Thin Solid Films ; 7882024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38343423

RESUMO

The present study aimed to investigate the feasibility of using acoustic emission (AE) as a detection method for identifying failure mechanisms at the modular junction interface in total hip replacements (THRs) subjected to fretting corrosion. The experimental setup involved simulating fretting corrosion using a Ti6Al4V disc representing the femoral neck and a ZrO2 pin representing the femoral head. Mechanical testing provided insights into the wear and frictional behavior occurring at the modular junction interface. The results revealed that for all three potential conditions, a fretting condition of partial slip was observed. These findings highlight the importance of understanding the mechanical interactions and their influence on the overall performance and longevity of THRs. Electrochemical analysis shed light on the corrosion behavior under different potentiostatic conditions. High potentials in the anodic condition led to increased corrosion and ion transfer due to the breakdown of the passive oxide layer. Conversely, the cathodic potential condition exhibited a regrowth of the passive oxide layer, protecting the Ti6Al4V surface from further corrosion. The mid-range corrosion potential condition showed a dynamic equilibrium between corrosion and passivation processes. These electrochemical insights enhance our understanding of the mechanisms involved in fretting corrosion. The AE data proved to be promising in detecting and monitoring the onset and progression of failure mechanisms. The AE signals exhibited distinctive patterns that correlated with the severity of fretting corrosion. Notably, the hit driven data results, derived from AE signals, demonstrated the ability to differentiate between different levels of fretting conditions. This suggests that AE can serve as a valuable diagnostic tool for early detection and continuous monitoring of implant failure in THRs.

2.
Medicina (Kaunas) ; 60(3)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38541184

RESUMO

Background and objectives: wear and corrosion can lead to the gross failure of the Morse taper junction with the consequent fracture of the true neck of the prosthetic stem in hip arthroplasty. Materials and Methods: 58-year-old male patient, with a BMI of 38 kg/m2. Because of avascular necrosis, in 2007, a metal-on-metal total hip arthroplasty was implanted in him, with a TMZF stem and a Co-Cr head. In December 2020, he complained of acute left hip pain associated with the deterioration of his left leg and total functional impairment, preceded by the crunching of the hip. X-rays and CT scan showed a fracture of the prosthetic neck that necessitated prosthetic revision surgery. A Scanning Electron Microscope (SEM) analysis of the retrieved prosthetic components was conducted. Results: Macroscopically, the trunnion showed a typical bird beak appearance, due to a massive material loss of about half of its volume. The gross material loss apparently due to abrasion extended beyond the trunnion to the point of failure on the true neck about half a centimeter distal from the taper. SEM analysis demonstrated fatigue rupture modes, and the crack began close to the neck's surface. On the lateral surface, several scratches were found, suggesting an intense wear that could be due to abrasion. Conclusions: The analysis we conducted on the explanted THA showed a ductile rupture, began close to the upper surface of the prosthetic neck where the presence of many scratches had concentrated stresses and led to a fatigue fracture.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Microscopia Eletrônica de Varredura , Falha de Prótese , Desenho de Prótese
3.
J Arthroplasty ; 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38070717

RESUMO

BACKGROUND: Extensive research has reported on fretting corrosion and material loss for a variety of metal taper interfaces in orthopedic devices. For modular acetabular shell-liner constructs, the interfaces studied thus far have consisted of mixed-metal pairings, and the risk of fretting corrosion and material loss for the all-titanium (Ti) shell-liner taper junction in one ceramic-on-ceramic (COC) design remains poorly understood. We asked: do Ti shell-liner taper interfaces in COC total hip arthroplasty devices show in vivo evidence of (1) fretting and/or corrosion, and (2) quantifiable potential material loss? METHODS: We examined 22 shell-liner pairs and 22 single liners from retrieved COC components. The taper interface surfaces were assessed for fretting corrosion using a semiquantitative scoring method and imaged with scanning electron microscopy. A subcohort of components was measured with a coordinate measuring machine, and volumetric material loss and maximum wear depth were calculated. RESULTS: Fretting corrosion at the taper interfaces was minimal to mild for 95% of liners and 100% of shells. Imaging revealed fretting marks within a band of corrosion on some implants and evidence of corrosion not in the proximity of mechanical damage. Estimated material loss ranged from 0.2 to 1.3 mm3 for liners, and 0.5 to 1.1 mm3 for shells. Maximum wear depth for all components was 0.03 mm or less. CONCLUSIONS: Our results indicate that, compared to other taper junctions in total joint arthroplasty, the risk of corrosion and material loss may be minimal for Ti shell-liner interfaces.

4.
Arch Orthop Trauma Surg ; 143(6): 3649-3657, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36178493

RESUMO

INTRODUCTION: Breakage of exchangeable-neck (EN) and adverse local tissue reactions (ALTRs) to neck-stem junction (NSJ) damage products are responsible for increasing the revision rate of EN hip prostheses. We investigated the survivorship of an EN hip prosthesis including a NSJ with both components made of titanium alloy (Ti-alloy/Ti-alloy) to assess whether, and to what extent, EN breakage and NSJ damage affected implant survivorship. MATERIALS AND METHODS: Using data from a hip replacement registry, we determined survivorship of 2857 EN prostheses. Long-offset configurations of head and EN were implanted in heavy (> 90 kg) patients only in 23 hips. We investigated under which conditions EN breakages or ALTRs occurred. We also measured titanium (Ti) and vanadium (V) blood concentrations in 24 patients with a unilateral well-working prosthesis. RESULTS: The 17-year survival rates for any reason and aseptic loosening of any component were 88.9% (95%CI 87.5-90.1; 857 hips at risk) and 96.9% (95%CI 96.0-97.6), respectively. There were two cases of EN breakage and one case of ALTR (metallosis), due to rim-neck impingement, out of 276 revisions. After an average period of 9.8 years (range 7.8-12.8 years), the maximum Ti and V blood concentrations in patients with a well-working prosthesis were 5.0 µg/l and 0.16 µg/l, respectively. CONCLUSION: The present incidence of EN breakage or ALTR is lower than those reported in other studies evaluating EN hip prosthesis survivorship. This study suggests that (i) the risk of EN breakage is reduced by limiting the use of long-offset configurations in heavy patients and (ii) Ti-alloy/Ti-alloy NSJ damage products do not promote ALTR nor significantly alter the rate of implant loosening. Since design decisions and implant configuration determine the NSJ strength, the NSJ strength in working conditions must be thoroughly investigated to proper define the clinical indications for any EN design.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Prótese de Quadril/efeitos adversos , Ligas , Titânio , Sobrevivência , Desenho de Prótese , Artroplastia de Quadril/efeitos adversos , Falha de Prótese , Reoperação/efeitos adversos
5.
J Arthroplasty ; 36(7S): S80-S87, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33610405

RESUMO

BACKGROUND: Dual mobility (DM) articulations were introduced for total hip arthroplasty to reduce the risk of instability for patients who have a high risk of dislocation. The use of DM constructs in both primary and revision total hip arthroplasty has been steadily increasing, leading to concerns regarding potential risks of fretting corrosion, polyethylene wear, metal release, and failure due to component positioning. METHODS: A total of 56 retrieved DM constructs were collected. The inner and outer polyethylene liner surfaces were assessed for 7 damage mechanisms, and fretting corrosion was evaluated for the femoral stem, head, and modular liner. Three polyethylene liners with the greatest amounts of embedded debris were examined using scanning electron microscopy. Energy-dispersive X-ray spectroscopy was used to determine the elemental content of the debris. Acetabular cup orientation was analyzed radiographically using the EBRA (Einzel-Bild-Roentgen-Analyse) method. RESULTS: The devices were revised most frequently for infection (36%), loosening (21%), and instability/dislocation (18%). The most common polyethylene damage mechanisms were scratching, pitting, burnishing, and embedded debris, and no difference in total damage was found between primary and revision cases. Scanning electron microscopy/energy-dispersive X-ray spectroscopy revealed that debris morphology and composition were consistent with porous titanium coating, resulting from cup loosening or broken screws and augments. A total of 71% and 50% of the constructs were determined to be within the Lewinnek safe zone for inclination and anteversion, respectively. CONCLUSION: The most notable mechanisms of surface damage were due to third-body debris, especially for the polyethylene surfaces which articulate against cobalt-chromium femoral heads and acetabular liners. Scratching of the femoral head and the metal liner from this debris may support the clinical use of ceramic for DM bearing surfaces in the future.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Corrosão , Prótese de Quadril/efeitos adversos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese
6.
J Arthroplasty ; 35(6S): S294-S298, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32197964

RESUMO

BACKGROUND: Modular dual-mobility (MDM) total hip arthroplasty (THA) is designed with a cobalt-chromium liner inserted into a titanium acetabular component. The purpose of this study is to investigate the potential risks for fretting corrosion at this junction, by measuring serum metal ions, after MDM acetabular revision. METHODS: Thirty-seven patients with well-functioning revision THAs participated in a cross-sectional study at mean 5.1 (2-10) years after surgery. All received a trabecular titanium MDM acetabular component. The serum levels of cobalt and chromium were measured using mass spectrometry. RESULTS: The mean values of chromium and cobalt were 2.08 µg/L (95% confidence interval 0.9-3.2, range 0.02-11.8) and 1.99 µg/L (95% confidence interval 0.81-3.17, range 0.07-16.05), respectively. Eleven patients (29, 7%) had ion levels above the normal range, with 6 (16.2%) above 5 µg/L and 5 (13.5%) between 1 and 5 µg/L. A significant correlation was found between an elevated serum metal ion level and University of California Los Angeles score (P = .016). CONCLUSION: We conclude that serum metal level elevation may occur secondary to metal debris resulting from corrosion of the index MDM THA. This potential risk should be included in the decision-making process when dealing with revision arthroplasty in young and active patients.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Estudos Transversais , Prótese de Quadril/efeitos adversos , Humanos , Íons , Los Angeles , Desenho de Prótese , Falha de Prótese
7.
J Arthroplasty ; 34(1): 157-162, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30318251

RESUMO

BACKGROUND: Total hip arthroplasty is performed with modular parts. Either a metal or ceramic ball is fastened to the trunnion of a femoral stem via a Morse taper. This implant scenario has been successful. However, recently larger (36 mm or greater) metal heads have become more popular as a means to reduce the incidence of hip joint dislocation. Today, a number of clinical failures have occurred due to mechanically assisted crevice corrosion at the head (taper) stem (trunnion) interface necessitating revision surgery. The objective of this research is to investigate how trunnion stress varies with head size, and how taper-trunnion geometric parameters including horizontal lever arm (HLA), taper engagement level, and a new parameter called trunnion load offset affect trunnion stresses. We hypothesized that trunnion stress may increase with increasing head size and HLA. METHODS: This hypothesis was tested by conducting finite element analysis of a titanium hip stem and 4 commercially available cobalt-chromium femoral heads subjected to 4 different moderate to severe physiological loading conditions. RESULTS: Results showed that trunnion stress increases with increasing head size, increased HLA, and trunnion load offset. It was also found that under certain load cases the trunnion stresses get exceptionally high, especially for the larger head sizes. CONCLUSION: This study suggests trying to avoid larger femoral head sizes that may result in higher implant stresses under certain loading conditions.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese/efeitos adversos , Falha de Prótese/etiologia , Artroplastia de Quadril/instrumentação , Materiais Biocompatíveis/efeitos adversos , Ligas de Cromo/efeitos adversos , Corrosão , Fêmur/cirurgia , Cabeça do Fêmur/cirurgia , Análise de Elementos Finitos , Humanos , Masculino , Reoperação , Estresse Mecânico , Estresse Fisiológico , Titânio/efeitos adversos
8.
J Arthroplasty ; 33(6): 1953-1961, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29486910

RESUMO

BACKGROUND: Mechanically assisted crevice corrosion of modular tapers continues to be a concern in total joint arthroplasties. A surgical factor that may affect taper fretting corrosion during cyclic loading is seating load magnitude. In this study, modular head-neck taper junctions were seated, capturing load-displacement, over a range of axially oriented loads, and electrochemical and micromotion data were captured during short-term incremental cyclic fretting corrosion (ICFC) tests. The hypothesis is low seating loads result in greater motion and fretting corrosion in ICFC tests. The effect of assembly load on pull-off force post-ICFC testing was also evaluated. METHODS: The study employed custom-built test fixtures which measured head-neck micromotion and an electrochemical chamber to monitor electrochemical reactions. Head-neck motion measurements were captured using 2 noncontact differential variable reluctance transducers mounted to the head. Seating experiments ranged from 1000 to 8000 N. RESULTS: Significant differences due to seating loads were reported in seating displacement, ICFC subsidence, and fretting current at 4000 N cyclic load. Seating load decreased but did not eliminate currents. Fretting onset load remained fixed (approximately 1200 N) for tapers seated above 2000 N. Fretting subsidence was negligible for seating loads of 4000 N or higher, and increased subsidence was observed below 4000 N. CONCLUSION: This short-term test method evaluated the acute performance of modular implants which were assembled under various loads and demonstrated the link between seating loads, fretting motions, and electrochemical reactions. While increased seating loads reduced fretting corrosion and taper subsidence, it did not prevent fretting corrosion even at 8 kN seating.


Assuntos
Artroplastia de Quadril/instrumentação , Corrosão , Prótese de Quadril , Teste de Materiais , Ligas , Artroplastia de Quadril/efeitos adversos , Eletroquímica , Humanos , Fenômenos Mecânicos , Movimento , Desenho de Prótese , Falha de Prótese , Estresse Mecânico , Propriedades de Superfície
9.
J Arthroplasty ; 32(9): 2887-2891, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28668212

RESUMO

BACKGROUND: During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In vitro testing suggests that corrosion is not a concern in sleeved ceramic heads; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties. METHODS: Thirty-seven sleeved ceramic heads were collected during revision. The femoral heads and sleeves were implanted 0.0-3.3 years. The implants were revised predominantly for instability, infection, and loosening. Fifty percent of the retrievals were implanted during a primary surgery. Fretting corrosion was assessed using the Goldberg-Higgs semiquantitative scoring system. RESULTS: Mild-to-moderate fretting corrosion scores (score = 2-3) were observed in 92% of internal tapers, 19% of external tapers, and 78% of the stems. Severe fretting corrosion was observed in 1 stem trunnion that was previously retained during revision surgery and none of the retrieved sleeves. There was no difference in corrosion damage of sleeves used in primary or revision surgery. CONCLUSION: The fretting corrosion scores in this study were predominantly mild and lower than reported fretting scores of cobalt-chrome heads in metal-on-polyethylene bearings. Although intended for use in revisions, we found that the short-term in vivo corrosion behavior of the sleeves was similar in both primary and revision surgery applications. From an in vivo corrosion perspective, sleeves are a reasonable solution for restoring the stem taper during revision surgery.


Assuntos
Artroplastia de Quadril , Cerâmica , Ligas de Cromo/química , Falha de Prótese , Idoso , Corrosão , Fêmur/cirurgia , Cabeça do Fêmur/cirurgia , Prótese de Quadril , Humanos , Pessoa de Meia-Idade , Ortopedia , Polietileno , Desenho de Prótese , Reoperação , Software , Titânio/química
10.
J Arthroplasty ; 31(12): 2900-2906, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27426028

RESUMO

BACKGROUND: Metal debris and ion release has raised concerns in joint arthroplasty. The purpose of this study was to characterize the sources of metallic ions and particulate debris released from long-term (in vivo >15 years) total knee arthroplasty femoral components. METHODS: A total of 52 CoCr femoral condyles were identified as having been implanted for more than 15 years. The femoral components were examined for incidence of 5 types of damage (metal-on-metal wear due to historical polyethylene insert failure, mechanically assisted crevice corrosion at taper interfaces, cement interface corrosion, third-body abrasive wear, and inflammatory cell-induced corrosion [ICIC]). Third-body abrasive wear was evaluated using the Hood method for polyethylene components and a similar method quantifying surface damage of the femoral condyle was used. The total area damaged by ICIC was quantified using digital photogrammetry. RESULTS: Surface damage associated with corrosion and/or CoCr debris release was identified in 51 (98%) CoCr femoral components. Five types of damage were identified: 98% of femoral components exhibited third-body abrasive wear (mostly observed as scratching, n = 51/52), 29% of femoral components exhibited ICIC damage (n = 15/52), 41% exhibited cement interface damage (n = 11/27), 17% exhibited metal-on-metal wear after wear-through of the polyethylene insert (n = 9/52), and 50% of the modular femoral components exhibited mechanically assisted crevice corrosion taper damage (n = 2/4). The total ICIC-damaged area was an average of 0.11 ± 0.12 mm2 (range: 0.01-0.46 mm2). CONCLUSION: Although implant damage in total knee arthroplasty is typically reported with regard to the polyethylene insert, the results of this study demonstrate that abrasive and corrosive damage occurs on the CoCr femoral condyle in vivo.


Assuntos
Artroplastia do Joelho/instrumentação , Cromo , Cobalto , Prótese do Joelho/efeitos adversos , Falha de Prótese/etiologia , Adulto , Idoso , Corrosão , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Polietileno , Desenho de Prótese , Adulto Jovem
11.
J Arthroplasty ; 31(1): 186-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26318084

RESUMO

Dual mobility acetabular components can reduce the incidence of total hip arthroplasty (THA) instability. Modular dual mobility (MDM) components facilitate acetabular component implantation. However, corrosion can occur at modular junctions. Serum cobalt and chromium levels and Oxford scores were obtained at minimum two year follow-up for 100 consecutive patients who had THA with MDM components. Average Oxford score was 43 (range 13-48). Average serum cobalt and chromium values were 0.7 mcg/L (range, 0.0 to 7.0) and 0.6 mcg/L (range, 0.1 to 2.7), respectively. MARS MRI was performed for four patients with pain and elevated serum cobalt levels. Two of these studies were consistent with adverse local tissue reaction. We recommend use of MDM implants in only patients at high risk for dislocation following THA.


Assuntos
Artroplastia de Quadril/instrumentação , Cromo/sangue , Cobalto/sangue , Prótese de Quadril/efeitos adversos , Acetábulo , Adulto , Idoso , Corrosão , Feminino , Seguimentos , Humanos , Incidência , Masculino , Metais , Pessoa de Meia-Idade , Dor/etiologia
12.
Tribol Int ; 91: 235-245, 2015 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-26405372

RESUMO

Modern hip prostheses feature a modular implant design with at least one tapered junction. This design can lead to several complications due to the introduction of additional interfaces, which are subjected to various loading conditions and micromotion. The main objective of current study is to develop a fretting corrosion apparatus, which is able characterize the mechanical and electrochemical behaviour of various existing metal alloy couples during fretting motion. This study describes the design and the main considerations during the development of a novel fretting corrosion apparatus, as well as determination of the machine compliance and the initial testing results. Machine compliance considerations and frictional interactions of the couples are discussed in detail. For the preliminary tests, metal alloy pins, made of Ti6Al4V and wrought high-carbon CoCrMo were mechanically polished to a surface roughness of less than 20nm. 2 pins (Diameter = 11mm) of either Ti6Al4V or CoCrMo were loaded onto a Ti6Al4V alloy rod at a normal force of 200N. The interface types included: Ti6Al4V-Ti6Al4V-Ti6Al4V, Ti6Al4V-Ti6Al4V-CoCrMo, and CoCrMo-Ti6Al4V-CoCrMo. The Ti6Al4V rod articulated against the metal alloy pins in a sinusoidal fretting motion with a displacement amplitude of ±50µm. Bovine calf serum (30g/L of protein content) was selected as a lubricant and tested at 2 different pH levels (pH 3.0 and 7.6). In all cases, current and friction energy were monitored during the fretting process. The results indicated distinct, material-specific current evolutions and friction energies. No significant differences were observed in electrochemical or mechanical behaviour in response to pH change. In general, Ti6Al4V-Ti6Al4V-Ti6Al4V couples displayed the earliest passivation and superior electrochemical behaviour compared to Ti6Al4V-Ti6Al4V-CoCrMo and CoCrMo-Ti6Al4V-CoCrMo under fretting conditions. In addition, fluctuations in current were observed in specific regions at all instances where Ti6Al4V was coupled with Ti6Al4V. These fluctuations were not observed in instances where Ti6Al4V was coupled with CoCrMo. These findings suggest transitions in the degradation mechanisms at the modular junction as a function of material couples/contacts. The findings may assist in improving the current hip modular junctions.

13.
Dent Mater ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39174418

RESUMO

OBJECTIVE: Implant treatment is provided to individuals with normal, idealized masticatory forces and also to patients with parafunctional habits such as grinding, clenching, and bruxing. Dental erosion is a common increasing condition and is reported to affect 32 % of adults, increasing with age. This oral environment is conducive to tribocorrosion and the potential loss of materials from the implant surfaces and interfaces with prosthetic components. Although several fretting-corrosion studies have been reported, until now, no study has simulated clinically relevant micromotion. Therefore, our aim is to investigate fretting-corrosion using our new micro-fretting corrosion system, simulating clinical conditions with 5 µm motion at the implant-abutment interface under various occlusal loads and acidic exposures. METHODS: We simulated four conditions in an oral environment by varying the contact load (83 N and 233 N) and pH levels (3 and 6.5). The commonly used dental implant material, Grade IV titanium, and abutment material Zirconia (ZrO2)/ Grade IV titanium were selected as testing couple materials. Artificial saliva was employed to represent an oral environment. In addition, a standard tribocorrosion protocol was followed, and the pin was controlled to oscillate on the disk with an amplitude of 5 µm during the mastication stage. After the testing, 3D profilometry and scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS) were utilized to analyze the worn surfaces. Inductively coupled plasma mass spectrometry (ICP-MS) was also used to measure the metal ion release. RESULTS: Energy ratios were below 0.2, indicating a fretting regime of partial slip for all groups. Open-circuit potential (OCP) and electrochemical impedance spectroscopy (EIS) were analyzed to compare the electrochemical behavior among groups. As a result, corrosive damage was observed to be more in the Ti4- Ti4 groups than in Zr-Ti4 ones, whereas more mechanical damage was found in the Zr-Ti4 groups than in the Ti4-Ti4 groups. Possible mechanisms were proposed in the discussion to explain these findings. SIGNIFICANCE: The results observed from this study might be helpful to clinicians with implant selection. For example, for patients with bruxism, a titanium implant paired with a titanium abutment may be preferable, while patients with GERD may benefit more from a titanium implant paired with a zirconia abutment.

14.
J Mech Behav Biomed Mater ; 150: 106326, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38141361

RESUMO

Implant modularity within revision total hip arthroplasty (THA) offers multiple implant configurations and allows surgeons a high intraoperative flexibility to restore functionality to the patients joint, even in complex revision cases. However, a rare but devastating complication for patients, clinicians and manufacturers presenting a breakage of the taper junction between the distal stem and the proximal implant part. Aside from implant and patient specific risk factors, corrosion and fretting at the stem junctions have been associated with taper failure. Whether corrosive processes are a precursor of failure or rather an accompaniment of material fatigue is thereby still unclear. Therefore, this study aims to investigate the incidence of taper corrosion in a collection of 17 retrievals from a single type (MRP-Titan, Peter Brehm GmbH) and on the correlation of taper corrosion to implant and patient specific factors. None of the implants was revised for problems related to the taper junction, corrosion or the implant itself. The modular stem junction of all retrievals was visually rated with respect to corrosion, fretting and surface contamination. Additionally, the stability of taper junctions of retrievals where the proximal part with the neck was still assembled to the stem was determined by measuring the loosening moment of the securing screw and the push-out-force for taper dissociation. There was no difference between the mean push-out-force of the retrievals (14 kN ± 1.2 kN) and new reference samples (12.6 kN ± 0.5 kN). Approximately one third of the investigated retrievals showed considerable taper corrosion. The extent of corrosion increased with time in vivo and contamination of the neck piece, while it decreased with the loosening moment of the locking screw. The parameters femoral head offset, neck piece length, lateralized neck pieces, obesity of patients and septic/aseptic revision were not correlated to taper corrosion. Taper corrosion seems to occur regularly in modular taper junctions and is not necessarily connected to taper failure. A correct assembly of the junction and avoiding taper surface contamination during revision surgery is mandatory.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Prótese de Quadril/efeitos adversos , Corrosão , Desenho de Prótese , Reoperação , Falha de Prótese
15.
Materials (Basel) ; 17(12)2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38930319

RESUMO

The nickel-based alloy Inconel 600, strengthened by solution treatment, finds extensive application as a heat exchange pipe material in steam generators within nuclear power plants, owing to its exceptional resistance to high-temperature corrosion. However, fretting corrosion occurs at the contact points between the pipe and support frame due to gas-liquid flow, leading to wear damage. This study investigates the fretting wear behavior and damage mechanism of the nickel-based alloy Inconel 600 and 304 stainless steel friction pairs under point contact conditions in a water environment. Characterization was performed using laser confocal scanning microscopy and scanning electron microscopy equipped with energy-dispersive spectroscopy. Results indicate that the friction coefficient remains consistent across different chloride ion concentrations, while the wear volume increases with increasing chloride concentrations. Notably, friction coefficient oscillations are observed in the gross slip regime (GSR). Moreover, the stability of the oxide layer formed in water is compromised, diminishing its protective effect against wear. In the partial slip regime (PSR), friction coefficient oscillations are absent. An oxide layer forms within the wear scar, with significantly fewer cracks compared to those within the oxide layer in the GSR. It is worth noting that in GSR, the friction coefficient oscillates.

16.
J Funct Biomater ; 15(4)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38667567

RESUMO

Modular artificial hip joints are a clinical standard today. However, the release of wear products from the head-taper interface, which includes wear particles in the nm size range, as well as metal ions, have raised concerns. Depending on the loading of such taper joints, a wide variety of different mechanisms have been found by retrieval analyses. From these, this paper concentrates on analyzing the contribution of gross slip fretting corrosion at ultra-mild wear rates using a bovine calf serum solution (BCS) as the lubricant. The parameters were chosen based on biomechanical considerations, producing wear rates of some ng/m wear path. In parallel, the evolution of tribomaterial (third bodies) was analyzed as to its constituents and generation rates. It has already been shown earlier that, by an advantageous combination of wear mechanisms and submechanisms, certain constituents of the tribomaterial remain inside the contact area and act like extreme-pressure lubricant additives. For the known wear and corrosion resistance of austenitic high-nitrogen steels (AHNSs), which outperform CoCrMo alloys even under inflammatory conditions, we hypothesized that such steels will generate ultra-mild wear rates under gross slip fretting. While testing AHNSs against commercially available biomedical-grade materials of CoCrMo and TiAlV alloys, as well as zirconia-toughened alumina (ZTA) and against itself, it was found that AHNSs in combination with a Ti6Al4V alloy generated the smallest wear rate under gross slip fretting corrosion. This paper then discusses the wear behavior on the basis of ex situ analyses of the worn surfaces as to the acting wear mechanisms and submechanisms, as well as to the tribological reaction products.

17.
Res Sq ; 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37886457

RESUMO

Fretting-corrosion is one of the failure processes in many applications, including biomedical implants. For example, the modern design of hip implants with multiple components offers better flexibility and inventory storage. However, it will trigger the fretting at the implant interfaces with a small displacement amplitude (< 5 µm) and usually in a partial slip region. Although many studies have been reported on the fretting, they have high displacement amplitude and are in the gross slip region. It is imperative to have an apparatus to overcome such limitations, specifically for hip implant applications. Therefore, this study describes the development of a fretting-corrosion apparatus with low micro-motion (≤ 5 µm) that can simultaneously monitor the corrosion process. Initial experiments with Ti6Al4V-Ti6Al4V in 0.9% saline, Ti6Al4V-Ti6Al4V in bovine calf serum (BCS), and ZrO2-Ti6Al4V in BCS were conducted to validate the system. As a result, the fretting regime of all groups remained partially slip region throughout the 3600 cycles, and the possible failure mechanisms are proposed in this manuscript.

18.
J Mech Behav Biomed Mater ; 146: 106074, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37591055

RESUMO

The composite fretting-corrosion damage due to combinations of radial, tangential, rotational, and other fretting causes local adverse tissue reactions and failure of artificial joints. Previous studies have mainly focused on the single fretting mode, while ignoring the coupled effects of multimode fretting. The fretting-corrosion mechanisms between the components are not yet fully understood. In this study, the tangential-radial composite fretting was realized by applying a normal alternating load to the tangential fretting. The composite fretting corrosion behavior of zirconia toughened alumina ceramic/Ti6Al4V alloy used for the head-neck interface of an artificial hip joint under simulated body fluid was investigated. The effects of displacement and alternating load amplitude were considered. The alternating load amplitude was given by the maximum normal load and minimum normal load ratio R. The results showed that the composite fretting damage mechanisms of this pair were mainly abrasion and tribocorrosion. Cracking also existed under large displacement. The effect of alternating load on fretting corrosion was found to be mainly caused by changes in the contact area and instantaneous contact state. In addition, the alternating load during the composite fretting promoted the formation of the three-body layer in the contact area. A decrease in load ratio caused fretting to change from gross to partial slip. In the case of small displacement, the load ratio had little effect on the friction work or wear scar profile. The corrosion rate of materials and the concentration of metal ions released into the solution increased as load ratio decreased. In cases of large and medium displacement, load ratio reduction increased the friction work and expanded the wear scar. The reduction in load ratio also caused the corrosion rate of the material to increase and then decrease, and the metal ion concentration decreased.


Assuntos
Líquidos Corporais , Cicatriz , Humanos , Corrosão , Ligas , Óxido de Alumínio
19.
J Orthop Res ; 41(8): 1738-1745, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36606423

RESUMO

Acetabular components (DePuy Pinnacle (A) and Stryker Trident (B), Ti-6Al-4V shells and CoCrMo liners) with varying geometries were assembled under a 4 kN seating load. Liner-displacement was recorded. Cyclic compression to 4 kN, R = 0.01, 9 Hz was applied for three million cycles to evaluate fretting corrosion currents (n = 5). Fretting currents, load-displacement, ion dissolution, and disassembly loads were used to compare device performance. Data were analyzed using ANOVA with Tukey post hoc comparisons (p < 0.05). Liner seating displacements were not significantly different between groups. Fretting currents averaged over the initial 10 h and over three million cycles were 0.17 µA (A) and 0.55 µA (B) and 0.05 µA (A) and 0.17 µA (B), respectively (p = 0.19). No variation in ion averages between A and B (0.23 and 0.45 ppm for Ti [p = 0.21], 0.63 and 0.85 ppm for Co [p = 0.47]) existed. Average push-out forces, -2.41 (A) and -2.42 kN (B), were not significantly different (p = 0.97). SEM and EDS showed some titanium and metal oxide transfer from the shell to the liner in both designs. Overall, both implant designs exhibited very minor MACC in these experiments. This study demonstrates quantitative measures of in vitro fretting corrosion over the course of three million cycles and the minimal degree of acetabular taper damage. Clinical Significance: Retrieval studies show dual mobility acetabular shell-liner tapers with metal-on-metal contacts are susceptible to fretting corrosion in vivo.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Corrosão , Desenho de Prótese , Metais , Falha de Prótese
20.
J Mech Behav Biomed Mater ; 142: 105860, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37127011

RESUMO

The fretting corrosion at the head-neck interface of artificial hip joints is an important reason for the failure of prostheses. The Ti6Al4V alloy-zirconia-toughened alumina (ZTA) ceramic combination has been widely used to make the head and neck of artificial hip joints. In this study, its fretting corrosion behavior in simulated body fluid was studied by electrochemical monitoring, surface morphology characterization, and chemical composition analysis. A running condition fretting map (RCFM) of load and displacement was established, including three regimes, namely partial slip regime (PSR), mixed fretting regime (MFR), and gross slip regime (GSR). The friction dissipation energy increased gradually from the PSR to MFR and GSR. In the PSR, the damage mechanisms were slight abrasive wear and tribocorrosion at the edge of contact area, as well as extremely slight adhesive wear at the center. In the MFR, the damage mechanisms were mainly adhesive wear, abrasive wear, and corrosive wear. In the GSR, the damage mechanism was serious abrasive wear, fatigue wear, and corrosive wear combined with slight adhesive wear. Finally, an ion-concentration map was created, displaying the material-loss transition of different displacements and loads. The material loss increased with the increased displacement, and increased first and then decreased with the increased load.


Assuntos
Artroplastia de Quadril , Líquidos Corporais , Cáusticos , Prótese de Quadril , Humanos , Corrosão , Óxido de Alumínio , Ligas , Falha de Prótese , Propriedades de Superfície , Desenho de Prótese