Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Thromb J ; 19(1): 72, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34654442

RESUMO

The antithrombotic effect of vitamin K antagonists (VKA) depends on controlled lowering of the activity of factors (F) II and X whereas reductions in FVII and FIX play little role. PT-INR based monitoring, however, is highly influenced by FVII, which has the shortest half-life of vitamin K-dependent coagulation factors. Hence, variability in the anticoagulant effect of VKA may be partly secondary to an inherent flaw of the traditional monitoring test itself. The Fiix prothrombin time (Fiix-PT) is a novel test that is only sensitive to reductions in FII and FX and is intended to stabilize the VKA effect. Two clinical studies have now demonstrated that when warfarin is monitored with the Fiix-PT based normalized ratio (Fiix-NR) instead of PT-INR, anticoagulation is stabilized and less testing and fewer dose adjustments are needed. Furthermore, the relative risk of thromboembolism was reduced by 50-56% in these studies without an increase in major bleeding.

2.
J Thromb Thrombolysis ; 43(4): 550-561, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28214948

RESUMO

Fiix-prothrombin time (Fiix-PT) differs from traditional PT in being affected by reduced factor (F) II or FX only. In the randomized controlled Fiix-trial, patients on warfarin monitored with Fiix-PT (Fiix-warfarin patients) had fewer thromboembolisms (TE), similar major bleeding (MB) and more stable anticoagulation than patients monitored with PT (PT-warfarin patients). In the current Fiix-trial report we analyzed how reduced anticoagulation variability during Fiix-PT monitoring was reflected in patients with TE or bleeding. Data from 1143 randomized patients was used. We analyzed the groups for anticoagulation intensity (time within target range; TTR), international normalized ratio (INR) variability (variance growth rate B1; VGR) and dose adjustment frequency. We assessed how these parameters associated with clinically relevant vascular events (CRVE), ie TE or MB or clinically relevant non-MB. TTR was highest in Fiix-warfarin patients without CRVE (median 82%;IQR 72-91) and lowest in PT-warfarin patients with TE (62%;56-81). VGR was lowest in Fiix-warfarin patients without CRVE (median VGR B1 0.17; 95% CI 0.08-0.38) and with TE (0.20;0.07-0.26) and highest in PT-warfarin patients with TE (0.50;0.27-0.90) or MB (0.59;0.07-1.36). The mean annual dose adjustment frequency was lowest in Fiix-warfarin patients with TE (mean 5.4;95% CI 3.9-7.3) and without CRVE (mean 6.0; 5.8-6.2) and highest in PT-warfarin patients with TE (14.2;12.2-16.3). Frequent dose changes predicted MB in both study arms. Compared to patients monitored with PT, high anticoagulation stability in Fiix-warfarin patients coincided with their low TE rate. Those with bleeding had high variability irrespective of monitoring method. Thus, although further improvements are needed to reduce bleeding, stabilization of anticoagulation by Fiix-PT monitoring associates with reduced TE.


Assuntos
Anticoagulantes/administração & dosagem , Monitoramento de Medicamentos/métodos , Tempo de Protrombina , Tromboembolia/tratamento farmacológico , Varfarina/administração & dosagem , Fator X/farmacologia , Feminino , Hemorragia/induzido quimicamente , Humanos , Coeficiente Internacional Normatizado , Masculino , Protrombina/farmacologia , Tromboembolia/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA