Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Angew Chem Int Ed Engl ; 59(20): 7772-7777, 2020 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-32045506

RESUMO

Adenosine radicals tagged with a fixed-charge group were generated in the gas phase and structurally characterized by tandem mass spectrometry, deuterium labeling, and UV/Vis action spectroscopy. Experimental results in combination with Born-Oppenheimer molecular dynamics, ab initio, and excited-state calculations led to unambiguous assignment of adenosine radicals as N-7 hydrogen atom adducts. The charge-tagged radicals were found to be electronically equivalent to natural DNA nucleoside radicals.

2.
Anal Bioanal Chem ; 407(25): 7765-74, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26374566

RESUMO

Aldosterone is a mineralocorticoid steroid hormone, the measurement of which in the clinical laboratory is principally performed for the investigation of primary hyperaldosteronism. Primary hyperaldosteronism is a specifically treatable and potentially curable form of hypertension, which typically presents as drug-resistant hypertension and, in up to 37% of cases, hypokalemia. Accurate measurement of aldosterone concentration is essential for correct diagnosis. The serum concentrations of aldosterone are in the picomolar range and therefore sensitive aldosterone assays are required. With the advancement in instrumentation of LC-MS/MS, the picomolar range of aldosterone can be easily measured by the newer models, but for those with a less sensitive instrument, special technique for sample preparation to enhance assay sensitivity is required. This work described the use of charge-tagging for the picomolar measurement of serum aldosterone in a less sensitive LC-MS/MS instrument. The assay was linear up to 3000 pmol/L with lower limit of quantitation at 80 pmol/L. The mean relative recovery was 96.5% with a range of 89.3-101.6% for aqueous calibrators and the mean relative recovery was 94.8% with a range of 87.5-101.4% for serum calibrators. Intra-assay CVs range from 8.2% to 11.3%, and inter-assay CVs ranged from 8.5% to 13.5% at concentration range from 229 to 1720 pmol/L. The LC-MS/MS method compared well (y = 1.04x + 8.97) with the in-use radioimmunoassay method. There was no significant difference found (p = 0.7135) between results determined by LC-MS/MS and radioimmunoassay method.


Assuntos
Aldosterona/sangue , Hiperaldosteronismo/sangue , Espectrometria de Massas em Tandem/métodos , Adulto , Idoso , Calibragem , Cromatografia Líquida/métodos , Feminino , Humanos , Hiperaldosteronismo/diagnóstico , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA