Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Lasers Surg Med ; 56(4): 382-391, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38570914

RESUMO

BACKGROUND AND OBJECTIVES: Femtosecond laser trabeculotomy (FLT) creates aqueous humor outflow channels through the trabecular meshwork (TM) and is an emerging noninvasive treatment for open-angle glaucoma. The purpose of this study is to investigate the effect of pulse energy on outflow channel creation during FLT. MATERIALS AND METHODS: An FLT laser (ViaLase Inc.) was used to create outflow channels through the TM (500 µm wide by 200 µm high) in human cadaver eyes using pulse energies of 10, 15, and 20 µJ. Following treatment, tissues were fixed in 4% paraformaldehyde. The channels were imaged using optical coherence tomography (OCT) and assessed as full thickness, partial thickness, or not observable. RESULTS: Pulse energies of 15 and 20 µJ had a 100% success rate in creating full-thickness FLT channels as imaged by OCT. A pulse energy of 10 µJ resulted in no channels (n = 6), a partial-thickness channel (n = 2), and a full-thickness FLT channel (n = 2). There was a statistically significant difference in cutting widths between the 10 and 15 µJ groups (p < 0.0001), as well as between the 10 and 20 µJ groups (p < 0.0001). However, there was no statistically significant difference between the 15 and 20 µJ groups (p = 0.416). CONCLUSIONS: Fifteen microjoules is an adequate pulse energy to reliably create aqueous humor outflow channels during FLT in human cadaver eyes. OCT is a valuable tool when evaluating FLT.


Assuntos
Glaucoma de Ângulo Aberto , Trabeculectomia , Humanos , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Lasers , Cadáver
2.
Ophthalmol Sci ; 3(4): 100313, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37363134

RESUMO

Purpose: Pilot study to evaluate adverse events and intraocular pressure (IOP)-lowering of a novel, noninvasive glaucoma procedure, femtosecond laser, image-guided, high-precision trabeculotomy (FLIGHT). Design: Prospective, nonrandomized, single-center, interventional, single-arm clinical trial. Participants: Eighteen eyes from 12 patients with open-angle glaucoma. Methods: Eighteen eyes from 12 patients underwent FLIGHT, creating a single channel measuring 500-µm wide by 200-µm high through the trabecular meshwork and into Schlemm's canal. Adverse events, IOP, and other parameters were evaluated out to 24 months. Main Outcome Measures: Outcomes were the rates and types of adverse events and the rate of postprocedure best-corrected visual acuity loss (≥ 2 lines) compared with baseline. Efficacy outcomes were reduction in mean intraocular pressure (IOP) with respect to baseline and the percentage of eyes with a ≥ 20% reduction in IOP. Results: Eighteen eyes from 12 patients were enrolled in the study; 11 patients (17 eyes) returned at 24 months. There were no serious adverse events related to the laser treatment. Well-defined channels were clearly visible at 24 months by gonioscopy and anterior segment OCT, with no evidence of closure. At 24 months, the mean IOP was reduced by 34.6% from 22.3 ± 5.5 to 14.5 ± 2.6 mmHg (P < 5e-5), with an average of 2.0 ± 1.2 hypotensive medications compared with 2.2 ± 1.1 at baseline (P = 0.22). Fourteen out of the 17 study eyes (82.3%) achieved a ≥ 20% reduction in IOP at 24 months when compared with baseline. Conclusion: The FLIGHT system demonstrated a favorable safety profile in this initial pilot study, with no device-related serious adverse events. The channels appeared patent at 24 months, indicating medium-term durability. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA