1.
Eur J Trauma Emerg Surg ; 50(3): 1111-1118, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38226990

RESUMO

PURPOSE: Calcaneal fractures (CFs) are rare but potentially debilitating injuries. Apart from the open, far lateral or sinus tarsi approach, operative treatment can be performed minimally invasive and percutaneously with intramedullary nailing. In this study, we sought to investigate the functional outcome of severe CFs treated with the C-Nail® implant. METHODS: Twenty-two CFs (9 × Sanders III and 8 × Sanders IV), operated between 2016 and 2019, were followed up with a mean duration of 36 (± 11) months. The AOFAS score, pre- and postoperative Böhler angles, wound healing disorders, and patient-reported outcome measures (PROMs) like pain levels and return to work/sport levels were assessed. RESULTS: The mean AOFAS score was 72.0 (± 9.8). Four patients sustained wound healing disorders, yet no implant-associated surgical revision was required. Fifty percent of patients were pain-free within 1 year. Within 1 year, about 50% of the patients could return to sports, and about 80% of the patients could return to work. PROMs and functional results align with those from other implants reported in the literature. CONCLUSION: Intramedullary nailing of severe CFs with the C-Nail® implant can be considered a safe treatment alternative that yields acceptable results at mid-terms.


Assuntos
Calcâneo , Fixação Intramedular de Fraturas , Fraturas Ósseas , Humanos , Calcâneo/lesões , Calcâneo/cirurgia , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Masculino , Feminino , Adulto , Fraturas Ósseas/cirurgia , Seguimentos , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Pinos Ortopédicos , Resultado do Tratamento , Volta ao Esporte , Recuperação de Função Fisiológica , Estudos Retrospectivos
2.
Orthop Traumatol Surg Res ; 109(1): 103467, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36999994

RESUMO

BACKGROUND: Surgery for displaced intra-articular calcaneal fractures (DIACFs) is often followed by skin complications that adversely impacts the functional outcomes. Minimally invasive techniques have been developed to decrease the risk of skin complications. The objective of this study was to compare C-Nail® locking-nail fixation to conventional plate fixation for DIACFs. HYPOTHESIS: C-Nail® fixation restores calcaneal anatomy similarly to conventional plate fixation and decreases the frequency of skin complications compared to conventional plate fixation, while providing satisfactory functional outcomes. MATERIAL AND METHODS: In this case-control study of DIACFs, fixation was with a non-locking plate in 30 patients treated between January 2016 and June 2017 and with the C-Nail® in 25 patients treated between April 2017 and April 2018. Computed tomography was performed before surgery then bilaterally after surgery for measurements of the following calcaneal parameters: height, length, width, joint-surface step-off and inter-fragmentary distance. The values of these parameters were compared between the two groups. Postoperative skin complications were recorded. The functional outcome was assessed by determining the AOFAS score 1 year after the injury. RESULTS: The two groups showed no significant differences for age, sex or fracture type. Wound healing was delayed in 3 patients in the plate group. The mean postoperative values of the calcaneal parameters were not significantly different between the two groups. The mean AOFAS score was 85.3±10.4 (range, 50-100) in the plate group and 87.0±12.0 (range, 64-100) in the C-Nail® group (p>0.05). DISCUSSION: Minimally invasive C-Nail® fixation provides similar restoration of calcaneal anatomy as does conventional plate fixation. LEVEL OF EVIDENCE: III, retrospective case-control study.


Assuntos
Traumatismos do Tornozelo , Calcâneo , Traumatismos do Pé , Fraturas Ósseas , Fraturas Intra-Articulares , Humanos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos , Estudos de Casos e Controles , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas Ósseas/etiologia , Calcâneo/diagnóstico por imagem , Calcâneo/cirurgia , Calcâneo/lesões , Placas Ósseas , Traumatismos do Pé/etiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento , Fraturas Intra-Articulares/cirurgia
3.
J Pers Med ; 13(4)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37108973

RESUMO

The C-Nail® system is a novel intramedullary fixation method for displaced intra-articular calcaneal fractures. The aim of this study was to evaluate the biomechanical performance of the C-Nail® system and compare it with conventional plate fixation for the treatment of displaced intra-articular calcaneal fractures using finite element analysis. The geometry of a Sanders type-IIB fracture was constructed using the computer-aided design software Ansys SpaceClaim. The C-Nail® system (Medin, Nové Mesto n. Morave, Czech Republic) and the calcaneal locking plate (Auxein Inc., 35 Doral, Florida) and screws were designed according to the manufacturer specifications. Vertical loading of 350 N and 700 N were applied to the subtalar joint surfaces to simulate partial weight bearing and full weight bearing. Construct stiffness, total deformation, and von Mises stress were assessed. The maximum stress on the C-Nail® system was lower compared with the plate (110 MPa vs. 360 MPa). At the bone level the stress was found to have higher values in the case of the plate compared to the C-Nail® system. The study suggests that the C-Nail® system can provide sufficient stability, making it a viable option for the treatment of displaced intra-articular calcaneal fractures.

4.
Injury ; 53(10): 3543-3552, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35810043

RESUMO

Treatment of comminuted intraarticular calcaneal fractures remains controversial and challenging. The aim of this study was to investigate the biomechanical performance of three different methods for fixation of such fractures. Comminuted calcaneal fractures, including Sanders III AB fracture of the posterior facet and Kinner II B fracture of the calcaneocuboid joint (CCJ) articular calcaneal surface, were created in 18 human cadaveric lower legs by osteotomizing. The ankle joint, medial soft tissues and midtarsal bones along with their ligaments were preserved. The specimens were randomized to three groups for fixation with either (1) 2.7 mm variable-angle locking lateral calcaneal plate (Group 1), (2) 2.7 mm variable-angle locking anterolateral calcaneal plate in combination with one 4.5 mm and one 6.5 mm cannulated screws (Group 2), or (3) interlocking calcaneal nail with 3.5 mm screws in combination with three separate 4.0 mm cannulated screws (Group 3). All specimens were biomechanically tested to failure under axial loading in midstance foot position. Each test commenced with a quasi-static compression ramp from 50 to 200 N, followed by progressively increasing cyclic loading at 2 Hz. Starting from 200 N, the peak load of each cycle increased at a rate of 0.2 N/cycle. Interfragmentary movements were captured by motion tracking. In addition, mediolateral X-rays were taken every 250 cycles with a triggered C-arm. Böhler angle after 5000 cycles (1200 N peak load) increased significantly more in Group 1 compared to both other groups (P ≤ 0.020). Varus deformation of 10° between the calcaneal tuberosity and the lateral calcaneal fragments was reached at significantly lower number of cycles in Group 1 compared the other groups (P ≤ 0.017). Both cycles to 10° plantar gapping between the anterior process and the calcaneal tuberosity fragments, and 2 mm displacement at the CCJ articular calcaneal surface revealed no significant differences among the groups (P ≥ 0.773). From a biomechanical perspective, treatment of comminuted intraarticular calcaneal fractures using anterolateral variable-angle locking plate with additional longitudinal screws or interlocked nail in combination with separate transversal screws provides superior stability as opposed to lateral variable-angle locked plating only.


Assuntos
Traumatismos do Tornozelo , Calcâneo , Fixação Intramedular de Fraturas , Fraturas Ósseas , Fraturas Cominutivas , Fraturas Intra-Articulares , Traumatismos do Joelho , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Calcâneo/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/cirurgia , Humanos , Fraturas Intra-Articulares/diagnóstico por imagem , Fraturas Intra-Articulares/cirurgia