Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Sensors (Basel) ; 23(22)2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-38005545

RESUMO

The automotive industry and scientific community are making efforts to develop innovative solutions that would increase successful driver performance in preventing crashes caused by drivers' health and concentration. High stress is one of the causes of impaired driver performance. This study investigates the ability to classify different stress levels based on capacitive electrocardiogram (cECG) recorded during driving by unobtrusive acquisition systems with different hardware implementations. The proposed machine-learning model extracted only four features, based on the detection of the R peak, which is the most reliably detected characteristic point even in inferior quality cECG. Another criterion for selecting the features is their low computational complexity, which enables real-time application. The proposed method was validated on three open data sets recorded during driving: electrocardiogram (ECG) recorded by electrodes with direct skin contact (high quality); cECG recorded without direct skin contact through clothes by electrodes built into a portable multi-modal cushion (middle quality); and cECG recorded through the clothes without direct skin contact by electrodes built into a car seat (lowest quality). The proposed model achieved a high accuracy of 100% for high-quality ECG, 96.67% for middle-quality cECG, and 98.08% for the lower-quality cECG.


Assuntos
Eletrocardiografia , Humanos , Eletrocardiografia/métodos , Eletrodos
2.
Entropy (Basel) ; 24(1)2021 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-35052039

RESUMO

The development of smart cars with e-health services allows monitoring of the health condition of the driver. Driver comfort is preserved by the use of capacitive electrodes, but the recorded signal is characterized by large artifacts. This paper proposes a method for reducing artifacts from the ECG signal recorded by capacitive electrodes (cECG) in moving subjects. Two dominant artifact types are coarse and slow-changing artifacts. Slow-changing artifacts removal by classical filtering is not feasible as the spectral bands of artifacts and cECG overlap, mostly in the band from 0.5 to 15 Hz. We developed a method for artifact removal, based on estimating the fluctuation around linear trend, for both artifact types, including a condition for determining the presence of coarse artifacts. The method was validated on cECG recorded while driving, with the artifacts predominantly due to the movements, as well as on cECG recorded while lying, where the movements were performed according to a predefined protocol. The proposed method eliminates 96% to 100% of the coarse artifacts, while the slow-changing artifacts are completely reduced for the recorded cECG signals larger than 0.3 V. The obtained results are in accordance with the opinion of medical experts. The method is intended for reliable extraction of cardiovascular parameters to monitor driver fatigue status.

3.
Sensors (Basel) ; 15(8): 19237-50, 2015 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-26251913

RESUMO

A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.


Assuntos
Eletrocardiografia/instrumentação , Higroscópicos/química , Processamento de Sinais Assistido por Computador/instrumentação , Eletrodos , Umidade , Polímeros/química , Eletricidade Estática
4.
PeerJ ; 11: e16032, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37692124

RESUMO

Background: Tetanus remains a significant public health issue in China, with the approach of anti-tetanus prophylaxis in the emergency department resulting in both overuse, particularly of human tetanus immune globulin (TIG), and underuse with the tetanus vaccine. This is largely due to the absence of updated guidelines on tetanus prophylaxis before 2018. Our study aimed to evaluate the effects of the 2018 Chinese tetanus guidelines on the knowledge and practices of emergency physicians about tetanus prevention in trauma patients. Methods: From November 2019 to April 2020, we conducted a web-based survey involving 499 emergency physicians. The survey included a questionnaire covering knowledge, attitudes, and practices related to tetanus. We assessed the influence of the 2018 tetanus guidelines on the knowledge and practices of emergency physicians related to tetanus prevention for patients with trauma using multiple regression analysis. Results: The survey results showed that only 45.3% of the participants had received formal training on tetanus immunization, despite 53.3% reporting the availability of tetanus vaccines at their institutions. Physicians typically prescribed tetanus antitoxin or human TIG instead of tetanus toxoid (TT) to treat injuries, regardless of the patient's TT vaccination history. Among the respondents, those who were aware of the 2018 tetanus guidelines had higher mean scores on the general knowledge, risk knowledge, and treatment knowledge scales, with increases of 6%, 13%, and 9%, respectively, compared to those who were unaware of the guidelines. Awareness of the 2018 tetanus guidelines was associated with a high level of knowledge, as indicated by the general knowledge score, recommendation knowledge score, and total knowledge score, after adjusting for the effects of all variables on the knowledge, attitudes, and practices of the participants. A high level of education was also associated with a high level of knowledge indicated by the recommendation knowledge score and total knowledge score. Conclusions: Our study highlights a substantial gap in the attitudes, knowledge, and practices of emergency physicians in China regarding tetanus immunization. The results suggest an urgent need to promote the Chinese Expert Consensus Guidelines on tetanus to improve emergency physicians' knowledge and competence in tetanus prophylaxis. The findings underscore the importance of enhancing physicians' awareness of the latest guidelines to ensure appropriate and effective treatment for patients with tetanus-prone injuries.


Assuntos
Medicina de Emergência , Médicos , Antitoxina Tetânica , Toxoide Tetânico , Tétano , Ferimentos e Lesões , Humanos , Povo Asiático , China/epidemiologia , Antitoxina Tetânica/uso terapêutico , Toxoide Tetânico/uso terapêutico , Guias de Prática Clínica como Assunto , Serviços Médicos de Emergência , Conhecimentos, Atitudes e Prática em Saúde , Medicina de Emergência/normas , Ferimentos e Lesões/complicações , Ferimentos e Lesões/terapia , Tétano/etiologia , Tétano/prevenção & controle , Tétano/terapia
5.
Health Inf Sci Syst ; 3: 2, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26038690

RESUMO

While PhysioNet is a large database for standard clinical vital signs measurements, such a database does not exist for unobtrusively measured signals. This inhibits progress in the vital area of signal processing for unobtrusive medical monitoring as not everybody owns the specific measurement systems to acquire signals. Furthermore, if no common database exists, a comparison between different signal processing approaches is not possible. This gap will be closed by our UnoViS database. It contains different recordings in various scenarios ranging from a clinical study to measurements obtained while driving a car. Currently, 145 records with a total of 16.2 h of measurement data is available, which are provided as MATLAB files or in the PhysioNet WFDB file format. In its initial state, only (multichannel) capacitive ECG and unobtrusive PPG signals are, together with a reference ECG, included. All ECG signals contain annotations by a peak detector and by a medical expert. A dataset from a clinical study contains further clinical annotations. Additionally, supplementary functions are provided, which simplify the usage of the database and thus the development and evaluation of new algorithms. The development of urgently needed methods for very robust parameter extraction or robust signal fusion in view of frequent severe motion artifacts in unobtrusive monitoring is now possible with the database.

6.
Prog Cardiovasc Dis ; 56(2): 195-202, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24215751

RESUMO

Silent ischemia is a common manifestation of coronary artery disease (CAD). Continuous ECG (cECG) monitoring is an effective tool for assessing the frequency and duration of silent ischemic episodes for patients with CAD and for risk stratifying asymptomatic patients or those after an acute coronary syndrome by identifying those at increased risk for future cardiovascular events or death. cECG also allows monitoring of the effectiveness of therapy in patients with CAD. Treatment strategies targeted toward the elimination of silent ischemia have shown that revascularization was better than medical therapy in eliminating silent ischemia, but large scale, prospective studies targeting silent ischemia as a treatment endpoint are still lacking. Future research is warranted to study the effects of newer medical agents or the selected use of revascularization in those patients with persistent silent ischemia despite current medical regiments.


Assuntos
Eletrocardiografia Ambulatorial , Isquemia Miocárdica/diagnóstico , Antagonistas Adrenérgicos beta/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Bloqueadores dos Canais de Cálcio/uso terapêutico , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Humanos , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/terapia , Revascularização Miocárdica , Prognóstico , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA