RESUMO
BACKGROUND: Patients arriving at the emergency department with a potential cervical spine injury and immobilized in a rigid cervical collar often require emergency airway management and rapid sequence induction intubation (RSII). There have been several advances in airway management with the advent of channeled (Airtraqâ; Prodol Meditec) and nonchanneled (McGrathâ; Meditronics) video laryngoscopes, which enable intubation without the removal of the cervical collar, but their efficacy and superiority over conventional laryngoscopy (Macintosh) in the presence of a rigid cervical collar and cricoid pressure have not been evaluated. OBJECTIVE: Our aim was to compare the channeled (Airtraq [group A]) and nonchanneled (McGrath [Group M]) video laryngoscopes with a conventional laryngoscope (Macintosh [Group C]) in a simulated trauma airway. METHODS: A prospective randomized controlled study was conducted in a tertiary care center. Participants were 300 patients requiring general anesthesia (American Society of Anesthesiologists class I or II), of both sexes, and aged 18-60 years. Airway management was simulated without removal of a rigid cervical collar and using cricoid pressure during intubation. After RSI, patients were intubated with one of the study techniques according to randomization. Intubation time and intubation difficulty scale (IDS) score were noted. RESULTS: Mean intubation time was 42.2 s in group C, 35.7 s in group M, and 21.8 s in group A (p = 0.001). Intubation was easy in group M and group A (median IDS score of 0; interquartile range [IQR] 0-1 for group M and median IDS score of 1; IQR 0-2 for group A and group C; p < 0.001). A higher proportion (95.1%) of patients had an IDS score of < 1 in group A. CONCLUSIONS: The performance of RSII with cricoid pressure in the presence of a cervical collar was easier and more rapid with channeled video laryngoscope than with other techniques.
Assuntos
Laringoscópios , Masculino , Feminino , Humanos , Indução e Intubação de Sequência Rápida , Intubação Intratraqueal/métodos , Estudos Prospectivos , Laringoscopia/métodos , Gravação em VídeoRESUMO
We compared the hyperangulated McGrath X-blade with the Macintosh-type CMAC videolaryngoscope through the use of manual in-line stabilization on patients. The primary hypothesis was that the McGrath X-blade has a similar first-attempt success rate as the CMAC videolaryngoscope. 210 patients of ASA physical status I to III, aged 21 to 80 years old, undergoing general anesthesia requiring tracheal intubation were prospectively recruited into this two-centre randomized controlled trial, from June 2016 to April 2019. Patients with history of or predicted difficult airway, pre-existing dental risks, BMI > 35 kg/m2, cervical spondylosis or myelopathy, aspiration risks, patients who declined to participate or lacked the mental capacity to give consent were excluded. Participants were intubated using either hyperangulated McGrath X-blade (MGX) or Macintosh-type CMAC (CM) videolaryngoscopy, with manual in-line stabilization. Primary outcome measured was first-attempt tracheal intubation success. Secondary outcomes included overall successful intubation within 2 attempts or 120 s, time to intubation, glottic view obtained and intubation-related complications. First-attempt success rates were 71.4% in the MGX group vs. 79.0% in the CM group (p = 0.26), with an absolute difference of -7.6% (95%CI -20%, 5.0%, p value = 0.26), but this trial was underpowered to detect a difference. Overall success was 91.4% (MGX) vs. 92.4% (CM) (p > 0.99). The Cormack & Lehane laryngeal grade was superior in the MGX group compared to CM group (Grade I: MGX 44%, CM 23%; Grade II: MGX 53%, CM 45%; Grade III: MGX 3%, CM 32%; p < 0.001). The median time to intubation using the MGX was longer than the CM [MGX 55.5 s (42.1-78.3), CM 43.8 s (38-55.3); p < 0.001]. Our study did not demonstrate a significant difference in efficacy between the McGrath X-blade and the CMAC videolaryngoscope. In patients with manual in-line stabilization, no anticipated airway difficulty and in the hands of experienced operators, the McGrath X-blade provided superior glottic views but conferred no advantage over the C-MAC, with a longer median time to intubation compared to the CMAC videolaryngoscope.Trial registration: Australian New Zealand Clinical Trial Registry (ACTRN12616000668404).
Assuntos
Laringoscópios , Laringoscopia , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália , Glote , Humanos , Intubação Intratraqueal , Pessoa de Meia-Idade , Gravação em Vídeo , Adulto JovemRESUMO
BACKGROUND: Maintaining cervical immobilization is essential during tracheal intubation in patients with unstable cervical spines. When using the Macintosh laryngoscope for intubation in patients with cervical immobilization, substantial neck extension is required for visualization of the glottis. However, the C-MAC D-Blade videolaryngoscope may require less neck extension due to its acute angulation. We hypothesized that C-MAC D-Blade videolaryngoscopic intubation would result in less cervical spine movement than Macintosh laryngoscopic intubation. We compared the effects of C-MAC D-Blade videolaryngoscopic intubation and Macintosh laryngoscopic intubation in terms of cervical spine motion during intubation in patients with simulated cervical immobilization. METHODS: In this randomized crossover study, the cervical spine angle was measured at the occiput-C1, C1-C2, and C2-C5 segments before and during tracheal intubation with either a C-MAC D-Blade videolaryngoscope or Macintosh laryngoscope in 20 patients, with application of a neck collar for simulated cervical immobilization. Cervical spine motion was defined as the change in angle measured before and during tracheal intubation. RESULTS: The cervical spine motion at the occiput-C1 segment was measured at 12.1 ± 4.2° and 6.8 ± 5.0° during Macintosh laryngoscopic and C-MAC D-blade videolaryngoscopic intubation, respectively, corresponding to a 44% reduction in cervical spine motion when using the latter device (mean difference, - 5.3; 98.33% CI: - 8.8 to - 1.8; p = 0.001). However, there was no significant difference between the two intubation devices at the C1-C2 segment (- 0.6; 98.33% CI: - 3.4 to 2.2; p = 0.639) or C2-C5 segment (0.2; 98.33% CI: - 6.0 to 6.4; p = 0.929). CONCLUSIONS: The C-MAC D-Blade videolaryngoscope causes less upper cervical spine motion than the Macintosh laryngoscope during tracheal intubation of patients with simulated cervical immobilization. TRIAL REGISTRATION: This study was registered at ClinicalTrials.gov on June 26, 2018 ( NCT03567902 ).
Assuntos
Vértebras Cervicais/diagnóstico por imagem , Imobilização/métodos , Intubação Intratraqueal/instrumentação , Laringoscópios , Laringoscopia/instrumentação , Cirurgia Vídeoassistida/instrumentação , Idoso , Estudos Cross-Over , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Feminino , Humanos , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Masculino , Pessoa de Meia-Idade , Cirurgia Vídeoassistida/métodosRESUMO
BACKGROUND: The halo vest is widely used throughout the world to manage craniovertebral and cervical instabilities. It can be used for postoperative immobilization or as an alternative to surgical fixation. METHOD: In this paper we present some cases of severe complications from our own practice and review the literature on halo complications. RESULTS: Like any therapeutic manoeuvre, halo placement may be followed by various complications. In the meantime, modern techniques of fixation offer safe and immediate stabilization. CONCLUSION: The halo vest remains a formidable method for cervical immobilization. However, it should not be used a priori instead of surgery.
Assuntos
Braquetes/efeitos adversos , Vértebras Cervicais/cirurgia , Fixadores Externos/efeitos adversos , Instabilidade Articular/cirurgia , Procedimentos Neurocirúrgicos/instrumentação , Humanos , Procedimentos Neurocirúrgicos/efeitos adversos , Restrição Física/efeitos adversos , Restrição Física/instrumentaçãoRESUMO
Emergency airway management in children is generally considered to be challenging, and endotracheal intubation requires a high level of personal skills and experience. Immobilization of the cervical spine is indicated in all patients with the risk of any cervical spine injury but significantly aggravates endotracheal intubation. The best airway device in this setting has not been established yet, although the use of videolaryngoscopes is generally promising. Seventy-five moderately experienced paramedics of the Emergency Medical Service of Poland performed endotracheal intubations in a pediatric manikin in three airway scenarios: (A) normal airway, (B) manual in-line cervical immobilization, and (C) cervical immobilization using a Patriot cervical extrication collar and using two airway techniques: (1) McGrath videolaryngoscope and (2) Macintosh blade in a randomized sequence. First-attempt intubation success rate, time to intubation, glottis visualization, and subjective ease of intubation were investigated in this study. Intubation of difficult airways, including manual in-line and cervical collar immobilization, using the McGrath was significantly faster, with a higher first-attempt intubation success rate, better glottic visualization, and ease of intubation, compared to Macintosh-guided intubation. In the normal airway, both airway techniques performed equal. CONCLUSION: Our manikin study indicates that the McGrath may be a reasonable first intubation technique option for endotracheal intubation in difficult pediatric emergencies. Further clinical studies are therefore indicated. What is known : ⢠Airway management in pediatrics is challenging and requires a high level of skills and experience. Cervical immobilization is indicated in all patients with any risk of cervical spine injury, but it significantly aggravates endotracheal intubation in these patients. Videolaryngoscopes have been reported to ease intubation and provide better airway visualization in the regular clinical setting. What is new: ⢠The McGrath is an easy-to-use and clinically often used videolaryngoscope, but it has never been investigated in pediatrics with an immobilized cervical spine. In the normal airway, the McGrath provided better airway visualization compared to Macintosh laryngoscopy. However, better visualization did not lead to decreased time to intubation and a higher success rate of the first intubation attempt. In difficult airways, the McGrath provided better airway visualization and this led to faster intubation, a higher first-attempt intubation success rate, and better ease of intubation compared to Macintosh-guided intubation.
Assuntos
Tratamento de Emergência/instrumentação , Intubação Intratraqueal/instrumentação , Laringoscópios , Laringoscopia/instrumentação , Restrição Física , Vértebras Cervicais , Criança , Competência Clínica , Estudos Cross-Over , Auxiliares de Emergência , Tratamento de Emergência/métodos , Humanos , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Manequins , Fatores de Tempo , Gravação em VídeoRESUMO
BACKGROUND: Ultrasound has growing applications in airway management during anesthesia. The aim of the present study was to evaluate the feasibility of real-time ultrasound-guided tracheal intubation in patients with cervical spine immobilization relative to fiberscope-guided tracheal intubation. PATIENTS AND METHODS: This randomized controlled study was carried out on 266 adult patients who have a rigid neck collar in place for cervical spine immobilization and were randomly allocated into two equal groups. All patients were subjected to the same anesthetic protocol. After full neuromuscular blockade, neck collar was removed and tracheal intubation was done in the neutral position. In group A, the trachea was intubated guided by a 5-12-MHz linear ultrasound probe attached to a Sonoscape A5 ultrasound machine. In group B, the trachea was intubated by an endotracheal tube mounted over a fiberscope (Karl Storz, working length 65 cm, distal tip diameter 5.6 mm). Hemodynamic measurements and oxygen saturation were recorded. Tracheal intubation criteria for both groups including duration of the intubation procedure, number of intubation attempts, success rate at each attempt, and the lowest oxygen saturation recorded during tracheal intubation were recorded. RESULTS: Ultrasound and fiberscope achieved comparable time for tracheal intubation (57 ± 12 vs. 55 ± 10 s), respectively. Success rate of tracheal intubation at the first attempt was higher in the fiberscope group than the ultrasound group, with a P value of 0.032. The overall success rate was not significantly different between the two groups. CONCLUSIONS: Ultrasound-guided tracheal intubation showed a lower first attempt success rate in patients with cervical spine immobilization compared to fiberscope-guided tracheal intubation but the overall success rates were comparable. Ultrasound can be an alternative technique for guiding tracheal intubation in patients with cervical spine immobilization. REGISTRY NUMBER: PACTR201602001476292.
Assuntos
Manuseio das Vias Aéreas/métodos , Anestesia/métodos , Intubação Intratraqueal/métodos , Bloqueio Neuromuscular/métodos , Adulto , Anestesiologia , Feminino , Humanos , Imobilização , Masculino , TraqueiaRESUMO
The majority of maxillofacial gunshot wounds are caused by suicide attempts. Young men are affected most often. When the lower one-third of the face is involved, airway patency (1.6% of the cases) and hemorrhage control (1.9% of the cases) are the two most urgent complications to monitor and prevent. Spinal fractures are observed with 10% of maxillary injuries and in 20% of orbital injuries. Actions to treat the facial gunshot victim need to be performed, keeping in mind spine immobilization until radiographic imaging is complete and any required spinal stabilization accomplished. Patients should be transported to a trauma center equipped to deal with maxillofacial and neurosurgery because 40% require emergency surgery. The mortality rate of maxillofacial injuries shortly after arrival at a hospital varies from 2.8% to 11.0%. Complications such as hemiparesis or cranial nerve paralysis occur in 20% of survivors. This case has been reported on a victim of four gunshot injuries. One of the gunshots was to the left mandibular ramus and became lodged in the C4 vertebral bone.
Assuntos
Traumatismos Maxilofaciais/terapia , Traumatismos da Coluna Vertebral/terapia , Ferimentos por Arma de Fogo/terapia , Adulto , Serviços Médicos de Emergência , Humanos , Escala de Gravidade do Ferimento , MasculinoRESUMO
PURPOSE: A previous study reported a shorter time to tracheal intubation by reducing percentage of glottic opening (POGO) view to <50% when intubating a normal adult airway using the GlidescopeTM blade. We evaluate the efficacy of reducing POGO to <50% when intubating patients with rigid cervical immobilization using CMACTM D blade. METHODS: One hundred and four adult patients were randomized to group POGO 100% or POGO <50% . Laryngoscopy was performed by advancing tip of the D blade at vallecula. POGO 100% was achieved by exerting upward force to displace epiglottis until glottic opening from the anterior commissure to inter arytenoid notch. POGO < 50% was acquired by withdrawing the D blade tip dorsally from vallecula. The primary outcome was time to intubation. RESULTS: The median time (IQR) to successful intubation was 29 (25-35) seconds for group POGO < 50% and 34 (28-40) seconds for group with POGO 100% (difference in medians, 5 seconds; 95% confidence interval, 2 to 8, p = 0.003). Complications were minor. CONCLUSION: Using the CMACTM D blade with a reduced POGO in patients with cervical spine immobilization resulted in faster tracheal intubation. TRIAL REGISTRATION: The trial is registered at ClinicalTrial.gov (CT.gov identifier: NCT04833166).
Assuntos
Laringoscópios , Adulto , Humanos , Laringoscopia/métodos , Intubação Intratraqueal/métodos , Glote , Vértebras CervicaisRESUMO
BACKGROUND: The aim of this study was to compare tracheal intubation performance regarding the time to intubation, glottic view, difficulty, and dental click, by novices using McGrath videolaryngoscope (VL), Pentax Airway Scope (AWS) and Macintosh laryngoscope in normal and cervical immobilized manikin models. METHODS: Thirty-five anesthesia nurses without previous intubation experience were recruited. Participants performed endotracheal intubation in a manikin model at two simulated neck positions (normal and fixed neck via cervical immobilization), using three different devices three times each. Performance parameters included intubation time, success rate of intubation, Cormack Lehane laryngoscope grading, dental click, and subjective difficulty score. RESULTS: Intubation time and success rate during first attempt were not significantly different between the 3 groups in normal airway manikin. In the cervical immobilized manikin, the intubation time was shorter (p = 0.012), and the success rate with the first attempt was significantly higher (p < 0.001) when using McGrath VL and Pentax AWS compared with Macintosh laryngoscope. Both VLs showed less difficulty score (p < 0.001) and more Cormack Lehane grade I (p < 0.001) in both scenarios. The incidence of dental clicks was higher with Macintosh laryngoscope compared with McGrath VL in cervical immobilized airway (p < 0.001). CONCLUSIONS: McGrath VL and Pentax AWS did not show clinically significant decrease in intubation time, however, they achieved higher first attempt success rate, easier intubation and better glottis view compared with Macintosh laryngoscope by novices in a cervical immobilized manikin model. McGrath VL may reduce the risk of dental injury compared with Macintosh laryngoscope in cervical immobilized scenario. TRIAL REGISTRATION: ClinicalTrials.gov (NCT03161730), May 22, 2017 https://clinicaltrials.gov/ct2/hom.
Assuntos
Vértebras Cervicais/fisiopatologia , Competência Clínica , Imobilização/métodos , Intubação Intratraqueal/instrumentação , Laringoscopia/métodos , Manequins , Gravação em Vídeo/métodos , Adulto , Vértebras Cervicais/diagnóstico por imagem , Estudos Cross-Over , Feminino , Movimentos da Cabeça , Humanos , Intubação Intratraqueal/métodos , Masculino , Fatores de TempoRESUMO
BACKGROUND: Penetrating neck injury is an important trauma subset but is relatively rare, especially when involving the posterior cervical column. Rupture of the neck restraints, including the interspinous and flavum ligaments, can create serious cervical instability that requires special consideration when managing the airway. However, no detailed information regarding airway management in patients with profound posterior neck muscle laceration and direct cervical ligament disruption by an edged weapon is yet available in the literature. CASE PRESENTATION: A 63-year-old Japanese man attempted to cut off his head using a sickle after drinking a copious amount of alcohol. On admission, his posterior vertebral column was grossly exposed and the lacerated tissues were actively bleeding, resulting in severe hypovolemic shock. We used a rapid-sequence intubation technique with direct laryngoscopy while manual in-line stabilization of his head and neck was maintained by several people. Surgical exploration revealed nuchal, interspinous, and flavum ligament rupture between his fourth and fifth cervical vertebrae, but no injury to the great vessels was present. The major source of bleeding was a site of oozing from his trapezius and splenius muscles. After surgical hemostasis, wound repair, and subsequent intensive care, our patient was discharged home without any neurological sequelae. CONCLUSIONS: Deficits of the neck restraints can cause cervical spine subluxation and dislocation secondary to neck movement. Thus, the key to successful airway management in such a scenario is minimization of neck movement to prevent further neurological impairment. We successfully managed an airway using a conventional but trusted endotracheal intubation strategy in a patient with multiple traumas and a suspected spinal cord injury. This case also illustrates that, even when great vessel injury is absent, severe hypovolemic shock may occur after profound neck muscle laceration, requiring immediate surgical intervention.
Assuntos
Intoxicação Alcoólica/psicologia , Vértebras Cervicais/lesões , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Ligamento Amarelo/lesões , Lesões do Pescoço/cirurgia , Comportamento Autodestrutivo/psicologia , Choque/diagnóstico , Ferimentos Penetrantes/cirurgia , Manuseio das Vias Aéreas/métodos , Vértebras Cervicais/patologia , Humanos , Ligamento Amarelo/diagnóstico por imagem , Ligamento Amarelo/cirurgia , Masculino , Pessoa de Meia-Idade , Lesões do Pescoço/fisiopatologia , Unidade Hospitalar de Psiquiatria , Encaminhamento e Consulta , Ruptura , Choque/etiologia , Choque/terapia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ferimentos Penetrantes/terapiaRESUMO
BACKGROUND: Cervical spine immobilization results in a poor laryngeal view on direct laryngoscopy leading to difficulty in intubation. This randomized prospective study was designed to compare the laryngeal view and ease of intubation with the Macintosh, McCoy, and TruView laryngoscopes in patients with immobilized cervical spine. MATERIALS AND METHODS: 60 adult patients of ASA grade I-II with immobilized cervical spine undergoing elective cervical spine surgery were enrolled. Anesthesia was induced with propofol, fentanyl, and vecuronium and maintained with isoflurane and nitrous oxide in oxygen. The patients were randomly allocated into three groups to achieve tracheal intubation with Macintosh, McCoy, or TruView laryngoscopes. When the best possible view of the glottis was obtained, the Cormack-Lehane laryngoscopy grade and the percentage of glottic opening (POGO) score were assessed. Other measurements included the intubation time, the intubation difficulty score, and the intubation success rate. Hemodynamic parameters and any airway complications were also recorded. RESULTS: TruView reduced the intubation difficulty score, improved the Cormack and Lehane glottic view, and the POGO score compared with the McCoy and Macintosh laryngoscopes. The first attempt intubation success rate was also high in the TruView laryngoscope group. However, there were no differences in the time required for successful intubation and the overall success rates between the devices tested. No dental injury or hypoxia occurred with either device. CONCLUSION: The use of a TruView laryngoscope resulted in better glottis visualization, easier tracheal intubation, and higher first attempt success rate as compared to Macintosh and McCoy laryngoscopes in immobilized cervical spine patients.