Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
J Card Surg ; 36(11): 4054-4060, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34423475

RESUMO

BACKGROUND: Aortic cusp extension is a technique for aortic valve (AV) repairs in pediatric patients. The choice of the material used in this procedure may influence the time before reoperation is required. We aimed to assess postoperative and long-term outcomes of patients receiving either pericardial or synthetic repairs. METHODS: We conducted a single-center, retrospective study of pediatric patients undergoing aortic cusp extension valvuloplasty (N = 38) with either autologous pericardium (n = 30) or CorMatrix (n = 8) between April 2009 and July 2016. Short- and long-term postoperative outcomes were compared between the two groups. Freedom from reoperation was compared using Kaplan-Meier analysis. Degree of aortic stenosis (AS) and aortic regurgitation (AR) were recorded at baseline, postoperatively, and at outpatient follow-up. RESULTS: At 5 years after repair, freedom from reoperation was significantly lower in the CorMatrix group (12.5%) compared to the pericardium group (62.5%) (p = .01). For the entire cohort, there was a statistically significant decrease in the peak trans-valvar gradient between preoperative and postoperative assessments with no significant change at outpatient follow-up. In the pericardium group, 28 (93%) had moderate to severe AR at baseline which improved to 11 (37%) postoperatively and increased to 21 (70%) at time of follow-up. In the biomaterial group, eight (100%) had moderate to severe AR which improved to three (38%) postoperatively and increased to seven (88%) at time of follow-up. CONCLUSION: In terms of durability, the traditional autologous pericardium may outperform the new CorMatrix for AV repairs using the cusp extension method.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Procedimentos Cirúrgicos Cardíacos , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Criança , Humanos , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
2.
Pediatr Cardiol ; 41(7): 1458-1465, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32607741

RESUMO

Mitral valve replacement (MVR) in children under 2 years is associated with significant morbidity and mortality. Decellularized porcine intestinal submucosa is a commercially available formulation of an extracellular matrix (ECM) with an indication for cardiac tissue repair. The present study reports our experience using ECM cylinder valves in patients for MVR. A retrospective review of patients under 2 years who underwent ECM custom-made cylinder mitral valve (ECM-MV) replacement was performed. Clinical, demographic, operative and post-operative follow-up data, including serial echocardiographic data are presented. Eight patients (age 5.6 ± 1.6 months; weight: 6.0 ± 1.1 kg) were identified who underwent ECM-MVR. There was one in-hospital death and no major neurological events. Six patients underwent replacement of their cylinder valve with either a Melody valve inside the ECM-MVR (n = 3), a mechanical valve (n = 2), or a decellularized bovine pericardial cylinder valve (n = 1). The mean time to replacement surgery was 8.4 ± 2.6 months after ECM-MV. The indications for replacement of ECM-MV included mitral stenosis/regurgitation (n = 4) or dehiscence (n = 2). One remaining patient is 24 months from ECM-MV, with trivial regurgitation and no stenosis. Mitral valve creation using ECM is an option for MVR in pediatrics, avoiding anticoagulation, and provides a suitable construct for later placement of a Melody valve, extending surgical and non-surgical options. However, the durability of the native ECM-MV in the mitral position is concerning considering the high re-intervention rate in a relatively short time period. Further studies are needed to determine the longer-term outcomes of this valve in this complex patient population.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Ecocardiografia , Matriz Extracelular/transplante , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Resultado do Tratamento
3.
Cardiovasc Ultrasound ; 15(1): 21, 2017 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-28893257

RESUMO

BACKGROUND: Second-stage palliation with hemi-Fontan or bidirectional Glenn procedures has improved the outcomes of patients treated for single-ventricle heart disease. The aim of this study was to retrospectively analyze risk factors for death after second-stage palliation of single-ventricle heart and to compare therapeutic results achieved with the hemi-Fontan and bidirectional Glenn procedures. MATERIAL AND METHODS: We analyzed 60 patients who had undergone second-stage palliation for single-ventricle heart. Group HF consisted of 23 (38.3%) children who had been operated with the hemi-Fontan method; Group BDG consisted of 37 (61.7%) who had been operated with the bidirectional Glenn method. The analysis focused on 30-day postoperative mortality rates, clinical and echocardiographic data, and early complications. RESULTS: The patients' ages at the time of repair was 33 ± 11.2 weeks; weight was 6.7 ± 1.2 kg. The most common anatomic subtype was hypoplastic left heart syndrome, in 36 (60%) patients. The early mortality rate was 13.3%. Significant preoperative atrioventricular valve regurgitation, single-ventricle heart dysfunction, pneumonia/sepsis, and arrhythmias were associated with higher mortality rates after second-stage palliation. Multivariate analysis identified significant preoperative single-ventricle heart dysfunction as an independent predictor of early death after second-stage palliation. No differences were found in the analyzed variables after bidirectional Glenn compared with hemi-Fontan procedures. CONCLUSION: Significant preoperative atrioventricular valve regurgitation, arrhythmias and pneumonia/sepsis are closely correlated with mortality in patients with single-ventricle heart after second-stage palliation. Preoperative significant single-ventricle heart dysfunction is an independent mortality predictor in this group of patients. There are no differences in clinical, echocardiographic data, or outcomes in patients treated with the hemi-Fontan compared with bidirectional Glenn procedures.


Assuntos
Técnica de Fontan/métodos , Ventrículos do Coração/fisiopatologia , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Cuidados Paliativos/métodos , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração/anormalidades , Ventrículos do Coração/cirurgia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Lactente , Masculino , Período Pré-Operatório , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Interact Cardiovasc Thorac Surg ; 34(4): 597-603, 2022 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-34687545

RESUMO

OBJECTIVES: The aim of this retrospective study was to determine if Cormatrix® (CM) represents a safe alternative to conventional patch materials used in congenital heart surgery. METHODS: A total of 57 paediatric patients who underwent cardiac surgery using an Extracellular Matrix Bioscaffold (CM) were categorized into 4 groups according to the patch implant location. Patch-related complications and reintervention rates were analysed. A subgroup of 18 patients was subsequently compared to a matched group of 36 patients who underwent similar surgical procedures with autologous pericardium as patch material. RESULTS: No patient died during hospitalization. There were 2 late deaths, not related to the implanted CM patch. Fourteen (66.7%) out of 21 patients with arterial patch plasty developed progressive vessel/right ventricular outflow tract stenosis or aneurysm. All 3 patients with a valved CM conduit developed haemodynamically relevant valve stenosis or regurgitation. A total of 18 (31.5%) patients needed reintervention and 12 (21.1%) related to CM. Four (7%) patients needed surgical treatment with operative removal of the stenosis. Redo valve replacement was performed on 2 (3.5%) patients. Six (10.5%) patients required an interventional cardiology procedure at a median interval of 5 months from surgery. The subgroup analysis revealed a significantly lower patch-related reintervention rate in patients treated with autologous pericardium when compared to CM (P = 0.006). CONCLUSIONS: CM is safe for atrial and ventricular defect closure. The use of CM for arterial vessel reconstruction is associated with higher reintervention rates when compared to autologous pericardium.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração , Humanos , Pericárdio , Estudos Retrospectivos , Resultado do Tratamento
5.
Materials (Basel) ; 14(14)2021 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-34300779

RESUMO

The use of extracellular matrix (ECM) biomaterials for soft tissue repair has proved extremely successful in animal models and in some clinical settings. The aim of the study was to investigate the effect of the commercially obtained CorMatrix bioscaffold on the viability, proliferation and migration of rat pheochromocytoma cell line PC12. PC12 cells were plated directly onto a CorMatrix flake or the well surface of a 12-well plate and cultured in RPMI-1640 medium and a medium supplemented with the nerve growth factor (NGF). The surface of the culture plates was modified with collagen type I (Col I). The number of PC12 cells was counted at four time points and then analysed for apoptosis using a staining kit containing annexin V conjugate with fluorescein and propidium iodide (PI). The effect of CorMatrix bioscaffold on the proliferation and migration of PC12 cells was tested by staining the cells with Hoechst 33258 solution for analysis using fluorescence microscopy. The research showed that the percentage of apoptotic and necrotic cells was low (less than 7%). CorMatrix stimulates the proliferation and possibly migration of PC12 cells that populate all levels of the three-dimensional architecture of the biomaterial. Further research on the mechanical and biochemical capabilities of CorMatrix offers prospects for the use of this material in neuro-regenerative applications.

6.
J Clin Transl Pathol ; 1(1): 9-15, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34957472

RESUMO

BACKGROUND AND OBJECTIVES: CorMatrix acts as a tissue scaffold and is intended to promote the proliferation of small vessels and tissue remodeling to replicate normal tissue function. METHODS: At Temple University Hospital, Philadelphia, PA, USA from 2013 to 2016, CorMatrix material was utilized during mitral valve anterior leaflet augmentation repair in 25 adult patients, and four patients required repeat interventions at 4-12 months (8.25 ± 4.35 months) after the initial repair. This study evaluated the pathological changes in four patients. RESULTS: Histological examination of the CorMatrix showed matrix degradation in all cases. At 4 months after repair, mixed acute and chronic inflammatory cells that included eosinophils were visible within the matrix, which was more severe around the suture material. Later, the extent of inflammation abated and became more chronic with macrophage dominance. Some macrophages and multinucleated cells were visible deep in the matrix. The neovascularization was limited to the tissue-matrix boundary at early time points; the more mature vessels with dilated lumens extended deeper into the matrix as time increased, combined with some elongated fibroblast-like cells. In addition, marked acute and chronic inflammation with neutrophil and eosinophil infiltrate was identified in the surrounding native tissue at 4 months, especially around the suture material. Marked granulomatous inflammation was identified in all cases, with prominent multinucleated giant cells present at later time points (50%). Immunohistochemical staining for CD68 and CD163 showed prominent M2 macrophages in the CorMatrix and surrounding tissue. CONCLUSIONS: Our results demonstrated time-dependent changes in failed CorMatrix repaired valves after mitral valve repair, with macrophages and neovascularization in the matrix 12 months after the initial repair.

7.
Interact Cardiovasc Thorac Surg ; 32(6): 978-987, 2021 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-33595082

RESUMO

OBJECTIVES: Entire mitral valve reconstruction with an extracellular matrix tube graft is a potential candidate to overcome the current limitations of mechanical and bioprosthetic valves. However, clinical data have raised concern with respect to patch failure. The aim of our study was to evaluate the impact of extracellular matrix mitral tube graft implantation on mitral annular and subvalvular regional dynamics in pigs. METHODS: A modified tube graft design made of 2-ply extracellular matrix was used (CorMatrix®; Cardiovascular Inc., Alpharetta, GA, USA). The reconstructions were performed in an acute 80-kg porcine model (N = 8), where each pig acted as its own control. Haemodynamics were assessed with Mikro-Tip pressure catheters and mitral annular and subvalvular geometry and dynamics with sonomicrometry. RESULTS: Catheter-based peak left atrial pressure and pressure difference across the mitral and aortic valves in the reconstructions were comparable to the values seen in the native mitral valves. Also comparable were maximum mitral annular area (755 ± 100 mm2), maximum septal-lateral distance (29.7 ± 1.7 mm), maximum commissure-commissure distance (35.0 ± 3.4 mm), end-systolic annular height-to-commissural width ratio (10.2 ± 1.0%) and end-diastolic interpapillary muscle distance (27.7 ± 3.3 mm). Systolic expansion of the mitral annulus was, however, observed after reconstruction. CONCLUSIONS: The reconstructed mitral valves were fully functional without regurgitation, obstruction or stenosis. The reconstructed mitral annular and subvalvular geometry and subvalvular dynamics were found in the same range to those in the native mitral valve. A regional annular ballooning effect occurred that might predispose to patch failure. However, the greatest risk was found at the papillary muscle attachments.


Assuntos
Insuficiência da Valva Mitral , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Matriz Extracelular , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Músculos Papilares , Suínos
8.
J Thorac Dis ; 12(3): 1070-1078, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32274175

RESUMO

BACKGROUND: Many valvular pathologies of the heart may be only sufficiently treated by replacement of the valve if a reconstruction is not feasible. However, structural deterioration, thrombosis with thromboembolic events and infective endocarditis are commonly encountered complications over time and often demand a re-operation. In congenital heart disease the lack of small diameter valves with the potential to grow poses additional challenges and limits treatment options to homo- or xenograft implants. METHODS: In this study, a chronic sheep model (24 months follow-up), a self-constructed valved conduit was created out of a tissue engineered (TE) patch (CorMatrix® Cardiovascular, Inc, USA) and implanted in orthotopic right ventricular (RV)-pulmonary artery (PA) position. Thereafter, the sheep were regularly monitored by clinical, laboratory and echocardiographic examinations to evaluate cardiac function and the implanted RV-PA-conduit. DISCUSSION: Here, we summarize the study protocol and our experiences during the perioperative phase and the follow up period and explain how we constructed a valved conduit out of a commercially available TE patch. TRIAL REGISTRATION: License number: ZH 284/14.

9.
Front Cardiovasc Med ; 7: 562136, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33195455

RESUMO

In children with Transposition of the Great Arteries (TGA), the pulmonary artery, and aorta are connected to the heart abnormally resulting in blue blood (deoxygenated) recirculating to the body and red blood (oxygenated) recirculating to the lungs. The arterial switch operation (ASO) is the standard of care for transposition of the great arteries (TGA), and given the low risk of early mortality and satisfactory long-term outcomes, focus is now on managing longer term complications such as neo-aortic root dilatation, and pulmonary artery stenosis. Since May 2016, we have used 2-ply extracellular matrix (ECM; Tyke) for reconstruction of the coronary button defects using a pantaloon patch. We present histology of implanted 2-ply ECM (Tyke) from a patient who went back to surgery for development of subaortic stenosis ~12 months after ASO.

10.
J Thorac Cardiovasc Surg ; 160(1): 102-112, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31548077

RESUMO

OBJECTIVE: The objective of our study was to investigate the feasibility of reconstructing the entire mitral valvular and subvalvular apparatus in pigs using a modified tube graft design made of 2-ply small intestinal submucosa extracellular matrix. METHODS: The reconstructions were performed in an acute 80-kg porcine model with 8 pigs, each acting as its own control. A modified tube graft was designed from a sheet of 2-ply small intestinal submucosa extracellular matrix. Before and after mitral valve reconstruction, echocardiography was used to assess mitral regurgitation, left ventricular outflow tract obstruction due to systolic anterior motion, mitral stenosis, leaflet mobility, and leaflet geometry. RESULTS: The reconstructed mitral valves were fully functional without any observable echocardiographic signs of regurgitation. We did not observe any left ventricular outflow tract obstruction due to systolic anterior motion nor any mitral valve stenosis, despite a diminished septal-lateral distance after reconstruction. The reconstruction had a reduced tenting area, a reduced coaptation length (9.6 ± 1.7 mm vs 7.9 ± 1.0 mm, P = .010, diff = -1.7 mm, 95% confidence interval, -3.1 to -0.4 mm), and atrial bending of both leaflets. CONCLUSIONS: In this acute porcine study, entire mitral valvular and subvalvular apparatus reconstruction using a modified tube graft design made from 2-ply small intestinal submucosal extracellular matrix was feasible. The 2-ply small intestinal submucosa extracellular matrix could withstand the pressure exerted by the left ventricle without any signs of tearing or rupture. These promising results warrant further assessment of both the annular geometry and the long-term durability.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Matriz Extracelular/transplante , Valva Mitral/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Animais , Procedimentos Cirúrgicos Cardíacos/instrumentação , Ecocardiografia , Feminino , Mucosa Intestinal/citologia , Mucosa Intestinal/transplante , Intestino Delgado/citologia , Intestino Delgado/transplante , Insuficiência da Valva Mitral , Procedimentos de Cirurgia Plástica/instrumentação , Suínos , Obstrução do Fluxo Ventricular Externo
11.
Cardiovasc Eng Technol ; 11(4): 405-415, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32592143

RESUMO

PURPOSE: To investigate the anatomical and functional effects of complete surgical reconstruction of the posterior mitral leaflet and associated chordae tendineae with a patch made of 2-ply small intestinal submucosal extracellular matrix in vitro. METHODS: Seven explanted mitral valves with intact subvalvular apparatus from 80-kg pigs were evaluated in a left heart simulator and served as their own controls. After testing the native valve, the mitral posterior leaflet and associated chordae tendineae were excised and reconstructed by using the 2-ply small intestinal submucosa extracellular matrix patch. The characterization of the reconstruction was based on geometric data from digital images, papillary muscle force, annular tethering force and leaflet pressure force. RESULTS: The reconstructed valves were fully functional without regurgitation, tearing or rupture during incrementally increased pressure from 0 to 120 mmHg. The leaflet areas were preserved after reconstruction, with a normal configuration of the coaptation line. However, the coaptation midpoint moved posteriorly after reconstruction (A2: 15.8 ± 1.4 vs. 18.9 ± 1.5 mm, p = 0.002, diff = 3.1 mm, 95% CI 1.3 to 4.8 mm). The anterior papillary muscle force increased significantly (3.9 vs. 4.6 N, p = 0.029, diff = 0.7 N, 95% CI 0.1 to 1.4 N at 120mmHg) after reconstruction. The posterior papillary muscle force, leaflet pressure force and annular pressure force did not change significantly. CONCLUSIONS: In this in vitro model, mitral valve anatomy and function were comparable between the native mitral valve and our new surgical technique for complete reconstruction of the posterior mitral leaflet and associated chordae tendineae. These promising results warrant further in vivo evaluation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cordas Tendinosas/cirurgia , Matriz Extracelular/transplante , Intestino Delgado/transplante , Valva Mitral/cirurgia , Animais , Cordas Tendinosas/fisiopatologia , Hemodinâmica , Valva Mitral/fisiopatologia , Modelos Animais , Sus scrofa
12.
Cardiovasc Eng Technol ; 11(6): 748-759, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33200342

RESUMO

PURPOSE: Patch reconstruction of the posterior mitral leaflet using small intestinal submucosa extracellular matrix has been successfully performed in a porcine study. The patch reconstruction, however, resulted in non-physiological systolic widening of the mitral annulus, suggesting the need for an annuloplasty ring. The objective was to characterize the impact on annular dynamics and leaflet geometry of adding a flexible annuloplasty ring to the posterior mitral leaflet patch reconstruction. METHODS: Measurements were performed in an acute 80-kg porcine model, with seven pigs acting as their own controls. The posterior mitral leaflet was reconstructed with a 2-ply small intestinal submucosa extracellular matrix patch (CorMatrix®). Additionally, a Simulus® Flexible Annuloplasty Ring (Medtronic Inc., Minneapolis, MN, USA) was inserted. Mitral annular dynamics were evaluated using sonomicrometry, and leaflet geometry was described using echocardiography. RESULTS: The annuloplasty ring reduced mitral annular dimensions and restricted cyclic changes in mitral annular area (126 ± 19 vs. 30 ± 13 mm2, p < 0.001), septal-lateral and commisure-commisure distances. Ring annuloplasty prevented systolic widening in the mitral annulus after posterior mitral leaflet reconstruction. The annular saddle shape and leaflet coaptation length (8.7 ± 2.3 vs. 9.7 ± 1.3 mm, p = 0.221) were comparable before and after ring insertion. CONCLUSIONS: The flexible annuloplasty ring resulted in a downsized annulus with restriction of cyclic annular changes in the reconstructed mitral valve. Ring insertion preserved the annular saddle shape and coaptation length. The ring annuloplasty counteracted the non-physiological annular dynamics, and this may improve durability of the posterior mitral leaflet patch reconstruction.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Anuloplastia da Valva Mitral/instrumentação , Valva Mitral/cirurgia , Animais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Anuloplastia da Valva Mitral/efeitos adversos , Desenho de Prótese , Sus scrofa
14.
Cardiovasc Pathol ; 39: 54-60, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30660869

RESUMO

The search for an ideal material for cardiac tissue repair has led to utilization of porcine small intestinal submucosa extracellular matrix (CorMatrix). Here, we examine the histologic features of CorMatrix and the associated cellular growth at a variety of time intervals. Tissues with CorMatrix from ten patients (4 male, 6 female) with ages ranging from 2 weeks to 2 years, and implant duration ranging from 1 week to 2 years were included in this study. Samples for analysis were collected at autopsy. Surgical repair sites included great vessel repair (n=9), atrial septum defect (n=1), coronary vessels (n=1), as well as aortic (n=1) and mitral valve (n=2) leaflets. In all specimens, CorMatrix was composed of dense laminated regions of collagen, without appreciable elastin staining. In most grafts, especially those implanted for extended periods of time, tissue with luminal CD31 positivity covered the intimal surface of the CorMatrix graft. This tissue (neo-intima) consisted of spindled myofibroblasts (SMA) and small CD31 positive vessels with occasional mononuclear cells in a matrix composed of collagen, glycosaminoglycans, and rarely elastin, after extended periods of implantation. These features were readily identified in patients as early as 1 month after CorMatrix implantation. The matrix comprising the CorMatrix itself remained largely acellular, despite implantation times up to 2 years, with degradation of the graft material. We provide a framework for histologic expectations when evaluating explanted CorMatrix grafts. In this regard, the CorMatrix matrix is likely to remain acellular without significant elastin deposition, whereas the intimal and adventitial surfaces become coated by proliferating cells in a novel matrix of collagen and glycosaminoglycans.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Proliferação de Células , Matriz Extracelular/transplante , Cardiopatias Congênitas/cirurgia , Intestino Delgado/transplante , Animais , Autopsia , Biópsia , Pré-Escolar , Colágeno/metabolismo , Matriz Extracelular/metabolismo , Matriz Extracelular/patologia , Feminino , Glicosaminoglicanos/metabolismo , Cardiopatias Congênitas/metabolismo , Cardiopatias Congênitas/patologia , Xenoenxertos , Humanos , Lactente , Intestino Delgado/metabolismo , Intestino Delgado/patologia , Masculino , Propriedades de Superfície , Sus scrofa , Fatores de Tempo , Resultado do Tratamento
15.
Eur J Cardiothorac Surg ; 55(6): 1095-1103, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30597010

RESUMO

OBJECTIVES: To investigate the feasibility of reconstruction of the entire mitral valve using a tube graft made of 2-ply small intestinal submucosa extracellular matrix in vitro. METHODS: Seven explanted mitral valves with intact subvalvular apparatus from 80 kg pigs were evaluated in a left heart simulator and served as controls. After testing the native valve, the leaflets and chordae tendineae were explanted, and the 2-ply small intestinal submucosa extracellular matrix (CorMatrix®; Cardiovascular Inc., Alpharetta, GA, USA) tube graft was implanted. The characterization was based on geometric data from digital images, papillary muscle force, annular tethering force and leaflet pressure force. RESULTS: The tube grafts were fully functional without any signs of leakage, tearing or rupture during incrementally increased pressures from 0 mmHg to 120 mmHg. The posterior leaflet moved anteriorly and became larger after reconstruction when compared with the native valve. However, the mid coaptation point was preserved. The anterior papillary muscle force decreased significantly (5.2 N vs 4.4 N, P = 0.022 at 120 mmHg), and the posterior papillary muscle force increased significantly (4.8 N vs 5.6 N, P = 0.017 at 120 mmHg) after reconstruction. CONCLUSIONS: The entire mitral valvular and subvalvular reconstruction with a 2-ply small intestinal submucosa extracellular matrix tube graft is feasible in an in vitro model. Our method of reconstruction increased the convexity of the anterior leaflet's coaptation line and significantly redistributed the papillary muscle force towards the posterior papillary muscle. These promising results and the prospect of the entire mitral valvular and subvalvular reconstruction warrant further in vivo evaluations.


Assuntos
Cordas Tendinosas/cirurgia , Matriz Extracelular , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Músculos Papilares/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Animais , Fenômenos Biomecânicos , Cordas Tendinosas/fisiopatologia , Modelos Animais de Doenças , Ecocardiografia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Músculos Papilares/fisiopatologia , Desenho de Prótese , Suínos
16.
Kardiol Pol ; 76(4): 770-775, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29350395

RESUMO

BACKGROUND: In the period from 2003 to the end of 2015, 96 Norwood I procedures were performed in the Paediatric Heart Surgery Department in Katowice, Poland, in children with hypoplastic left heart syndrome (HLHS). AIM: This paper presents a retrospective analysis of early surgical results. METHODS: The patients consisted of two groups: group I included 59 children operated on in the years 2003-2012, in whom the stage I Norwood procedure with the Sano modification was performed with the aortic arch reconstructed by use of a ho-mogenous pulmonary artery patch or a bovine pericardial patch. Group II included 37 children after our modification of the Norwood I procedure, in which the aortic arch was reconstructed with an extracellular matrix patch and bilateral pulmonary artery banding was done. RESULTS: Aortic cross-clamping time was significantly shorter in group II (mean 52; range 38-62 min) than in group I (mean 57; range 39-72 min; p < 0.009). Eighteen (30.5%) children in group I and six (16.2%) in group II died. Although this dif-ference did not reach statistical significance (p = 0.12), it suggested that improved outcomes with the modified procedure are possible. The cause of death in group I was significantly more frequently due to massive postoperative bleeding (n = 6; 33.3%) than in group II (n = 1; 16.7%; p = 0.046). CONCLUSIONS: The introduction of this new surgical technique reduced postoperative bleeding rates, shortened the operation time, and might improve the mortality rate in the first-stage surgical treatment of children with HLHS.


Assuntos
Aorta Torácica/cirurgia , Coartação Aórtica/etiologia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Procedimentos de Norwood/estatística & dados numéricos , Procedimentos de Cirurgia Plástica/métodos , Coartação Aórtica/cirurgia , Criança , Feminino , Humanos , Masculino , Polônia , Recidiva , Reoperação , Estudos Retrospectivos
17.
Eur J Cardiothorac Surg ; 53(2): 472-474, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28958011

RESUMO

Surgical venous bypass is an effective treatment option in the management of benign superior vena caval obstruction. Here, we present CorMatrix® as a novel conduit choice, supported internally by an endovascular stent in an attempt to prevent stenosis and reduce reintervention rate following surgical bypass.


Assuntos
Stents , Síndrome da Veia Cava Superior/cirurgia , Procedimentos Cirúrgicos Vasculares/instrumentação , Procedimentos Cirúrgicos Vasculares/métodos , Humanos
18.
Congenit Heart Dis ; 13(6): 997-1004, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30242970

RESUMO

BACKGROUND: Congenital heart defects affect nearly 1% of all children born per year in the United States, and complete atrioventricular canal (CAVC) accounts for 2%-9%. While several patch materials have been used for septal defect closure during CAVC repair, clear superiority of one material over another has yet to be established. METHODS: A retrospective review of clinical outcomes following CAVC repair at Morgan Stanley Children's Hospital/Columbia University was performed on operations conducted from March 2010 to September 2017. Univariate and Kaplan-Meir survival analyses were utilized to evaluate primary outcomes of interest following CAVC repair in the modern surgical era. RESULTS: A total of 73 patients were analyzed, with an average operative age of 22 weeks. The majority (71%) of the patients underwent a 2-patch repair. A CorMatrix patch was used for ventricular septal defect(VSD) closure in 77% of the patients, and/or in 75% of atrial septal defect closures. There was one in-hospital mortality (1.4%) due to respiratory failure. One patient required a pacemaker. At mid-term follow-up (1.6 years), a total of 7 patients required 8 reoperations due to cardiac-related indications, including 5 for left atrioventricular valve (LAVV) repair, 1 for LAVV replacement, and 2 isolated residual VSDs. CONCLUSION: A standardized repair for CAVC results in excellent outcomes in the current era, with low rates of reoperations. CorMatrix for the closure of CAVC has proven to produce good results with equivalent outcomes to other patch materials. Its ease of use and pliability make it an attractive alternative for consideration.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Defeitos dos Septos Cardíacos/cirurgia , Mucosa Intestinal/transplante , Intestino Delgado/transplante , Animais , Feminino , Defeitos dos Septos Cardíacos/mortalidade , Humanos , Lactente , Recém-Nascido , Intestino Delgado/citologia , Masculino , New York/epidemiologia , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Suínos , Resultado do Tratamento
19.
Eur Heart J Case Rep ; 2(3): yty086, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31020163

RESUMO

BACKGROUND: Due to increased morbidity and mortality, prosthetic valve infective endocarditis (IE) with dehiscence requires urgent intervention. Early identification and therapy may prevent embolization. CASE SUMMARY: A 27-year-old Caucasian woman with a history of hepatitis C, intravenous drug abuse, and tricuspid valve (TV) replacement was admitted for recurrent IE. She was found to have bacteraemia and fungaemia, and empiric antibiotics were initiated. Transthoracic echocardiogram (TTE) revealed a mobile 'mass' on the TV and dehiscence. The patient developed cardiogenic shock and repeat TTE showed a ruptured TV and absence of the 'mass', suspicious of embolization. She underwent emergent surgery with TV replacement using a Biocor valve and retrieval of the old CorMatrix valve found in the right mid pulmonary artery (PA). The patient was successfully weaned off inotropic agents and completed a prolonged course of antibiotics and anti-fungals. DISCUSSION: The multi-disciplinary decision on timing of surgical intervention was challenging, especially due to ongoing mycobacterial infection that increased operative risk. With clinical deterioration, urgent surgery was performed revealing an embolized prosthetic valve in the PA. New surgical options for TV replacement in IE with extracellular-based material have shown promising outcomes with little reported data of long term complications. This case demonstrates a rare occurrence of embolized CorMatrix TV and highlights the challenge in timing of appropriate surgical intervention in a septic patient with thrombocytopenia.

20.
J Ultrason ; 18(72): 71-76, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29844944

RESUMO

BACKGROUND: In the present paper, the authors describe a case of a rare congenital defect - anomalous origin of the right coronary artery from the main pulmonary artery diagnosed in a 5-week-old infant who was deemed eligible for surgical treatment based solely on echocardiography. Such anatomical abnormalities of the coronary arteries are subtle and thus extremely difficult to visualize, especially in patients in whom permanent extensive damage of the cardiac muscle has not yet occurred. For this reason, the diagnosis is usually established when the disease is highly advanced, oftentimes only postmortem. In this paper, the authors present early echocardiographic evaluation, successful surgical treatment and post-operative echocardiographic examination. CASE PRESENTATION: Fetal echocardiographic examinations demonstrated single vascular anomalies. The suspicion was verified after birth. Other congenital defects, including genetic defects, were also investigated. In the 5th week of life, cardiac ECHO showed abnormal origin of the right coronary artery from the trunk of the pulmonary artery. The child was deemed eligible for surgical treatment of the defect. The surgical translocation of the ostium of the right coronary artery to the aorta was done with success, and the child was discharged on the 14th day of hospitalization. CONCLUSION: The present case report demonstrates that careful examination of the child with precise echocardiographic examination makes it possible to establish an early diagnosis of this rare defect. This discrete defect can be treated early, before the symptoms, often connected with irreversible changes in the myocardium, appear.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA