Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Ophthalmologica ; 247(4): 241-250, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39004074

RESUMO

INTRODUCTION: Extended depth of focus (EDOF) intraocular lens (IOL) offers improved near and intermediate vision, aiming to reduce spectacle dependence in cataract patients. This research aimed to evaluate the performance of EDOF IOL in patients with retinal pathologies following cataract surgery. METHODS: The medical charts of thirty-three eyes with retinal pathologies and 100 healthy eyes that underwent cataract extraction with implantation of an EDOF IOL and had at least 3 weeks of postoperative follow-up were retrospectively included. Patients' overall satisfaction, spectacle dependence, visual perception, and side effects were evaluated with a self-reported questionnaire. RESULTS: Mean uncorrected visual acuities (LogMAR) were significantly better in the healthy eyes compared with the eyes with retinal pathologies: 0.05 and 0.10, p = 0.011 (distance), 0.06 and 0.16, p = 0.001 (intermediate), and 0.20 and 0.28, p = 0.026 (near), respectively. No or rare use of spectacles for any distance was reported by 71% and 38% of patients, respectively (p = 0.004). Haloes/glare were reported by 17% and 23%, respectively (p = 0.556); only in 7% and 4% it was clinically disturbing (p > 0.999). The same IOL would be chosen again in 77% and 73% of patients, respectively, (p = 0.550). CONCLUSION: Patients with retinal pathologies who were implanted with an EDOF IOL demonstrated excellent distant uncorrected visual results with reasonable intermediate and near uncorrected visual results alongside high satisfaction; however, results were inferior to those of the control healthy eyes.


Assuntos
Percepção de Profundidade , Lentes Intraoculares , Desenho de Prótese , Doenças Retinianas , Acuidade Visual , Humanos , Feminino , Estudos Retrospectivos , Masculino , Idoso , Pessoa de Meia-Idade , Doenças Retinianas/fisiopatologia , Doenças Retinianas/cirurgia , Doenças Retinianas/diagnóstico , Percepção de Profundidade/fisiologia , Seguimentos , Satisfação do Paciente , Refração Ocular/fisiologia , Inquéritos e Questionários , Implante de Lente Intraocular/métodos , Pseudofacia/fisiopatologia , Idoso de 80 Anos ou mais , Facoemulsificação/métodos , Adulto
2.
Graefes Arch Clin Exp Ophthalmol ; 261(9): 2567-2573, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37071152

RESUMO

PURPOSE: To compare long-term visual function after implantation of diffractive extended depth-of-focus (EDF) intraocular lenses (IOLs) using echelett optics and monofocal IOLs with the same platform. METHODS: In this prospective comparative case series, diffractive EDF or monofocal IOLs were implanted binocularly and followed up for 2 years. At the last visit, distance-corrected binocular visual acuities were measured at distances of 0.3, 0.5, 0.7, 1, 2, 3, and 5 m. Photopic and mesopic contrast sensitivity was also examined. Dynamic visual function was evaluated in terms of functional visual acuity (FVA), standard deviation of visual acuity (SDVA), visual maintenance ratio (VMR), mean response time, and number of blinks. The outcomes were compared between the two IOLs, and the influence of posterior capsule opacification (PCO) on contrast sensitivity and FVA was examined. RESULTS: Binocular visual acuity of eyes with EDF IOLs was better at distances of 0.5 and 0.7 m than that of eyes with monofocal IOL (P < 0.026). There were no differences in binocular visual acuity at other distances, contrast sensitivities, or dynamic visual functions. The influence of PCO on the visual functions was not found in eyes with EDF IOLs. CONCLUSION: Up to 2 years postoperatively, eyes with diffractive EDF IOLs sustained superior intermediate visual acuity together with visual function comparable to that of eyes with monofocal IOLs.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Acuidade Visual , Sensibilidades de Contraste , Desenho de Prótese , Pseudofacia
3.
Int Ophthalmol ; 43(11): 3989-3997, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37458945

RESUMO

PURPOSE: To evaluate the tolerance for refractive errors and visual outcomes of extended depth of focus intraocular lens (EDOF IOLs) in patients with previous corneal refractive surgery for myopia. METHODS: Patients from Aier Eye Hospital of Wuhan University with previous myopia excimer laser correction underwent cataract surgery and implantation of an EDOF IOL. The follow-up period was three months. The uncorrected distance, intermediate, and near visual acuities (UDVA, UIVA, UNVA), corrected distance visual acuity (CDVA), spherical equivalent (SE), defocus curve, optical quality, including modulation transfer functions (MTF) and Strehl ratio (SR), National Eye Institute Visual Functioning Questionnaire-14 for Chinese people (VF-14-CN), spectacle independence, and dysphotopsia were assessed. RESULTS: At the final visit, UDVA, CDVA, UIVA, and UNVA (LogMAR) were 0.06 ± 0.09, 0.01 ± 0.06, 0.11 ± 0.08, 0.20 ± 0.10, respectively. The mean spherical equivalent (SE) was - 0.57 ± 0.58D, sphere and cylinder were - 0.24 ± 0.60D, - 0.70 ± 0.58D respectively. No statistical difference in UDVA between eyes with SE in ± 0.50 D and in ± 1.0 D (p > 0.05). Corneal astigmatism > 1.00D has no significant effect on postoperative visual acuity (p > 0.05). The defocus curve showed that visual acuity could reach 0.2 in the refractive range of + 0.50D ~ - 1.50D. SR and MTF values were all higher than before the surgery. In bilateral implantation patients, the VF-14-CN questionnaire score and visual quality were quite excellent. CONCLUSION: The EDOF IOL have a certain tolerance for refractive errors and corneal astigmatism, and it's recommended for patients with prior myopia excimer laser surgery to achieve satisfactory visual performance.


Assuntos
Astigmatismo , Lentes Intraoculares , Miopia , Facoemulsificação , Erros de Refração , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Implante de Lente Intraocular/efeitos adversos , Facoemulsificação/efeitos adversos , Estudos Prospectivos , Lentes Intraoculares/efeitos adversos , Refração Ocular , Desenho de Prótese , Satisfação do Paciente
4.
Int Ophthalmol ; 43(4): 1143-1152, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36125586

RESUMO

PURPOSE: To compare binocular static visual acuity (SVA), stereopsis, contrast sensitivity (CS) and dynamic visual acuity (DVA) of 5 combinations of bifocal intraocular lenses (IOLs), trifocal IOLs and extended-depth-of-focus (EDOF) IOLs in age-related cataract patients. METHODS: Two hundred and ninety-two eyes of 146 patients who underwent cataract surgery in the ophthalmology department of the First Affiliated Hospital of Chongqing Medical University were involved. Subgroups included group MM (33patients, bilaterally bifocal IOL, ZMB00), group TT (31patients, bilaterally trifocal IOL, AT LISA tri839MP), group XX (34patients, bilaterally EDOF IOL, ZXR00), group MX (25patients, bifocal IOL, ZMB00 + EDOF IOL, ZXR00) and group TX (23patients, trifocal IOL, AT LISA tri839MP + EDOF IOL, ZXR00). The uncorrected SVAs (UDVA, UIVA and UNVA), uncorrected DVAs (UDDVA, UIDVA and UNDVA), near and distance stereopsis, and CS were assessed 3 months postoperatively. RESULTS: Subgroups of TT, XX, MX and TX showed better UIVA than MM (bP = 0.039, 0.021, 0.035 and 0.037, respectively). MX showed better UNVA than MM and TX (bP = 0.031 and 0.013, respectively). MX group had the optimal outcomes of both near and distance stereopsis. In the UDDVA, XX group and MX group showed better outcomes than TX group at 24 fps (frames per second) (bP = 0.019 and 0.023, respectively). XX group and MX group showed optimal outcomes at all speeds of UIDVA (P = 0.001, 0.005, 0.003 and 0.005, respectively). As the speed increased, the XX group and the MX group showed better UNDVA than the MM group and the TT group (P = 0.019, 0.002 and 0.003, respectively). CONCLUSIONS: Mix-and-match implantation of bifocal IOLs and EDOF IOLs provides excellent and stable binocular visual outcomes including SVA, stereopsis and DVA in distant and near distances.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Refração Ocular , Implante de Lente Intraocular , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Pseudofacia
5.
Graefes Arch Clin Exp Ophthalmol ; 260(12): 3883-3888, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35796821

RESUMO

PURPOSE: To evaluate the clinical outcomes of extended depth-of-focus (EDoF) AcrySof® Vivity® intraocular lens in eyes with low-grade epiretinal membrane (ERM). METHODS: Forty-five eyes with low-grade ERM and history of Vivity implantation were compared with 50 age-matched controls with Vivity implantation and no ERM. Eyes with ERM showing widening of the outer nuclear layer and loss of the foveal depression, but no ectopic inner foveal layer or outer retinal defect were eligible. Corrected and uncorrected distant visual acuity (CDVA and UDVA), uncorrected intermediate and near visual acuity (UIVA and UNVA), contrast sensitivity detected by area under the log contrast sensitivity function (AULCSF), Strehl ratio, area ratio, and occurrence of dysphotopsia were compared between groups. RESULTS: UDVA and CDVA were similar between groups (UDVA: 0.01 ± 0.05 vs 0.03 ± 0.06, P = 0.154; CDVA: 0.00 ± 0.00 vs 0.00 ± 0.02, P = 0.125). UIVA and mesopic AULCSF were significantly worse in eyes with ERM compared to those with no ERM (UIVA: 0.09 ± 0.09 vs 0.14 ± 0.10, P = 0.028; mesopic AULCSF: 1.26 ± 0.15 vs 1.17 ± 0.10, P = 0.013). The occurrence of dysphotopsia was similar in both groups (glare: P = 0.465; halo: P = 0.218; starburst: P = 0.457). DISCUSSION: Eyes with low-grade ERM showed comparable outcomes to eyes without ERM after Vivity IOL implantation. Implantation of this newly developed EDoF IOL with low addition can be of benefit to eyes with low-grade, reversible ERM that is limited to the inner retina.


Assuntos
Membrana Epirretiniana , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Membrana Epirretiniana/diagnóstico , Membrana Epirretiniana/cirurgia , Acuidade Visual , Ofuscação , Transtornos da Visão , Desenho de Prótese , Refração Ocular , Satisfação do Paciente
6.
BMC Ophthalmol ; 21(1): 418, 2021 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-34863126

RESUMO

BACKGROUND: The prospective comparative case series aimed to evaluate all-distance visual acuity, contrast sensitivity, and functional visual acuity (FVA) of eyes with diffractive extended depth-of-focus (EDOF) intraocular lenses (IOLs) using an echelett optics and monofocal IOLs with the same platform. METHODS: Diffractive EDOF and monofocal IOLs were implanted in 27 eyes of 27 patients each. At 3 months after implantation, all-distance visual acuities at distances of 0.3, 0.5, 0.7, 1, 2, 3, and 5 m were measured under distance-corrected. Static visual function was also examined using photopic contrast sensitivity and area under the logarithmic contrast sensitivity function (AULCSF). Dynamic visual function was examined with FVA, and mean FVA value, visual maintenance ratio (VMR), mean response time, and number of blinks were evaluated. These outcomes were compared between the two IOLs. RESULTS: The mean distance-corrected visual acuities were better at distances of 0.7 m or nearer in eyes with EDOF IOLs. There was no difference in the contrast sensitivities (P > 0.22). In the FVA results, no difference was found in mean FVA and VMR (P > 0.68). CONCLUSION: The static and dynamic evaluations of postoperative visual functions demonstrated that the visual function of eyes with EDOF IOLs under photopic and distance-corrected conditions was comparable to eyes with monofocal IOLs.


Assuntos
Lentes Intraoculares , Pseudofacia , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/cirurgia , Acuidade Visual
7.
Ophthalmol Ther ; 2024 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-39305442

RESUMO

INTRODUCTION: The aim of this prospective and comparative study was to investigate the association of perimetry parameters on visual acuity and contrast sensitivity in primary open-angle glaucoma (POAG) eyes with diffractive extended depth-of-focus (EDoF) and monofocal intraocular lenses (IOLs). METHODS: In cataract eyes with medicinally controlled POAG with no defects in the central visual field and mean deviation (MD) values of - 10 dB or better, EDoF and monofocal IOLs with the same platform except for echelette optics for EDoF were implanted in 22 and 24 eyes, respectively. Corrected distance visual acuity (CDVA), contrast sensitivity at 3 to 18 cycles per degree (cpd), and automated perimetry using 30-2 and 10-2 Swedish Interactive Threshold Algorithm programs were examined 3 months postoperatively. The influences of perimetry parameters including MD, foveal sensitivity (FS), and the means of the central four points (central MD and central FS) on CDVA and contrast sensitivity were evaluated using linear and multiple regression analyses. RESULTS: In POAG eyes with EDoF IOLs, contrast sensitivities at 12 and 18 cpd were associated with 30-2 and 10-2 perimetry parameters. In POAG eyes with monofocal IOLs, associations of 30-2 parameters were found in CDVA and 3-cpd contrast sensitivity. CONCLUSIONS: The visual function of POAG eyes with EDoF IOLs was associated with perimetry parameters in high spatial frequency contrast sensitivity, which was different from that of POAG eyes with monofocal IOL. TRIAL REGISTRATION: Japan Registry for Clinical Research: jRCTs032200218.

8.
Saudi J Ophthalmol ; 37(4): 331-336, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38155684

RESUMO

PURPOSE: To compare the visual outcome findings between a new monofocal intraocular lens (IOL) (Tecnis Eyhance) and extended depth of focus (EDOF) IOL (Appasamy Supraphob Infocus). METHODS: This prospective comparative interventional study evaluated 31 patients after implantation of Tecnis Eyhance (15 patients) and Supraphob EDOF IOL (16 patients). The uncorrected and corrected distance and intermediate and near visual acuity were measured at postoperative day 1, 1 week, 4 week, and 3 months. Contrast sensitivity, incidence of halos and glares, and patient satisfaction were assessed at 3 months postoperatively. RESULTS: The Tecnis Eyhance (n = 15) and Supraphob EDOF (n = 16) group were comparable with respect to all preoperative parameters including biometry, visual acuity, and cataract status. The average age distribution of participants was 56 ± 6 years. Postoperatively, both groups had similar distance and intermediate vision, but the near vision was significantly better in the EDOF group (P < 0.01) as compared to Tecnis Eyhance at 3 months. The contrast sensitivity and patient satisfaction were similar in both the groups. The incidence of halos and glares was present in the EDOF group, but it was statistically insignificant. CONCLUSION: The Tecnis Eyhance and Supraphob EDOF both were effective in improving distance and intermediate vision, but the near vision was significantly better in the EDOF group. Both the groups retained good contrast sensitivity and the majority of patients were satisfied.

9.
Bioengineering (Basel) ; 10(9)2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37760095

RESUMO

The incidence of both cataract and glaucoma is increasing globally. With increasing patient expectation and improved technology, premium intraocular lenses (IOLs), including presbyopia-correcting and toric IOLs, are being increasingly implanted today. However, concerns remain regarding the use of premium IOLs, particularly presbyopia-correcting IOLs, in eyes with glaucoma. This systematic review evaluates the use of premium IOLs in glaucoma. A comprehensive search of the MEDLINE database was performed from inception until 1 June 2023. Initial search yielded 1404 records, of which 12 were included in the final review of post-operative outcomes. Studies demonstrated high spectacle independence for distance and good patient satisfaction in glaucomatous eyes, with positive outcomes also in post-operative visual acuity, residual astigmatism, and contrast sensitivity. Considerations in patient selection include anatomical and functional factors, such as the type and severity of glaucomatous visual field defects, glaucoma subtype, presence of ocular surface disease, ocular changes after glaucoma surgery, and the reliability of disease monitoring, all of which may be affected by, or influence, the outcomes of premium IOL implantation in glaucoma patients. Regular reviews on this topic are needed in order to keep up with the rapid advancements in IOL technology and glaucoma surgical treatments.

10.
Am J Ophthalmol Case Rep ; 29: 101792, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36632337

RESUMO

Purpose: Implantation of presbyopia-correcting intraocular lenses (IOLs) has not been advised for glaucomatous eyes because of the risk of decreased contrast sensitivity with progress of glaucoma. Extended depth-of-focus (EDF) IOLs have been reported to provide comparable postoperative visual function and influence on the visual field to monofocal IOLs. Methods: This case series was a retrospective medical record review of 16 eyes of 10 patients who had normal tension glaucoma (NTG) with no central visual field defects and underwent cataract surgery with implantation of diffractive EDF IOLs. At 3 months postoperatively, distance-corrected visual acuities (DCVAs) at distances of 5, 1, and 0.5 m and photopic contrast sensitivity were examined. Automated perimetry using the 30-2 Swedish interactive threshold algorithm was also performed, and the mean variance (MD) values, mean deviation values at the central four points (central MD), and foveal threshold were recorded. Results: The mean age of the patients (5 men, 5 women) was 66.5 years. Over 80% of eyes obtained DCVAs of 20/20, 20/20, and 20/25 at 5 m, 1 m, and 0.5 m, respectively. Whereas 5 of 16 eyes were categorized as severe by the Hodapp-Parrish-Anderson classification, postoperative contrast sensitivity was within the normal range, except for 4 eyes at 18 cycles per degree. Conclusions and importance: In this case series, the postoperative visual functions of NTG patients with EDF IOLs were almost comparable to those of normal eyes with the same IOLs, which demonstrated that the use of EDF IOLs for controlled NTG eyes would be permissible. While careful patient selection and follow-up for NTG progress are important, further investigations are necessary for confirming the safety and exploring the selection criteria.

11.
Eye Vis (Lond) ; 10(1): 5, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36721199

RESUMO

BACKGROUND: The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus (EDOF) and monofocal intraocular lens (IOL). METHODS: A total of 62 age-related cataract patients receiving phacoemulsification with implantation of TECNIS Symfony (ZXR00) or monofocal IOLs were enrolled. The binocular static and dynamic defocus curves with corrected distance visual acuity were evaluated at one month postoperatively. RESULTS: The ZXR00 group achieved significantly better intermediate (P = 0.044) and near (P = 0.017) visual acuity (VA) than the monofocal group. Two groups had similar uncorrected and corrected distance VA (P > 0.05, respectively). The dynamic defocus curve revealed a smoother decline from 0.0 D to - 2.0 D in the ZXR00 group. Defocused dynamic VA in the ZXR00 group was significantly better (P < 0.05) except at 0.0 D (P = 0.724) and - 0.5 D (P = 0.176). The area under the curve (P = 0.002) and corrected dynamic vision accommodation (P = 0.001) derived from the dynamic defocus curves were better in the ZXR00 group. A positive correlation was observed between defocused dynamic and static VA in both groups (P < 0.001). Multiple linear regression analysis indicated that defocused static VA and corrected dynamic vision accommodation were significant influential factors for the defocused dynamic VA from - 1.0 D to - 3.0 D (P < 0.05). CONCLUSIONS: The EDOF IOL provided similar distance vision, better intermediate and near vision, and a better overall dynamic defocus curve than the monofocal IOL. The dynamic defocus curve may be comprehensively applied to evaluate the all-distance dynamic visual performance post-cataract surgery.

12.
Ophthalmol Ther ; 12(6): 3099-3108, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37695487

RESUMO

INTRODUCTION: The aim of this prospective study was to compare the visual functions of extended depth-of-focus intraocular lenses (EDOF IOLs) and monofocal IOLs in eyes with mild to moderate primary open-angle glaucoma (POAG). METHODS: Cataractous eyes with POAG controlled using medical treatments, no central visual field defects, and mean deviation (MD) values of -10 dB or better on the 30-2 test grid of the Swedish Interactive Threshold Algorithm standard program were included. Twenty-two eyes of 22 patients received EDOF IOLs (ZXR00V and ZXV150-375; J&J), whereas 24 eyes of 24 patients received monofocal IOLs (ZCB00V and ZCV150-375; J&J). MD values, corrected distance visual acuity (CDVA), and photopic contrast sensitivity were measured at 3 months after surgery. Noninferiority of CDVA and contrast sensitivity in eyes with EDOF IOLs to eyes with monofocal IOLs were examined. RESULTS: The postoperative mean MDs of eyes with EDOF and monofocal IOLs were -2.76 dB and -4.21 dB with no significant difference. The CDVA of eyes with EDOF IOLs was noninferior to that of eyes with monofocal IOLs (P = 0.02). There were no inferiority in contrast sensitivity at any spatial frequency (P < 0.001). CONCLUSIONS: The visual function of EDOF IOLs in eyes with mild-to-moderate POAG was not inferior to that of monofocal IOLs. TRIAL REGISTRATION: Registered in the Japan Registry for Clinical Research (identifier: jRCTs032200218).

13.
Oman J Ophthalmol ; 16(3): 482-488, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38059085

RESUMO

AIM: This aims to study visual satisfaction and spectacle independence in prepresbyopic age patients with cataracts after the implantation of either monofocal intraocular lens (IOL) with enhanced intermediate vision or trifocal IOL. SETTING: Private practice. MATERIALS AND METHODS: This prospective, observational case study was conducted on patients in the prepresbyopic age group with cataracts. Patients were allocated to one of the two groups. Thirteen patients (26 eyes) received monofocal IOL with enhanced intermediate vision (intermediate vision group), and 12 patients (24 eyes) received diffractive multifocal IOLs (trifocal group). Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity, Uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA) values, defocus curves, and contrast sensitivities (CS) of the two groups were compared 3 months' postsurgery. Their spectacle independence and visual satisfaction were also assessed. RESULTS: The study patients were aged 35-45 years and comprised 14 males and 11 females. No significant difference was observed in UDVA (intermediate vision group: 0.02 ± 0.01, trifocal group: 0.02 ± 0.01; P = 0.22) and UIVA (intermediate vision group: 0.20 ± 0.10, trifocal group: 0.19 ± 0.10; P = 0.12). However, a statistically significant difference was observed between the groups in terms of UNVA (intermediate vision group: 0.32 ± 0.10, trifocal group: 0.80 ± 0.10; P = 0.01). The mean CS in monofocal IOL with enhanced intermediate vision and trifocal groups were 1.577 ± 0.3 and 1.550 ± 0.2, respectively (P = 0.40). None of the patients experienced photic phenomena. In total, 10 of 13 patients in the monofocal IOL with enhanced intermediate vision group required spectacle correction for near visual acuity in the range of +1.00 to +2.00 D. CONCLUSION: This study found that there was no significant difference in distance and intermediate vision between the two groups. However, the trifocal group had better uncorrected near vision compared to the monofocal group that had enhanced intermediate vision. The conclusion is that using trifocal IOLs for both eyes provided complete independence from wearing glasses. In addition, no visual disturbances were observed after implanting the new-generation trifocal IOLs.

14.
Front Med (Lausanne) ; 9: 1042101, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36341263

RESUMO

Purpose: To compare stereopsis and visual acuity (VA) between bilateral implantation of trifocal intraocular lenses (IOL) and blended implantation of an extended depth of focus (EDOF) IOL with a bifocal IOL. Methods: This is a non-randomized, prospective comparative study included 74 eyes of 37 patients who underwent phacoemulsification and bilateral implantation of AT LISA tri 839MP IOL (bilateral group; 21 patients) or blended implantation of Tecnis Symfony ZXR00 and Tecnis ZLB00 IOL (blended group; 16 patients). The primary outcomes were stereoacuity and binocular VA. The secondary outcomes were visual defocus curve, quality of life, and patient satisfaction. Follow-up was performed 3 months after the surgery. Results: The mean near stereoacuity was 49.76 ± 22.67 and 120.63 ± 90.94 seconds of arc (arcsec) in the bilateral and blended groups, respectively (P < 0.001). Near stereoacuity was positively correlated with VA difference of two eyes (r = 0.896, P < 0.001). The mean binocular uncorrected visual acuity at 40 cm, 80 cm, 5 m, and corrected distance visual acuity at 5 m of the bilateral and blended groups was not statistically significant different. The bilateral group had better VA at a vergence from -2.5 to -4.0 D. Both groups obtained high quality of life and patient satisfaction scores. Conclusion: The bilateral and blended groups achieved good binocular VA, quality of life, and high patient satisfaction. However, the near stereoacuity of the blended group was worse.

15.
J Fr Ophtalmol ; 45(5): 529-536, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35090757

RESUMO

PURPOSE: To evaluate visual outcomes at 3 months after bilateral implantation of a new EDOF intraocular lens in a routine cataract population. METHODS: Prospective evaluation of 12 patients (24 eyes) implanted bilaterally with an EDOF intraocular lens (IOL) with emmetropia as the target. Visual acuity at distance, intermediate (70cm) and near (40cm) with and without distance correction, refractive error, monocular photopic defocus curve and contrast sensitivity curve with best corrected distance refraction were measured. Subjective outcomes in terms of visual function, spectacle independence, lighting independence, dysphotopsia and overall satisfaction were assessed at three months. RESULTS: The mean age of the patients was 68.33 years±10.30. The mean IOL power was 21.5±2.44 D. Three months after surgery, the mean decimal uncorrected distance (UCDVA), intermediate (UCIVA) and near (UCNVA) visual acuities were 0.10, 0.09 and 0.23 logMAR respectively. The monocular defocus curve with distance correction showed 1.75 D of depth of field with an acuity better than 0.3 logMAR. Patient satisfaction was high, with a low occurrence of dysphotopsia. CONCLUSION: The A-constant should be optimized for better predictability. The EDOF IOL showed satisfactory visual performance after cataract surgery, with high patient satisfaction and a low occurrence of visual disturbances. It resulted in good distance and intermediate vision, but might require spectacles for small print at a near distance.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Idoso , Catarata/complicações , Percepção de Profundidade , Humanos , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares/efeitos adversos , Satisfação do Paciente , Facoemulsificação/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Pseudofacia , Refração Ocular
16.
Acta Ophthalmol ; 99(6): e837-e843, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33191658

RESUMO

PURPOSE: To evaluate differences in subjective and objective refractions in eyes with extended-depth-of-focus intraocular lenses (EDOF IOLs) using echelette optics, and the effect of the light wavelength used during examinations. METHODS: In the prospective study, subjective and objective refractions of 128 eyes of 64 patients were examined 3 months after implantation of the EDOF IOLs (ZXR00V, Johnson & Johnson Surgival Vision). Objective refractions were measured using an autorefractor with a near-infrared (NIR) light source. Clinical differences in the spherical, cylindrical and spherical equivalent (SE) refractions between the subjective and objective refractions were evaluated. Then, lens powers of monofocal, EDOF and diffractive bifocal IOLs in the use of a 850-nm light source were measured experimentally for using a lensmeter, and the differences from the monofocal IOLs were calculated. RESULTS: The mean objective refractions were more myopic (p < 0.001) than the subjective refractions; the differences in the spherical, cylindrical and SE refractions were -0.71, -0.26 and -0.84 dioptre, respectively. Experimental investigation resulted that there was the mean difference of 0.83 D with the EDOF from monofocal IOLs at 850 nm, while the difference was -0.20 D with bifocal IOLs. CONCLUSIONS: The diffractive EDOF IOLs using echelette gratings inherently induced constant differences in the subjective and objective refractions, which arose from the chromatic difference in IOL powers for the visible and NIR lights.


Assuntos
Implante de Lente Intraocular/métodos , Lentes Intraoculares , Óptica e Fotônica , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual , Idoso , Idoso de 80 Anos ou mais , Percepção de Profundidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese
17.
Clin Ophthalmol ; 15: 4141-4152, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34703200

RESUMO

PURPOSE: Halos are a chief source of patient dissatisfaction after multifocal intraocular lens (IOL) implantation. The primary purpose of this study was to investigate the influence of age, postoperative refraction, and pre- and postoperative pupil size on postoperative halo size with a trifocal diffractive IOL (AcrySof IQ PanOptix) and extended depth-of-focus (EDOF) IOL (TECNIS Symfony) to determine whether these factors could predict postoperative halo size. PATIENTS AND METHODS: This single-center, open-label study conducted between October 2018 and April 2020 in Yokosuka, Japan included 160 patients: 80 with PanOptix and 80 with Symfony IOLs. Size and intensity of the halos were examined binocularly using a computer-based simulator (Eyeland Design Network GmbH) and scored from 0 (minimum) to 10 (maximum) at 1, 3, and 6 months postoperatively, along with the change in each variable for both IOLs. The respective correlations of halo size with age, postoperative refraction, pre- and postoperative pupil size, and discomfort level due to the halo were also investigated 6 months postoperatively. RESULTS: Halo size and intensity were significantly mitigated between 1, 3, and 6 months postoperatively. Throughout the observation period, halo size was significantly larger with PanOptix than with Symphony (P < 0.05), and halo intensity was significantly higher with Symphony than with PanOptix (P < 0.05). The pre- and postoperative pupil size correlated positively with halo size, while age and postoperative refraction were negatively correlated, for both IOLs. CONCLUSION: Understanding the features and predictive preoperative factors of halos in different types of multifocal IOLs may be useful in improving patient satisfaction.

18.
Taiwan J Ophthalmol ; 9(1): 4-17, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30993062

RESUMO

The continued development of intraocular lens (IOL) technology has led to a dramatic improvement in refractive outcomes. New and innovative ways of achieving the desired postoperative refractive goals continue to be developed. This article aims to review the currently available IOL modalities for correction of presbyopia at the time of cataract surgery, including reference to high-quality comparative studies, where available, and discussion of strengths as well as limitations of the currently available IOL technologies. It has been shown that multifocal compared to monofocal IOL was associated with higher rates of spectacle independence, but higher rates and severity of symptomatic glare as well as reduced contrast sensitivity. Within multifocal IOLs, diffractive compared to refractive IOLs tended to have better near vision and a lower rate of symptomatic glare. Extended depth-of-focus IOLs compared to diffractive multifocal IOL demonstrated equal or superior intermediate visual acuity, with less than or equal rates of glare. Accommodative IOLs represent a broad range of technologies that continue to develop, and new technologies offering opportunities for postoperative adjustment of refractive outcome are emerging.

SELEÇÃO DE REFERÊNCIAS