RESUMO
BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.
Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , AdultoRESUMO
BACKGROUND: Early guidance recommended a bolus of intravenous heparin at the beginning of leadless pacemaker (LP) implantation procedures. However, due to concern about bleeding complications, more recent practice has tended toward omitting the bolus and only running a continuous heparin infusion through the introducer sheath. The impact of omitting the heparin bolus on procedural outcomes is not clear. METHODS: We reviewed all Medtronic Micra LP implants at our institution from 9/2014 to 9/2022. The decision to bolus with heparin was at operator discretion. RESULTS: Among 621 LP implants, 326 received an intravenous heparin bolus, 243 did not, and 52 patients were excluded because heparin bolus status could not be confirmed. There was a trend toward more frequent omission of the heparin bolus with more recent implants. Median follow-up after LP implant was 14.3 (interquartile range [IQR]: 8.4-27.9) months. There was no difference between heparin bolus and no bolus groups in the number of device deployments/recaptures (1.42 ± 0.81 vs. 1.31 ± 0.66, p = .15). Implant-related adverse events were also similar between heparin bolus and no bolus groups: access-site hematoma requiring intervention (7 vs. 5, p = .99), pseudoaneurysm (1 vs. 1, p = .99), cardiac perforation (1 vs. 1, p = .99), intraprocedural device thrombus formation (2 vs. 4, p = .41), 30-day rehospitalization (21 vs. 15, p = .98), and 30-day all-cause mortality (16 vs. 14, p = .70). There was one additional nonfatal cardiac perforation in a patient who was excluded due to unknown heparin bolus status. Regarding device electrical parameters between heparin bolus and no bolus groups, there were no significant differences at the time of implant: pacing capture threshold 0.5 ± 0.4 vs. 0.5 ± 0.3, p = .10; pacing impedance 739.9 ± 226.4 vs. 719.1 ± 215.4, p = .52; R wave sensing 11.7 ± 5.7 vs. 12.0 ± 5.4, p = .34). Long-term device performance was also similar between groups. CONCLUSION: Omission of the systemic heparin bolus at the time of LP implantation appears safe in appropriately selected patients. Heparin bolus may still be considered in long cases requiring multiple device deployments or in patients at high risk for thrombotic complications.
Assuntos
Anticoagulantes , Estimulação Cardíaca Artificial , Heparina , Marca-Passo Artificial , Humanos , Heparina/administração & dosagem , Heparina/efeitos adversos , Masculino , Idoso , Feminino , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Tempo , Fatores de Risco , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Esquema de Medicação , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Desenho de PróteseRESUMO
BACKGROUND: P2Y12 inhibitors have differing associations of bradyarrhythmias. Ticagrelor has been shown to increase adenosine plasma concentrations leading to increases in bradyarrhythmias. While clopidogrel and prasugrel have not been shown to have any association with bradyarrhythmias. OBJECTIVE: The objective of this study was to determine heart rates after ticagrelor initiation compared to clopidogrel/prasugrel in inferior ST Elevation Myocardial Infarction (STEMI) patients. METHODS: This was a retrospective, multicenter study conducted at 3 primary percutaneous coronary intervention (PCI) centers between January 1, 2017 and September 30, 2022. Adult patients were included if they were diagnosed with an inferior STEMI to the right coronary artery (RCA) and treated with PCI followed by an oral P2Y12 inhibitor. The primary outcome was heart rate at 48 hours or discharge, whichever first, after administration of ticagrelor compared to clopidogrel/prasugrel. RESULTS: This study reviewed 331 patients, 172 in the ticagrelor group and 159 in the clopidogrel/prasugrel group. There were no statistical differences between groups regarding the primary outcome, with a median heart rate of 76 beats per minute (bpm) [67-85] in the ticagrelor group versus 73 bpm [66-84] in the clopidogrel/prasugrel group (P = 0.238). No differences were observed between groups regarding any secondary outcomes. CONCLUSION AND RELEVANCE: There were similar heart rates between ticagrelor and clopidogrel/prasugrel. There were also similarities in the ability to tolerate beta-blocker therapy after initiation of a P2Y12 inhibitor. The results of this study suggest that in inferior STEMIs when using ticagrelor as the P2Y12 inhibitor, there are not increased clinical manifestations of bradycardia.
RESUMO
BACKGROUND: The Wireless Stimulation Endocardially for CRT (WiSE-CRT) system is a novel technology used to treat patients with dyssynchronous heart failure (HF) by providing leadless cardiac resynchronization therapy (CRT). Observational studies have demonstrated its safety and efficacy profile, however, the treatment cost-effectiveness has not previously been examined. METHODS: A cost-effectiveness evaluation of the WiSE-CRT System was performed using a cohort-based economic model adopting a "proportion in state" structure. In addition to the primary analysis, scenario analyses and sensitivity analyses were performed to test for uncertainty in input parameters. Outcomes were quantified in terms of quality-adjusted life year (QALY) differences. RESULTS: The primary analysis demonstrated that treatment with the WiSE-CRT system is likely to be cost-effective over a lifetime horizon at a QALY reimbursement threshold of £20 000, with a net monetary benefit (NMB) of £3781 per QALY. Cost-effectiveness declines at time horizons shorter than 10 years. Sensitivity analyses demonstrated that average system battery life had the largest impact on potential cost-effectiveness. CONCLUSION: Within the model limitations, these findings support the use of WiSE-CRT in indicated patients from an economic standpoint. However, improving battery technology should be prioritized to maximize cost-effectiveness in times when health services are under significant financial pressures.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/economia , Análise de Custo-Efetividade , Insuficiência Cardíaca/terapia , Resultado do TratamentoRESUMO
Ticagrelor is currently considered a first-line choice in dual antiplatelet therapy (DAPT) following revascularization of acute coronary syndrome (ACS). However, its use is correlated with an increased incidence of two side effects, dyspnea and bradyarrhythmias, whose molecular mechanisms have not yet been defined with certainty and, consequently, neither of the therapeutic decisions they imply. We report the case of a patient with acute myocardial infarction treated with ticagrelor and aspirin as oral antithrombotic therapy after primary percutaneous coronary intervention (PCI), manifesting in a significant bradyarrhythmic episode that required a switch of antiplatelet therapy. Starting from this case report, this article aims to gather the currently available evidence regarding the molecular mechanisms underlying these side effects and propose possible decision-making algorithms regarding their management in clinical practice.
Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Ticagrelor/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Aspirina/uso terapêutico , Infarto do Miocárdio/terapia , Resultado do TratamentoRESUMO
INTRODUCTION: Bradyarrhythmias are an established red flag for storage cardiac conditions including Anderson-Fabry disease (AFD). The prevalence of bradyarrhythmias requiring a pacemaker (PM) and their timing in AFD is unresolved. METHODS: We evaluated the prevalence and predictors of PM requirement in a large AFD cohort, investigating the occurrence of bradyarrhythmias as initial versus late manifestation. We retrospectively evaluated 82 consecutive AFD patients referred to our multidisciplinary referral center from 1994 to 2020 with a median follow-up of 6.9 years, identifying those requiring pacing. Univariable analysis was performed to identify cardiac features associated with PM implantation. RESULTS: Five of 82 (6%) AFD patients required PM implantation (5/39, i.e., 13% of those with cardiac involvement), always in the context of advanced cardiomyopathy. In none, bradyarrhythmias were the presenting feature. Indications included sick sinus syndrome in three patients, advanced atrioventricular block in two patients. QRS prolongation during follow-up strongly correlated with the onset of bradyarrhythmias. CONCLUSION: Severe bradyarrhythmias are relatively frequent in patients with AFD cardiomyopathy, but do not represent a mode of presentation, occurring late in the disease course and always in the context of advanced cardiac involvement. Monitoring QRS variations over time may help to identify patients requiring pacing.
Assuntos
Cardiomiopatias , Doença de Fabry , Marca-Passo Artificial , Bradicardia/diagnóstico , Bradicardia/epidemiologia , Bradicardia/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Cardiomiopatias/diagnóstico , Cardiomiopatias/epidemiologia , Cardiomiopatias/terapia , Doença de Fabry/complicações , Humanos , Prevalência , Estudos RetrospectivosRESUMO
Active fixation for a lead in the coronary sinus may be essential to select the optimal left ventricular pacing site, maximize the effectiveness of cardiac resynchronization therapy (CRT) and avoid dislodgement. The Medtronic Attain Stability lead allows fixation through a side helix concentric with the lead body. Although electrical performance of such a lead is well known, evidence of extractability remains poor especially in the long term. We describe the removal of an Attain Stability lead 63 months after implantation which, to the best of our knowledge, is the longest implant duration that has ever been reported, in an 81-year-old male patient. It was successfully achieved using simple traction and rotation maneuvers, demonstrating the long-term removal feasibility of such device.
Assuntos
Terapia de Ressincronização Cardíaca , Seio Coronário , Insuficiência Cardíaca , Masculino , Humanos , Idoso de 80 Anos ou mais , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Dispositivos de Terapia de Ressincronização Cardíaca , Remoção de Dispositivo , Ventrículos do Coração/cirurgia , Resultado do Tratamento , Insuficiência Cardíaca/terapiaRESUMO
AIMS: There is a paucity of epidemiological evidence on alcohol and the risk of bradyarrhythmias. We thus characterized associations of total and beverage-specific alcohol consumption with incident bradyarrhythmias using data from the UK Biobank. METHODS AND RESULTS: Alcohol consumption reported at baseline was calculated as UK standard drinks (8 g alcohol)/week. Bradyarrhythmia events were defined as sinus node dysfunction (SND), high-level atrioventricular block (AVB), and permanent pacemaker implantations. Outcomes were assessed through hospitalization and death records, and dose-response associations were characterized using Cox regression models with correction for regression dilution bias. We studied 407 948 middle-aged individuals (52.4% female). Over a median follow-up time of 11.5 years, a total of 8 344 incident bradyarrhythmia events occurred. Increasing total alcohol consumption was not associated with an increased risk of bradyarrhythmias. Beer and cider intake were associated with increased bradyarrhythmia risk up to 12 drinks/week; however, no significant associations were observed with red wine, white wine, or spirit intake. When bradyarrhythmia outcomes were analysed separately, a negative curvilinear was observed for total alcohol consumption and risk of SND, but no clear association with AVB was observed. CONCLUSION: In this predominantly White British cohort, increasing total alcohol consumption was not associated with an increased risk of bradyarrhythmias. Associations appeared to vary according to the type of alcoholic beverage and between different types of bradyarrhythmias. Further epidemiological and experimental studies are required to clarify these findings.
Assuntos
Bloqueio Atrioventricular , Bradicardia , Consumo de Bebidas Alcoólicas/efeitos adversos , Consumo de Bebidas Alcoólicas/epidemiologia , Bebidas Alcoólicas/efeitos adversos , Bloqueio Atrioventricular/epidemiologia , Bradicardia/epidemiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Síndrome do Nó SinusalRESUMO
The Accufix bipolar active fixation atrial pacing lead (Model 330-801; Telectronics) can have mechanical complications due to a fracture of its J retention wire. An 80-year-old man had the Accufix atrial pacing lead implanted 29 years prior, and surgical removal was required because a part of the lead was perforating the apex of the right ventricle. Regular follow-up examinations are recommended to eliminate the possibility of protrusion and detachment of the J retention wire, even if the clinical course after implantation is stable for a prolonged period.
Assuntos
Eletrodos Implantados , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Eletrodos Implantados/efeitos adversos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Marca-Passo Artificial/efeitos adversosRESUMO
AIMS: We determined the incidence and type of arrhythmias at 2-year follow-up in patients with new-onset persistent left bundle branch block (LBBB) following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: Multicentre prospective study including 103 consecutive patients with new-onset persistent LBBB post-TAVR (SAPIEN XT/3: 53; CoreValve/Evolut R: 50). An implantable cardiac monitor (Reveal XT, Reveal Linq) was implanted before hospital discharge and patients had continuous monitoring for up to 2 years. Arrhythmic events were adjudicated in a central core lab. 1836 new arrhythmic events (tachyarrhythmias: 1655 and bradyarrhythmias: 181) occurred at 2 years. Of these, 283 (15%) occurred beyond 1 year (tachyarrhythmias 212, bradyarrhythmias 71) in 33 (36%) patients, without differences between valve type. Most late (>1 year) arrhythmic events were asymptomatic (94%) and led to a treatment change in 17 (19%) patients. A total of 71 late bradyarrhythmias [high-degree atrioventricular block (HAVB): 3, severe bradycardia: 68] were detected in 17 (21%) patients. At 2 years, 18 (17%) patients had received a permanent pacemaker (PPM) or implantable cardiac-defibrillator. PPM implantation due to HAVB predominated in the early phase post-TAVR, with only 1 HAVB event requiring PPM implantation after 1 year. CONCLUSION: Patients with new-onset LBBB post-TAVR exhibited a very high burden of arrhythmic events within the 2 years post-procedure. While new tachyarrhythmic events were homogeneously distributed over time, the vast majority of new HAVB episodes leading to PPM implantation occurred early after the procedure. These results should help to guide the management of this challenging group of patients. (clinicaltrials.gov: NCT02153307).
Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Humanos , Estudos Prospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
Cardiac amyloidosis (CA) is an increasingly recognized cause of heart failure, characterized by extracellular deposition of insoluble protein fibrils leading to progressive myocardial dysfunction. The most common types of cardiac amyloidosis are immunoglobin light-chain (AL) and transthyretin (ATTR). Conduction abnormalities are commonly encountered among patients with cardiac amyloidosis and are an important cause of morbidity and mortality. Abnormalities range from infra-Hisian intraventricular conduction delay and bundle branch block to complete atrioventricular block. Pacemaker placement in CA patients follows established guidelines, similar to those for patients without CA, with generally good efficacy. The role and appropriate timing of pacemakers for primary prevention of brady-arrhythmias in CA remains uncertain. While biventricular (BiV) pacing has been shown to improve clinical outcomes in patients with systolic heart failure without CA, there are few data examining the utility of BiV pacing in patients with CA. With the advent of effective treatments for AL and ATTR, appropriate application of pacing is important to support patients with CA and conduction disease through therapeutic trials. This systematic review summarizes the current literature examining the utility of pacing in CA.
Assuntos
Amiloidose/fisiopatologia , Amiloidose/terapia , Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Sistema de Condução Cardíaco/fisiopatologia , HumanosRESUMO
In patients with preserved ejection fraction or right bundle branch block (RBBB) pattern requiring a high percentage of ventricular pacing, His-bundle pacing (HBP) might be an alternative to biventricular pacing, although the high threshold occasionally occurs. We provided a case of the intrinsic RBBB correction by capturing intra-Hisian left bundle branch (LBB) or distal His-bundle with different output settings. LBB pacing had the advantage of a much lower threshold while remained most synchrony as HBP. LBB pacing might be a promisingly safe and effective procedure for patients with high-grade atrioventricular (AV) block and RBBB pattern.
Assuntos
Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Idoso , Humanos , MasculinoRESUMO
AIMS: Physical activity reduces cardiovascular disease burden and mortality, although its relationship with cardiac arrhythmias is less certain. The aim of this study was to assess the association between self-reported physical activity and atrial fibrillation (AF), ventricular arrhythmias and bradyarrhythmias, across the UK Biobank cohort. METHODS AND RESULTS: We included 402 406 individuals (52.5% female), aged 40-69 years, with over 2.8 million person-years of follow-up who underwent self-reported physical activity assessment computed in metabolic equivalent-minutes per week (MET-min/wk) at baseline, detailed physical assessment and medical history evaluation. Arrhythmia episodes were diagnosed through hospital admissions and death reports. Incident AF risk was lower amongst physically active participants, with a more pronounced reduction amongst female participants [hazard ratio (HR) for 1500 vs. 0 MET-min/wk: 0.85, 95% confidence interval (CI) 0.74-0.98] than males (HR for 1500 vs. 0 MET-min/wk: 0.90, 95% CI 0.82-1.0). Similarly, we observed a significantly lower risk of ventricular arrhythmias amongst physically active participants (HR for 1500 MET-min/wk 0.78, 95% CI 0.64-0.96) that remained relatively stable over a broad range of physical activity levels between 0 and 2500 MET-min/wk. A lower AF risk amongst female participants who engaged in moderate levels of vigorous physical activity was observed (up to 2500 MET-min/wk). Vigorous physical activity was also associated with reduced ventricular arrhythmia risk. Total or vigorous physical activity was not associated with bradyarrhythmias. CONCLUSION: The risk of AF and ventricular arrhythmias is lower amongst physically active individuals. These findings provide observational support that physical activity is associated with reduced risk of atrial and ventricular arrhythmias.
Assuntos
Fibrilação Atrial , Bancos de Espécimes Biológicos , Adulto , Idoso , Fibrilação Atrial/epidemiologia , Estudos de Coortes , Exercício Físico , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Reino Unido/epidemiologiaRESUMO
INTRODUCTION: Cardiac autonomic system modulation by endocardial ablation targeting atrial ganglionated plexi (GP) is an alternative strategy in selected patients with severe functional bradyarrhythmias, although no consensus exists on the best ablation strategy. The aim of this study was to evaluate if a simplified approach by a purely anatomical guided ablation of just the atrial right GP is enough for the treatment of these patients. METHODS: We prospectively enrolled patients with significant functional bradyarrhythmias and performed endocardial ablation purely guided by 3D electroanatomic mapping directed at the atrial right GP and accessed parameters of parasympathetic modulation and recurrence of bradyarrhythmias. RESULTS: Thirteen patients enrolled (76.9% male, median age 51, 42-63 years). After ablation, a median RR interval shortening of 28.3 (25.6-40.3)% occurred (1111, 937.5-1395.4 ms to 722.9, 652.2-882.4 ms, p = 0.0002). The AH interval also shortened (19, 10.5-35.7%) significantly after the procedure (115, 105-122 ms to 85, 71-105 ms, p = 0.0023) as well as Wenckebach cycle length (11.1, 5.9-17.8% shortening) from 450, 440-510 ms to 430, 400-460 ms, p = 0.0127. On 24-h Holter monitoring there was significant increase in heart rates (HR) of patients after ablation (minimal HR increased from 34 (26-43)bpm to 49 (43-56)bpm, p = 0,0102 and mean HR from 65 (47-72)bpm to 78 (67-87)bpm, p = 0.0004). No patients had recurrence of symptoms or significant bradyarrhythmias during a median follow-up of 8.4 months. CONCLUSIONS: A purely anatomic guided procedure directed only at the atrial right ganglionated plexi seems to be enough as a therapeutic approach for cardioneuroablation in selected patients with significant functional bradyarrhythmias.
RESUMO
RATIONALE & OBJECTIVE: Patients with kidney failure treated with maintenance dialysis experience a high rate of mortality, in part due to sudden cardiac death caused by arrhythmias. The prevalence of arrhythmias, including the subset that are clinically significant, is not well known. This study sought to estimate the prevalence of arrhythmias, characterize the pattern of arrhythmic events in relation to dialysis treatments, and identify associated clinical characteristics. STUDY DESIGN: Cross-sectional study. SETTING & PARTICIPANTS: 152 patients with kidney failure treated with maintenance dialysis in Denmark. EXPOSURES: Dialysis treatment; clinical characteristics; cardiac output and preload defined using echocardiography. OUTCOMES: Prevalence and pattern of arrhythmias on 48-hour Holter monitoring; odds ratios for arrhythmias. ANALYTICAL APPROACH: Descriptive analysis of the prevalence of arrhythmias. Pattern of arrhythmias described using a repeated-measures negative binomial regression model. Associations between clinical characteristics and echocardiographic findings with arrhythmias were assessed using logistic regression. RESULTS: Among the 152 patients studied, 83.6% were treated with in-center dialysis; 10.5%, with home hemodialysis; and 5.9%, with peritoneal dialysis. Premature atrial and ventricular complexes were seen in nearly all patients and 41% had paroxysmal supraventricular tachycardia. Clinically significant arrhythmias included persistent atrial fibrillation observed among 8.6% of patients, paroxysmal atrial fibrillation among 3.9%, nonsustained ventricular tachycardia among 19.7%, bradycardia among 4.6%, advanced second-degree atrioventricular block among 1.3%, and third-degree atrioventricular block among 2.6%. Premature ventricular complexes were more common on dialysis days, while tachyarrhythmias were more often observed during dialysis and in the immediate postdialytic period. Older age (OR per 10 years older, 1.53; 95% CI, 1.15-2.03; P=0.003), elevated preload (OR, 4.02; 95% CI, 1.05-15.35; P=0.04), and lower cardiac output (OR per 1L/min greater, 0.66; 95% CI, 0.44-1.00; P=0.05) were independently associated with clinically significant arrhythmias. LIMITATIONS: Arrhythmia monitoring limited to 48 hours; small sample size; heterogeneous nature of the population, risk for residual confounding. CONCLUSIONS: Arrhythmias, including clinically significant abnormal rhythms, were common. Tachyarrhythmias were more frequent during dialysis and the immediate postdialytic period. The relevance of these findings to clinical outcomes requires additional study.
Assuntos
Arritmias Cardíacas/etiologia , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Estudos Transversais , Dinamarca/epidemiologia , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Humanos , Incidência , Falência Renal Crônica/complicações , Falência Renal Crônica/mortalidade , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida/tendênciasRESUMO
A 25-year-old runner received a single-lead, VDD pacemaker after ablation of AV nodal reentrant tachycardia complicated by intermittent AV block. The rate-adaptive AV delay algorithm (RAAV), which shortens the sensed AV interval (SAV) at faster atrial rates, was programmed to provide a physiologic SAV with exercise. She developed repetitive, atypical, long-RP pacemaker-mediated tachycardia (PMT) because the RAAV shortened the antegrade SAV and retrograde conduction occurred over the slow AV nodal pathway. PMT was refractory to usual programming solutions. Using high-density electroanatomic mapping, we were able to ablate the retrograde limb of PMT without further damaging AV conduction.
Assuntos
Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Ablação por Cateter/efeitos adversos , Sistema de Condução Cardíaco/cirurgia , Marca-Passo Artificial , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Adulto , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Reoperação , Corrida , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do TratamentoRESUMO
Theleadless pacemaker (LLPM) therapy has been developed in recent years to overcome the transvenous lead and device pocket-related complications. The LLPMs now available are self-contained right ventricular pacemakers and are limited to single-chamber ventricular pacing modality. This literature review deals with the current status of LLPM technology and current areas of clinical applicability. The safety and efficacy outcomes published from randomized clinical trials and real world registries are analyzed and compared with historical conventional transvenous pacemaker data. Furthermore, new pacing modalities and future perspectives to broaden the clinical use and cover most of pacing indications are discussed. Due to the overall safe and effective profile in the short term and intermediate term, also in fragile patients, the LLPM use is constantly growing in daily clinical practice. Actually, it can be considered a landmark innovation, through which a new era of cardiac pacing has begun.
Assuntos
Arritmias Cardíacas/terapia , Marca-Passo Artificial , Estimulação Cardíaca Artificial , Desenho de Equipamento , HumanosRESUMO
BACKGROUND: In many genetic and acquired non-ischaemic cardiomyopathies (NICM) there have been frequent reports of involvement of the interventricular septum (IVS) by late gadolinium enhancement (LGE) at cardiac magnetic resonance (CMR). However, no studies have investigated the relationship between septal LGE and arrhythmias in different NICM subtypes. METHODS: This study enrolled 103 patients with septal LGE at baseline CMR and different NICM: hypertrophic (n=29) or lamin A/C gene (LMNA)-associated (n=23) cardiomyopathy, and acute (n=30) or previous (n=21) myocarditis. During follow-up, the occurrences of malignant ventricular arrhythmias (MVA) and major bradyarrhythmias (BA) were evaluated. RESULTS: At 4.9±0.7 years of follow-up, the occurrence of MVA and major BA in genetic vs acquired NICM were 10 of 52 vs 12 of 51, and 10 of 52 vs 4 of 51, respectively (both p=n.s.). However, MVA occurred more frequently in LMNA-NICM (eight of 23 vs two of 29 hypertrophic, p=0.015) and in previous myocarditis (nine of 21 vs three of 30 acute, p=0.016), while major BAs were particularly common in LMNA-NICM patients only (nine of 23 vs one of 29 hypertrophic, p=0.003). Different patterns of septal LGE were consistently retrospectively identified at baseline CMR: junctional and limited to the base in 79.3% of uneventful hypertrophic NICM; extended and focally transmural in LMNA-NICM with follow-up arrhythmias (both p<0.05); transitory in patients with acute myocarditis, who, differently from the post-myocarditis ones, showed follow-up arrhythmias only in the presence of unmodified LGE at follow-up CMR (five of 13, p=0.009). CONCLUSION: Septal LGE was significantly associated with MVA at the 5-year follow-up in LMNA-NICM or previous myocarditis, and with major BA in LMNA-NICM only. These differences correlated with heterogeneous patterns of IVS LGE in different NICM.
Assuntos
Arritmias Cardíacas/diagnóstico , Cardiomiopatias/diagnóstico , Gadolínio/farmacologia , Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Septo Interventricular/diagnóstico por imagem , Adulto , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Cardiomiopatias/etiologia , Cardiomiopatias/fisiopatologia , Meios de Contraste/farmacologia , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Fatores de TempoRESUMO
BACKGROUND: Implantation of the MICRA Leadless pacemaker requires the use of a 27 French introducer, blunt delivery system and device fixation to the myocardium via nitinol tines. While prior studies have proven its safety, it is unclear whether performing this procedure with uninterrupted anticoagulation exposes patients to increased risks. We sought to investigate the feasibility and safety of continuing therapeutic anticoagulation during the periprocedural period. METHODS: We evaluated all patients undergoing MICRA placement at our institution between April 2014 and August 2018 with complete follow-up data (n = 170). Patients were stratified into two groups: those on active anticoagulation (OAC, n = 26), defined as having an International normalized ratio >2.0 or having continued a direct oral anticoagulant, and those not anticoagulated (Off-OAC, n = 144). We evaluated for a composite outcome of all major complications, including access site complications and pericardial effusion. RESULTS: OAC and Off-OAC groups had similar mean age (74 ± 13 vs 75 ± 13 years; P = .914). The OAC group had a nonsignificantly lower prevalence of end-stage renal disease (8% vs 17%; P = .375) and aspirin use (27% vs 47%; P = .131). Those in the OAC group were more likely to be on warfarin than those in the Off-OAC group (81% vs 30%; P < .001). The rate of the composite endpoint was similar between the OAC and Off-OAC groups (3.8 % vs 1.4%, respectively; P = .761). Length of stay was similar between groups (1.3 ± 2.6 vs 2.3 ± 3.4 days; P = 0.108). CONCLUSION: Continuation of therapeutic anticoagulation during MICRA implantation appears to be feasible, safe and associated with shorter hospitalization among appropriately selected individuals.