Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 566
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38989565

RESUMO

BACKGROUND: Physician modified endografts (PMEGs) have been widely used in the treatment of complex abdominal aortic aneurysm and thoracoabdominal aortic aneurysm, however, previous data are limited to small single center studies and robust data on safety and effectiveness of PMEGs are lacking. We aimed to perform an international multicenter study analyzing the outcomes of PMEGs in complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. METHODS: An international multicenter single-arm cohort study was performed analyzing the outcomes of PMEGs in the treatment of elective, symptomatic, and ruptured complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. Variables and outcomes were defined according to the Society for Vascular Surgery reporting standards. Device modification and procedure details were collected and analyzed. Efficacy outcomes included technical success and safety outcomes included major adverse events and 30-day mortality. Follow-up outcomes included reinterventions, endoleaks, target vessel patency rates and overall and aortic-related mortality. Multivariable analysis was performed aiming at identifying predictors of technical success, 30-day mortality, and major adverse events. RESULTS: Overall, 1274 patients were included in the study from 19 centers. Median age was 74 (IQR, 68-79), and 75.7% were men; 45.7% were complex abdominal aortic aneurysms, and 54.3% were thoracoabdominal aortic aneurysms; 65.5% patients presented electively, 24.6% were symptomatic, and 9.9% were ruptured. Most patients (83.1%) were submitted to a fenestrated repair, 3.6% to branched repair, and 13.4% to a combined fenestrated and branched repair. Most patients (85.8%) had ≥3 target vessels included. The overall technical success was 94% (94% in elective, 93.4% in symptomatic, and 95.1% in ruptured cases). Thirty-day mortality was 5.8% (4.1% in elective, 7.6% in symptomatic, and 12.7% in ruptured aneurysms). Major adverse events occurred in 25.2% of cases (23.1% in elective, 27.8% in symptomatic, and 30.3% in ruptured aneurysms). Median follow-up was 21 months (5.6-50.6). Freedom from reintervention was 73.8%, 61.8%, and 51.4% at 1, 3, and 5 years; primary target vessel patency was 96.9%, 93.6%, and 90.3%. Overall survival and freedom from aortic-related mortality was 82.4%/92.9%, 69.9%/91.6%, and 55.0%/89.1% at 1, 3, and 5 years. CONCLUSIONS: PMEGs were a safe and effective treatment option for elective, symptomatic, and ruptured complex aortic aneurysms. Long-term data and future prospective studies are needed for more robust and detailed analysis.

2.
J Vasc Surg ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38677660

RESUMO

OBJECTIVE: The aim of this study was to demonstrate the safety and effectiveness of a low-profile thoracic endograft (19-23 French) in subjects with blunt traumatic aortic injury. METHODS: A prospective, multicenter study assessed the RelayPro thoracic endograft for the treatment of traumatic aortic injury. Fifty patients were enrolled at 16 centers in the United States between 2017 and 2021. The primary endpoint was 30-day all-cause mortality. RESULTS: The cohort was mostly male (74%), with a mean age of 42.4 ± 17.2 years, and treated for traumatic injuries (4% Grade 1, 8% Grade 2, 76% Grade 3, and 12% Grade 4) due to motor vehicle collision (80%). The proximal landing zone was proximal to the left subclavian artery in 42%, and access was primarily percutaneous (80%). Most (71%) were treated with a non-bare stent endograft. Technical success was 98% (one early type Ia endoleak). All-cause 30-day mortality was 2% (compared with an expected rate of 8%), with an exact two-sided 95% confidence interval [CI] of 0.1%, 10.6% below the performance goal upper limit of 25%. Kaplan-Meier analysis estimated freedom from all-cause mortality to be 98% at 30 days through 4 years (95% CI, 86.6%-99.7%). Kaplan-Meier estimated freedom from major adverse events, all-cause mortality, paralysis, and stroke, was 98.0% at 30 days and 95.8% from 6 months to 4 years (95% CI, 84.3%-98.9%). There were no strokes and one case of paraplegia (2%) during follow-up. CONCLUSIONS: RelayPro was safe and effective and may provide an early survival benefit in the treatment of blunt traumatic aortic injury.

3.
J Vasc Surg ; 80(2): 554-563.e4, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38608967

RESUMO

OBJECTIVE: Vascular graft and endograft infections (VGEIs) are complicated by high morbidity, mortality, and recurrence rates, notably due to biofilm formation on the graft surface, hardly dislodgeable by the sole anti-infectious treatment. The characteristics of this biofilm are still poorly documented. The aim of this study was to evaluate ex vivo biofilm on removed infected vascular grafts and endografts (VGEs). METHODS: Explanted VGEs were prospectively collected from 2019 to 2022 at Bordeaux University Hospital, France. Two samples per graft were used for scanning electron microscopy imaging; one was sonicated, and both grafts' sides were imaged. RESULTS: A total of 26 patients were included, 18 with VGEI, eight without any infection (endoleak and/or thrombosis), and 29 VGEs were collected. Microbial documentation was obtained in 83% of VGEIs. A thick layer of fibrin was visible on almost all grafts, mixed with a dense biofilm matrix on infected grafts visible as early as 1 month after the onset of infection. Bacteria were not always visualized on infected grafts' surface (80% on outer side and 85% on luminal side) but were surprisingly present on one-third of non-infected grafts. There was no significant difference between biofilm, fibrin, and microorganisms' distribution between the two grafts' sides. However, there were clear differences between infected and non-infected grafts, since immune cells, bacteria and biofilm were more frequently visualized on both sides of infected grafts (P < .05). Bacteria and immune cells although still visible, were significantly less present after sonication; the number of other elements including biofilm was not significantly different. CONCLUSIONS: The persistence of a thick layer of fibrin and biofilm embedding microorganisms on both sides of infected VGE even after 1 month of infection could be the explanation for the low success rates of conservative management and the usual need for graft removal to treat VGEIs.


Assuntos
Biofilmes , Implante de Prótese Vascular , Prótese Vascular , Microscopia Eletrônica de Varredura , Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/cirurgia , Prótese Vascular/efeitos adversos , Biofilmes/crescimento & desenvolvimento , Feminino , Masculino , Idoso , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Estudos Prospectivos , Pessoa de Meia-Idade , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Remoção de Dispositivo , França , Fatores de Tempo , Idoso de 80 Anos ou mais , Bactérias/isolamento & purificação
4.
J Vasc Surg ; 79(6): 1276-1284, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38354829

RESUMO

INTRODUCTION: Custom-branched/fenestrated grafts are widely available in other countries, but in the United States, they are limited to a handful of centers, with the exception of a 3-vessel juxtarenal device (ZFEN). Consequently, many surgeons have turned to alternative strategies such as physician-modified endografts (PMEGs). We therefore sought to determine how widespread the use of these grafts is. METHODS: We studied all complex endovascular repairs of complex and thoracoabdominal aortic aneurysms in the Vascular Quality Initiative from 2014 to 2022 to examine temporal trends. RESULTS: A total of 5826 repairs were performed during the study period: 1895 ZFEN, 3241 PMEG, 595 parallel grafting, and 95 where parallel grafting was used in addition to ZFEN, with a mean of 2.7 ± 0.98 vessels incorporated. Over time, the number of PMEGs steadily increased, both overall and for juxtarenal aneurysms, whereas the number of ZFENs essentially leveled off by 2017 and has remained steady ever since. In the most recent complete year (2021), PMEGs outnumbered ZFENs by over 2:1 overall (567 to 256) and nearly twofold for juxtarenal repairs. In three-vessel cases involving juxtarenal aneurysms, PMEGs were used as frequently as ZFENs (43% vs 43%), whereas the proportion of juxtarenal aneurysms repaired using a four-vessel graft configuration increased from 20% in 2014 to 29% in 2021 (P < .001). The differences in PMEG use were more pronounced as surgeon volume increased. Surgeons in the lowest quartile of volume performed <2 complex repairs annually, evenly split between PMEGs and ZFENs. However, surgeons in the highest quartile of volume performed a median of 18 (interquartile range: 10-21) PMEGs/y, but only 1.6 (interquartile range: 0.8-3.4) ZFENs/y. The number of physician-sponsored investigational device exemption trials of PMEGs has expanded from 1 in 2012 to 8 currently enrolling. As those data are not included in the Vascular Quality Initiative, the true number of PMEGs is likely substantially higher. CONCLUSIONS: PMEGs have become the dominant endovascular repair modality of complex abdominal and thoracoabdominal aortic aneurysms outside of investigational device exemptions. The field of endovascular aortic surgery and patients with complex aneurysms would benefit from broader publication of PMEG techniques, outcomes, and comparisons to custom-manufactured grafts.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Desenho de Prótese , Humanos , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular/tendências , Procedimentos Endovasculares/tendências , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Implante de Prótese Vascular/tendências , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Estados Unidos , Fatores de Tempo , Resultado do Tratamento , Padrões de Prática Médica/tendências , Masculino , Estudos Retrospectivos , Feminino , Idoso , Bases de Dados Factuais , Sistema de Registros , Aneurisma da Aorta Toracoabdominal
5.
J Vasc Surg ; 79(6): 1295-1304.e2, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38280685

RESUMO

OBJECTIVE: Persistent type II endoleaks (pEL2s) are not uncommon after endovascular aneurysm repair and their impact on long-term outcomes is well-documented. However, their occurrence and natural history after fenestrated/branched endografting (F/B-EVAR) for juxtarenal and pararenal aneurysms (J/P-AAAs) have been scarcely investigated. Aim of this study was to report incidence, risk factors, and natural history of pEL2 after F/B-EVAR in J/P-AAAs. METHODS: Between 2016 and 2022, all J/P-AAAs undergoing F/B-EVAR were prospectively collected and retrospectively analyzed. EL2 were assessed at the completion angiography, at 30 days and after 6 months as primary outcomes. Preoperative risk factors for pEL2, follow-up survival, freedom from reinterventions (FFR) and aneurysm shrinkage (≥5 mm) were considered as secondary outcomes. RESULTS: Of 132 patients, there were 88 (67%) JAAAs and 44 (33%) PAAAs. Seventeen EL2 (13%) were detected at the completion angiography and 36 (27%) at 30-day computed tomography angiography. The mean follow-up was 28 ± 23 months. Eleven (31%) EL2 sealed spontaneously within 6 months and three new cases were detected, for an overall of 28 pEL2/107 patients (26%) with available radiological follow-up of ≥6 months. Preoperative antiplatelet therapy (odds ratio, 4.7; 95% confidence interval [CI[, 1-22.1; P = .05), aneurysm thrombus volume of ≤40% and six or more patent aneurysm afferent vessels (odds ratio, 7.2; 95% CI, 1.8-29.1; P = .005) were independent risk factors for pEL2. The estimated 3-year survival was 80%, with no difference between cases with and without pEL2 (78% vs 85%; P = .08). The estimated 3-year FFR was 86%, with no difference between cases with and without pEL2 (81% vs 87%; P = .41). Four cases (3%) of EL2-related reinterventions were performed. In 65 cases (49%), aneurysm shrinkage was detected. pEL2 was an independent risk factor for absence of aneurysm shrinkage during follow-up (hazard ratio, 3.2; 95% CI, 1.2-8.3; P = .014). Patients without shrinkage had lower follow-up survival (64% vs 86% at 3-year; P = .009) and FFR (74% vs 90% at 3 years; P = .014) than patients with shrinkage. CONCLUSIONS: PEL2 is not infrequent (26%) after F/B-EVAR for J/P-AAAs and is correlated with preoperative antiplatelet therapy, aneurysm thrombus volume of ≤40%, and six or more patent sac afferent vessels. Patients with pEL2 have a diminished aneurysm shrinkage, which is correlated with lower follow-up survival and FFR compared with patients with aneurysm shrinkage.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Endoleak , Procedimentos Endovasculares , Humanos , Masculino , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Estudos Retrospectivos , Feminino , Fatores de Risco , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Idoso , Endoleak/etiologia , Endoleak/terapia , Endoleak/diagnóstico por imagem , Fatores de Tempo , Idoso de 80 Anos ou mais , Incidência , Medição de Risco , Resultado do Tratamento , Desenho de Prótese , Stents
6.
J Vasc Surg ; 79(5): 1090-1100.e4, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38185214

RESUMO

OBJECTIVE: To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after endograft placement (aortic flow volume minus the endograft volume). SMP devices self-expand in the sac to form a porous scaffold that supports thrombosis throughout its structure. METHODS: Two identical prospective, multicenter, single-arm studies were conducted in New Zealand and the Netherlands. The study population was adult candidates for elective EVAR of an infrarenal AAA (diameter of ≥55 mm in men and ≥50 mm in women). Key exclusion criteria were an inability to adequately seal a common iliac artery aneurysm, patent sac feeding vessels of >4 mm, and a target lumen volume of <20 mL or >135 mL. Target lumen volumes were estimated by subtracting endograft volumes from preprocedural imaging-based flow lumen volumes. SMP devices were delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. The primary efficacy end point was technical success, defined as filling the actual target lumen volume with fully expanded SMP at the completion of the procedure. Secondary efficacy outcome measures during follow-up were the change in sac volume and diameter, rate of type II endoleak and type I or III endoleaks, and the rate of open repair and related reinterventions, with data collection at 30 days, 6 months, and 1 year (to date). Baseline sac volumes and diameters for change in sac size analyses were determined from 30-day imaging studies. Baseline and follow-up volumes were normalized by subtraction of the endograft volume. RESULTS: Of 34 patients treated with SMP devices and followed per protocol, 33 patients were evaluable at 1 year. Preprocedural aneurysm volume was 181.4 mL (95% confidence interval [CI], 150.7-212.1 mL) and preprocedural aneurysm diameter was 60.8 mm (95% CI, 57.8-63.9 mm). The target lumen volume was 56.3 mL (95% CI, 46.9-65.8 mL). Technical success was 100% and the ratio of SMP fully expanded volume to estimated target lumen volume was 1.4 ± 0.3. Baseline normalized sac volume and diameter were 140.7 mL (95% CI, 126.6-154.9 mL) and 61.0 mm (95% CI, 59.7-62.3 mm). The adjusted mean percentage change in normalized volume at 1 year was -28.8% (95% CI, -35.3 to -22.3%; P < .001). The adjusted mean change in sac diameter at 1 year was -5.9 mm (95% CI, -7.5 to -4.4 mm; P < .001). At 1 year, 81.8% of patients (95% CI, 64.5%-93.0%) achieved a ≥10% decrease in normalized volume and 57.6% of patients (95% CI, 39.2%-74.5%) achieved a ≥5 mm decrease in diameter. No device- or study procedure-related major adverse events occurred through 1 year after the procedure. CONCLUSIONS: Treatment of AAA sacs with SMP devices during EVAR resulted in significant sac volume and diameter regression at 1 year with an acceptable safety profile in this prospective study.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Feminino , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Estudos Prospectivos , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Seguimentos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Fatores de Risco
7.
J Vasc Surg ; 79(5): 1101-1109, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38103807

RESUMO

OBJECTIVE: To evaluate outcomes and performance of inverted limbs (ILs) when used in conjunction with Zenith fenestrated stent grafts (Zfens) to treat patients with short distance between the lowest renal artery (RA) and aortic or graft bifurcation (A/GB). METHODS: This study was a multicenter, retrospective review of prospectively maintained database of patients with complex aortic aneurysms, failed endovascular aneurysm repair (EVAR), or open surgical repair (OSR) with short distance between LRA and A/GB treated using a combination of Zfen and an IL between 2013 and 2023. Endpoints included technical success, aneurysm sac regression, long-term device integrity, and target vessel patency. We defined technical success as implantation of the device with no endoleak, conversion to an aorto-uni-iliac or OSR. RESULTS: During this time, 52 patients underwent endovascular rescue of failed repair. Twenty (38.5%) of them required relining of the failed repairs using IL due to lowest RA to A/GB length restrictions. Two patients had undergone rescue with a fenestrated cuff alone but developed type III endoleaks. One patient with no previous implant had a short distance between the lowest RA and aortic bifurcation to accommodate the bifurcated distal device, and two patients had failed OSR or anastomotic pseudoaneurysms. The majority (94%) were men with a mean age of 76.8 ± 6.1 years. The mean aortic neck diameter and aneurysm size were 32 ± 4 cm and 7.2 ± 1.3 cm, respectively. The median time laps between initial repair and failure was 36 months (interquartile range [IQR], 24-54 months). Sixteen patients (80%) were classified as American Society of Anesthesiologists class III, whereas four were class IV. Seventy-eight vessels were targeted and successfully incorporated. Technical success was 100%, and median estimated blood loss was 100 mL (IQR, 100-200 mL). Mean fluoroscopy time and dose were 61 ± 18 minutes and 2754 ± 1062 mGy, respectively. Average hospital length of stay was 2.75 ± 2.15 days. Postoperative complication occurred in one patient who required lower extremity fasciotomy for compartment syndrome. At a median follow-up of 50 months (IQR, 18-58 months), there were no device migration, components separation, aneurysmal related mortality, and type I or type III endoleak. Aneurysm sac regression (95%) or stabilization (5%) was observed in all patients, including in four patients (25%) with type II endoleak. CONCLUSIONS: The use of IL in conjunction with Zfen to treat patients with short distance between the lowest RA and A/GB is safe, effective, and has excellent long-term results. The technique expands the indication of Zfen, especially in patients with failed previous EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Médicos , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Stents , Endoleak/etiologia , Endoleak/cirurgia , Fatores de Risco , Resultado do Tratamento , Desenho de Prótese , Estudos Retrospectivos
8.
J Vasc Surg ; 79(3): 506-513.e1, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37923022

RESUMO

INTRODUCTION: Frailty, a predictor of poor outcomes, has been widely studied as a screening tool in surgical decision-making. However, the impact of frailty on the outcomes after fenestrated-branched endovascular aortic repairs (FBEVARs) is less well established. In addition, the changes in frailty during recovery after FBEVAR are unknown. We aim to assess the impact of frailty on outcomes of high-risk patients undergoing physician-modified FBEVARs for complex abdominal and thoracoabdominal aortic aneurysms, as well as the changes in frailty during follow-up. METHODS: Consecutive patients enrolled in a single-center prospective Physician-Sponsored Investigational Device Exemption protocol (FDA# G200159) were evaluated. In addition to the baseline characteristics, frailty was assessed using the Hopkins Frailty Score (HFS) and frailty index (FI) measured by the Frailty Meter. Sarcopenia was measured by L3 total psoas muscle area (PMA). These measurements were repeated during follow-up. The follow-up HFS and FI were compared with baseline scores using the Wilcoxon signed-rank test, whereas follow-up PMA measurements were compared with the baseline using the paired t test. The association between baseline frailty and morbidity was evaluated by the Wilcoxon rank-sum test. RESULTS: Seventy patients were analyzed in a prospective Physician-Sponsored Investigational Device Exemption study from February 9, 2021, to June 2, 2023. At baseline, HFS identified 54% of patients as not frail, 43% as intermediately frail, and 3% as frail. Technical success of FBEVAR was 94% with one in-hospital mortality. Early major adverse events were seen in 10 (14.3%) patients. No difference in baseline FI was seen between patients with early morbidity and those without. Patients who were not frail per HFS were less likely to experience early morbidity (P = .033), and there was a significantly lower baseline PMA in patients who experienced early morbidity (P = .016). At 1 month, patients experienced a significant increase in HFS and HFS category (P = .001 and P = .01) and a significant decrease in sarcopenia (mean PMA: -96 mm2, P = .005). At 6 months, HFS and HFS category as well as PMA returned toward baseline (P = .42, P = .38, and mean PMA: +4 mm2, P = .6). CONCLUSIONS: Preoperative frailty and sarcopenia were associated with early morbidity after physician-modified FBEVAR. During follow-up, patients became more frail and sarcopenic by 1 month. Recovery from this initial decline was seen by 6 months, suggesting that frailty and sarcopenia are reversible processes rather than a unidirectional phenomenon of continued decline.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Fragilidade , Sarcopenia , Humanos , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Resultado do Tratamento , Fragilidade/complicações , Fragilidade/diagnóstico , Estudos Prospectivos , Sarcopenia/complicações , Sarcopenia/diagnóstico por imagem , Fatores de Risco , Complicações Pós-Operatórias
9.
J Surg Res ; 299: 17-25, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38688237

RESUMO

INTRODUCTION: Physician-modified endografts (PMEGs) have been used for repair of thoracoabdominal aortic aneurysms (TAAAs) for 2 decades with good outcomes but limited financial data. This study compared the financial and clinical outcomes of PMEGs to the Cook Zenith-Fenestrated (ZFEN) graft and open surgical repair (OSR). METHODS: A retrospective review of financial and clinical data was performed for all patients who underwent endovascular or OSR of juxtarenal aortic aneurysms and TAAAs from January 2018 to December 2022 at an academic medical center. Clinical presentation, demographics, operative details, and outcomes were reviewed. Financial data was obtained through the institution's finance department. The primary end point was contribution margin (CM). RESULTS: Thirty patients met inclusion criteria, consisting of twelve PMEG, seven ZFEN, and eleven open repairs. PMEG repairs had a total CM of -$110,000 compared to $18,000 for ZFEN and $290,000 for OSR. Aortic and branch artery implants were major cost-drivers for endovascular procedures. Extent II TAAA repairs were the costliest PMEG procedure, with a total device cost of $59,000 per case. PMEG repairs had 30-d and 1-y mortality rates of 8.3% which was not significantly different from ZFEN (0.0%, P = 0.46; 0.0%, P = 0.46) or OSR (9.1%, P = 0.95; 18%, P = 0.51). Average intensive care unit and hospital stay after PMEG repairs were comparable to ZFEN and shorter than OSR. CONCLUSIONS: Our study suggests that PMEG repairs yield a negative CM. To make these cases financially viable for hospital systems, device costs will need to be reduced or reimbursement rates increased by approximately $8800.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Humanos , Estudos Retrospectivos , Masculino , Feminino , Procedimentos Endovasculares/economia , Procedimentos Endovasculares/instrumentação , Idoso , Prótese Vascular/economia , Implante de Prótese Vascular/economia , Implante de Prótese Vascular/instrumentação , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/economia , Pessoa de Meia-Idade , Resultado do Tratamento , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/economia , Idoso de 80 Anos ou mais
10.
J Endovasc Ther ; : 15266028241227392, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38288587

RESUMO

INTRODUCTION: The aim of this study is to share preliminary experiences and outcomes with a novel custom-made fenestrated TREO® Abdominal Stent-Graft System to treat juxtarenal and pararenal abdominal aortic aneurysms (AAAs). METHODS: Juxtarenal and pararenal AAA patients treated with the custom-made fenestrated TREO® Abdominal Stent-Graft System were included from 4 high-volume European academic medical centers from June 2021 to September 2023. Technical success and 30-day/in-hospital mortality and complications were analyzed. Technical success was defined as successful endovascular implantation of the stent graft with preservation of antegrade flow to the target vessels, and absence of type 1 or 2 endoleak (EL) at the first postoperative computed tomography angiography (CTA). RESULTS: Forty-two consecutive patients were included. The majority of the devices were constructed with 2 (N=4; 9.5%), 3 (N=9; 21.4%), or 4 (N=27; 64%) fenestrations. In 1 case, the device was constructed with a single fenestration (2.4%) and 1 device contained 5 fenestrations (2.4%); 17% had previous AAA repair. Target vessel cannulation with placement of a bridging stent was successful in all but 1 vessel (99, 3%). One aneurysm-related death occurred in the direct postoperative period and 2 limb occlusions necessitated reintervention during admission. In the median follow-up period of 101 (2-620) days, 3 more patients died due to non-aneurysm-related causes. Technical success was achieved in 90% of the cases. Nineteen ELs were seen on the first postoperative CT scan: 1 type 1b EL (N=1; 2%), 15 type 2 ELs (N=15; 36%), and 3 type 3 ELs (N=3%). Eleven patients received more than 1 CT scan during a median follow-up of 361 days (82-620): 3 type 2 ELs resolved and 1 type 3 EL was treated in this period. In the follow-up, 1 patient had a coagulation disorder that caused occlusions of the branches. CONCLUSION: The results of the first experiences using the custom-made fenestrated TREO® Abdominal Stent-Graft System in Europe are promising. There was a low short-term mortality and morbidity rate in these patients of which 17% had previous AAA repair. Mid-term and long-term follow-up data are needed to evaluate endograft durability and performance. CLINICAL IMPACT: This study shows the first experiences and short-term results of a novel low-profile custom-made device: the custom-made fenestrated TREO® Abdominal Stent-Graft System. Showing these results and experiences can help the physicians in clinical decision-making for their patients.

11.
J Endovasc Ther ; : 15266028241266158, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39058232

RESUMO

PURPOSE: To describe the X-over reversed iliac extension technique in a patient with severe peripheral arterial disease (PAD) scheduled for inner branched endovascular aortic repair (iBEVAR). TECHNIQUE: A multimorbid 62-year-old male patient was planned for iBEVAR due to a 58 mm suprarenal aortic aneurysm. The patient had a previous right femoropopliteal bypass and stenting of the left iliac axis. At admission, he presented with recent onset severe left limb claudication, which was attributed to left iliac stent occlusion. To avoid the postoperative compression of the right common femoral artery (CFA) and preserve the patency of the bypass, a single left CFA access, followed by left iliac artery recanalization, was decided. The right iliac axis was catheterized with a Lunderquist wire using X-over access from the left CFA. An iliac extension (ZISL, 24-59, Cook Medical, Bloomington, USA) was reversed and resheathed on back-table and implanted in the right common iliac artery using the X-over technique. The left CFA access was used to complete the remaining steps of the procedure. The predischarge computed tomography angiography confirmed bilateral iliac artery and femoropopliteal bypass patency. CONCLUSION: The X-over reversed iliac extension technique may be applied in selected PAD patients, when undergoing complex endovascular aortic repair. CLINICAL IMPACT: As the number of patients with peripheral arterial disease (PAD) is expected to increase the upcoming decades, out of the box solutions may be needed to assist complex endovascular aortic management. The X over technique, which consist of the contralateral advancement of an on-table reversed iliac limb, was successfully applied in a patient with severe PAD and numerous previous peripheral interventions, who was managed with branched endovascular aortic repair . The X Over technique may provide an additional alternative in well-selected patients with demanding vascular access undergoing complex endovascular aortic procedures.

12.
J Endovasc Ther ; : 15266028241245326, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605568

RESUMO

OBJECTIVE: This study aimed to assess the long-term outcomes in patients treated by thoracic endovascular aortic repair (TEVAR) for blunt thoracic aortic injuries (BTAI). MATERIALS AND METHODS: From January 2010 to December 2019, this retrospective observational study was conducted at 3 centers, involving 62 consecutive BTAI patients who underwent TEVAR. Computed tomography angiography scans were planned to be conducted at 6 months post-procedure, and annually thereafter. RESULTS: Technical success was achieved in all 62 procedures (100%), which included cases of dissection (n=35, 56.45%), pseudoaneurysm (n=20, 32.26%), and rupture (n=7, 11.29%). Mean injury severity score was 31.66±8.30. A total of 21 supra-arch branches were revascularized by chimney technique, with 12 cases involving the left subclavian artery (LSA) and 9 cases involving the left common carotid artery. In addition, 11 LSAs were covered during the procedure. The in-hospital mortality rate was 1.61% (n=1). The mean follow-up time was 86.82±30.58 months. The all-cause follow-up mortality rate was 3.28% (n=2). Stenosis or occlusion of 3 supra-arch branches (4.92%) was identified at follow-up, with 2 cases (3.28%) requiring re-intervention. No spinal cord ischemia, endoleak, or migration was observed. CONCLUSIONS: Despite only including patients with long-term follow-up, this study confirms the long-term safety and effectiveness of TEVAR for BTAI. For young BTAI patients, as the thoracic aorta increases with age, longer follow-up is needed to observe the potential mismatch between the endograft and the aorta. CLINICAL IMPACT: This study confirms the long-term safety and effectiveness of endovascular treatment for blunt thoracic aortic injury (BTAI). For young BTAI patients, as the thoracic aorta increases with age, longer follow-up is needed to observe the potential mismatch between the endograft and the aorta. Through a remarkably extended follow-up period (86.82±30.58 months) conducted at multiple centers in China, this study confirms the long-term safety and effectiveness of endovascular treatment for BTAI.

13.
J Endovasc Ther ; : 15266028241241006, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528651

RESUMO

PURPOSE: To analyze the early performance and efficacy of the first commercially available off-the-shelf precannulated multibranched endograft in the endovascular repair of pararenal abdominal aortic aneurysms (PAAAs). The device received European marketing approval in late 2020. MATERIALS AND METHODS: Between January 2021 and June 2023, a retrospective analysis of prospectively collected data from all consecutive patients with pAAAs undergoing implantation of the E-nside precannulated inner-branched endograft was conducted in 2 centers. The primary outcome measure was technical success defined as the composite endpoint of successful (1) delivery of the 24F endograft, (2) use of the precannulation tubes, and (3) implantation of the bridging stent-grafts (BSGs) to the target vessels. Main secondary endpoints were mortality, target vessel instability (TVI), absence of type I or III endoleak, reintervention, spinal cord ischemia, and supra-celiac aortic coverage. RESULTS: Twenty-one patients (20 men, mean age: 71 years) were included in this study with a mean follow-up of 14±7.7 months. Nine patients had a symptomatic aneurysm (43%). Technical success amounted to 95% (in one patient, an iliofemoral conduit was necessary to advance the device). One out of 112 BSGs (1%, right renal artery) occluded at 30 days, resulting in freedom from TVI and reintervention rate at 12 months of 95%. No type I or III endoleaks were identified during follow-up. One patient (5%) died at 13 months due to non-aneurysm-related death, and 1 patient (5%) developed spinal cord ischemia. No other major perioperative complications were observed. Mean supra-celiac aortic coverage reached 52±8%. CONCLUSIONS: Given the imperative need for an off-the-shelf endograft tailored to address PAAAs, the E-nside stent-graft demonstrated encouraging outcomes in this study. Nevertheless, it is essential to emphasize that the extent of aortic coverage mandates the production of a truncated variant. CLINICAL IMPACT: The endovascular repair of urgent pararenal aortic aneurysms remains still an unsolved problem in the endovascular era since there are no available off-the-shelf dedicated fenestrated or branched endografts. This paper confirms the safety and efficacy of the off-the-shelf precannulated inner branched endograft for this specific indication.

14.
J Endovasc Ther ; : 15266028241258148, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38850041

RESUMO

PURPOSE: Thoracic endovascular aortic repair (TEVAR), originally conceived for deployment distal to the left subclavian artery (LSA), has been recently extended to more proximal landing zones. Among total endovascular solutions, the "Canaud technique" for Physician-Modified Thoracic Endovascular Grafts (C-PMEGs) has gained acceptance with good early results. The aim of this study is to report the proportion of patients with zone 0, 1, and 2 aortic arch lesions that could theoretically be treated with a C-PMEG. MATERIALS AND METHODS: Computed tomography angiography (CTA) of all consecutive patient candidates to open, hybrid, or endovascular arch repair from January 2009 to July 2023 at our Institution were analyzed. The assessment of feasibility of C-PEMG was conducted following previously extensively described anatomical criteria. RESULTS: During the study period, 209 consecutive patients were candidates for an open, hybrid, or endovascular aortic arch repair. Of them, 164 patients had a preoperative CTA scan eligible for analysis. One hundred twenty-six patients were male (76.8 %), with a mean age of 67 ± 10.8 years. Ninety-four patients (57.3%) were affected by atherosclerotic aneurysms, 48 post-dissecting aneurysms (29.3%) and 22 penetrating aortic ulcers (PAUs) (13.4%). Twenty patients (12.2%) were suitable for double-fenestrated C-PMEG, and 34 patients (20.7%) for single-fenestrated C-PMEG, totaling 32.9% of the entire cohort. The combination of supra-aortic trunks (SAT) bypass or the use of covered stent in IA or left common carotid artery (LCCA) as adjunctive maneuvers, would extend the C-PMEGs feasibility to 69 patients (42.1%). The use of an iliac graft conduit in 3 (1.8%) patients with inadequate ileo-femoral accesses would increase the C-PMEG suitability to 72 patients (43.9%). The main reason for exclusion was excessive ascending aortic diameter in 78 patients (47.6%). CONCLUSIONS: The use of C-PMEG was shown to be theoretically feasible in a percentage of patients ranging from 32.9 to 43.9% affected by aortic arch aneurysms, dissections, and PAU. The main reason for exclusion was the dimension of the ascending aorta. The C-PMEG technique is a viable option in aortic arch lesions endovascular treatment. An off-the-shelf device with similar characteristics could also be used in emergency, avoiding the limitations of physician modifications (such as time for back-table procedure, sterility, off-label use). CLINICAL IMPACT: Thoracic endovascular aortic repair (TEVAR) has been extended to more proximal landing zones for the treatment of aortic arch aneurysm, dissections, penetrating aortic ulcers. Among total endovascular solutions, the "Canaud technique" for Physician-Modified Thoracic Endovascular Grafts (C-PMEGs) has gained acceptance with good early results. The anatomical feasibility in 164 consecutive patients was 69 patients (42.1%), with the combination of supra-aortic trunks (SAT) bypass or the use of covered stent in IA or left common carotid artery (LCCA) as adjunctive maneuvers, showing that the C-PMEG technique is a viable option in aortic arch lesions endovascular treatment.

15.
J Endovasc Ther ; : 15266028241249571, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38721860

RESUMO

PURPOSE: This study aims to explore the feasibility and effectiveness of a unilateral transfemoral access endovascular salvage technique for complex abdominal aortic aneurysms with concurrent type Ia and Ib endoleaks following previous endovascular repair. CASE REPORT: A 69-year-old female with multiple comorbidities presented with an extent IV thoracoabdominal aortic aneurysm complicated by type Ia and Ib endoleaks and chronically occluded left iliac endoprosthesis after prior endovascular repair. Given the patient's medical complexities, open explant repair was deemed high risk. The case was successfully managed using a physician-modified fenestrated/branched endograft (PM-F/BEVAR) and an iliac branch device (IBD) deployed through a single percutaneous transfemoral access. CONCLUSION: The presented case demonstrates the safety and efficacy of PM-F/BEVAR with concomitant IBD deployment via unilateral transfemoral access. This innovative approach allows endovascular salvage in cases with restricted iliofemoral access and avoids the complexities associated with upper extremity or aortic arch manipulation. While acknowledging the technical challenges, this technique offers a viable alternative for salvaging failed endovascular repairs, emphasizing the importance of real-time modifications in achieving successful outcomes. Further studies and long-term follow-up are warranted to validate the broader applicability and durability of this approach in the management of complex abdominal aortic aneurysms with multiple endoleaks. CLINICAL IMPACT: Although not the conventional approach, unilateral transfemoral access can be utilized to implant either a physician-modified fenestrated aortic endograft or an iliac branch device. Such an approach avoids complicating issues related to upper extremity access. This innovative technique may be necessary when there is a failed prior EVAR in the setting of significant contralateral iliofemoral occlusive disease. Doing both procedures in the same setting to resolve a type Ia and Ib endoleak is feasible as demonstrated in this case report. Expanding the endovascular armamentarium to address EVAR failure will be increasingly useful in the future, especially given the morbidity profile of EVAR explantation.

16.
Artigo em Inglês | MEDLINE | ID: mdl-38879148

RESUMO

OBJECTIVE: To evaluate sex based differences in ascending aorta and arch anatomy in patients with underlying proximal aortic disease and to evaluate their impact on feasibility for total endovascular repair with custom made, branched arch devices. METHODS: This was a retrospective cross sectional review of all patients undergoing open and or total endovascular arch repair due to distal ascending aorta and or aortic arch pathologies in a single high volume aortic centre between 2012 and 2022. Anatomical ascending aorta and aortic arch parameters were analysed on a flow centreline on a dedicated 3D workstation. Sex related differences of the ascending aorta, aortic arch, and supra-aortic vessels were evaluated. Subsequently, four endovascular devices were assessed for feasibility: double and triple branched devices both for the Zenith (Cook Medical) and Relay (Terumo Aortic) platforms, first in accordance with the instructions for use and then considering the possibility of adjunctive cervical debranching. The primary endpoints were sex specific differences in aortic anatomy, while secondary endpoints included sex based feasibility of branched endograft devices. RESULTS: During the study period, 395 patients underwent total aortic arch repair, of whom 152 (51 female, 33.5%) had high quality computed tomography angiograms available and were included in the study. Female patients had a shorter proximal landing zone than males (22 mm vs. 47 mm; p < .001). Left subclavian artery dissection was more frequent in men (24.8% vs. 3.9%; p < .001). Other anatomical parameters showed a similar distribution between sexes. Female patients presented a lower feasibility for double branched devices (35.3% vs. 58.4%; p = .015) as well as a tendency for lower feasibility rates for triple branched devices (31.4% vs. 47.5%; p = .081). CONCLUSION: Although most ascending aortic and arch parameters showed similar trends in both sexes, the availability of a suitable proximal landing zone was lower in female patients. Consequently, female patients had lower feasibility rates for double arch branched endografts and, to lesser extent, for triple arch branched endografts.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38641315

RESUMO

OBJECTIVE: This multicentre study aimed to assess the early and midterm outcomes of physician modified fenestrated endografts (PMEGs) for endovascular aortic arch repair in zone 0. METHODS: Between 2018 and 2022, a retrospective study was conducted in three centres of consecutive patients undergoing endovascular aortic arch repair in zone 0 with PMEGs. Endpoints included technical success, 30 day mortality rate, major adverse events, secondary interventions, stent stability, target vessel patency, and overall survival. RESULTS: A total of 54 patients (mean age 63 years; 45 males) with aortic arch pathology were included, comprising aortic dissections (n = 32; 59%) and aortic arch aneurysms (n = 22; 41%). Technical success was 98%. One patient died from stroke within 30 days. Major adverse events included stroke (n = 4; 7%), retrograde type A dissection (RTAD) (n = 3; 6%), and acute kidney injury (n = 2; 4%). During a median follow up of 12 months, there were two deaths (4%) of unknown cause at one month and 1.5 months, and no aortic related death. Type Ia, type Ic, and type IIIc endoleaks were observed in two (4%), three (6%), and two (4%) patients, respectively. No vessel stenosis was observed. Re-intervention was required in 10 patients (19%). Estimates of overall survival, freedom from secondary intervention, and freedom from target vessel instability at one year were 94.2% (standard error [SE] 3.3%), 81.8% (SE 6.0%), and 92.0% (SE 4.5%), respectively. CONCLUSION: This study has demonstrated the efficacy of PMEGs for zone 0 endovascular aortic arch repair, with acceptable technical success and mortality rates. Stroke, RTAD, and re-intervention rates remain a concern for endovascular therapy. A larger population and long term outcomes are required to assess the safety and durability of this technique as a beneficial choice for endovascular aortic arch repair in specialised centres.

18.
Ann Vasc Surg ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38960091

RESUMO

BACKGROUND: The unibody bifurcated aortic endograft (AFX/AFX2) has emerged as a treatment option for abdominal aortic aneurysms (AAAs). This systematic review and meta-analysis aimed to evaluate the safety of the unibody endograft. METHODS: A literature search was conducted in Cochrane Library, Scopus, Web of Science, and PubMed. Studies assessing the unibody endograft for abdominal aortic aneurysm repair between 2014 and 2023 were included. The defined primary outcomes were the incidences of type I, II, and III endoleaks. The secondary outcomes were access site problems, aneurysm-related mortality, aneurysm rupture, all-cause mortality, aneurysm sac growth, limb occlusion, stent graft migration, and technical success rate. RESULTS: 14 studies including 12 observational studies and two randomized controlled trials (RCTs) were included in the systematic review. The meta-analysis included 10 studies with 12,690 patients that reported the measured outcomes, and excluded four studies that did not. Type II endoleaks had the highest incidence of 12% (95% CI: 4-20%), followed by type III endoleaks with an incidence of 3% (95% CI: 1-5). The incidence of type I endoleaks was 1% (95% CI: 0-2%). A subgroup analysis by follow-up duration showed that type II endoleak incidence was higher after one to two years of follow-up than three to four years of follow-up. The incidence of aneurysmal mortality was 2% (95% CI: 0-7%); limb occlusion was 1% (95% CI: 0-1%); stent graft migration was 1% (95% CI: 0-2%); aneurysmal rupture was 6% (95% CI: 2-11%); access site problems were 7% (95% CI: 2-13%); aneurysm sac growth was 2% (95% CI: 0-4%);, all-cause mortality was 21% (95% CI: 4-38%), and technical success rate was 100% (95% CI: 98-100%). CONCLUSION: The unibody endograft is a safe and minimally invasive approach for AAA repair. However, potential complications necessitate close patient follow-up after the intervention.

19.
Circulation ; 146(15): 1149-1158, 2022 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-36148651

RESUMO

BACKGROUND: Hybrid debranching repair of pararenal and thoracoabdominal aortic aneurysms was initially designed as a better alternative to standard open repair, addressing the limitations of endovascular repair involving the visceral aorta. We reviewed the collective outcomes of hybrid debranching repairs using extra-anatomic, open surgical debranching of the renal-mesenteric arteries, followed by endovascular aortic stenting. METHODS: Data from patients who underwent hybrid repair in 14 North American institutions during 10 years were retrospectively reviewed. Society of Vascular Surgery scores were used to assess comorbidity risk. Early and late outcomes, including mortality, morbidity, reintervention, and patency were analyzed. RESULTS: A total of 208 patients (118 male; mean age, 71±8 years old) were treated by hybrid repair with extraanatomic reconstruction of 657 renal and mesenteric arteries (mean 3.2 vessels/patient). Mean aneurysm diameter was 6.6±1.3 cm. Thoracoabdominal aortic aneurysms were identified in 163 (78%) patients and pararenal aneurysms in 45 (22%). A single-stage repair was performed in 92 (44%) patients. The iliac arteries were the most common source of inflow (n=132; 63%), and most (n=150; 72%) had 3 or more bypasses. There were 30 (14%) early deaths, ranging widely across sites (0%-21%). A Society of Vascular Surgery comorbidity score >15 was the primary predictor of early mortality (P<0.01), whereas mortality was 3% in a score ≤9. Early complications occurred in 140 (73%) patients and included respiratory complications in 45 patients (22%) and spinal cord ischemia in 22 (11%), of whom 10 (45%) fully recovered. At 5 years, survival was 61±5%, primary graft patency was 90±2%, and secondary patency was 93±2%. The most significant predictor of late mortality was renal insufficiency (P<0.0001). CONCLUSIONS: Mortality after hybrid repair and visceral debranching is highly variable by center, but strongly affected by preoperative comorbidities and the centers' experience with the technique. With excellent graft patency at 5 years, the outcomes of hybrid repair done at centers of excellence and in carefully selected patients may be comparable (or better) than traditional open or even totally endovascular approaches. However, in patients already considered as high-risk for surgery, it may not offer better outcomes.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aorta/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Complicações Pós-Operatórias/etiologia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
J Vasc Surg ; 77(2): 440-445, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36252827

RESUMO

BACKGROUND: Limb thrombus formation is a complication that can occur after endovascular aortic repair (EVAR), and its clinical significance has continued to be debated. Our objective was to report the incidence of limb thrombus after EVAR and determine the association of specific demographic, anatomic, and/or graft variables. METHODS: A retrospective analysis of EVAR patients at a single tertiary center between January 2010 and December 2018 was performed to determine the limb thrombus rate. Demographic, graft, and anatomic variables were analyzed for an association with limb thrombus. RESULTS: A total of 301 patients were included. The average follow-up was 27.6 ± 4.9 months. The mean age was 76.5 ± 0.5 years, and 85% were men. Limb thrombus occurred in 22 patients (7.3%). Of these 22 patients, 11 (50.0%) had had occlusive limb thrombus, 14 (63.6%) were symptomatic, and 17 (77.3%) had required intervention. The patients with limb thrombus were younger (69.8 ± 1.3 years vs 77.1 ± 0.5 years; P < .0001) and more likely to be smokers (10.2% vs 5.2%; P = .10). The incidence of limb thrombus with the Alpha graft (10.7%; Cook Medical Inc, Bloomington, IN) was compared with that with non-Cook grafts (4.0%; P = .07). The average common iliac artery diameter for patients with and without limb thrombus was 14.1 mm and 16.1 mm, respectively (P < .01). Right-sided limb thrombus was more likely in smaller right iliac arteries (14.7 ± 0.9 cm vs 17.0 ± 0.6 cm; P < .05), with a similar finding on the left (13.6 ± 0.9 cm vs 15.2 ± 0.4 cm; P = .13). Unilateral limb thrombus was almost twice as likely on the main body side than on the contralateral side (11 vs 6). Limb thrombus was not associated with aortoiliac disease (odds ratio [OR], 1.31; 95% confidence interval [CI], 0.37-4.62), limb extension (OR, 0.47; 95% CI, 0.06-3.62), or nonmatching limb heights (OR, 1.36; 95% CI, 0.54-3.43). Limb thrombus was also not associated with increased 30-day mortality (P > .05). CONCLUSIONS: Limb thrombus formation is a complication that can occur after EVAR (7.3%). In our study, limb thrombus was seen more frequently in younger patients and those who smoked. Cook Alpha grafts had a thrombus formation rate of 10.7%, which was not significantly higher than that with other brands. Limb thrombus was more likely in smaller iliac arteries and on the main body side.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Feminino , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Stents , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Estudos Retrospectivos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA