Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Eur J Oral Sci ; 132(2): e12967, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38105518

RESUMO

The aim of the study was to evaluate the effects of erosion and abrasion on resin-matrix ceramic CAD/CAM materials [CERASMART (GC); VITA ENAMIC (VITA Zahnfabrik); Lava Ultimate (3 M)] in comparison to feldspar ceramic (VITABLOCS Mark II, VITA Zahnfabrik) and resin composite materials (ceram.x universal, Dentsply Sirona). Daily brushing and acid exposure were simulated using a brushing apparatus and a solution of 0.5 vol% citric acid. Microhardness, surface roughness, and substance loss were measured at baseline and after simulation of 1 and 3 years of function. All materials showed a decrease in microhardness after 3 years and an increase in surface roughness (Ra) after 1 and 3 years. The Ra increase was statistically significantly lower for the resin-matrix ceramics than for feldspar ceramic and similar to composite material. After 3 years, only feldspar ceramic showed no significant substance loss. In conclusion, resin-matrix ceramics demonstrate reduced roughening compared to feldspar ceramics, potentially improving restoration longevity by preventing plaque buildup, but differences in abrasion resistance suggest the need for further material-specific research. Future research should aim to replicate clinical conditions closely and to transition to in vivo trials.


Assuntos
Cerâmica , Porcelana Dentária , Compostos de Potássio , Propriedades de Superfície , Teste de Materiais , Resinas Compostas , Silicatos de Alumínio , Desenho Assistido por Computador , Materiais Dentários
2.
J Esthet Restor Dent ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39076158

RESUMO

OBJECTIVE: To evaluate the effect of polishing and bleaching on the recovery of lightness, color, whiteness, and relative translucency parameter (RTP) in CAD/CAM materials and changes in these properties when another staining in coffee was conducted after the treatments. MATERIALS AND METHODS: Disks of Lava Ultimate (LU), Vita Enamic (VE), IPS Empress CAD (EMP), IPS e.max CAD (EMAX), and Vita Suprinity (VS) were (1) not treated (control), (2) polished with Proxyt or (3) Ceramisté, (4) bleached with Opalescence PF or (5) Whiteness HP Blue, and (6) air polished with Clinpro Prophy Powder. CIE L*a*b* color coordinates were registered at baseline (R0), after staining with coffee for 30 min daily for 36.5 days and treatment (R1), and after another staining (R2). Differences (R1-R0 and R2-R0) in lightness (ΔL00), color (ΔE00), RTP (ΔRTP00), and whiteness (ΔWID) were evaluated by mixed repeated measures ANOVA and 95% confidence intervals (α = 0.05) and interpreted in function of their respective 50:50% PT and AT thresholds. Topography was evaluated by scanning electron microscopy (SEM). RESULTS: In LU, Opalescence PF and Proxyt decreased Δ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {\mathrm{R}}_0\right)} $$ , and ΔWI D R 1 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_1\hbox{--} {R}_0\right)} $$ and showed lower Δ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , and ΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ . In VE, all treatments decreased Δ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , and ΔWI D R 1 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_1\hbox{--} {R}_0\right)} $$ , whereas Δ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , and ΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ were lower in Opalescence PF than in the control group. In both moments, ΔE00 and ΔWID in EMP (also ΔL00) and EMAX were higher in Opalescence PF than in the control group, from which the other treatments did not differ in R1-R0. In EMP, Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ in Whiteness HP Blue (also Δ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ ) and Proxyt were also higher in comparison to the control group and in VS, Ceramisté decreased Δ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , and Δ R T P 00 R 1 - R 0 $$ \varDelta RT{P}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , whereas Opalescence PF increased ΔRTP 00 R 1 - R 0 $$ {\Delta \mathrm{RTP}}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ . Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ of Ceramisté and ΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ and Δ R T P 00 R 2 - R 0 $$ \varDelta RT{P}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ of Proxyt were lower than those of the control group. CONCLUSIONS: The most suitable treatment to recover the lightness, color, whiteness, and RTP without changing these properties after another coffee exposure is material-dependent. CLINICAL SIGNIFICANCE: Although the effectiveness of the treatment was material-dependent, Proxyt was the only treatment that promoted clinically acceptable changes for both LU and VE, while for purely ceramic materials, this condition was observed with Ceramisté and Clinpro Prophy Powder.

3.
BMC Oral Health ; 24(1): 444, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609958

RESUMO

BACKGROUND: This study evaluated the shear bond strength (SBS) of two different polyetheretherketone (PEEK) and CAD-CAM materials after aging. METHODS: A total of 42 frameworks were designed and milled from 2 different PEEK discs (Copra Peek, P and BioHPP, B). P and B frameworks were divided into 3 subgroups (n = 7). 14 slices were prepared each from feldspathic ceramic (Vitablocs Mark II, VM), hybrid nanoceramic (Cerasmart, CS), and polymer-infiltrated ceramic (Vita Enamic, VE) blocks. After surface preparations, the slices were cemented to P and B surfaces. The samples were subjected to thermal aging (5000 cycles). SBS of all the samples was measured. Fractured surfaces were examined by SEM/EDX analysis. The Shapiro-Wilk, Two-way Robust ANOVA and Bonferroni correction tests were used to analyze the data (a = .05). RESULTS: Frameworks, ceramics, and frameworks x ceramics had significant differences (p < 0.05). The highest SBS value was seen in B-VM (p < 0.05). VM offered the highest SBS with both P and B. The differences between P-VM, P-CS, P-VE and B-CS and B-VE were insignificant (p > 0.05). According to EDX analysis, ytterbium and fluorine was seen in B content, unlike P. While VM and CS contained fluorine, barium, and aluminum; sodium and aluminum were observed in the VE structure. CONCLUSION: Bonding of P and B with VM offers higher SBS. VM, CS and VE did not make any difference in SBS for P, however VM showed a significant difference for B.


Assuntos
Alumínio , Benzofenonas , Flúor , Polímeros , Humanos , Polietilenoglicóis , Desenho Assistido por Computador , Cetonas
4.
BMC Oral Health ; 24(1): 1065, 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39261857

RESUMO

BACKGROUND: Recently, prosthodontic approaches involve more conservative procedures that include less invasive finish line preparations that use less ceramic thickness. AIM OF THE STUDY: This in vitro study aimed to evaluate the effect of vertical preparation and modified vertical preparation designs on the marginal adaptation and fracture resistance of two types of ceramic crowns using CAD/CAM technology. MATERIALS AND METHODS: Two typodont maxillary first premolars were embedded in acrylic resin. Forty positive replicas of epoxy resin dies were used that were divided into two groups depending on the preparation design (n = 20); Group V (Vertical): dies with feather edge finish line and Group MV (Modified vertical): dies with feather edge finish line, where a reverse shoulder of 1 mm depth was placed on the buccal surface 1.5 mm from the occlusal surface. Each group was further subdivided into two subgroups according to the type of ceramic material (n = 10): Subgroup Va and subgroup MVa for lithium disilicate (e.max CAD) and subgroup Vb and subgroup MVb for zirconia (zolid ht+). Crown restorations were made with CAD-CAM technology. The marginal adaptation was assessed using a stereomicroscope both prior to cementation and after cementation and aging. Fracture resistance was tested with a universal testing machine, and the data were statistically analyzed. RESULTS: Marginal adaptation showed no significant differences between subgroups before or after cementation and aging. Three-way ANOVA indicated that preparation design (p = 0.516) and material (p = 0.269) had no significant effect, but cementation had a significant effect (p < 0.0001) on the marginal adaptation. According to two-way ANOVA test, Subgroup (MVb) showed the highest result followed by subgroup (Vb) and subgroub (MVa) and the least was subgroub (Va). Fracture modes showed no significant differences among the subgroups (p = 0.982). CONCLUSIONS: Marginal adaptation of lithium disilicate and zirconia crowns remained clinically acceptable regardless of preparation design. While the modified vertical preparation with a reverse shoulder notably enhanced the fracture resistance of both materials, with zirconia demonstrating superior fracture resistance compared to lithium disilicate with average values exceeding premolar biting force.


Assuntos
Cerâmica , Desenho Assistido por Computador , Coroas , Adaptação Marginal Dentária , Porcelana Dentária , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Zircônio , Zircônio/química , Porcelana Dentária/química , Humanos , Técnicas In Vitro , Cerâmica/química , Falha de Restauração Dentária , Teste de Materiais , Dente Pré-Molar
5.
J Prosthodont ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39105440

RESUMO

PURPOSE: This study evaluated the effects of artificial saliva and distilled water on the nanoindentation creep of different 3D-printed and milled CAD-CAM resin composites. MATERIAL AND METHODS: Disk-shaped specimens were subtractively fabricated from polymer-infiltrated ceramic network (EN) and reinforced resin composite (B) and additively from resin composite (C) and hybrid resin composite (VS) using digital light processing (DLP). Specimens from each material were divided into two groups according to their storage conditions (artificial saliva or distilled water for 3 months). Creep was analyzed by nanoindentation testing. Statistical analysis was done using two-way ANOVA, one-way ANOVA, Bonferroni post hoc tests, and independent t-test (α = 0.05). RESULTS: The main effects of material and storage conditions, and their interaction were statistically significant on nanoindentation (p < 0.001). Storage condition had the greatest influence (partial eta squared ηP 2 = 0.370), followed by the material (ηP 2 = 0.359), and the interaction (ηP 2 = 0.329). The nanoindentation creep depths after artificial saliva storage ranged from 0.34 to 0.51 µm and from 0.50 to 0.87 µm after distilled water storage. One of the additively manufactured groups had higher nanoindentation creep depths in both storage conditions. CONCLUSIONS: All specimens showed comparable performance after artificial saliva storage, but increased nanoindentation creep after distilled water storage for 3 months. The subtractive CAD-CAM blocks showed superior dimensional stability in terms of nanoindentation creep depths in both storage conditions. Additively manufactured composite resins had lower dimensional stability than one of the subtractively manufactured composites, which was demonstrated as having higher creep deformation and maximum recovery. However, after artificial saliva storage, one of the additively manufactured resins had dimensional stability similar to that of subtractively manufactured.

6.
Odontology ; 111(2): 360-374, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36097129

RESUMO

In the present study are depicted valuable observations for practitioners, obtained from an in vitro study which aims to evaluate the compressive strength of occlusal veneers fabricated from 3 type of restorative materials, before and after 1 month of acidic artificial saliva exposure (pH = 2.939). In this context, 90 extracted human molars were prepared to receive computer-aided design/computer-aided manufacturing (CAD/CAM) occlusal veneers. The restorative materials considered in this study were: Cerasmart; Straumann Nice and Tetric CAD. The occlusal veneers were designed, milled and cemented with an adhesive dual-cure resin cement. From all the extracted human molars, only sixty specimens were immersed in acidic artificial saliva, for 1 month, at 37 °C ± 1 °C and part of this specimens were also thermo-cycled, between 5 and 55 °C ± 2 °C, before compressive strength test. The results showed a lower compressive strength for both the samples exposed to acidic artificial saliva as well as for the samples exposed to acidic artificial saliva and thermo-cycled. Scanning electron microscopy (SEM) showed that after compressive strength, all the specimens non-exposed to acidic artificial saliva, present extensive cracks formation at the surface of the restorations, and after exposure to acidic artificial saliva for 1 month, the surface damage was characterized by longitudinal and profound fractures of the restoration, as well as the fracture of the tooth structure. Between CAD/CAM materials tested, nanoceramic resin shows more favorable fracture patterns, both before and after acidic artificial saliva exposure.


Assuntos
Cerâmica , Porcelana Dentária , Humanos , Força Compressiva , Saliva , Saliva Artificial , Teste de Materiais , Materiais Dentários , Desenho Assistido por Computador , Análise do Estresse Dentário
7.
BMC Oral Health ; 23(1): 579, 2023 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-37598167

RESUMO

BACKGROUND: Computer-aided design and computer-aided manufacturing (CAD-CAM) materials for prosthetic is gaining popularity in dentistry. However, limited information exists regarding the impact of thickness and roughening treatment on the optical properties of contemporary CAD-CAM restorative materials. This study aimed to quantitatively evaluate the translucency and opalescence of six dental CAD-CAM materials in response to different thicknesses and roughening treatments. METHODS: Six dental CAD-CAM materials, lithium disilicate glass-ceramic (IPS e.max CAD, LS), polymer-infiltrated ceramic (VITA Enamic, VE), resin-nano ceramic glass-ceramic (LAVA Ultimate, LU), polymethyl methacrylate (Telio CAD, TE), and two zirconia reinforced lithium silicate (VITA Suprinity, VS, and Celtra Duo, CD), in shade A2 were prepared as 12 × 12mm2 specimens of four thicknesses (0.5mm, 1.0mm, 1.5mm, and 2.0mm) (N = 240, n = 10). After three different treatments (polished, roughened by SiC P800-grit, and SiC P300-grit), the translucency parameter (TP00) and opalescence parameter (OP) were measured with a spectrophotometer (VITA Easyshade V). The surface roughness was analyzed with a shape measurement laser microscope. The data were analyzed using a MANOVA, post hoc Tukey-Kramer test, the t test, and regression analysis (α = .05). RESULTS: The TP00 and OP were significantly influenced by material type, thickness and roughening treatment (P < .05). TP00 showed a continues decline with increasing thicknesses, while the variations of OP were material-dependent. TP00 ranged from 37.80 (LS in 0.5mm) to 5.66 (VS in 2.0mm), and OP ranged from 5.66 (LU in 0.5mm) to 9.55 (VS in 0.5mm). The variations in TP00 of all materials between adjacent thicknesses ranged from 2.10 to 15.29, exceeding the acceptable translucency threshold except for LU. Quadratic and logarithmic regression curves exhibited the best fit for TP00 among the materials. Compared to polished specimens, rougher specimens exhibited lower TP00 and higher OP in all materials except for LS (P < 0.05). Roughening with P300-grit decreased TP00 and OP by an average of 2.59 and 0.43 for 0.5mm specimens, and 1.26 and 0.25 for 2.0mm specimens, respectively. CONCLUSIONS: Variations in translucency caused by thickness and roughening treatment were perceptible and may be clinically unacceptable. Careful consideration should be given to the selection of CAD-CAM materials based on their distinct optical properties.


Assuntos
Iridescência , Projetos de Pesquisa , Humanos , Desenho Assistido por Computador , Materiais Dentários/uso terapêutico , Microscopia Confocal
8.
Odontology ; 109(1): 259-270, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32705420

RESUMO

To compare the 1-year clinical performance of lithium disilicate and resin composite CAD/CAM onlay restorations. Twenty patients that required two restorations in posterior teeth, with at least one cusp to be covered, received two onlays. One was made with IPS e.max CAD (Ivoclar-Vivadent) and the other with Lava Ultimate (3M Oral Care). Two blind observers evaluated the restorations at baseline and 1 year after the onlays were cemented, according to FDI criteria. At each recall, digital photographs, bite-wing radiographs and impressions of the restorations were taken for SEM evaluation of the interface. Results were analyzed by Mann-Whitney U and Wilcoxon tests (p < 0.05). At baseline and in the 1-year recall, both CAD/CAM materials exhibited excellent results in most criteria with similar esthetic, functional and biological properties (p > 0.05). However, deterioration in surface lustre (p = 0.020) and color match/translucency (p = 0.039) were detected for IPS e.max CAD onlays after 1-year. Under SEM evaluation, there were no statistically differences in micromorphological criteria at baseline nor after a year between IPS e.max CAD and Lava Ultimate onlays. Conclusion: After 1 year of clinical service IPS e.max CAD and Lava Ultimate onlays showed a similar clinical performance that needs to be confirmed in long-term evaluations.


Assuntos
Cerâmica , Restaurações Intracoronárias , Desenho Assistido por Computador , Porcelana Dentária , Humanos , Teste de Materiais
9.
J Esthet Restor Dent ; 31(1): 88-92, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30302898

RESUMO

OBJECTIVE: While the radiopacity of restorative material affects the radiographic diagnosis of the teeth, there is no data about the radiopacity of current restorative computer-aided design (CAD)/computer-aided manufacturing (CAM) materials. Therefore, the present study compared the radiopacity values of current restorative CAD/CAM blocks to facilitate the material choice within such a wide variety of materials. MATERIALS AND METHODS: Specimens were prepared from 13 different restorative CAD/CAM blocks to compare with enamel and dentin. The specimens placed on the occlusal phosphor plate were imaged with aluminum step wedge and tooth section. The radiopacity values were calculated using the Image J program. The radiopacity values of the specimens were converted to mmAl values with the Curve Expert 1.4 program. RESULTS: The difference between the radiopacity values of dentin and e.max CAD was not significant, however, they exhibited a significant difference from the other 14 groups (P < .05). Enamel and Obsidien, Suprinity, and Celtra Duo had greater radiopacity values with significant differences from the other 12 materials whereas the difference within these groups was not significant (P > .05). CONCLUSIONS: The evaluated restorative CAD/CAM materials have significantly different radiopacity values. Among these permanent restoration blocks, the highest radiopacity value was observed in Celtra Duo, the lowest in Block HC. CLINICAL SIGNIFICANCE: Cerasmart, Lava Ultimate, Obsidian, Vita Suprinity, Celtra Duo Blocks have adequate radiopacity for inlay, onlay and crown restorations, however, the use of Vita Enamic, Vita Mark II, GC LRF blocks and the others which have lower radiopacity value than dentin for the same kind of restorations depend on the radiopacity of the luting cement for the purpose of recurrent caries detection.


Assuntos
Porcelana Dentária , Intensificação de Imagem Radiográfica , Cerâmica , Desenho Assistido por Computador , Coroas , Materiais Dentários , Teste de Materiais , Propriedades de Superfície
10.
Int J Mol Sci ; 19(9)2018 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-30208663

RESUMO

New zirconia-reinforced lithium silicate ceramics (ZLS) could be a viable alternative to zirconium (Y-TZP) in the manufacture of implantological abutments-especially in aesthetic cases-due to its good mechanical, optical, and biocompatibility properties. Although there are several studies on the ZLS mechanical properties, there are no studies regarding proliferation, spreading, or cytomorphometry. We designed the present study which compares the surface, cellular proliferation, and cellular morphology between Y-TZP (Vita YZ® T [Vita Zahnfabrik (Postfach, Germany)]) and ZLS (Celtra® Duo [Degudent (Hanau-Wolfgang, Germany)]). The surface characterization was performed with energy dispersive spectroscopy (EDS), scanning electron microscopy (SEM), and optical profilometry. Human gingival fibroblasts (HGFs) were subsequently cultured on both materials and early cellular response and cell morphology were compared through nuclear and cytoskeletal measurement parameters using confocal microscopy. The results showed greater proliferation and spreading on the surface of Y-TZP. This could indicate that Y-TZP continues to be a gold standard in terms of transgingival implant material: Nevertheless, more in vitro and in vivo research is necessary to confirm the results obtained in this study.


Assuntos
Materiais Biocompatíveis/química , Fibroblastos/citologia , Gengiva/citologia , Lítio/química , Silicatos/química , Zircônio/química , Linhagem Celular , Movimento Celular , Proliferação de Células , Cerâmica/química , Humanos , Teste de Materiais , Próteses e Implantes , Propriedades de Superfície
11.
J Prosthodont ; 27(8): 748-754, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27880011

RESUMO

PURPOSE: To evaluate the bond strength of repair systems (Ceramic Repair, Clearfil Repair) to computer-aided design/computer-assisted machining (CAD/CAM) restorative materials (IPS e.max CAD, Vita Suprinity, Vita Enamic, Lava Ultimate). MATERIALS AND METHODS: Thermally aged CAD/CAM restorative material specimens (5000 cycles between 5°C and 55°C) were randomly divided into two groups according to the repair system: Ceramic Repair (37% phosphoric acid + Monobond-S + Heliobond + Tetric N Ceram) or Clearfil Repair (40% phosphoric acid + mixture of Clearfil Porcelain Bond Activator and Clearfil SE Bond Primer + Clearfil SE Bond + Filtek Z250). The resin composite was light-cured on conditioned specimens. All specimens were stored in distilled water at 37°C for 24 hours and then additionally aged for 5000 thermal cycles. The shear bond strength test was performed using a universal testing machine (0.5 mm/min). Two-way ANOVA was used to detect significance differences according to the CAD/CAM material and composite repair system factors. Subgroup analyses were conducted using the least significant difference post-hoc test. RESULTS: The results of two-way ANOVA indicated that bond strength values varied according to the restorative materials (p < 0.05). No significant differences were observed between the CAD/CAM restorative materials (p > 0.05), except in the Vita Suprinity group (p < 0.05). Moreover, no differences were observed between the repair systems. CONCLUSIONS: Both the Clearfil and Ceramic repair systems used in the study allow for successful repairs.


Assuntos
Desenho Assistido por Computador , Colagem Dentária , Planejamento de Prótese Dentária , Reparação de Restauração Dentária/métodos , Cerâmica/uso terapêutico , Porcelana Dentária/uso terapêutico , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Cimentos de Resina/uso terapêutico , Resistência ao Cisalhamento
12.
Odontology ; 105(2): 162-169, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27456684

RESUMO

To evaluate the stain susceptibility of CAD/CAM blocks and direct composite after long term exposure to various staining agents. 40 disk-shaped samples were fabricated from each of nine materials; six CAD/CAM (Vitablocs Mark II, Paradigm MZ100, Experimental Vita Hybrid Ceramic, Vita Enamic, Experimental Kerr and Lava Ultimate) and three direct composites (Filtek Supreme, Venus Diamond and Filtek Silorane). Samples were randomly divided into five groups (n = 8) according to different staining solutions (distilled water, tea, red wine, coffee and artificial saliva). Initial L*a*b* values were assessed using a calibrated digital spectrophotometer. Specimens were immersed in staining solutions and stored in an incubator at 37 °C for 120 days. L*a*b* values were assessed again and color change (∆E) was calculated as difference between recorded L*a*b* values. ANOVA, and Duncan test were used to identify differences between groups (α = 0.05). Significant differences in ∆E values were detected between materials (p = 0.000). Among all staining solutions, the highest ∆E value was observed with red wine. The new CAD/CAM blocks (Vita Enamic, Vita Hybrid Ceramic and Lava Ultimate) showed the highest resistance to staining compared to the MZ100 composite resin blocks. Filtek Silorane, a direct composite, showed high stain resistance values compared to CAD/CAM materials and other direct composites. Ceramic and composite CAD/CAM blocks had lower staining susceptibility than methacrylate based direct composite. Staining susceptibility of the new resin based CAD/CAM materials Vita Enamic and Lava Ultimate was comparable to feldspathic ceramic blocks (Vitablocs Mark II). Filtek Silorane showed promising results that were comparable to some CAD/CAM blocks.


Assuntos
Resinas Compostas/química , Porcelana Dentária/química , Descoloração de Dente , Cerâmica , Desenho Assistido por Computador , Técnicas In Vitro , Teste de Materiais , Resinas de Silorano , Propriedades de Superfície , Zircônio
13.
J Appl Biomater Funct Mater ; 22: 22808000241235994, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38420920

RESUMO

OBJECTIVE: To evaluate the effect of different CAD/CAM materials and occlusal thicknesses on the fracture resistance of primary molar crowns. METHODS: Sixty extracted primary molar teeth were prepared and randomly divided into six experimental groups according to the material and thickness. Primary molar crowns with a central groove thickness of 0.3 and 0.5 mm were fabricated from CAD/CAM zirconia (group Z), zirconia-reinforced lithium silicate (group ZLS), and pre-polymerized composite resin blocks (group C). Each crown was cemented with self-adhesive resin cement on the prepared tooth. All specimens were subjected to fracture tests until fracture. Fracture load values were recorded in Newtons (N). Data were statistically analyzed using a two-way analysis of variance (ANOVA) followed by Tukey multiple comparison test. RESULTS: The highest fracture load values were obtained in group Z at 0.5 mm occlusal thickness and were significantly higher compared with the other experimental groups (p < 0.05). Although the lowest fracture load values were obtained in group ZLS at 0.3 mm occlusal thickness, all the tested CAD/CAM primary molar crowns at both thicknesses demonstrated fracture load values exceeding reported chewing force in pediatric patients. CONCLUSION: CAD/CAM primary molar crowns with reduced occlusal thickness may be used for the full-coverage restoration of primary molar teeth.


Assuntos
Coroas , Zircônio , Humanos , Criança , Teste de Materiais , Desenho Assistido por Computador , Porcelana Dentária , Cerâmica , Planejamento de Prótese Dentária
14.
J Dent ; 144: 104952, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38508442

RESUMO

OBJECTIVES: Evaluation of the two-body wear of lithium-silicate ceramics against different antagonists compared to a direct resin composite and human teeth. METHODS: Initial LiSi Block [LISI], IPS e.max CAD [EMA], and CEREC Tessera [TESE] were investigated and compared with direct resin composite [FILL] and human teeth [tooth]. As antagonists were used: steatite, ceramic, and human enamel. The control group tooth was only tested with enamel antagonist. The combinations underwent thermomechanical aging using a chewing simulator. Material losses were calculated using GOM-analysis software. Kolmogorov-Smirnov test, Kruskal-Wallis H, Mann-Whitney-U-test with Bonferroni correction and Spearman-rho correlation were calculated. A fractographic analysis was performed. RESULTS: Within TESE, enamel antagonists led to lower restoration losses than steatite and ceramic antagonists. Within FILL, enamel and steatite antagonists caused lower material losses compared to ceramic antagonists. Against steatite antagonists, LISI showed lowest material losses. Against ceramic antagonists, the use of LISI led to lower material losses compared to FILL. Against tooth antagonists, TESE showed lower material losses than tooth and FILL and LISI lower than FILL. Within LISI, steatite antagonists showed lower material losses on the antagonist than ceramic. Within EMA, steatite antagonists showed higher material losses than ceramic ones. Within ceramic antagonists, LISI restoration material showed lower material losses than FILL and EMA. CONCLUSIONS: Regardless of the antagonist material, the material losses of LISI and EMA were comparable. However, the abrasion resistance of LISI tended to be higher than EMA. CLINICAL SIGNIFICANCE: LISI is a fully crystallized lithium-silicate ceramic and no longer needs to be processed after milling. In addition, the abrasion resistance is very good, regardless of the antagonist material chosen.


Assuntos
Cerâmica , Resinas Compostas , Esmalte Dentário , Porcelana Dentária , Óxido de Magnésio , Teste de Materiais , Dióxido de Silício , Humanos , Resinas Compostas/química , Porcelana Dentária/química , Esmalte Dentário/efeitos dos fármacos , Cerâmica/química , Materiais Dentários/química , Silicatos/química , Propriedades de Superfície , Desgaste de Restauração Dentária , Desenho Assistido por Computador , Lítio
15.
Materials (Basel) ; 17(6)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38541399

RESUMO

The aim of this study was to compare the influence of heat treatment on fracture resistance (FR) of different ceramic materials used for CAD/CAM systems. METHODS: Eighty monolithic restorations were designed using the same parameters and milled with a CAD/CAM system (CEREC SW 5.0, PrimeMill, Dentsply-Sirona™, Bensheim, Germany), forming five study groups: Group 1 (n = 10), CEREC Tessera (Dentsply-Sirona™, Bensheim, Germany) crystallized (CCT), Group 2 (n = 10), CEREC Tessera uncrystallized (UCT), Group 3 (n = 20), Emax-CAD (Ivoclar Vivadent, Schaan, Liechtenstein) (CEC), Group 4 (n = 20), Vita Suprinity (Vita Zahnfabrik, Bad Säckingen, Germany) (CVS), and Group 5 (n = 20) Cameo (Aidite, Qinhuangdao, China) (CC). RESULTS: The average FR was similar for CCT, CC, and CEC at above 400 N, while CVS and UCT had the lowest values at 389,677 N and 343,212 N, respectively. CONCLUSION: Among the three ceramic materials that exhibited an FR above 400 N, CCT was considered the first recommended choice for CAD/CAM systems. This material not only demonstrated the highest FR but also exhibited outstanding consistency in the related measurements without the presence of outliers. Although the CC material showed high FR, its high dispersion revealed inconsistencies in the repetitions, suggesting caution in its use.

16.
Materials (Basel) ; 17(13)2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38998243

RESUMO

Dental technology has developed materials for prosthetics that are very similar to natural teeth and offer a good balance between durability and esthetics; however, some of these materials are not very color-stable under the influence of external factors. Therefore, the aim of this study is to determine and compare the color change (∆E00) of different esthetic monolithic monochromatic CAD/CAM materials after they have been thermocycled and treated with staining solutions. The color parameters were determined using a spectrophotometer on a white and black background. Five CAD/CAM materials were used for this study-CAD/CAM nanoceramic (GC Cerasmart270), CAD/CAM lithium disilicate ceramic (IPS e.max CAD), CAD/CAM polymer (Telio CAD), CAD/CAM composite (Tetric CAD) and CAD/CAM polymer-infiltrated ceramic (Vita Enamic). The test specimens produced were divided into groups and were thermocycled in distilled water. They were then stored for four weeks at 37 °C in either distilled water as a control liquid, black tea, instant coffee or red wine. The aim is also to evaluate the color changes as a function of the exposure time of the staining solutions. The results obtained were analyzed statistically. All CAD/CAM materials tend to discolor to varying degrees. Among the factors contributing to discoloration, red wine proved to be the most significant influencing factor. The conclusion from the results is that the color change is influenced by the type of material, the staining solution, the sample thickness, the color background and the aging time.

17.
Dent Mater ; 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39327131

RESUMO

OBJECTIVES: To evaluate and compare the optical properties and relative translucency parameter of CAD-CAM restorative materials. METHODS: Four CAD-CAM materials were evaluated: Lava Ultimate (LU), Grandio Blocs (GB), VITA Enamic (VE), and VITA Mark II (VM). Disk-shaped samples in shade A2-HT were prepared (n = 10) and polished to 1.00 ± 0.01 mm of thickness. Scattering (S), absorption (K), albedo (a) coefficient, transmittance (T%), light reflectivity (RI), infinite optical thickness (X∞), and radiative transfer coefficients (µa, and µ'S) were calculated using Kubelka-Munk method and Thennadil's semi-empirical approach. Root Mean Square Error (RMSE) and Goodness of Fit (GFC) were used as performance optical behavior. Translucency differences were evaluated using the relative translucency parameter (RTP00) and 50:50 % translucency perceptibility and acceptability thresholds (TPT00 and TAT00). RESULTS: The spectral distribution of S, K, T%, RI, and X∞ was wavelength-dependent. GFC and RMSE values indicated good spectral behavior matches and good comparative spectral values for RI in LU-GB, LU-VE, and GB-VE, and for K in VE-VM. VM displayed the highest scattering values across the wavelengths, while VE and VM showed lower absorption at shorter wavelengths. LU and GB had the highest transmittance. The X∞ values indicated that all 1.0 mm thick materials could be influenced by the background. No good spectral match and no good comparative spectral values were found between CAD-CAM materials and anterior bovine maxillary specimens. VM had the lowest RTP00 values with perceptible and unacceptable differences compared to CAD-CAM materials evaluated. SIGNIFICANCE: Understanding the optical behavior of different CAD-CAM materials was essential for guiding clinicians in material selection and optimizing their clinical performance. The findings confirm that the different compositions and microstructure impact the optical properties and translucency of CAD-CAM restorative materials.

18.
J Appl Biomater Funct Mater ; 22: 22808000241248886, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38678374

RESUMO

OBJECTIVE: To evaluate the effect of COVID-19 preventive mouthwashes on the surface hardness, surface roughness (Ra), and color change (ΔE) of three different polymer-based composite CAD/CAM materials (Vita Enamic (ENA), Grandio Block (GB), Lava Ultimate (LU)). METHODS: A total of 100 rectangular-shaped specimens with dimensions of 2 mm × 7 mm × 12 mm were obtained by sectioning three different CAD/CAM blocks and randomly divided into five subgroups according to the 30 days of mouthwash immersion protocol as follows: Control: artificial saliva, PVP-I: 1% povidone-iodine, HP: 1.5% hydrogen peroxide, CPC: mouthwash containing 0.075% cetylpyridinium chloride, EO: mouthwash containing essential oils. Microhardness, Ra, and ΔE values were measured at baseline and after 30 days of immersion protocols. Data were analyzed using the Wald Chi-square, two-way ANOVA, and post hoc Tukey tests. RESULTS: The independent factors (materials and solutions) significantly influenced the microhardness and color (p < 0.001). Ra of the materials was not affected by any of the mouthwashes (p > 0.05). The microhardness and color of each material varied significantly after immersion in PvP-I and HP (p < 0.05). The highest percentage change in microhardness, Ra, and ΔE was found in LU immersed in PvP-I and HP mouthwashes, while the lowest change was found in ENA groups (p < 0.05). CONCLUSION: Within the limitations of this study, it was found that the surface hardness and color of tested polymer-based composite CAD/CAM materials are susceptible to degradation and change after 30 days of immersion in 1% PvP-I and 1.5% HP mouthwashes.


Assuntos
Antivirais , Cerâmica , Dureza , Antissépticos Bucais , Propriedades de Superfície , Antissépticos Bucais/química , Antivirais/química , Cor , Teste de Materiais , Cetilpiridínio/química , Resinas Compostas/química , Humanos , Desenho Assistido por Computador , COVID-19 , Povidona-Iodo/química , Peróxido de Hidrogênio/química
19.
J Funct Biomater ; 14(8)2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37623675

RESUMO

Clinical outcomes of dental restorations depend primarily on the choice of materials used, and nowadays, dental CAD-CAM (Computer-Aided Design Computer-Aided Manufacturing) materials have strongly changed daily clinical practice. The aim of this systematic review is to analyze CAD-CAM dental materials according to their mechanical properties and in relation to their clinical applications. A literature review was performed on PubMed, Scopus, Web of Knowledge, and the Cochrane Library. Articles addressing at least one of the following topics regarding dental materials for CAD-CAM systems: manufacturers, mechanical features, materials' composition, optical properties, clinical indications, and/or outcomes were included in the review. A flowchart was performed as described in the PRISMA guidelines. Among the 564 articles found, 63 were analyzed and evaluated. Within the limitations of this systematic review, it can be concluded that CAD-CAM materials present a wide range of clinical applications due to their improved mechanical properties. Specifically, in addition to materials that have been in use for a long time (such as feldspathic ceramics), resin block composites can also be used for permanent restorations.

20.
Materials (Basel) ; 16(18)2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37763547

RESUMO

The development of digital technologies has allowed for the fabrication of new materials; however, it makes it difficult to choose the best methods to obtain occlusal splints with optimal properties, so it is essential to evaluate the effectiveness of these materials. The aim of the study is to compare the fracture resistance of occlusal splints made of different materials after thermo-mechanical aging. METHODS: A total of 32 samples were made from 4 materials (two 3D printed polymeric materials, a PMMA disc for CAD/CAM, and a conventional heat-cured acrylic resin); subsequently, the fracture test was performed using the load compression mode applied occlusally on the splint surface. STATISTICAL ANALYSIS: Four statistical tests were used (Shapiro-Wilk, Levene's test, ANOVA, and Tukey's HSD test). RESULTS: The following study showed that there are differences in fracture strength among the four materials investigated, where the highest strength was observed in the milled splint, with a mean of 3051.2 N (newton) compared to the strength of the flexible splint with 1943.4 N, the printed splint with 1489.9 N, and the conventional acrylic splint with 1303.9 N. CONCLUSIONS: The milled splints were the most resistant to fracture. Of the printed splints, the splint made with flexural rigid resin withstood the applied forces in acceptable ranges, so its clinical indication may be viable. Although the results of this research indicated differences in the mechanical properties between the CAD/CAM and conventional fabrication methods, the selection may also be influenced by processing time and cost, since with a CAD/CAM system there is a significant reduction in the production time of the splint material.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA