Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 51(10): 2931-2940, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38243119

RESUMO

BACKGROUND: Cerenkov luminescence imaging (CLI) is a new emerging technology that can be used for optical imaging of approved radiotracers, both in a preclinical, and even more recently, in a clinical context with rapid imaging times, low costs, and detection in real-time (Grootendorst et al. Clin Transl Imaging 4(5):353-66, 2016); Wang et al. Photonics 9(6):390, 2022). This brief review provides an overview of clinical applications of CLI with a focus on intraoperative margin assessment (IMA) to address shortcomings and provide insight for future work in this application. METHODS: A literature review was performed using PubMed using the search words Cerenkov luminescence imaging (CLI), intraoperative margin assessment (IMA), and image-guided surgery. Articles were selected based on title, abstract, content, and application. RESULTS: Original research was summarized to examine advantages and limitations of CLI compared to other modalities for IMA. The characteristics of Cerenkov luminescence (CL) are defined, and results from relevant clinical trials are discussed. Prospects of ongoing clinical trials are reviewed, along with technological advancements related to CLI. CONCLUSION: CLI is a proven method for molecular imaging and shows feasibility for determining intraoperative margins if future work involves establishing quantitative approaches for attenuation and scattering, depth analysis, and radiation safety for CLI at a larger scale.


Assuntos
Imagem Molecular , Humanos , Imagem Molecular/métodos , Medições Luminescentes/métodos , Cirurgia Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia , Período Intraoperatório , Luminescência , Animais
2.
Angew Chem Int Ed Engl ; 63(30): e202401683, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-38719735

RESUMO

Lanthanide nanoparticle (LnNP) scintillators exhibit huge potential in achieving radionuclide-activated luminescence (radioluminescence, RL). However, their structure-activity relationship remains largely unexplored. Herein, progressive optimization of LnNP scintillators is presented to unveil their structure-dependent RL property and enhance their RL output efficiency. Benefiting from the favorable host matrix and the luminescence-protective effect of core-shell engineering, NaGdF4 : 15 %Eu@NaLuF4 nanoparticle scintillators with tailored structures emerged as the top candidates. Living imaging experiments based on optimal LnNP scintillators validated the feasibility of laser-free continuous RL activated by clinical radiopharmaceuticals for tumor multiplex visualization. This research provides unprecedented insights into the rational design of LnNP scintillators, which would enable efficient energy conversion from Cerenkov luminescence, γ-radiation, and ß-electrons into visible photon signals, thus establishing a robust nanotechnology-aided approach for tumor-directed radio-phototheranostics.

3.
Eur J Nucl Med Mol Imaging ; 50(2): 508-524, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36222853

RESUMO

PURPOSE: Photodynamic therapy (PDT) is a promising cancer treatment strategy with rapid progress in preclinical and clinical settings. However, the limitations in penetration of external light and precise delivery of photosensitizers hamper its clinical translation. As such, the internal light source such as Cerenkov luminescence (CL) from decaying radioisotopes offers new opportunities. Herein, we show that goat milk-derived extracellular vesicles (GEV) can act as a carrier to deliver photosensitizer Chlorin e6 (Ce6) and tumor-avid 18F-FDG can activate CL-induced PDT for precision cancer theranostics. METHODS: GEV was isolated via differential ultracentrifugation of commercial goat milk and photosensitizer Ce6 was loaded by co-incubation to obtain Ce6@GEV. Tumor uptake of Ce6@GEV was examined using confocal microscopy and flow cytometry. To demonstrate the ability of 18F-FDG to activate photodynamic effects against cancer cells, apoptosis rates were measured using flow cytometry, and the production of 1O2 was measured by reactive oxygen species (ROS) monitoring kit. Moreover, we used the IVIS device to detect Cherenkov radiation and Cerenkov radiation energy transfer (CRET). For animal experiments, a small-animal IVIS imaging system was used to visualize the accumulation of the GEV drug delivery system in tumors. PET/CT and CL images of the tumor site were performed at 0.5, 1, and 2 h. For in vivo antitumor therapy, changes of tumor volume, survival time, and body weight in six groups of tumor-bearing mice were monitored. Furthermore, the blood sample and organs of interest (heart, liver, spleen, lungs, kidneys, and tumor) were collected for hematological analysis, immunohistochemistry, and H&E staining. RESULTS: Confocal microscopy of 4T1 cells incubated with Ce6@GEV for 4 h revealed strong red fluorescence signals in the cytoplasm, which demonstrated that Ce6 loaded in GEV could be efficiently delivered into tumor cells. When Ce6@GEV and 18F-FDG co-existed incubated with 4T1 cells, the cell viability plummeted from more than 88.02 ± 1.30% to 23.79 ± 1.59%, indicating excellent CL-induced PDT effects. In vivo fluorescence images showed a peak tumor/liver ratio of 1.36 ± 0.09 at 24 h after Ce6@GEV injection. For in vivo antitumor therapy, Ce6@GEV + 18F-FDG group had the best tumor inhibition rate (58.02%) compared with the other groups, with the longest survival rate (35 days, 40%). During the whole treatment process, neither blood biochemical analysis nor histological observation revealed vital organ damage, suggesting the biosafety of this treatment strategy. CONCLUSIONS: The simultaneous accumulation of 18F-FDG and Ce6 in tumor tissues is expected to overcome the deficiency of traditional PDT. This strategy has the potential to extend PDT to a variety of tumors, including metastases, using targeted radiotracers to provide internal excitation of light-responsive therapeutics. We expect that our method will play a critical role in precision treatment of deep solid tumors.


Assuntos
Vesículas Extracelulares , Nanopartículas , Fotoquimioterapia , Camundongos , Animais , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/uso terapêutico , Fotoquimioterapia/métodos , Linhagem Celular Tumoral , Leite , Fluordesoxiglucose F18 , Luminescência , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Cabras
4.
Eur J Nucl Med Mol Imaging ; 48(9): 2737-2748, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33537836

RESUMO

PURPOSE: We dual-labeled an intercellular adhesion molecule-1 (ICAM-1) monoclonal antibody (mAb) and evaluated its effectiveness for lesion detection and surgical navigation in pancreatic ductal adenocarcinoma (PDAC) via multiple noninvasive imaging approaches, including positron emission tomography (PET), near-infrared fluorescence (NIRF), and Cerenkov luminescence imaging (CLI). METHODS: ICAM-1 expression in PDAC cell lines (BxPC-3 and AsPC-1) was assessed via flow cytometry and immunofluorescent staining. An ICAM-1 mAb labeled by IRDye 800CW and radionuclide zirconium-89 (denoted as [89Zr]Zr-DFO-ICAM-1-IR800) was synthesized. Its performance was validated via in vivo comparative PET/NIRF/CLI and biodistribution (Bio-D) studies in nude mice bearing subcutaneous BxPC-3/AsPC-1 tumors or orthotopic BxPC-3 tumor models using nonspecific IgG as an isotype control tracer. RESULTS: ICAM-1 expression was strong in the BxPC-3 and minimal in the AsPC-1 cell line. Both multimodality imaging and Bio-D data exhibited more prominent uptake of [89Zr]Zr-DFO-ICAM-1-IR800 in BxPC-3 tumors than in AsPC-1 tumors. The uptake of [89Zr]Zr-DFO-IgG-IR800 in BxPC-3 tumors was similar to that of [89Zr]Zr-DFO-ICAM-1-IR800 in AsPC-1 tumors. These results demonstrate the desirable affinity and specificity of [89Zr]Zr-DFO-ICAM-1-IR800 compared to [89Zr]Zr-DFO-IgG-IR800. Orthotopic BxPC-3 tumor foci could also be clearly delineated by [89Zr]Zr-DFO-ICAM-1-IR800. An intermodal match was achieved in the ICAM-1-targeted immunoPET/NIRF/CLI. The positive expression levels of ICAM-1 in BxPC-3 tumor tissue were further confirmed by immunohistopathology. CONCLUSION: We successfully developed a dual-labeled ICAM-1-targeted tracer for PET/NIRF/CLI of PDAC that can facilitate better diagnosis and intervention of PDAC upon clinical translation.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Animais , Carcinoma Ductal Pancreático/diagnóstico por imagem , Linhagem Celular Tumoral , Molécula 1 de Adesão Intercelular , Camundongos , Camundongos Nus , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Distribuição Tecidual , Zircônio
5.
Mol Pharm ; 18(3): 940-951, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33404254

RESUMO

Almost 17 million Americans have a history of cancer, a number expected to reach over 22 million by 2030. Cancer patients often undergo chemotherapy in the form of antineoplastic agents such as cis-platin and paclitaxel. Though effective, these agents can induce debilitating side effects; the most common neurotoxic effect, chemotherapy-induced peripheral neuropathy (CIPN), can endure long after treatment ends. Despite the widespread and chronic nature of the dysfunction, no tools exist to quantitatively measure chemotherapy-induced peripheral neuropathy. Such a tool would not only benefit patients but their stratification could also save significant financial and social costs associated with neuropathic pain. In our first step toward addressing this unmet clinical need, we explored a novel dual approach to localize peripheral nerves: Cerenkov luminescence imaging (CLI) and fluorescence imaging (FI). Our approach revolves around the targeting and imaging of voltage-gated sodium channel subtype NaV1.7, highly expressed in peripheral nerves from both harvested human and mouse tissues. For the first time, we show that Hsp1a, a radiolabeled NaV1.7-selective peptide isolated from Homoeomma spec. Peru, can serve as a targeted vector for delivering a radioactive sensor to the peripheral nervous system. In situ, we observe high signal-to-noise ratios in the sciatic nerves of animals injected with fluorescently labeled Hsp1a and radiolabeled Hsp1a. Moreover, confocal microscopy on fresh nerve tissue shows the same high ratios of fluorescence, corroborating our in vivo results. This study indicates that fluorescently labeled and radiolabeled Hsp1a tracers could be used to identify and demarcate nerves in a clinical setting.


Assuntos
Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Porfirinas/química , Animais , Antineoplásicos/efeitos adversos , Feminino , Fluorescência , Humanos , Camundongos , Camundongos Nus , Doenças do Sistema Nervoso Periférico/induzido quimicamente , Nervo Isquiático/diagnóstico por imagem , Nervo Isquiático/efeitos dos fármacos
6.
J Nanobiotechnology ; 19(1): 212, 2021 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-34271928

RESUMO

Cerenkov luminescence imaging (CLI) is a novel optical imaging technique that has been applied in clinic using various radionuclides and radiopharmaceuticals. However, clinical application of CLI has been limited by weak optical signal and restricted tissue penetration depth. Various fluorescent probes have been combined with radiopharmaceuticals for improved imaging performances. However, as most of these probes only interact with Cerenkov luminescence (CL), the low photon fluence of CL greatly restricted it's interaction with fluorescent probes for in vivo imaging. Therefore, it is important to develop probes that can effectively convert energy beyond CL such as ß and γ to the low energy optical signals. In this study, a Eu3+ doped gadolinium oxide (Gd2O3:Eu) was synthesized and combined with radiopharmaceuticals to achieve a red-shifted optical spectrum with less tissue scattering and enhanced optical signal intensity in this study. The interaction between Gd2O3:Eu and radiopharmaceutical were investigated using 18F-fluorodeoxyglucose (18F-FDG). The ex vivo optical signal intensity of the mixture of Gd2O3:Eu and 18F-FDG reached 369 times as high as that of CLI using 18F-FDG alone. To achieve improved biocompatibility, the Gd2O3:Eu nanoparticles were then modified with polyvinyl alcohol (PVA), and the resulted nanoprobe PVA modified Gd2O3:Eu (Gd2O3:Eu@PVA) was applied in intraoperative tumor imaging. Compared with 18F-FDG alone, intraoperative administration of Gd2O3:Eu@PVA and 18F-FDG combination achieved a much higher tumor-to-normal tissue ratio (TNR, 10.24 ± 2.24 vs. 1.87 ± 0.73, P = 0.0030). The use of Gd2O3:Eu@PVA and 18F-FDG also assisted intraoperative detection of tumors that were omitted by preoperative positron emission tomography (PET) imaging. Further experiment of image-guided surgery demonstrated feasibility of image-guided tumor resection using Gd2O3:Eu@PVA and 18F-FDG. In summary, Gd2O3:Eu can achieve significantly optimized imaging property when combined with 18F-FDG in intraoperative tumor imaging and image-guided tumor resection surgery. It is expected that the development of the Gd2O3:Eu nanoparticle will promote investigation and application of novel nanoparticles that can interact with radiopharmaceuticals for improved imaging properties. This work highlighted the impact of the nanoprobe that can be excited by radiopharmaceuticals emitting CL, ß, and γ radiation for precisely imaging of tumor and intraoperatively guide tumor resection.


Assuntos
Gadolínio/química , Nanopartículas/química , Imagem Óptica/métodos , Compostos Radiofarmacêuticos/química , Cirurgia Assistida por Computador/métodos , Animais , Feminino , Fluordesoxiglucose F18 , Gadolínio/farmacologia , Luminescência , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Imagem Molecular/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacologia
7.
Nanomedicine ; 17: 62-70, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30654183

RESUMO

Detecting deep tumors inside living subject is still challenging for Cerenkov luminescence imaging (CLI). In this study, a high-sensitivity endoscopic CLI (ECLI) system was developed with a dual-mode deep cooling approach to improve the imaging sensitivity. System was characterized through a series of ex vivo studies. Furthermore, subcutaneous and orthotropic human hepatocellular carcinoma (HCC) mouse models were established for ECLI guided tumor resection in vivo. The results showed that the ECLI system had spatial resolution (62.5 µm) and imaging sensitivity (6.29 × 10-2 kBq/µl 18F-FDG). The in vivo experimental data from the HCC mouse models demonstrated that the system was effective to intraoperatively guide the surgery of deep tumors such as liver cancer. Overall, the developed system exhibits promising potential for the applications of tumor precise resection and novel nanoprobe based optical imaging.


Assuntos
Carcinoma Hepatocelular/cirurgia , Endoscopia/instrumentação , Neoplasias Hepáticas/cirurgia , Medições Luminescentes/instrumentação , Cirurgia Assistida por Computador/instrumentação , Animais , Carcinoma Hepatocelular/diagnóstico por imagem , Linhagem Celular Tumoral , Modelos Animais de Doenças , Desenho de Equipamento , Feminino , Fluordesoxiglucose F18/análise , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Camundongos , Camundongos Nus , Imagem Óptica/instrumentação
8.
Mol Imaging ; 17: 1536012118788637, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30043654

RESUMO

Cerenkov luminescence imaging (CLI) is commonly performed using two-dimensional (2-D) conventional optical imaging systems for its cost-effective solution. However, quantification of CLI comparable to conventional three-dimensional positron emission tomography (PET) is challenging using these systems due to both the high attenuation of Cerenkov radiation (CR) on mouse tissue and nonexisting depth resolution of CLI using 2-D imaging systems (2-D CLI). In this study, we developed a model that estimates effective tissue attenuation coefficient and corrects the tissue attenuation of CLI signal intensity independent of tissue depth and size. To evaluate this model, we used several thin slices of ham as a phantom and placed a radionuclide (89Zr and 64Cu) inside the phantom at different tissue depths and sizes (2, 7, and 12 mm). We performed 2-D CLI and MicroPET/CT (Combined small animal PET and Computed Tomography (CT)) imaging of the phantom and in vivo mouse model after administration of 89Zr tracer. Estimates of the effective tissue attenuation coefficient (µeff) for 89Zr and 64Cu were ∼2.4 and ∼2.6 cm-1, respectively. The computed unit conversion factor to %ID/g from 2-D CLI signal was 2.74 × 10-3 µCi/radiance estimated from phantom study. After applying tissue attenuation correction and unit conversion to the in vivo animal study, an average quantification difference of 10% for spleen and 35% for liver was obtained compared to PET measurements. The proposed model provides comparable quantification accuracy to standard PET system independent of deep tissue CLI signal attenuation.


Assuntos
Luminescência , Medições Luminescentes/métodos , Tomografia por Emissão de Pósitrons/métodos , Animais , Fígado/diagnóstico por imagem , Camundongos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Baço/diagnóstico por imagem
9.
Nanomedicine ; 14(1): 205-213, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29045825

RESUMO

Apoptosis imaging enables a timely and specific assessment of treatment response in cancer patients. In this study, we applied a probe for positron emission tomography (PET), which served as an optical biomaterial emitting Cerenkov photons, to in vivo optical imaging of tumor apoptosis, in order to evaluate early response to chemotherapy of drug-resistant gastric cancer. 68Ga-DOTA-Annexin V was prepared as the apoptosis targeting probe. Wild type human gastric adenocarcinoma cell line SGC7901/WT and drug vincristine-resistant variant SGC7901/VCR were used to establish normal and vincristine-resistant xenografts to simulate treatment decision situation. Vincristine-resistance of SGC7901/VCR and apoptosis-induction ability of vincristine and cisplatin were verified. In vitro and in vivo CLI of apoptosis was performed. Stronger signals of apoptosis of CLI correlated with confirmed higher levels of apoptosis and subsequent changes in tumor sizes. Our study suggests that CLI is a promising technique for in vivo imaging of apoptosis with radiopharmaceutical-labeled biomaterials.


Assuntos
Apoptose/efeitos dos fármacos , Cisplatino/farmacologia , Resistência a Múltiplos Medicamentos , Resistencia a Medicamentos Antineoplásicos , Neoplasias Gástricas/patologia , Vincristina/farmacologia , Animais , Antineoplásicos/farmacologia , Antineoplásicos Fitogênicos/farmacologia , Feminino , Radioisótopos de Gálio/metabolismo , Humanos , Luminescência , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/metabolismo , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/tratamento farmacológico , Neoplasias Gástricas/metabolismo , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto
10.
Nanomedicine ; 13(4): 1323-1331, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28115248

RESUMO

Fluorescent molecular imaging technique has been actively explored for optical image-guided cancer surgery in pre-clinical and clinical research and has attracted many attentions. However, the efficacy of the fluorescent image-guided cancer surgery can be compromised by the low signal-to-noise ratio caused by the external light excitation. This study presents a novel nanoparticle-mediated radiopharmaceutical-excited fluorescent (REF) image-guided cancer surgery strategy, which employs the internal dual-excitation of europium oxide nanoparticles through both gamma rays and Cerenkov luminescence emitted from radiopharmaceuticals. The performance of the novel image-guided surgery technique was systematically evaluated using subcutaneous breast cancer 4 T1 tumor models, orthotropic and orthotropic-ectopic hepatocellular carcinoma tumor-bearing mice. The results reveal that the novel REF image-guided cancer surgery technique exhibits high performance of detecting invisible ultra-small size tumor (even less than 1 mm) and residual tumor tissue. Our study demonstrates the high potential of the novel image-guided cancer surgery for precise tumor resection.


Assuntos
Neoplasias da Mama/cirurgia , Neoplasias Hepáticas/cirurgia , Imagem Molecular , Nanopartículas/química , Compostos Radiofarmacêuticos/química , Cirurgia Assistida por Computador , Animais , Linhagem Celular Tumoral , Fluorescência , Humanos , Camundongos , Transplante de Neoplasias
11.
Small ; 12(35): 4894-4901, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27439987

RESUMO

New imaging probes with high sensitivity and stability are urgently needed to accurately detect sentinel lymph nodes (SLNs) for successful cancer diagnosis. Herein, the use of highly sensitive and stable PEGylated radionuclide-embedded gold nanoparticles (PEG-RIe-AuNPs) is reported for the detection of SLNs by combined positron emission tomography and Cerenkov luminescence imaging (PET/CLI). PEG-RIe-AuNPs show high sensitivity and stability both in vitro and in vivo, and are not toxic to normal ovarian and immune cells. In vivo PET/CLI imaging clearly reveals SLNs as early as 1 h post PEG-RIe-AuNP-injection, with peak signals achieved at 6 h postinjection, which is consistent with the biodistribution results. Taken together, the data provide strong evidence that PEG-RIe-AuNPs are promising as potential lymphatic tracers in biomedical imaging for pre and intraoperative surgical guidance.


Assuntos
Ouro/química , Luminescência , Nanopartículas Metálicas/química , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/química , Linfonodo Sentinela/diagnóstico por imagem , Animais , Morte Celular/efeitos dos fármacos , Linhagem Celular , Injeções Intravenosas , Nanopartículas Metálicas/toxicidade , Nanopartículas Metálicas/ultraestrutura , Camundongos Endogâmicos C57BL , Polietilenoglicóis/síntese química , Polietilenoglicóis/química , Linfonodo Sentinela/patologia
12.
J Fluor Chem ; 178: 136-141, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26504251

RESUMO

We present the synthesis and characterization of F18-labeled fluorinated derivatives of resazurin, a probe for cell viability. The compounds were prepared by direct fluorination of resazurin with diluted [F18]-F2 gas under acidic conditions. The fluorination occurs into the ortho-positions to the hydroxyl group producing various mono-, di-, and trifluorinated derivatives. The properties of the fluorinated resazurins are similar to the parent compound with the addition of fluorine leading to decreased pKa values and a bathochromic shift of the absorption maxima. The fluorinated resazurin derivatives can be used as probes for observation of cell viability in various cells, tissues and organs using a combination of positron emission tomography and direct optical imaging of Cerenkov luminescence.

13.
Small ; 10(18): 3729-34, 2014 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-24861843

RESUMO

Cerenkov luminescence (CL) imaging is an emerging technique that collects the visible photons produced by radioisotopes. Here, molecular imaging strategies are investigated that switch the CL signal off. The noninvasive molecularly specific detection of cancer is demonstrated utilizing a combination of clinically approved agents, and their analogues. CL is modulated in vitro in a dose dependent manner using approved small molecules (Lymphazurin), as well as the clinically approved Feraheme and other preclinical superparamagnetic iron oxide nanoparticles (SPIO). To evaluate the quenching of CL in vivo, two strategies are pursued. [(18) F]-FDG is imaged by PET and CL in tumors prior to and following accumulation of nanoparticles. Initially, non-targeted particles are administered to mice bearing tumors in order to attenuate CL. For targeted imaging, a dual tumor model (expressing the human somatostatin receptor subtype-2 (hSSTr2) and a control negative cell line) is used. Targeting hSSTr2 with octreotate-conjugated SPIO, quenched CL enabling non-invasive distinction between tumors' molecular expression profiles is demonstrated. In this work, the quenching of Cerenkov emissions is demonstrated in several proof of principle models using a combination of approved agents and nanoparticle platforms to provide disease relevant information including tumor vascularity and specific antigen expression.


Assuntos
Nanopartículas Metálicas/química , Imagem Molecular/métodos , Animais , Corantes/química , Compostos Férricos/química , Humanos , Luminescência , Camundongos , Nanotecnologia/métodos , Transplante de Neoplasias , Receptores de Somatostatina/química , Corantes de Rosanilina/química , Espectrofotometria
14.
J Labelled Comp Radiopharm ; 57(9): 558-65, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25042833

RESUMO

Cerenkov luminescence imaging (CLI) is an emerging preclinical molecular imaging modality that tracks the radiation emitted in the visible spectrum by fast moving charged decay products of radionuclides. The aim of this study was in vitro and in vivo evaluation of the two radiotracers, (90) Y-DOTA-PEG28 -A20FMDV2 ((90) Y-1) and (90) Y-DOTA-Ahx-A20FMDV2 ((90) Y-2) (>99% radiochemical purity, 3.7 GBq/µmol specific activity) for noninvasive assessment of tumors expressing the integrin αv ß6 and their future use in tumor targeted radiotherapy. Cell binding and internalization in αv ß6 -positive cells was (90) Y-1: 10.1 ± 0.8%, 50.3 ± 2.1%; (90) Y-2: 22.4 ± 1.7%, 44.7 ± 1.5% with <5% binding to αv ß6 -negative control cells. Biodistribution studies showed maximum αv ß6 -positive tumor uptake of the radiotracers at 1-h post injection (p.i.) ((90) Y-1: 0.64 ± 0.15% ID/g; (90) Y-2: 0.34 ± 0.11% ID/g) with high renal uptake (>25% ID/g at 24 h). Because of the lower tumor uptake and high radioactivity accumulation in kidneys (that could not be reduced by pre-administration of either lysine or furosemide), the luminescence signal from the αv ß6 -positive tumor was not clearly detectable in CLI images. The studies suggest that CLI is useful for indicating major organ uptake for both radiotracers; however, it reaches its limitation when there is low signal-to-noise ratio.


Assuntos
Antígenos de Neoplasias/metabolismo , Integrinas/metabolismo , Luminescência , Neoplasias/diagnóstico por imagem , Fragmentos de Peptídeos/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Radioisótopos de Ítrio/farmacocinética , Animais , Integrinas/antagonistas & inibidores , Masculino , Camundongos , Neoplasias/metabolismo , Fragmentos de Peptídeos/síntese química , Ligação Proteica , Radiografia , Compostos Radiofarmacêuticos/síntese química , Distribuição Tecidual , Proteínas do Envelope Viral/síntese química , Proteínas do Envelope Viral/fisiologia , Radioisótopos de Ítrio/química
15.
J Nucl Med ; 64(4): 598-604, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36357181

RESUMO

Intraoperative identification of positive resection margins (PRMs) in high-risk prostate cancer (PC) needs improvement. Cerenkov luminescence imaging (CLI) with 68Ga-PSMA-11 is promising, although limited by low residual activity and artificial signals. Here, we aimed to assess the value of CLI and flexible autoradiography (FAR) with 18F-PSMA-1007. Methods: Mice bearing subcutaneous PSMA-avid RM1-PGLS tumors were administered 18F-PSMA-1007, and PET/CT was performed. After the animals had been killed, organs were excised and measured signals in CLI and FAR CLI were correlated with tracer activity concentrations (ACs) obtained from PET/CT. For clinical assessment, 7 high-risk PC patients underwent radical prostatectomy immediately after preoperative 18F-PSMA PET/CT. Contrast-to-noise ratios (CNRs) were calculated for both imaging modalities in intact specimens and after incision above the index lesion. Results: In the heterotopic in vivo mouse model (n = 5), CLI did not detect any lesion. FAR CLI detected a distinct signal in all mice, with a lowest AC of 7.25 kBq/mL (CNR, 5.48). After incision above the index lesion of the prostate specimen, no increased signal was observed at the cancer area in CLI. In contrast, using FAR CLI, a signal was detectable in 6 of 7 patients. The AC in the missed index lesion was 1.85 kBq/mL, resulting in a detection limit of at least 2.06 kBq/mL. Histopathology demonstrated 2 PRMs, neither of which was predicted by CLI or FAR CLI. Conclusion: 18F-PSMA FAR CLI was superior to CLI in tracer-related signal detectability. PC was could be visualized in radical prostatectomy down to 2.06 kBq/mL. However, the detection of PRMs was limited. Direct anatomic correlation of FAR CLI is challenging because of the scintillator overlay.


Assuntos
Próstata , Neoplasias da Próstata , Humanos , Masculino , Animais , Camundongos , Próstata/diagnóstico por imagem , Próstata/cirurgia , Próstata/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Autorradiografia , Luminescência , Estudos de Viabilidade , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Radioisótopos de Gálio , Prostatectomia/métodos
16.
ACS Nano ; 17(21): 20776-20803, 2023 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-37874930

RESUMO

External light sources, such as lasers, light emitting diodes (LEDs) and lamps, are widely applied in photodynamic therapy (PDT); however, their use is severely limited by the nature of shallow tissue penetration depth. The recent exploration of light delivery or local generation on tumor sites has attracted much attention, owing to the fact that these systems are significantly endowed with high tissue penetration. In this review, we briefly introduced the principle of "on-spot light generation or delivery systems" in PDT. These systems are divided into different categories: (1) implantable luminescence, (2) mechanoluminescence, (3) electrochemiluminescence, (4) Cerenkov luminescence, (5) chemiluminescence, and (6) bioluminescence. Finally, their applications, advantages, and disadvantages in PDT will be appropriately summarized and further discussed in detail. We believe that this review will provide general guidance for the further design of light generation or delivery systems and clinical studies for PDT-mediated cancer treatments with unparalleled merits.


Assuntos
Fotoquimioterapia , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/uso terapêutico
17.
J Biophotonics ; 15(11): e202200126, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36328059

RESUMO

Cerenkov luminescence tomography (CLT) is a promising three-dimensional imaging technology that has been actively investigated in preclinical studies. However, because of the ill-posedness in the inverse problem of CLT reconstruction, the reconstruction performance is still not satisfactory for broad biomedical applications. In this study, a novel weighted auxiliary set matching pursuit (WASMP) method was explored to enhance the accuracy of CLT reconstruction. The numerical simulations and in vivo imaging studies using tumor-bearing mice models were conducted to evaluate the performance of the WASMP method. The results of the above experiments proved that the WASMP method achieved superior reconstruction performance than other approaches in terms of positional accuracy and shape recovery. It further demonstrates that the atom selection strategy proposed in this study has a positive effect on improving the accuracy of atoms. The proposed WASMP improves the accuracy for CLT reconstruction for biomedical applications.


Assuntos
Glioma , Tomografia Óptica , Animais , Camundongos , Tomografia Óptica/métodos , Luminescência , Tomografia , Tomografia Computadorizada por Raios X , Imageamento Tridimensional/métodos , Glioma/diagnóstico por imagem , Algoritmos , Imagens de Fantasmas
18.
Theranostics ; 12(14): 6380-6394, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36168637

RESUMO

Rationale: [18F]fluorodeoxyglucose-positron emission tomography ([18F]FDG-PET) has been widely used as an imaging technique to measure interscapular brown adipose tissue (iBAT) activity. However, it is challenging to obtain iBAT-specific images using [18F]FDG-PET because increased uptake of [18F]FDG is observed in tumors, muscle, and inflamed tissues. Uncoupling protein 1 (UCP1) in the mitochondrial membrane, a well-known molecular marker of BAT, has been proposed as a useful BAT imaging marker. Recently, the UCP1 ThermoMouse was developed as a reporter mouse for monitoring UCP1 expression and investigating BAT activation. In addition, Translocator protein-18 kDa (TSPO) located in the outer mitochondrial membrane is also overexpressed in BAT, suggesting that TSPO-targeting PET has potential for iBAT imaging. However, there are no studies monitoring BAT using TSPO-targeting PET probes in the UCP1 ThermoMouse. Moreover, the non-invasive Cerenkov luminescence imaging (CLI) using Cerenkov radiation from the PET probe has been proposed as an alternative option for PET as it is less expensive and user-friendly. Therefore, we selected [18F]fm-PBR28-d 2 as a TSPO-targeting PET probe for iBAT imaging to evaluate the usefulness of CLI in the UCP1 ThermoMouse. Methods: UCP1 ThermoMouse was used to monitor UCP1 expression. Western blotting and immunohistochemistry were performed to measure the level of protein expression. [18F]fm-PBR28-d 2 and [18F]FDG were used as radioactive probes for iBAT imaging. PET images were acquired with SimPET, and optical images were acquired with IVIS 100. Results: UCP1 ThermoMouse showed that UCP1 and TSPO expressions were correlated in iBAT. In both PET and CLI, the TSPO-targeting probe [18F]fm-PBR28-d 2 was superior to [18F]FDG for acquiring iBAT images. The high molar activity of the probe was essential for CLI and PET imaging. We tested the feasibility of TSPO-targeting probe under cold exposure by imaging with TSPO-PET/CLI. Both signals of iBAT were clearly increased after cold stimulation. Under prolonged isoflurane anesthesia, TSPO-targeting images showed higher signals from iBAT in the short-term than in long-term groups. Conclusion: We demonstrated that TSPO-PET/CLI reflected UCP1 expression in iBAT imaging better than [18F]FDG-PET/CLI under the various conditions. Considering convenience and cost, TSPO-CLI could be used as an alternative TSPO-PET technique for iBAT imaging.


Assuntos
Fluordesoxiglucose F18 , Isoflurano , Tecido Adiposo Marrom/diagnóstico por imagem , Tecido Adiposo Marrom/metabolismo , Animais , Fluordesoxiglucose F18/metabolismo , Isoflurano/metabolismo , Luminescência , Camundongos , Tomografia por Emissão de Pósitrons/métodos , Proteína Desacopladora 1/metabolismo
19.
J Nucl Med ; 63(9): 1349-1356, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34916249

RESUMO

Cerenkov luminescence imaging (CLI) was successfully implemented in the intraoperative context as a form of radioguided cancer surgery, showing promise in the detection of surgical margins during robot-assisted radical prostatectomy. The present study was designed to provide a quantitative description of the occupational radiation exposure of surgery and histopathology personnel from CLI-guided robot-assisted radical prostatectomy after the injection of 68Ga-PSMA-11 in a single-injection PET/CT CLI protocol. Methods: Ten patients with preoperative 68Ga-PSMA-11 administration and intraoperative CLI were included. Patient dose rate was measured before PET/CT (n = 10) and after PET/CT (n = 5) at a 1-m distance for 4 patient regions (head [A], right side [B], left side [C], and feet [D]). Electronic personal dosimetry (EPD) was used for intraoperative occupational exposure (n = 10). Measurements included the first surgical assistant and scrub nurse at the operating table and the CLI imager/surgeon at the robotic console and encompassed the whole duration of surgery and CLI image acquisition. An estimation of the exposure of histopathology personnel was performed by measuring prostate specimens (n = 8) with a germanium detector. Results: The measured dose rate value before PET/CT was 5.3 ± 0.9 (average ± SD) µSv/h. This value corresponds to a patient-specific dose rate constant for positions B and C of 0.047 µSv/h⋅MBq. The average dose rate value after PET/CT was 1.04 ± 1.00 µSv/h. The patient-specific dose rate constant values corresponding to regions A to D were 0.011, 0.026, 0.024, and 0.003 µSv/h⋅MBq, respectively. EPD readings revealed average personal equivalent doses of 9.0 ± 7.1, 3.3 ± 3.9, and 0.7 ± 0.7 µSv for the first surgical assistant, scrub nurse, and CLI imager/surgeon, respectively. The median germanium detector-measured activity of the prostate specimen was 2.96 kBq (interquartile range, 2.23-7.65 kBq). Conclusion: Single-injection 68Ga-PSMA-11 PET/CT CLI procedures are associated with a reasonable occupational exposure level, if kept under 110 procedures per year. Excised prostate specimen radionuclide content was below the exemption level for 68Ga. Dose rate-based calculations provide a robust estimation for EPD measurements.


Assuntos
Germânio , Exposição Ocupacional , Neoplasias da Próstata , Proteção Radiológica , Robótica , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Luminescência , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prostatectomia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Radioisótopos
20.
EJNMMI Res ; 12(1): 70, 2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36307610

RESUMO

BACKGROUND: Programmed cell death 1 ligand 1(PD-L1) is overexpressed in many tumors. The radionuclide-labeled anti-PD-L1 monoclonal antibody can be used for imaging and therapy of PD-L1 overexpressing cancer. Here, we described 131I-labeled Atezolizumab (131I-Atezolizumab, targeting PD-L1) as a therapeutic agent for colorectal cancer with PD-L1 overexpression. METHODS: 131I-Atezolizumab was prepared by the Iodogen method. The expression levels of PD-L1 in different human colorectal cells were determined by flow cytometry, western blot and cell binding assay. The immunoreactivity of 131I-Atezolizumab to PD-L1 high-expressing cells was determined by immunoreactive fraction. The killing abilities of different concentrations of 131I-Atezolizumab on cells with high and low expression of PD-L1 were detected by the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) method. Cerenkov luminescence imaging (CLI) and radioimmunotherapy (RIT) of 131I-Atezolizumab were performed on two human colorectal cancer models. The distribution and tumor targeting of 131I-Atezolizumab were evaluated by imaging. Tumor volume and survival time were used as indicators to evaluate the anti-tumor effect of 131I-Atezolizumab. RESULTS: The expression level of PD-L1 in vitro determined by the cell binding assay was related to the data of flow cytometry and western blot. 131I-Atezolizumab can specifically bind to PD-L1 high-expressing cells in vitro to reflect the expression level of PD-L1. Immunoreactive fraction of PD-L1 high-expressing RKO cells with 131I-Atezolizumab was 52.2%. The killing ability of 131I-Atezolizumab on PD-L1 high-expressing cells was higher than that of low-expressing cells. CLI proved that the specific uptake level of tumors depends on the expression level of PD-L1. Effect of 131I-Atezolizumab RIT showed an activity-dependent tumor suppressor effect on RKO tumor-bearing mice with high PD-L1 expression. 131I-Atezolizumab (37 MBq) can improve the median survival time of mice (34 days), compared to untreated mice (27 days) (P = 0.027). Although a single activity(37 MBq) of 131I-Atezolizumab also inhibited the tumors of HCT8 tumor-bearing mice with low PD-L1 expression (P < 0.05), it could not prolong the survival of mice(P = 0.29). CONCLUSION: 131I-Atezolizumab can be used as a CLI agent for screening PD-L1 expression levels. It may be used as a radioimmunotherapy drug target for PD- L1 overexpressing tumors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA