Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 428
Filtrar
1.
Gastroenterology ; 165(4): 1025-1040, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37380136

RESUMO

BACKGROUND & AIMS: This study aimed to estimate the prevalence of liver steatosis and fibrosis in the general population and populations with potential risk factors in China, so as to inform policies for the screening and management of fatty liver disease and liver fibrosis in general and high-risk populations. METHODS: This cross-sectional, population-based, nationwide study was based on the database of the largest health check-up chain in China. Adults from 30 provinces who underwent a check-up between 2017 and 2022 were included. Steatosis and fibrosis were assessed and graded by transient elastography. Overall and stratified prevalence was estimated among the general population and various subpopulations with demographic, cardiovascular, and chronic liver disease risk factors. A mixed effect regression model was used to examine predictors independently associated with steatosis and fibrosis. RESULTS: In 5,757,335 participants, the prevalence of steatosis, severe steatosis, advanced fibrosis, and cirrhosis was 44.39%, 10.57%, 2.85%, and 0.87%, respectively. Participants who were male, with obesity, diabetes, hypertension, dyslipidemia, metabolic syndrome, or elevated alanine aminotransferase or aspartate aminotransferase had a significantly higher prevalence of all grades of steatosis and fibrosis, and those with fatty liver, decreased albumin or platelet count, and hepatitis B virus infection also had a significantly higher prevalence of fibrosis than their healthy counterparts. Most cardiovascular and chronic liver disease risk factors were independent predictors for steatosis and fibrosis, except for dyslipidemia for fibrosis. CONCLUSIONS: A substantial burden of liver steatosis and fibrosis was found in China. Our study provides evidence for shaping future pathways for screening and risk stratification of liver steatosis and fibrosis in the general population. The findings of this study highlight that fatty liver and liver fibrosis should be included in disease management programs as targets for screening and regular monitoring in high-risk populations, especially in those with diabetes.


Assuntos
Diabetes Mellitus , Dislipidemias , Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Humanos , Adulto , Masculino , Feminino , Prevalência , Estudos Transversais , Cirrose Hepática/diagnóstico , Cirrose Hepática/epidemiologia , Cirrose Hepática/etiologia , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/epidemiologia , China/epidemiologia , Dislipidemias/epidemiologia , Fígado/patologia
2.
J Viral Hepat ; 31(6): 277-292, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38326950

RESUMO

Non-invasive methods have largely replaced biopsy to identify advanced fibrosis in hepatitis C virus (HCV). Guidelines vary regarding testing strategy to balance accuracy, costs and loss to follow-up. Although individual test characteristics are well-described, data comparing the accuracy of using two tests together are limited. We calculated combined test characteristics to determine the utility of combined strategies. This study synthesizes empirical data from fibrosis staging trials and the literature to estimate test characteristics for Fibrosis-4 (FIB4), APRI or a commercial serum panel (FibroSure®), followed by transient elastography (TE) or FibroSure®. We simulated two testing strategies: (1) second test only for those with intermediate first test results (staged approach), and (2) second test for all. We summarized empiric data with multinomial distributions and used this to estimate test characteristics of each strategy on a simulated population of 10,000 individuals with 4.2% cirrhosis prevalence. Negative predictive value (NPV) for cirrhosis from a single test ranged from 98.2% (95% CB 97.6-98.8%) for FIB-4 to 99.4% (95% CB 99.0-99.8%) for TE. Using a staged approach with TE second, sensitivity for cirrhosis rose to 93.3-96.9%, NPV to 99.7-99.8%, while PPV dropped to <32%. Using TE as a second test for all minimally changed estimated test characteristics compared with the staged approach. Combining two non-invasive fibrosis tests barely improves NPV and decreases or does not change PPV compared with a single test, challenging the utility of serial testing modalities. These calculated combined test characteristics can inform best methods to identify advanced fibrosis in various populations.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática , Humanos , Cirrose Hepática/diagnóstico , Cirrose Hepática/patologia , Cirrose Hepática/virologia , Técnicas de Imagem por Elasticidade/métodos , Sensibilidade e Especificidade , Hepatite C Crônica/complicações , Hepatite C Crônica/patologia , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Masculino , Feminino , Hepatite C/diagnóstico , Hepatite C/complicações , Pessoa de Meia-Idade
3.
J Magn Reson Imaging ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38855820

RESUMO

BACKGROUND: Preoperative differentiation of the types of mediastinal tumors is essential. Magnetic resonance (MR) elastography potentially provides a noninvasive method to assess the classification of mediastinal tumor subtypes. PURPOSE: To evaluate the use of MR elastography in anterior mediastinal masses and to characterize the mechanical properties of tumors of different subtypes. STUDY TYPE: Prospective. SUBJECTS: 189 patients with anterior mediastinal tumors (AMTs) confirmed by histopathology (62 thymomas, 53 thymic carcinomas, 57 lymphomas, and 17 germ cell tumors). FIELD STRENGTH/SEQUENCE: A gradient echo-based 2D MR elastography sequence and a diffusion-weighted imaging (DWI) sequence at 3.0 T. ASSESSMENT: Stiffness and apparent diffusion coefficients (ADC) were measured in AMTs using MR elastography-derived elastograms and DWI-derived ADC maps, respectively. The aim of this study is to identify whether MR elastography can differentiate between the histological subtypes of ATMs. STATISTICAL TESTS: One-way analysis of variance (ANOVA), two-way ANOVA, Pearson's linear correlation coefficient (r), receiver operating characteristic (ROC) curve analysis; P < 0.05 was considered significant. RESULTS: Lymphomas had significantly lower stiffness than other AMTs (4.0 ± 0.63 kPa vs. 4.8 ± 1.39 kPa). The mean stiffness of thymic carcinomas was significantly higher than that of other AMTs (5.6 ± 1.41 kPa vs. 4.2 ± 0.94 kPa). Using a cutoff value of 5.0 kPa, ROC analysis showed that lymphomas could be differentiated from other AMTs with an accuracy of 59%, sensitivity of 97%, and specificity of 38%. Using a cutoff value of 5.1 kPa, thymic carcinomas could be differentiated from other AMTs with an accuracy of 84%, sensitivity of 67%, and specificity of 90%. However, there was an overlap in the stiffness values of individual thymomas (4.2 ± 0.71; 3.9-4.5), thymic carcinomas (5.6 ± 1.41; 5.0-6.1), lymphomas (4.0 ± 0.63; 3.8-4.2), and germ cell tumors (4.5 ± 1.79; 3.3-5.6). DATA CONCLUSION: MR elastography-derived stiffness may be used to evaluate AMTs of various histologies. TECHNICAL EFFICACY: Stage 2.

4.
J Magn Reson Imaging ; 59(3): 1070-1073, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37246446

RESUMO

BACKGROUND: Nonalcoholic fatty liver disease (NAFLD) is a leading cause of end-stage liver disease. NAFLD diagnosis and follow-up relies on a combination of clinical data, liver imaging, and/or liver biopsy. However, intersite imaging differences impede diagnostic consistency and reduce the repeatability of the multisite clinical trials necessary to develop effective treatments. PURPOSE/HYPOTHESIS: The goal of this pilot study was to harmonize commercially available 3 T magnetic resonance imaging (MRI) measurements of liver fat and stiffness in human participants across academic sites and MRI vendors. STUDY TYPE: Cohort. SUBJECTS: Four community-dwelling adults with obesity. FIELD STRENGTH/SEQUENCE: 1.5 and 3 T, multiecho 3D imaging, PRESS, and GRE. ASSESSMENT: Harmonized proton density fat fraction (PDFF) and magnetic resonance spectroscopy (MRS) protocols were used to quantify the FF of synthetic phantoms and human participants with obesity using standard acquisition parameters at four sites that had four different 3 T MRI instruments. In addition, a harmonized magnetic resonance elastography (MRE) protocol was used to quantify liver stiffness among participants at two different sites at 1.5 and 3 T field strengths. Data were sent to a single data coordinating site for postprocessing. STATISTICAL TESTS: Linear regression in MATLAB, ICC analyses using SAS 9.4, one-sided 95% confidence intervals for the ICC. RESULTS: PDFF and MRS FF measurements were highly repeatable among sites in both humans and phantoms. MRE measurements of liver stiffness in three individuals at two sites using one 1.5 T and one 3 T instrument showed repeatability that was high although lower than that of MRS and PDFF. CONCLUSIONS: We demonstrated harmonization of PDFF, MRS, and MRE-based quantification of liver fat and stiffness through synthetic phantoms, traveling participants, and standardization of postprocessing analysis. Multisite MRI harmonization could contribute to multisite clinical trials assessing the efficacy of interventions and therapy for NAFLD. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Adulto , Humanos , Hepatopatia Gordurosa não Alcoólica/patologia , Projetos Piloto , Reprodutibilidade dos Testes , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Obesidade/patologia
5.
Muscle Nerve ; 69(6): 682-690, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38517116

RESUMO

INTRODUCTION/AIMS: Carriers of DMD pathogenic variants may become symptomatic and develop muscle-related manifestations. Despite that, few studies have attempted to characterize changes in the muscles of these carriers using imaging tools, particularly muscle ultrasound (MUS). The aim of this study was to compare lower limb MUS findings in carriers of DMD pathogenic variants (cDMD) vs healthy controls. METHODS: Twenty-eight women (15 cDMD and 13 controls) underwent clinical evaluation and MUS. We collected information about muscle-related symptoms and assessed muscle strength. MUS was performed by a single physician (blind to the genetic status of subjects). The following muscles were assessed: rectus femoris, sartorius, tibialis anterior, and medial gastrocnemius. For each site, we computed data on muscle thickness, cross-sectional area, sound attenuation index, and elastography. Between-group comparisons were assessed using nonparametric tests and p-values <.05 were deemed significant. RESULTS: None of the subjects had objective muscle weakness, but exercise intolerance/fatigue was reported by four cDMDs and only one control. Regarding MUS, sound attenuation indices were significantly higher among carriers for all muscles tested. Longitudinal and axial deep echo intensities for the rectus femoris and tibialis anterior were also higher in the cDMD group compared with controls. No significant between-group differences were noted for elastography values, muscle area, or mean echo intensities. DISCUSSION: cDMD have skeletal muscle abnormalities that can be detected using quantitative MUS. Further studies are needed to determine whether such abnormalities are related to muscle symptoms in these patients.


Assuntos
Músculo Esquelético , Distrofia Muscular de Duchenne , Ultrassonografia , Humanos , Feminino , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiopatologia , Adulto , Distrofia Muscular de Duchenne/diagnóstico por imagem , Distrofia Muscular de Duchenne/genética , Distrofia Muscular de Duchenne/fisiopatologia , Adulto Jovem , Pessoa de Meia-Idade , Distrofina/genética , Heterozigoto , Adolescente , Força Muscular/fisiologia
6.
Eur Radiol ; 34(2): 945-956, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37644151

RESUMO

OBJECTIVE: To reduce the number of biopsies performed on benign breast lesions categorized as BI-RADS 4-5, we investigated the diagnostic performance of combined two-dimensional and three-dimensional shear wave elastography (2D + 3D SWE) with standard breast ultrasonography (US) for the BI-RADS assessment of breast lesions. METHODS: A total of 897 breast lesions, categorized as BI-RADS 3-5, were subjected to standard breast US and supplemented by 2D SWE only and 2D + 3D SWE analysis. Based on the malignancy rate of less than 2% for BI-RADS 3, lesions assessed by standard breast US were reclassified with SWE assessment. RESULTS: After standard breast US evaluation, 268 (46.1%) participants underwent benign biopsies in BI-RADS 4-5 lesions. By using separated cutoffs for upstaging BI-RADS 3 at 120 kPa and downstaging BI-RADS 4a at 90 kPa in 2D + 3D SWE reclassification, 123 (21.2%) participants underwent benign biopsy, resulting in a 54.1% reduction (123 versus 268). CONCLUSION: Combining 2D + 3D SWE with standard breast US for reclassification of BI-RADS lesions may achieve a reduction in benign biopsies in BI-RADS 4-5 lesions without sacrificing sensitivity unacceptably. CLINICAL RELEVANCE STATEMENT: Combining 2D + 3D SWE with US effectively reduces benign biopsies in breast lesions with categories 4-5, potentially improving diagnostic accuracy of BI-RADS assessment for patients with breast lesions. TRIAL REGISTRATION: ChiCTR1900026556 KEY POINTS: • Reduce benign biopsy is necessary in breast lesions with BI-RADS 4-5 category. • A reduction of 54.1% on benign biopsies in BI-RADS 4-5 lesions was achieved using 2D + 3D SWE reclassification. • Adding 2D + 3D SWE to standard breast US improved the diagnostic performance of BI-RADS assessment on breast lesions: specificity increased from 54 to 79%, and PPV increased from 54 to 71%, with slight loss in sensitivity (97.2% versus 98.7%) and NPV (98.1% versus 98.7%).


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia Mamária/métodos
7.
Eur Radiol ; 34(3): 1545-1555, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37658892

RESUMO

OBJECTIVE: To systematically evaluate the diagnostic performance of ultrasound elastography (USE) in distinguishing primary Sjögren's syndrome (pSS) from healthy/disease controls. METHODS: We searched the PubMed, Embase, Web of Science, and Cochrane Library databases for published literature on USE for diagnosing pSS. Bivariate random effects models were used to calculate the pooled sensitivity and specificity of USE. To determine the factors influencing heterogeneity, meta-regression and subgroup analyses were performed to assess country, diagnostic criteria, imaging mechanisms, shear wave elastography techniques, measurement location, control group category, and patient age. Publication bias was assessed using the asymmetry of the Deeks funnel plot. RESULTS: Fifteen articles covering 816 patients and 735 control participants were included. USE showed a pooled sensitivity of 0.80 (95% CI: 0.71-0.87) and specificity of 0.87 (95% CI: 0.78-0.92). Meta-regression and subgroup analyses revealed that shear wave elastography techniques, measurement location, and patient age were significant factors that affected study heterogeneity (p < 0.05). Elastography performs better in diagnosing patients aged ≤ 51 years compared to patients aged > 51 years. There was no significant publication bias. CONCLUSION: USE demonstrates high accuracy in differentiating between pSS and healthy/disease control groups. CLINICAL RELEVANCE STATEMENT: Ultrasound elastography, as a non-invasive and cost-effective technique, can be used to distinguish primary Sjögren's syndrome from disease/healthy control groups by measuring the stiffness of salivary glands. KEY POINTS: • Ultrasound elastography is an acceptable technique for the diagnosis of primary Sjögren's syndrome. • The pooled sensitivity and specificity of ultrasound elastography for diagnosing primary Sjögren's syndrome were 0.80 and 0.87, respectively. • In patients aged ≤ 51 years with primary Sjögren's syndrome, ultrasound elastography showed good diagnostic performance.


Assuntos
Técnicas de Imagem por Elasticidade , Síndrome de Sjogren , Humanos , Síndrome de Sjogren/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Glândulas Salivares/diagnóstico por imagem , Sensibilidade e Especificidade , Viés de Publicação
8.
Hepatol Res ; 54(4): 347-357, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37843392

RESUMO

AIMS: Biliary atresia (BA) is a congestive biliary disease that develops in the neonatal period or early infancy. It may present with portal hypertension and varices needing treatment (VNT) even after successful Kasai portoenterostomy. This study aimed to stratify the risk of VNT in children and adolescents with BA. METHODS: In this prospective cross-sectional study, we measured liver stiffness (LS) and spleen stiffness (SS) by two-dimensional shear wave elastography and checked for VNT endoscopically in 53 patients with BA who attended for follow-up between July 2018 and September 2022. Varices needing treatment were defined as large esophageal varices, esophageal varices of any size with red color signs, and/or gastric varices along the cardia. RESULTS: Twenty-five patients (aged 0-18 years) had VNT. Eighteen patients met the Baveno VI criteria (LS <20 kPa; platelet count >150 000/L) and were deemed to be at low risk of VNT (spared endoscopies) while three had missed VNT (16.7%). Applying the Baveno VII criteria, which combines the SS cut-off value of 40 kPa with the Baveno VI criteria, resulted in five missed VNTs among 22 spared endoscopies (22.7%). A modification of the Baveno VII criteria using the aspartate aminotransferase-to-platelet ratio index (APRI) instead of the platelet count with cut-off values of 25 kPa, 30 kPa, and 1.04 for LS, SS, and APRI, respectively, missed only one VNT (5.0%) among 20 spared endoscopies. CONCLUSIONS: A novel diagnostic criterion that combines LS, SS, and APRI reduced the risk of missing VNT to 5% in children and adolescents with BA.

9.
BMC Med Imaging ; 24(1): 229, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39215218

RESUMO

OBJECTIVES: To investigate the value of conventional ultrasonography (US) combined with quantitative shear wave elastography (SWE) in evaluating and identifying target axillary lymph node (TALN) for fine needle aspiration biopsy (FNAB) of patients with early breast cancer. MATERIALS AND METHODS: A total of 222 patients with 223 ALNs were prospectively recruited from January 2018 to December 2021. All TALNs were evaluated by US, SWE and subsequently underwent FNAB. The diagnostic performances of US, SWE, UEor (either US or SWE was positive) and UEand (both US and SWE were positive), and FNAB guided by the above four methods for evaluating ALN status were assessed using receiver operator characteristic curve (ROC) analyses. Univariate and multivariate logistic regression analyses used to determine the independent predictors of axillary burden. RESULTS: The area under the ROC curve (AUC) for diagnosing ALNs using conventional US and SWE were 0.69 and 0.66, respectively, with sensitivities of 78.00% and 65.00% and specificities of 60.98% and 66.67%. The combined method, UEor, demonstrated significantly improved sensitivity of 86.00% (p < 0.001 when compared with US and SWE alone). The AUC of the UEor-guided FNAB [0.85 (95% CI, 0.80-0.90)] was significantly higher than that of US-guided FNAB [0.83 (95% CI, 0.78-0.88), p = 0.042], SWE-guided FNAB [0.79 (95% CI, 0.72-0.84), p = 0.001], and UEand-guided FNAB [0.77 (95% CI, 0.71-0.82), p < 0.001]. Multivariate logistic regression showed that FNAB and number of suspicious ALNs were found independent predictors of axillary burden in patients with early breast cancer. CONCLUSION: The UEor had superior sensitivity compared to US or SWE alone in ALN diagnosis. The UEor-guided FNAB achieved a lower false-negative rate compared to FNAB guided solely by US or SWE, which may be a promising tool for the preoperative diagnosis of ALNs in early breast cancer, and had the potential implication for the selection of axillary surgical modality.


Assuntos
Axila , Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Linfonodos , Humanos , Técnicas de Imagem por Elasticidade/métodos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Axila/diagnóstico por imagem , Pessoa de Meia-Idade , Biópsia por Agulha Fina , Adulto , Idoso , Estudos Prospectivos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Sensibilidade e Especificidade , Curva ROC , Metástase Linfática/diagnóstico por imagem , Biópsia Guiada por Imagem/métodos
10.
Acta Radiol ; 65(9): 1021-1029, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39033394

RESUMO

BACKGROUND: The impact of excluding intrahepatic segmental vessels from regions of interest (ROIs) on liver stiffness measurement (LSM) via magnetic resonance elastography (MRE) remains uncertain. PURPOSE: To determine the effect of excluding intrahepatic segmental vessels from ROIs on LSM obtained from MRE. MATERIAL AND METHODS: This retrospective analysis included 95 participants who underwent successful two-dimensional gradient recalled-echo MRE before hepatic tumor resection (n = 49) or living liver donation (n = 46). The conventional LSM was determined by manually drawing ROIs on the elastogram within the 95% confidence region, staying 1 cm within the liver capsule and excluding large hilar vessels, the gallbladder, hepatic lesions, and artifacts. In addition, the modified LSM was determined by excluding intrahepatic segmental vessels. LSMs obtained by the two methods were compared with paired sample signed-rank test. Diagnostic performance for advanced fibrosis was calculated and compared using McNemar's test and Delong's test. The stage of hepatic fibrosis was assessed using surgical specimens by the METAVIR system. RESULTS: The modified LSM was larger than the conventional LSM (2.4 kPa vs. 2.2 kPa in reader 1; 2.7 kPa vs. 2.4 kPa in reader 2; P < 0.001). The modified LSM showed superior sensitivity (0.841 vs. 0.659 in reader 1; 0.864 vs. 0.705 in reader 2; P < 0.05) and area under the curve (0.901 vs. 0.820 in reader 1; 0.912 vs. 0.843 in reader 2; P < 0.05) for detecting advanced fibrosis (≥F3) than conventional LSM. CONCLUSION: The exclusion of intrahepatic segmental vessels from ROIs in MRE affected the LSM and enhanced diagnostic performance for advanced fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática , Fígado , Humanos , Técnicas de Imagem por Elasticidade/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Cirrose Hepática/diagnóstico por imagem , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Fígado/irrigação sanguínea , Fígado/patologia , Adulto , Idoso , Sensibilidade e Especificidade
11.
Pediatr Radiol ; 54(7): 1144-1155, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38772925

RESUMO

BACKGROUND: Non-invasive imaging modalities are warranted for diagnosing and monitoring veno-occlusive disease because early diagnosis and treatment improve the prognosis. OBJECTIVE: To evaluate the usefulness of liver shear wave elastography (SWE) and shear wave dispersion (SWD) imaging in diagnosing and monitoring veno-occlusive disease in pediatric patients. MATERIALS AND METHODS: We conducted a prospective cohort study at a single tertiary hospital from March 2021 to April 2022. The study protocol included four ultrasound (US) sessions: a baseline US and three follow-up US after hematopoietic stem cell transplantation. Clinical criteria, including the European Society for Blood and Marrow Transplantation criteria, were used to diagnose veno-occlusive disease. We compared clinical factors and US parameters between the veno-occlusive disease and non-veno-occlusive disease groups. The diagnostic performance of US parameters for veno-occlusive disease was assessed by plotting receiver operating characteristic (ROC) curves. We describe temporal changes in US parameters before and after veno-occlusive disease diagnosis. RESULTS: Among the 38 participants (mean age 10.7 years), eight developed veno-occlusive disease occurring 17.0 ± 5.2 days after hematopoietic stem cell transplantation. Liver stiffness, as measured by SWE (15.0 ± 6.2 kPa vs. 5.8 ± 1.8 kPa; P<0.001), and viscosity, as assessed with SWD (17.7 ± 3.1 m/s/kHz vs. 14.3 ± 2.8 m/s/kHz; P=0.015), were significantly higher in the veno-occlusive disease group compared to the non-veno-occlusive disease group at the time of diagnosis. Liver stiffness demonstrated the highest area under the ROC (AUROC) curves at 0.960, with an optimal predictive value of >6.5 kPa, resulting in sensitivity and specificity of 100% and 83.3%, respectively. Viscosity demonstrated an AUROC of 0.783, with an optimal cutoff value of 13.9 m/s/kHz for predicting veno-occlusive disease, with a sensitivity of 100% and specificity of 53.3%, respectively. Liver stiffness increased with disease severity and decreased during post-treatment follow-up. CONCLUSION: SWE may be a promising technique for early diagnosis and severity prediction of veno-occlusive disease. Furthermore, liver viscosity assessed by SWD may serve as an additional marker of veno-occlusive disease.


Assuntos
Técnicas de Imagem por Elasticidade , Estudos de Viabilidade , Transplante de Células-Tronco Hematopoéticas , Hepatopatia Veno-Oclusiva , Humanos , Técnicas de Imagem por Elasticidade/métodos , Hepatopatia Veno-Oclusiva/diagnóstico por imagem , Hepatopatia Veno-Oclusiva/etiologia , Masculino , Feminino , Criança , Estudos Prospectivos , Pré-Escolar , Adolescente , Valor Preditivo dos Testes
12.
Arch Gynecol Obstet ; 310(4): 2023-2033, 2024 10.
Artigo em Inglês | MEDLINE | ID: mdl-39198283

RESUMO

PURPOSE: Conventional vaginal strain ultrasound elastography, not based on shear-wave elastography imaging, can assess the biomechanical properties of the uterine cervix. This assessment may inform the risks of preterm birth and failed induction of labor. However, there is considerable variation in the approaches to strain elastography, including the placement of the region of interest (ROI). Therefore, our aim was to provide recommendations for cervical elastography. METHODS: We conducted a literature review on (1) elastography principles, and (2) the cervical anatomy. Subsequently, we performed elastography scanning using a Voluson™ E10 Expert scanner with the BT18 software of (3) polyacrylamide hydrogel simulators, and (4) pregnant women. RESULTS: Increasing the distance between the ROI and probe led to a decrease in the obtained strain value; a 53% decrease was observed at 17.5 mm. Similarly, an increased angle between the ROI and probe-centerline resulted in a 59% decrease for 40° angle. Interposition of soft tissue (e.g., cervical canal) between the ROI and the probe induced an artifact with values from the posterior lip being 54% lower than those from the anterior lip, even after adjusting for probe-ROI distance. Equipment and the recording conductance significantly influenced the results. CONCLUSION: Our findings inform recommendations for future studies on strain cervical elastography.


Assuntos
Colo do Útero , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Gravidez , Colo do Útero/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/instrumentação , Técnicas de Imagem por Elasticidade/métodos
13.
Sensors (Basel) ; 24(14)2024 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-39065950

RESUMO

Plantar fasciopathy is a very common musculoskeletal complaint that leads to reduced physical activity and undermines the quality of life of patients. It is associated with changes in plantar fascia structure and biomechanics which are most often observed between the tissue's middle portion and the calcaneal insertion. Sonographic measurements of thickness and shear wave (SW) elastography are useful tools for detecting such changes and guide clinical decision making. However, their accuracy can be compromised by variability in the tissue's loading history. This study investigates the effect of loading history on plantar fascia measurements to conclude whether mitigation measures are needed for more accurate diagnosis. The plantar fasciae of 29 healthy participants were imaged at baseline and after different clinically relevant loading scenarios. The average (±standard deviation) SW velocity was 6.5 m/s (±1.5 m/s) and it significantly increased with loading. Indicatively, five minutes walking increased SW velocity by 14% (95% CI: -1.192, -0.298, t(27), p = 0.005). Thickness between the calcaneal insertion and the middle of the plantar fascia did not change with the tissues' loading history. These findings suggest that preconditioning protocols are crucial for accurate SW elastography assessments of plantar fasciae and have wider implications for the diagnosis and management of plantar fasciopathy.


Assuntos
Técnicas de Imagem por Elasticidade , Fáscia , Humanos , Masculino , Feminino , Fáscia/diagnóstico por imagem , Fáscia/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Adulto , Fasciíte Plantar/diagnóstico por imagem , Pé/diagnóstico por imagem , Pé/fisiologia , Fenômenos Biomecânicos/fisiologia , Adulto Jovem , Ultrassonografia/métodos , Caminhada/fisiologia
14.
Sensors (Basel) ; 24(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38257632

RESUMO

Shore hardness (SH) is a cost-effective and easy-to-use method to assess soft tissue biomechanics. Its use for the plantar soft tissue could enhance the clinical management of conditions such as diabetic foot complications, but its validity and reliability remain unclear. Twenty healthy adults were recruited for this study. Validity and reliability were assessed across six different plantar sites. The validity was assessed against shear wave (SW) elastography (the gold standard). SH was measured by two examiners to assess inter-rater reliability. Testing was repeated following a test/retest study design to assess intra-rater reliability. SH was significantly correlated with SW speed measured in the skin or in the microchamber layer of the first metatarsal head (MetHead), third MetHead and rearfoot. Intraclass correlation coefficients and Bland-Altman plots of limits of agreement indicated satisfactory levels of reliability for these sites. No significant correlation between SH and SW elastography was found for the hallux, 5th MetHead or midfoot. Reliability for these sites was also compromised. SH is a valid and reliable measurement for plantar soft tissue biomechanics in the first MetHead, the third MetHead and the rearfoot. Our results do not support the use of SH for the hallux, 5th MetHead or midfoot.


Assuntos
Ossos do Metatarso , Adulto , Humanos , Fenômenos Biomecânicos , Dureza , Reprodutibilidade dos Testes , Pé/diagnóstico por imagem
15.
J Clin Ultrasound ; 52(5): 511-521, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38465504

RESUMO

PURPOSE: To explore the diagnostic value of intralesional and perilesional radiomics based on multimodal ultrasound (US) images in predicting the malignant ACR TIRADS 4 thyroid nodules (TNs). METHODS: A total of 297 cases of TNs in patients who underwent preoperative thyroid grayscale US and shear wave elastography (STE) were enrolled (training cohort: n = 150, internal validation cohort: n = 77, external validation cohort: n = 70). Regions of interests (ROIs) were delineated on grayscale US images and STE images, and then an isotropic expansion of 1.0, 1.5, 2.0, 2.5, and 3.0 mm was applied. Predictive models were established using recursive feature elimination-support vector machines (RFE-SVM) based on radiomics features calculated by random forest. RESULTS: The perilesional ROI1.5mm expansion achieved the highest area under curve (AUC) (AUC: 0.753 for grayscale US, 0.728 for STE; 95% confidence interval (CI): 0.664-0.743, 0.684-0.739, respectively). The joint model had the highest AUC values of 0.936 in the training dataset, 0.926 in internal dataset, and 0.893 in external dataset. The calibration curve showed good consistency and the decision curve indicated a greater clinical net benefit of the joint model. CONCLUSION: Joint model containing perilesional radiomics (1.5 mm) had significant value in predicting the malignant ACR TIRADS 4 TNs.


Assuntos
Nódulo da Glândula Tireoide , Ultrassonografia , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Ultrassonografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Glândula Tireoide/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Retrospectivos , Imagem Multimodal/métodos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Idoso , Reprodutibilidade dos Testes , Radiômica
16.
J Clin Ultrasound ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38708803

RESUMO

We explore the use of shear wave elastography (SWE) for assessing muscle stiffness and treatment response in cerebral palsy (CP) children by way of a systematic review. SWE offers real-time muscle stiffness measurements, showing significant differences between CP patients and controls. Studies suggest that SWE can be used to follow muscle stiffness post-botulinum toxin treatment, correlating with clinical improvement. However, methodological variations and small sample sizes prevent comparison between different studies. Standardized protocols could enhance SWE's clinical utility. In conclusion, SWE holds promise for CP management, though standardized methodologies and larger studies are needed to validate its efficacy and integration into clinical practice.

17.
J Magn Reson Imaging ; 57(5): 1414-1422, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36305562

RESUMO

BACKGROUND: Quantifying the rotator cuff (RC) muscles' viscoelasticity could provide outcome relevant information in patients with RC tears. MR-elastography requires robust diffusion-tensor imaging (DTI) to account for tissue anisotropy in muscles stiffness computation. PURPOSE: To assess the repeatability of DTI parameters in the supraspinatus and infraspinatus muscles and to explore DTI tractography conformity with the muscles' anatomy. STUDY TYPE: Prospective. SUBJECTS: Six healthy volunteers underwent three consecutive shoulder MRI sessions about 10 minutes apart. FIELD STRENGTH/SEQUENCE: 3T/T1-vibe Dixon and Spin echo EPI DTI (12 gradient encoding directions, b-values 500 and 800 sec/mm2 ). ASSESSMENT: Supraspinatus and infraspinatus muscles were segmented on the T1-vibe Dixon sequence. DTI image quality was assessed using a quantitative threshold based on the signal-to-noise ratio (SNR). The eigenvalues ( λ 1 , λ 2 , λ 3 ), fractional anisotropy (FA) and mean diffusivity were calculated. DTI tractography was visually assessed. STATISTICAL TESTS: DTI parameters within-subject intersession repeatability was assessed with Bland-Altman analysis and the coefficient of variation (CV). Repeatability was considered good for CV < 10%. RESULTS: The SNR between diffusion-weighted and non-diffusion-weighted images was greater than 3, which aligns with standards for estimating DTI parameters. The FA showed the lowest mean bias (-0.007; 95% confidence interval [CI] -0.031 to 0.018) whereas the λ1 had the highest mean bias (0.146 × 10-3  mm2 /sec; CI -0.034 to 0.326 × 10-3  mm2 /sec). CVs of the DTI parameters varied between 3.5% (FA) and 8.4% (λ3 ) for the supraspinatus and between 3.2% (λ1 ) and 6.8% (λ3 ) for the infraspinatus. Tractography provided muscle fiber representations in three-dimensional space concordant with RC anatomy. DATA CONCLUSION: DTI of the supraspinatus and infraspinatus muscles achieved an adequate SNR, allowing the measurement of the DTI metrics with good repeatability, and thus can be used for optimizing stiffness estimation in these anisotropic tissues. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Imagem de Tensor de Difusão , Manguito Rotador , Humanos , Estudos Prospectivos , Imagem de Tensor de Difusão/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Voluntários Saudáveis
18.
Liver Int ; 43(1): 90-99, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050821

RESUMO

BACKGROUND AND AIMS: Progressive liver fibrosis related to non-alcoholic fatty liver disease (NAFLD) is associated with all-cause and liver-related mortality. We assessed vibration-controlled transient elastography (VCTE) as a predictor of mortality. METHOD: Data from patients who underwent VCTE for NAFLD at four large health services in Victoria, Australia between the years 2008 and 2019 were linked to state-wide data registries. Cause of death (COD) and predictors of all-cause mortality were subsequently analysed using descriptive statistics and Cox-proportional regression analysis. RESULTS: Of 7079 VCTE records submitted for data linkage, 6341 were matched via data registry linkage. There were 217 deaths over a 22 653 person-year follow-up. COD included malignancies other than hepatocellular carcinoma (HCC) (18.0%, n = 39), sepsis (16.1%, n = 35), decompensated liver disease (15.2%, n = 33), cardiac disease (15.2%, n = 33) and HCC 6.0% (n = 13). Controlled attenuation parameter (CAP) was not associated with mortality in univariable analysis (HR = 1.00, CI 1.0-1.0, p = .488). Increased liver stiffness measurement (LSM) (HR 1.02 per kiloPascal, CI 1.01-1.03, p < .001), Charlson comorbidity index (CCI) (HR 1.32 for each point, CI 1.27-1.38, p < .001) and age (HR 1.05 per annum, CI 1.03-1.07, p < .001) were each associated with higher rates of all-cause mortality in multivariable analysis. LSM ≥10 kPa suggestive of compensated advanced chronic liver disease (cACLD) was associated with mortality in multivariable analysis (HR 2.31, CI 1.73-3.09, p < .001). CONCLUSION: VCTE LSM, in addition to age and CCI, is independently associated with increased all-cause mortality in a large cohort with NAFLD.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Cirrose Hepática/complicações , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Fígado/patologia
19.
Eur Radiol ; 33(6): 4103-4114, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36435877

RESUMO

OBJECTIVES: To evaluate the potential diagnostic value of MR elastography (MRE)-based stiffness to noninvasively predict the microvascular invasion (MVI) grade in hepatocellular carcinoma (HCC). METHODS: One hundred eighty-five patients with histopathology-proven HCC who underwent MRI and MRE examinations before hepatectomy were retrospectively enrolled. According to the three-tiered MVI grading system, the MVI was divided into negative-MVI (n = 89) and positive-MVI (n = 96) groups, and the latter group was categorized into mild-MVI (n = 49) and severe-MVI (n = 47) subgroups. Logistic regression and area under the receiver operating characteristic curve (AUC) analyses were used to determine the predictors associated with MVI grade and analyze their performances, respectively. RESULTS: Among the 185 patients, tumor size ≥ 50 mm (p = 0.031), tumor stiffness (TS)/liver stiffness (LS) > 1.47 (p = 0.001), TS > 4.33 kPa (p < 0.001), and nonsmooth tumor margin (p = 0.006) were significant independent predictors for positive-MVI. Further analyzing the subgroups, tumor size ≥ 50 mm (p < 0.001), TS > 5.35 kPa (p = 0.001), and AFP level > 400 ng/mL (p = 0.044) were independently associated with severe-MVI. The models incorporating MRE and clinical-radiological features together performed better for evaluating positive-MVI (AUC: 0.846) and severe-MVI (AUC: 0.802) than the models using clinical-radiological predictors alone (AUC: positive-/severe-MVI, 0.737/0.743). Analysis of recurrence-free survival and overall survival showed the predicted positive-MVI/severe-MVI groups based on combined models had significantly poorer prognoses than predicted negative-MVI/mild-MVI groups, respectively (all p < 0.05). CONCLUSIONS: MRE-based stiffness was an independent predictor for both the positive-MVI and severe-MVI. The combination of MRE and clinical-radiological models might be a useful tool for evaluating HCC patients' prognoses underwent hepatectomy by preoperatively predicting the MVI grade. KEY POINTS: • The severe-microvascular invasion (MVI) grade had the highest tumor stiffness (TS), followed by mild-MVI and non-MVI, and there were significances among the three different MVI grades. • MR elastography (MRE)-based stiffness value was an independent predictor of positive-MVI and severe-MVI in hepatocellular carcinoma (HCC) preoperatively. • When combined with clinical-radiological models, MRE could significantly improve the predictive performance for MVI grade. Patients with predicted positive-MVI/severe-MVI based on the combined models had worse recurrence-free survival and overall survival than those with negative-MVI/mild-MVI, respectively.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Invasividade Neoplásica/patologia , Imageamento por Ressonância Magnética
20.
Eur Radiol ; 33(8): 5625-5633, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36847836

RESUMO

OBJECTIVES: The purpose of this study was to investigate the effects of tissue fibrosis and microvessel density on shear wave-based ultrasound elastography (SWUE) of chronic kidney disease (CKD). In addition, we were looking to see whether SWUE could predict stage of CKD, correlating with the histology on kidney biopsy. METHODS: Renal tissue sections from 54 patients diagnosed with suspected CKD were subjected to immunohistochemistry (CD31 and CD34), and the degree of tissue fibrosis was assessed using Masson staining. Before renal puncture, both kidneys were examined using SWUE. Comparative analysis was used to assess the correlation between SWUE and microvessel density, and between SWUE and the degree of fibrosis. RESULTS: Fibrosis area according to Masson staining (p < 0.05) and integrated optical density (IOD) (p < 0.05) were positively correlated with CKD stage. The percentage of positive area (PPA) and IOD for CD31 and CD34 were not correlated with CKD stage (p > 0.05). When stage 1 CKD was removed, PPA and IOD for CD34 were negatively correlated with CKD stage (p < 0.05). Masson staining fibrosis area and IOD were not correlated with SWUE (p > 0.05), PPA and IOD for CD31 and CD34 were not correlated with SWUE (p > 0.05) and, finally, no correlation between SWUE and CKD stage was found (p > 0.05). CONCLUSION: The diagnostic value of SWUE for CKD staging was very low. The utility of SWUE in CKD was affected by many factors and its diagnostic value was limited. KEY POINTS: • There was no correlation between SWUE and the degree of fibrosis, or between SWUE and microvessel density among patients with CKD. • There was no correlation between SWUE and CKD stage and the diagnostic value of SWUE for CKD staging was very low. • The utility of SWUE in CKD is affected by many factors and its value was limited.


Assuntos
Técnicas de Imagem por Elasticidade , Insuficiência Renal Crônica , Humanos , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/patologia , Rim/diagnóstico por imagem , Rim/patologia , Ultrassonografia , Fibrose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA