RESUMO
Herpes simplex virus (HSV) infections are one of the most common and stigmatized infections of humankind, affecting more than 4 billion people around the world and more than 100 million Americans. Yet, most people do not know their infection status, and antibody testing is not recommended, partly due to poor test performance. Here, we compared the test performance of the Roche Elecsys HSV-1 IgG and HSV-2 IgG, DiaSorin LIAISON HSV-1/2 IgG, and Bio-Rad BioPlex 2200 HSV-1 and HSV-2 IgG assays with the gold-standard HSV western blot in 1,994 persons, including 1,017 persons with PCR or culture-confirmed HSV-1 and/or HSV-2 infection. Across all samples, the Bio-Rad and Roche assays had similar performance metrics with low sensitivity (<85%) but high specificity (>97%) for detecting HSV-1 IgG and both high sensitivity (>97%) and high specificity (>98%) for detecting HSV-2 IgG. The DiaSorin assay had a higher sensitivity (92.1%) but much lower specificity (88.7%) for detecting HSV-1 IgG and comparatively poor sensitivity (94.5%) and specificity (94.2%) for detecting HSV-2 IgG. The DiaSorin assay performed poorly at low-positive index values with 60.9% of DiaSorin HSV-1 results and 20.8% of DiaSorin HSV-2 results with positive index values <3.0 yielding false positive results. Based on an estimated HSV-2 seroprevalence of 12% in the United States, positive predictive values for HSV-2 IgG were 96.1% for Roche, 87.4% for Bio-Rad, and 69.0% for DiaSorin, meaning nearly one of every three positive DiaSorin HSV-2 IgG results would be falsely positive. Further development in HSV antibody diagnostics is needed to provide appropriate patient care.IMPORTANCESerological screening for HSV infections is currently not recommended in part due to the poor performance metrics of widely used commercial HSV-1 and HSV-2 IgG assays. Here, we compare three Food and Drug Administration (FDA)-cleared automated HSV-1 and HSV-2 IgG assays to the gold-standard western blot across nearly 2,000 samples. We find that not all commercially available HSV assays are created equal, with comparably low sensitivities for HSV-1 IgG across platforms and high false positivity rates for DiaSorin on HSV-2 IgG. This study is the first large-scale comparison of performance metrics for the Bio-Rad and Roche assays in over 10 years. Our study confirms that there remains room for improvement in HSV serological diagnostic testing-especially in regard to low sensitivities for HSV-1 IgG detection-and highlights that some previously less-studied assays may have better performance metrics than previously considered typical of commercially available HSV-2 IgG assays.
Assuntos
Anticorpos Antivirais , Herpes Simples , Herpesvirus Humano 1 , Herpesvirus Humano 2 , Imunoglobulina G , Sensibilidade e Especificidade , Humanos , Imunoglobulina G/sangue , Herpesvirus Humano 1/imunologia , Herpesvirus Humano 2/imunologia , Herpesvirus Humano 2/isolamento & purificação , Anticorpos Antivirais/sangue , Herpes Simples/diagnóstico , Herpes Simples/virologia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adolescente , Adulto Jovem , Idoso , Automação Laboratorial , Criança , Idoso de 80 Anos ou mais , Imunoensaio/métodos , Pré-EscolarRESUMO
The information provided by SARS-CoV-2 spike (S)-targeting immunoassays can be instrumental in clinical-decision making. We compared the performance of the Elecsys® Anti-SARS-CoV-2 S assay (Roche Diagnostics) and the LIAISON® SARS-CoV-2 TrimericS IgG assay (DiaSorin) using a total of 1176 sera from 797 individuals, of which 286 were from vaccinated-SARS-CoV-2/experienced (Vac-Ex), 581 from vaccinated/naïve (Vac-N), 147 from unvaccinated/experienced (Unvac-Ex), and 162 from unvaccinated/naïve (Unvac-N) individuals. The Roche assay returned a higher number of positive results (907 vs. 790; p = 0.45; overall sensitivity: 89.3% vs. 77.6%). The concordance between results provided by the two immunoassays was higher for sera from Vac-N (Ï°: 0.58; interquartile ranges [IQR]: 0.50-0.65) than for sera from Vac-Ex (Ï°: 0.19; IQR: -0.14 to 0.52) or Unvac-Ex (Ï°: 0.18; IQR: 0.06-0.30). Discordant results occurred more frequently among sera from Unvac-Ex (34.7%) followed by Vac-N (14.6%) and Vac-Ex (2.7%). Antibody levels quantified by both immunoassays were not significantly different when <250 (p = 0.87) or <1000 BAU/ml (p = 0.13); in contrast, for sera ≥1000 BAU/ml, the Roche assay returned significantly higher values than the DiaSorin assay (p < 0.008). Neutralizing antibody titers (NtAb) were measured in 127 sera from Vac-Ex or Vac-N using a S-pseudotyped virus neutralization assay of Wuhan-Hu-1, Omicron BA.1, and Omicron BA.2. The correlation between antibody levels and NtAb titers was higher for sera from Vac-N than those from Vac-Ex, irrespective of the (sub)variant considered. In conclusion, neither qualitative nor quantitative results returned by both immunoassays are interchangeable. The performance of both assays was found to be greatly influenced by the vaccination and SARS-CoV-2 infection status of individuals.
Assuntos
Vacinas contra COVID-19 , COVID-19 , Humanos , Luminescência , COVID-19/diagnóstico , SARS-CoV-2 , Vacinação , Anticorpos Antivirais , Imunoglobulina G , Anticorpos Neutralizantes , ImunoensaioRESUMO
BACKGROUND: 1,25-dihydroxyvitamin D (1,25(OH)2D), the biologically active vitamin D metabolite, plays a critical role in calcium and phosphate homeostasis. 1,25(OH)2D is measured to assess calcium and phosphate metabolism, particularly during periods of profound growth and development. Despite its importance, no reliable pediatric reference interval exists, with those available developed using adult populations or out-dated methodologies. Using the fully automated chemiluminescence immunoassay by DiaSorin, we established 1,25(OH)2D pediatric reference intervals using healthy children and adolescents from the CALIPER cohort. METHODS: Serum samples from healthy subjects (0 to <19 years) were analyzed for 1,25(OH)2D using the DiaSorin LIAISON XL assay and age-specific reference intervals were established. The Mann-Whitney U-test was used to determine seasonal differences. Pooled neonatal and infantile samples were quantified using liquid chromatography tandem mass spectrometry (LC-MS/MS) to determine if elevated concentrations during the first year of life may be attributed to cross-reacting moieties. RESULTS: Three reference interval age partitions were required with highest levels in subjects 0 to <1 year (77-471 pmol/L), which declined and narrowed after 1 year (113-363 pmol/L) and plateaued at 3 years (108-246 pmol/L). 1,25(OH)2D concentration was not significantly affected by seasonal variation or sex. Elevated 1,25(OH)2D concentrations in neonatal and infantile samples may be the result of an interfering substance. The absence of 3-epi-1,25-dihydroxyvitamin D in the pooled samples makes it unlikely to be the interfering moiety. CONCLUSIONS: Pediatric reference intervals for 1,25(OH)2D were established to improve test result interpretation in children and adolescents. 1,25(OH)2D is elevated in a proportion of neonates and infants, which may be the result of a cross-reacting moiety.
Assuntos
Vitamina D/análogos & derivados , Adolescente , Criança , Cromatografia Líquida , Estudos de Coortes , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Valores de Referência , Estações do Ano , Espectrometria de Massas em Tandem , Vitamina D/sangueRESUMO
OBJECTIVES: Prominent physiological changes occurring throughout childhood and adolescence necessitate the consideration of age and sex in biomarker interpretation. Critical gaps exist in pediatric reference intervals (RIs) for specialized endocrine markers, despite expected influence of growth and development. The current study aimed to establish and/or verify RIs for six specialized endocrine markers on a specialized immunoassay system. METHODS: Samples were collected from healthy children and adolescents (5 to <19 years) and apparently healthy outpatients (0 to <5 years) as part of the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER). Serum samples were analysed for aldosterone, renin (plasma), thyroglobulin, anti-thyroglobulin, growth hormone, and insulin-like growth factor-1 (IGF-1) on the Liaison XL (DiaSorin) immunoassay platform. RIs (2.5th and 97.5th percentiles) were established for aldosterone, renin, thyroglobulin, anti-thyroglobulin, and growth hormone. Manufacturer-recommended pediatric RIs for IGF-1 were verified. RESULTS: Age-specific RIs were established for aldosterone, renin, and thyroglobulin, while no age-specific differences were observed for anti-thyroglobulin or growth hormone. IGF-1 was the only endocrine marker studied that demonstrated significant sex-specific differences. Manufacturer-recommended IGF-1 RIs were verified for children aged 6 to <19 years, while those for children aged 0 to <6 years did not verify. CONCLUSIONS: This study marks the first time that pediatric RIs for aldosterone and renin were established in the CALIPER cohort and highlights the dynamic changes that occur in water and sodium homeostasis during the first years of life. Overall, these data will assist pediatric clinical laboratories in test result interpretation and improve clinical decision-making for patients tested using Liaison immunoassays.
Assuntos
Fator de Crescimento Insulin-Like I , Tireoglobulina , Masculino , Feminino , Criança , Humanos , Adolescente , Aldosterona , Renina , Valores de Referência , Imunoensaio , Hormônio do CrescimentoRESUMO
The cobas® EBV and BKV assays are the first FDA-approved, quantitative assays for monitoring posttransplant reactivation of these viruses. In this study, we assessed performance of the fully-automated cobas® assays, compared with Diasorin Molecular ASR, our laboratory developed test, and demonstrated a strong interassay correlation for BK and EBV monitoring.
Assuntos
Vírus BK , Infecções por Vírus Epstein-Barr , Transplante de Células-Tronco Hematopoéticas , Transplante de Rim , Infecções por Polyomavirus , Humanos , Herpesvirus Humano 4/genética , Infecções por Vírus Epstein-Barr/diagnóstico , Vírus BK/genética , Infecções por Polyomavirus/diagnóstico , Carga Viral , DNA Viral , Transplante de Células-Tronco Hematopoéticas/efeitos adversosRESUMO
In this study, we compared the DiaSorin LiaisonXL IGF-1 immunoassay to both the Roche Elecsys IGF-1 immunoassay and to the liquid chromatography-high resolution mass spectrometry (LC-MS) IGF-1 assay. Our study shows a constant positive bias in DiaSorin compared to the Roche immunoassay (mean 42 µg/L, 24%), and a proportional positive bias in DiaSorin compared to the LC-MS method (mean 49 µg/L, 29%). Further, we demonstrate the potential clinical impact of this bias by evaluating 43 adult samples, collected over a 2-month period, which were shown to be discrepant based on a chart review. Despite the positive analytical bias in the Diasorin assay compared to the LC-MS assay, the Diasorin assay upper reference limits were lower than those of the LC-MS assay. This effect caused nine out of forty-three samples to show falsely elevated results when they were clinically diagnosed as negative for acromegaly. Discussed in the context of previous literature, our findings emphasize the importance of adjusting reference intervals for IGF-1 assays based on the clinical needs of a patient population.
Assuntos
Espectrometria de Massas em Tandem , Vitamina D , Adulto , Cromatografia Líquida/métodos , Humanos , Imunoensaio/métodos , Fator de Crescimento Insulin-Like I , Laboratórios Clínicos , Espectrometria de Massas em Tandem/métodosRESUMO
In the summer of 2019, DiaSorin Molecular started designing a multiplex respiratory panel with pan-coronavirus detection as one of the planned targets. The R&D team in Gerenzano, Italy was already searching databases, performing alignments and assessing preliminary target regions for common coronavirus RT-PCR, including SARS and MERS-CoV. In December 2019, we were vigilant and following a cluster of pneumonia cases with undetermined etiology in Wuhan, China. As we now know, the cause of the respiratory infections was the new SARS-CoV-2 virus. DiaSorin Molecular swiftly responded in line with our heritage and company history in detecting emerging infectious diseases. Early in the pandemic and in record time, using research and development teams in both Italy and the U.S. together with the U.S. manufacturing team, we were able to develop and commercialize a new diagnostic test, Simplexa™ COVID-19 Direct, to detect SARS-CoV-2. Our unique platform allowed development of a rapid diagnostic test without the need for extraction reagents. Challenges with control materials, quarantines, clinical samples, raw materials and production were overcome and the entire company worked side by side for accelerated delivery of this assay to clinical labs in Europe, the U.S. and Canada.
Assuntos
COVID-19 , COVID-19/diagnóstico , Teste para COVID-19 , China , Humanos , Pandemias , SARS-CoV-2/genética , Sensibilidade e EspecificidadeRESUMO
Objectives: Procalcitonin (PCT) is an important biomarker of sepsis and respiratory infections. Various automated immunoassays for measuring PCT in patient plasma are available in medical laboratories. However, due to a lack of international reference material for PCT, the assays are not always comparable. Design and methods: In this study, we compared a new turbidimetric immunoassay from DiaSys, measured on the Abbott Architect c16000 and Alinity c, with four BRAHMS-associated chemiluminescence immunoassays (Abbott Architect i2000SR, Alinity i, Roche Cobas e411 and DiaSorin Liaison XL) using 120 random patient plasma samples from the clinical laboratory routine at the University Medical Center Goettingen. Results: The DiaSys assay showed clear differences as compared to the BRAHMS-associated assays when measured on Architect c: i.e. 58% positive mean bias vs. Architect i, 67% vs. Cobas and 23% vs. Liaison. As a result, additional 19% our patients would have a suspected bacterial infection, when using PCT values from the DiaSys assay and commonly accepted decision limits. A crosscheck of the DiaSys calibrator on the BRAHMS-associated systems showed a low recovery of the calibrator material (approx. 50%). Conclusions: Overall, this study shows significant differences between the DiaSys and BRAHMS-associated assays. This could be attributed to a potential DiaSys calibrator problem. This highlights the need for an international reference material for harmonization of the PCT assays.
RESUMO
Serological assays for SARS-CoV-2 infection are now widely available for use in diagnostic laboratories. Limited data are available on the performance characteristics in different settings, and at time periods remote from the initial infection. Validation of the Abbott (Architect SARS-CoV-2 IgG), DiaSorin (Liaison SARS-CoV-2 S1/S2 IgG) and Roche (Cobas Elecsys Anti-SARS-CoV-2) assays was undertaken utilising 217 serum samples from 131 participants up to 7 months following COVID-19 infection. The Abbott and DiaSorin assays were implemented into routine laboratory workflow, with outcomes reported for 2764 clinical specimens. Sensitivity and specificity were concordant with the range reported by the manufacturers for all assays. Sensitivity across the convalescent period was highest for the Roche at 95.2-100% (95% CI 81.0-100%), then the DiaSorin at 88.1-100% (95% CI 76.0-100%), followed by the Abbott 68.2-100% (95% CI 53.4-100%). Sensitivity of the Abbott assay fell from approximately 5 months; on this assay paired serum samples for 45 participants showed a significant drop in the signal-to-cut-off ratio and 10 sero-reversion events. When used in clinical practice, all samples testing positive by both DiaSorin and Abbott assays were confirmed as true positive results. In this low prevalence setting, despite high laboratory specificity, the positive predictive value of a single positive assay was low. Comprehensive validation of serological assays is necessary to determine the optimal assay for each diagnostic setting. In this low prevalence setting we found implementation of two assays with different antibody targets maximised sensitivity and specificity, with confirmatory testing necessary for any sample which was positive in only one assay.
Assuntos
Anticorpos Antivirais/análise , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Anticorpos Antivirais/sangue , Humanos , Laboratórios , Estudos Longitudinais , SARS-CoV-2 , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: The introduction of the vaccination against SARS-CoV-2 infection creates the need for precise tools for the quality control of vaccination procedures, detection of poor humoral response, and estimation of the achieved protection against the disease. Thus, the study aimed to compare the results of the anti-SARS-CoV-2 tests to evaluate the application of the WHO standard unitage (the binding antibody units; BAU/mL) for a measurement of response to the vaccination. METHODS: Patients undergoing vaccination against SARS-CoV-2 with Pfizer/BioNTech BNT162b2 (BNT162b2) (n = 79), referred for SARS-CoV-2 antibody measurement prior to vaccination and 21 days after dose 1, and 8, 14, and 30 days after dose 2 were included. The sera were tested with three assays: Elecsys SARS-CoV-2 S (Roche), LIAISON® SARS-CoV-2 TrimericS IgG (DiaSorin), and SARS-CoV-2 IgG II Quant (Abbott). RESULTS: The three assays showed varying correlations at different time points in the study. The overall agreement for all samples was moderate to high (ρ = 0.663-0.902). We observed the most uniform agreement for the day of dose 2 (ρ = 0.775-0.825), while it was least consistent for day 8 (ρ = -0.131-0.693) and 14 (ρ = -0.247-0.603) after dose 2. The dynamics of changes of the SARS-CoV-2 antibody levels in patients without history of prior SARS-CoV-2 infection appears homogenous based on the Roche results, more heterogenous when considering the DiaSorin results, and in between for the Abbott results. CONCLUSIONS: The results highlight the need for further work on the international standard of measurement of SARS-CoV-2 Ig, especially in the era of vaccination. The serological assays can be useful to detect IgG/IgM antibodies to assess the response to the vaccination. However, they cannot be used interchangeably. In terms of the evaluation of the immune response to the BNT162b2 vaccine, Roche and Abbott kits appear to be more useful.
RESUMO
PURPOSE: To assess the diagnostic performances of five automated anti-SARS-CoV-2 immunoassays, Epitope (N), Diasorin (S1/S2), Euroimmun (S1), Roche N (N), and Roche S (S-RBD), and to provide a testing strategy based on pre-test probability. METHODS: We assessed the receiver operating characteristic (ROC) areas under the curve (AUC) values, along with the sensitivity, specificity, positive predictive values (PPVs), and negative predictive values (NPVs), of each assay using a validation sample set of 172 COVID-19 sera and 185 negative controls against a validated S1-immunofluorescence as a reference method. The three assays displaying the highest AUCs were selected for further serodetection of 2033 sera of a large population-based cohort. RESULTS: In the validation analysis (pre-test probability: 48.1%), Roche N, Roche S and Euroimmun showed the highest discriminant accuracy (AUCs: 0.99, 0.98, and 0.98) with PPVs and NPVs above 96% and 94%, respectively. In the population-based cohort (pre-test probability: 6.2%) these three assays displayed AUCs above 0.97 and PPVs and NPVs above 90.5% and 99.4%, respectively. A sequential strategy using an anti-S assay as screening test and an anti-N as confirmatory assays resulted in a 96.7% PPV and 99.5% NPV, respectively. CONCLUSIONS: Euroimmun and both Roche assays performed equally well in high pre-test probability settings. At a lower prevalence, sequentially combining anti-S and anti-N assays resulted in the optimal trade-off between diagnostic performances and operational considerations.
RESUMO
The aim of this study was to evaluate the performance of the DiaSorin Molecular PJ-CMV multiplex real-time PCR (PJ-CMV PCR) assay (DiaSorin Molecular LLC, USA) in bronchoalveolar lavage (BAL) samples compared to direct immunofluorescence assay (IFA) for the detection of Pneumocystis jirovecii and assess CMV and P. jirovecii co-infection rate in immunosuppressed patients with suspected pneumonia. A total of 125 BAL samples from immunosuppressed patients submitted for PJP-IFA were tested. Surplus samples were saved and further tested by using the PJ-CMV PCR assay. Among the 125 samples, P. jirovecii was detected in 31.2% (39/125) and in 40% (50/125) of the specimens using IFA and PJ-CMV PCR respectively. Eleven of the PJ-CMV PCR positive samples were negative by direct IFA for P. jirovecii. All samples positive by direct IFA were also positive by PJ-CMV PCR. Using the direct IFA as a gold standard, the PJ-CMV PCR sensitivity, specificity, positive predictive value and negative predictive value for detection of P. jirovecii were 100%, 87.2%, 78% and 100%, respectively. However, after reviewing the clinical diagnosis, the specificity and PPV increased to 100%. Of the 50 P. jirovecii samples positive by PJ-CMV PCR, 18 (36%) were also positive for CMV by the PJ-CMV PCR. The co-infection rate was found to be 37.5% (6/16) and 35.2% (12/34) in HIV infected and non-HIV infected patients. This study indicated that the DiaSorin Molecular PJ-CMV multiplex real-time PCR assay has higher sensitivity than direct IFA for detection of P. jirovecii and provides rapid detection of PJ and CMV infection in BAL samples.
Assuntos
Líquido da Lavagem Broncoalveolar , Citomegalovirus/genética , Reação em Cadeia da Polimerase Multiplex/métodos , Pneumocystis carinii/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Lavagem Broncoalveolar , Líquido da Lavagem Broncoalveolar/química , Líquido da Lavagem Broncoalveolar/microbiologia , Líquido da Lavagem Broncoalveolar/virologia , Estudos de Casos e Controles , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/virologia , Diagnóstico Diferencial , Humanos , Hospedeiro Imunocomprometido , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Tipagem Micológica/métodos , Pneumonia/diagnóstico , Pneumonia/microbiologia , Pneumonia/patologia , Pneumonia/virologia , Pneumonia por Pneumocystis/diagnóstico , Pneumonia por Pneumocystis/microbiologia , Sensibilidade e Especificidade , Virologia/métodosRESUMO
Because Zika virus (ZIKV) can cause serious birth defects and is involved in cases of Guillain-Barré syndrome, the ZIKV outbreak in the American continent in 2015 resulted in an enormous need for ZIKV diagnostic tools. We evaluated the LIAISON® XL Zika Capture IgM test on 106 samples from patients, mainly travelers, with a confirmed or probable ZIKV infection. Sensitivity between 0 and 84â¯days after onset of symptoms was 92.5%. Specificity was evaluated on a panel of 56 samples known to cause possible cross-reactions. Cross-reaction with DENV antibodies was limited (10.5%) but false-positive results occurred in samples from patients with malaria, CMV and EBV infections.
Assuntos
Anticorpos Antivirais/sangue , Imunoglobulina M/sangue , Testes Sorológicos/métodos , Infecção por Zika virus/diagnóstico , Zika virus/isolamento & purificação , Automação Laboratorial , Reações Cruzadas , Humanos , Estudos Retrospectivos , Sensibilidade e Especificidade , Zika virus/imunologia , Infecção por Zika virus/sangueRESUMO
OBJECTIVES: We assessed the analytical performance of newly developed Access 25(OH) Vitamin D Total assay with Beckman Coulter Unicel DXI 800 and evaluated the agreement between a reference method liquid chromatography/tandem mass spectrometry (LC-MS/MS) and a chemiluminescence method (LIAISON, DiaSorin). DESIGN AND METHODS: 160 serum samples were included. Deming Regression analysis and Bland-Altman plots were used. The concordance correlation coefficient (CCC) was used to assess the degree of agreement between assays and the reference method. RESULTS: The CV% values of Unicel DXI 800 for within-run, between-run and between-day were lower than 6%. When compared to LC-MS/MS, the Access 25(OH) Vitamin D Total assay demonstrated an R value of 0.9444 (intercept -0.089, slope 0.951), with an average bias of -2.9%, and the LIAISON 25(OH) Vitamin D Total assay an R value of 0.9405 (intercept -0605, slope 0.924), with an average bias of -13.6%. In comparison with the LIAISON 25(OH) Vitamin D Total assay, the Access 25(OH) Vitamin D Total assay demonstrated an R value of 0.9498 (intercept 0.528, slope 1.029), with an average bias of 1.2%. The agreement with the LC-MS/MS method, based on values of the CCC, was moderate for the Unicel DXI 800 and LIAISON method (0.95, 0.94 respectively). CONCLUSIONS: The new, automated Access 25(OH) Vitamin D Total assay showed an acceptable correlation with LC-MS/MS and LIAISON. Both methods moderately achieved to classify the patients according to their vitamin D status. However, we need further standardization of vitamin D assays to enhance the accuracy and comparability.
Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Vitamina D/análogos & derivados , Humanos , Reprodutibilidade dos Testes , Vitamina D/sangueRESUMO
BACKGROUND: Rapid commercial assays, including nucleic acid amplification tests and immunoassays for Clostridium. difficile toxins, have replaced the use of older assays. They are included in a two-step algorithm diagnosis, including first the detection of the glutamate dehydrogenase (GDH) as a screening method and second the detection of toxins as a confirmatory method. Although assays that detect the presence of free toxins in feces are known to lack sensitivity, they are preferable to confirm infection. We evaluated the accuracy of the chemiluminescence-based method detecting C. difficile GDH and free toxins A/B (DiaSorin algorithm) to an enzyme-immunoassay (EIA) for GDH with a molecular toxins test (Meridian algorithm), EIA-GDH and an EIA-toxins A/B algorithm (Alere algorithm) with and without toxigenic culture for confirmation. FINDINGS: A total of 468 diarrhoeal and loose stool samples were included in the study. A positive result was defined by a positive GDH and a positive toxin test. Discordant samples were resolved using an enriched toxigenic culture considered as the reference method. After resolution, the DiaSorin algorithm showed a high sensitivity (86.7 %) compared to that of the Alere algorithm with (60.0 %) and without (50.0 %) confirmation by culture and was as sensitive as the Meridian algorithm (90.0 %), while the specificities were similar: 99.1, 99.5, 99.5 and 98.9 %, respectively. CONCLUSIONS: The DiaSorin algorithm was as sensitive as an algorithm including nucleic acid amplification test for toxins. Chemiluminescence toxin-enhanced signal assay compensates the lack of sensitivity usually observed for EIA tests for toxins.