Nevertheless, there is still a long way to go and too often standardization of posture before the blood collection is not properly performed. Maybe, this relative failure could be overcome by using new strategies in forwarding the message on the impact of posture changes in the outcome of blood tests and the importance of controlling this factor when blood specimens are taken. Some possible actions are presented concerning the improvement of the education of medical and paramedical personnel especially during their primary training, and also to educate the patients and the whole population in general.


Assuntos
Hematologia/normas , Laboratórios Hospitalares/normas , Profissionais de Enfermagem/educação , Flebotomia/normas , Postura/fisiologia , Adulto , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Hematologia/métodos , Humanos , Masculino , Guias de Prática Clínica como Assunto , Descanso/psicologia
18.
J Clin Lab Anal ; 32(6): e22427, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29512190

RESUMO

BACKGROUND: Selection and verification of blood collection tubes is an important preanalytical issue in clinical laboratories. Today, gel tubes are commonly used with many advantages, although they are known to cause interference in immunoassay methods. In this study, we aimed to compare SSTs of two different suppliers (Ayset clot activator & Gel and Becton Dickinson (BD) Vacutainer SST II advance) with reference tubes and evaluate the effect of storage time in terms of commonly used endocrine tests such as thyroid-stimulating hormone (TSH), free thyroxine (fT4), and free triiodothyronine (fT3). METHODS: Fifty-five volunteers were included in the study. Samples were taken into three different tubes and analyzed for serum TSH, fT4, and fT3 on Architect ci8200 Immunoassay System. Clinical decision levels were estimated using total allowable error (TEa). RESULTS: No difference was found between tubes in terms of TSH, fT3, and fT4 levels. From a statistical standpoint, TSH and fT4 levels were no longer stable during 24, 48, and 72 hours storage time periods. However, their variations were not clinically significant. CONCLUSION: Ayset clot activator & Gel tubes and BD Vacutainer SST II advance tubes have comparable results with glass tube in terms of TSH, fT3, and fT4 levels on Architect ci8200 Immunoassay Systems. From a clinical standpoint, serum TSH, fT4, and fT3 concentrations may be considered as stable when storing these tubes over 72 hours.

19.
Scand J Clin Lab Invest ; 77(3): 153-163, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28266238

RESUMO

The pre-analytical phase encompasses all the procedures before the start of laboratory testing. This phase of the testing process is responsible for the majority of the laboratory errors, since the related procedures involve many sorts of non-laboratory professionals working outside the laboratory setting, thus without direct supervision by the laboratory staff. Therefore, either correct organization or management of both personnel and procedures that regard blood specimen collection by venipuncture are of fundamental importance, since the various steps for performing blood collection represent per se sources of laboratory variability. The aim of this (non-systematic) review addressed to healthcare professionals is to highlight the importance of blood specimen management (from patient preparation to laboratory analyses), as a tool to prevent laboratory errors, with the concept that laboratory results from inappropriate blood specimens are inconsistent and do not allow proper treatment nor monitoring of the patient.


Assuntos
Coleta de Amostras Sanguíneas/normas , Erros de Diagnóstico/prevenção & controle , Flebotomia/normas , Gestão da Qualidade Total/organização & administração , Jejum , Hematologia , Humanos , Laboratórios , Posicionamento do Paciente/normas
20.
J Clin Lab Anal ; 31(5)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27897313

RESUMO

BACKGROUND: Prevention of a disturbance of the blood vessel allows phlebotomists to collect a blood specimen by venipuncture that will truly mirror the patient condition. This study was aimed to evaluate the impact of repeated fist clenching and maintenance of the fist during blood collection by venipuncture for routine hematology testing. METHODS: Blood were collected from 16 healthy volunteers with two separate sequential procedures, entailing standard venipuncture with hand opened throughout blood collection, or clenching the fist six times before venipuncture and maintaining the fist until completion of blood collection. The parameters tested included red blood cell (RBC) count, hemoglobin, hematocrit, mean corpuscular volume (MCV), RBC distribution width, white blood cell count and differential, including neutrophils, lymphocytes, monocytes, eosinophils, basophils, large unstained cells, platelet count, mean platelet volume, and reticulocytes. The results were reported as median and interquartile range. The comparison of data obtained with the two different venipuncture procedures (i.e., with or without fist clenching and closed hand) was performed with Wilcoxon-Mann-Whitney ranked-pairs test. The degree of statistical significance was set at P<.01. RESULTS AND CONCLUSION: Fist clenching and maintenance during blood collection for routine hematology testing was effective to increase the MCV by 1.2% (P<.001). All others hematological parameters were not significantly biased by fist clenching, though hematocrit, neutrophils, eosinophils, and reticulocytes displayed mindful of trends. We hence advise patients against clenching their fist before blood collection for hematology testing.


Assuntos
Mãos/fisiologia , Testes Hematológicos , Flebotomia , Adulto , Feminino , Testes Hematológicos/normas , Testes Hematológicos/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Flebotomia/métodos , Flebotomia/normas , Flebotomia/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA