Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
IDCases ; 23: e01035, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33489756

RESUMO

BACKGROUND: Rapid diagnostic tests (RDT) are routinely used in screening for HIV infection. More complex diagnostic algorithms incorporating fourth-generation screening and confirmatory HIV-1/HIV-2 differentiation immunoassays (IA) may be used to confirm HIV infection. Co-infections and autoimmune diseases may lead to falsely reactive HIV diagnostic test results. CASE PRESENTATION: A Kenyan man with asymptomatic schistosomiasis and low risk factors for HIV infection demonstrated an inconsistent and discordant pattern of reactivity on HIV RDT, repeated reactivity on fourth-generation IA and positive at a single time-point for HIV-1 on the Geenius HIV1/HIV2 confirmatory assay during the course of a prospective cohort study with HIV repeat testing. The individual initiated antiretroviral therapy following HIV diagnosis. However, his bi-annual behavioral questionnaire suggested low-risk factors for infection. Supplementary confirmatory serologic and nucleic acid tests were performed and gave discordant results. The participant was determined to be HIV uninfected using cell-associated HIV-1 DNA/RNA testing and antiretroviral therapy was discontinued. DISCUSSION AND CONCLUSIONS: Sole reliance on diagnostic test results may result in misdiagnosis of HIV infection, social harm and potential antiretroviral induced drug toxicity. Interpretation of HIV test results should incorporate multiple parameters.

2.
Asian J Transfus Sci ; 9(1): 29-30, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25722569

RESUMO

INTRODUCTION: The Procleix Ultrio Plusassay is a new-generation qualitative in vitro nucleic acid amplification test used to screen for human immunodeficiency virus type 1 (HIV-1) RNA, hepatitis C virus (HCV) RNA and hepatitis B virus (HBV) DNA in blood donors. This study was performed to compare the Procleix Ultrio assay with the new-generation Procleix Ultrio Plus Nucleic Acid Test (NAT) assays. MATERIALS AND METHODS: Ten thousand three hundred and two donor samples were run in parallel for ID NAT using the Procleix Ultrio and the Procleix Ultrio Plus assay. Simultaneously, enzyme-linked immunosorbent assay testing was performed on an EVOLIS Walk away System for HIV, HCV, HBsAg and anti-HBc. Reactive samples were confirmed using polymerase chain reaction. RESULTS: In the 10,302 samples tested during the study period, we identified 15 NAT yields, and all these revealed HBV DNA in the discriminatory assays. Eight of these were exclusive yields from the Ultrio Plus assay and the remaining seven cases were determined as HBV NAT yield, both by the Procleix Ultrio as well as the Ultrio Plus assays, i.e. "Combined" yields. No HCV or HIV 1 yields were detected during the study period by either of two assays. CONCLUSION: With an overall yield rate of 1 in 687 and an exclusive yield rate of 1 in 1287, the Procleix Ultrio Plus assay proved to be highly sensitive in detecting occult HBV infections.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA