1.
Small ; 20(20): e2307129, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38126615

RESUMO

Organic luminescent materials are indispensable in optoelectronic displays and solid-state luminescence applications. Compared with single-component, multi-component crystalline materials can improve optoelectronic characteristics. This work forms a series of full-spectrum tunable luminescent charge-transfer (CT) cocrystals ranging from 400 to 800 nm through intermolecular collaborative self-assembly. What is even more interesting is that o-TCP-Cor(x)-Pe(1-x), p-TCP-Cor(x)-Pe(1-x), and o-TCP-AN(x)-TP(1-x) alloys are prepared based on cocrystals by doping strategies, which correspondingly achieve the stepless color change from blue (CIE [0.22, 0.44]) to green (CIE [0.16, 0.14]), from green (CIE [0.27, 0.56]) to orange (CIE [0.58, 0.42]), from yellow (CIE [0.40, 0.57]) to red (CIE [0.65, 0.35]). The work provides an efficient method for precisely synthesizing new luminescent organic semiconductor materials and lays a solid foundation for developing advanced organic solid-state displays.

2.
Cytometry A ; 105(3): 181-195, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37984809

RESUMO

Multiparameter flow cytometry (MFC) has emerged as a standard method for quantifying measurable residual disease (MRD) in acute myeloid leukemia. However, the limited number of available channels on conventional flow cytometers requires the division of a diagnostic sample into several tubes, restricting the number of cells and the complexity of immunophenotypes that can be analyzed. Full spectrum flow cytometers overcome this limitation by enabling the simultaneous use of up to 40 fluorescent markers. Here, we used this approach to develop a good laboratory practice-conform single-tube 19-color MRD detection assay that complies with recommendations of the European LeukemiaNet Flow-MRD Working Party. We based our assay on clinically-validated antibody clones and evaluated its performance on an IVD-certified full spectrum flow cytometer. We measured MRD and normal bone marrow samples and compared the MRD data to a widely used reference MRD-MFC panel generating highly concordant results. Using our newly developed single-tube panel, we established reference values in healthy bone marrow for 28 consensus leukemia-associated immunophenotypes and introduced a semi-automated dimensionality-reduction, clustering and cell type identification approach that aids the unbiased detection of aberrant cells. In summary, we provide a comprehensive full spectrum MRD-MFC workflow with the potential for rapid implementation for routine diagnostics due to reduced cell requirements and ease of data analysis with increased reproducibility in comparison to conventional FlowMRD routines.


Assuntos
Leucemia Mieloide Aguda , Humanos , Citometria de Fluxo/métodos , Reprodutibilidade dos Testes , Leucemia Mieloide Aguda/diagnóstico , Medula Óssea/metabolismo , Neoplasia Residual/diagnóstico
3.
Cytometry A ; 105(6): 458-463, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38511720

RESUMO

Full spectrum flow cytometry is a powerful tool for immune monitoring on a single-cell level and with currently available machines, panels of 40 or more markers per sample are possible. However, with an increased panel size, spectral unmixing issues arise, and appropriate single stain reference controls are required for accurate experimental results and to avoid unmixing errors. In contrast to conventional flow cytometry, full spectrum flow cytometry takes into account even minor differences in spectral signatures and requires the full spectrum of each fluorochrome to be identical in the reference control and the fully stained sample to ensure accurate and reliable results. In general, using the cells of interest is considered optimal, but certain markers may not be expressed at sufficient levels to generate a reliable positive control. In this case, compensation beads show some significant advantages as they bind a consistent amount of antibody independent of its specificity. In this study, we evaluated two types of manufactured compensation beads for use as reference controls for 30 of the most commonly used and commercially available fluorochromes in full spectrum cytometry and compared them to human and murine primary leukocytes. While most fluorochromes show the same spectral profile on beads and cells, we demonstrate that specific fluorochromes show a significantly different spectral profile depending on which type of compensation beads is used, and some fluorochromes should be used on cells exclusively. Here, we provide a list of important considerations when selecting optimal reference controls for full spectrum flow cytometry.


Assuntos
Citometria de Fluxo , Corantes Fluorescentes , Citometria de Fluxo/métodos , Humanos , Animais , Camundongos , Corantes Fluorescentes/química , Leucócitos/citologia , Leucócitos/metabolismo , Microesferas
4.
Clin Chem Lab Med ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38815136

RESUMO

OBJECTIVES: This study aimed to deliver biological variation (BV) estimates for 25 types of lymphocyte subpopulations subjected to deep immunophenotyping (memory T/B cells, regulatory T cells, etc.) and classical, intermediate, and nonclassical monocyte subsets based on the full spectrum flow cytometry (FS-FCM) and a Biological Variation Data Critical Appraisal Checklist (BIVAC) design. METHODS: Samples were collected biweekly from 60 healthy Chinese adults over 10 consecutive two-week periods. Each sample was measured in duplicate within a single run for lymphocyte deep immunophenotyping and monocyte subset determination using FS-FCM, including the percentage (%) and absolute count (cells/µL). After trend adjustment, a Bayesian model was applied to deliver the within-subject BV (CVI) and between-subject BV (CVG) estimates with 95 % credibility intervals. RESULTS: Enumeration (% and cells/µL) for 25 types of lymphocyte deep immunophenotyping and three types of monocyte subset percentages showed considerable variability in terms of CVI and CVG. CVI ranged from 4.23 to 47.47 %. Additionally, CVG ranged between 10.32 and 101.30 %, except for CD4+ effector memory T cells re-expressing CD45RA. No significant differences were found between males and females for CVI and CVG estimates. Nevertheless, the CVGs of PD-1+ T cells (%) may be higher in females than males. Based on the desired analytical performance specification, the maximum allowable imprecision immune parameter was the CD8+PD-1+ T cell (cells/µL), with 23.7 %. CONCLUSIONS: This is the first study delivering BV estimates for 25 types of lymphocyte subpopulations subjected to deep immunophenotyping, along with classical, intermediate, and nonclassical monocyte subsets, using FS-FCM and adhering to the BIVAC design.

5.
J Allergy Clin Immunol ; 151(1): 280-286.e2, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36122787

RESUMO

BACKGROUND: Azathioprine is a widely prescribed drug for patients with chronic inflammatory diseases such as myasthenia gravis or organ transplant recipients. Azathioprine exerts immunosuppressive effects by inhibiting intracellular purine synthesis and reducing the numbers of circulating B and T lymphocytes. Case reports indicate increased risk for serious infections that can occur despite regular measurements of lymphocyte counts during azathioprine therapy. OBJECTIVE: We sought to comprehensively investigate therapy-associated patient risks and the underlying immune dysfunction of azathioprine use. METHODS: Peripheral blood leukocytes were analyzed using single-cell mass and spectral flow cytometry to detect specific effects of azathioprine use on the systemic immune signature. Therapy-associated clinical features were analyzed in 2 independent cohorts of myasthenia gravis patients. RESULTS: Azathioprine therapy selectively induced pronounced CD56dimCD16+ natural killer cell depletion and concomitant IFN-γ deficiency. Cytokine profiling revealed a specific contraction of classical TH1 cells during azathioprine treatment. We further observed an increased occurrence of reactivation of endogenous latent herpesviruses in the azathioprine-treated group versus in patients with myasthenia gravis who were not receiving immunomodulatory treatment; this increased occurrence was validated in an independent cohort. CONCLUSION: Our study highlights the risk of development of adverse events during azathioprine therapy and suggests that natural killer cell monitoring could be valuable in clinical practice.


Assuntos
Herpesviridae , Miastenia Gravis , Humanos , Azatioprina/efeitos adversos , Células Matadoras Naturais , Interferon gama/farmacologia , Miastenia Gravis/tratamento farmacológico , Miastenia Gravis/induzido quimicamente
6.
AAPS PharmSciTech ; 25(5): 120, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816596

RESUMO

Cannabinoids, such as ∆9-tetrahydrocannabinol (THC) and cannabidiol (CBD), are effective bioactive compounds that improve the quality of life of patients with certain chronic conditions. The copolymer poly(lactic-co-glycolic acid) (PLGA) has been used to encapsulate such compounds separately, providing pharmaceutical grade edible products with unique features. In this work, a variety of PLGA based nanoformulations that maintain the natural cannabinoid profile found in the plant (known as full-spectrum) are proposed and evaluated. Three different cannabis sources were used, representing the three most relevant cannabis chemotypes. PLGA nanocapsules loaded with different amounts of cannabinoids were prepared by nanoemulsion, and were then functionalized with three of the most common coating polymers: pectin, alginate and chitosan. In order to evaluate the suitability of the proposed formulations, all the synthesized nanocapsules were characterized, and their cannabinoid content, size, zeta-potential, morphology and in vitro bioaccessibility was determined. Regardless of the employed cannabis source, its load and the functionalization, high cannabinoid content PLGA nanocapsules with suitable particle size and zeta-potential were obtained. Study of nanocapsules' morphology and in vitro release assays in gastro-intestinal media suggested that high cannabis source load may compromise the structure of nanocapsules and their release properties, and hence, the use of lower content of cannabis source is recommended.


Assuntos
Cannabis , Nanopartículas , Tamanho da Partícula , Extratos Vegetais , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Cannabis/química , Nanopartículas/química , Extratos Vegetais/química , Liberação Controlada de Fármacos , Canabinoides/química , Canabidiol/química , Nanocápsulas/química , Portadores de Fármacos/química , Ácido Poliglicólico/química , Ácido Láctico/química , Quitosana/química , Química Farmacêutica/métodos , Alginatos/química , Pectinas/química , Trato Gastrointestinal/metabolismo
7.
Angew Chem Int Ed Engl ; : e202411298, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39011619

RESUMO

The engineering of tunable photoluminescence (PL) in single materials with a full-spectrum emission represents a highly coveted objective but poses a formidable challenge. In this context, the realization of near-full-spectrum PL emission, spanning the visible light range from 424 to 620 nm, in a single-component two-dimensional (2D) hybrid lead halide perovskite, (ETA)2PbBr4 (ETA+ = (HO)(CH2)2NH3+), is reported, achieved through high-pressure treatment. A pressure-induced phase transition occurs upon compression, transforming the crystal structure from an orthorhombic phase under ambient conditions to a monoclinic structure at high pressure. This phase transition driven by the adaptive and dynamic configuration changes of organic amine cations enables an effective and continuous narrowing of the bandgap in this halide crystal. The hydrogen bonding interactions between inorganic layers and organic amine cations (N-H…Br and O-H…Br hydrogen bonds) efficiently modulate the organic amine cations penetration and the octahedral distortion. Consequently, this phenomenon induces a phase transition and results in red-shifted PL emissions, leading to the near-full-spectrum emission. This work opens a possibility for achieving wide PL emissions with coverage across the visible light spectrum by employing high pressure in single halide perovskites.

8.
Am J Physiol Lung Cell Mol Physiol ; 325(4): L518-L535, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37581225

RESUMO

Studies of pulmonary inflammation require unique considerations due to the complex structure and composition of the lungs. The lungs have multiple compartments and diverse immune cell populations, with inherently high autofluorescence, and are involved in the host response to pulmonary pathogens. We describe a protocol that accounts for these factors through a novel combination of methodologies-in vivo compartmental analysis and spectral flow cytometry with a broad panel of antibodies. In vivo compartmental analysis enables the precise localization of immune cells within the marginated vasculature, lung interstitium, nonlavageable airways, and lavageable airways of the lungs, as well as the pulmonary lymph nodes. Spectral flow cytometry with a broad panel of antibodies supports an unbiased exploratory approach to investigating diverse immune cell populations during pulmonary inflammation. Most importantly, spectral flow uses cellular autofluorescence to aid in the resolution and identification of immune cell populations. This methodology enables the acquisition of high-quality data compatible with informed gating and dimensionality reduction algorithms. In addition, our protocol emphasizes considerations for compartmentalization of the inflammatory response, spectral flow panel design, and autofluorescence spectra analysis. These methodologies are critical for increasing the rigor of pulmonary research. We apply this protocol for the precise characterization and localization of leukocytes in the pulmonary host response to influenza A virus in C57BL/6J mice. In particular, we demonstrate that this protocol improves the quantification and localization of alveolar macrophages within the airways. The methodology is modifiable and expandable to allow for further characterization of leukocyte populations of special interest.NEW & NOTEWORTHY We describe a novel combination of methodologies that incorporates dual in vivo compartmental analysis using intravascular and intratracheal CD45 labeling, a broad panel of antibodies for identifying lymphoid and nonlymphoid cells, and spectral flow cytometry that uses cellular autofluorescence to aid in resolving and identifying immune cell populations. This methodology allows precise localization of immune cells in the lavageable airways, nonlavageable airways, interstitial lung tissue, and marginated in the lung vasculature.


Assuntos
Pulmão , Pneumonia , Camundongos , Animais , Citometria de Fluxo/métodos , Camundongos Endogâmicos C57BL , Leucócitos , Pneumonia/patologia , Anticorpos
9.
Cytometry A ; 103(2): 110-116, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36331092

RESUMO

This 25-parameter, 22-color full spectrum flow cytometry panel was designed and optimized for the comprehensive enumeration and functional characterization of innate lymphoid cell (ILC) subsets in mouse tissues. The panel presented here allows the discrimination of ILC progenitors (ILCP), ILC1, ILC2, NCR+ ILC3, NCR- ILC3, CCR6+ lymphoid tissue-inducer (LTi)-like ILC3 and mature natural killer (NK) cell populations. Further characterization of ILC and NK cell functional profiles in response to stimulation is provided by the inclusion of subset-specific cytokine markers, and proliferation markers. Development and optimization of this panel was performed on freshly isolated cells from adult BALB/c lungs and small intestine lamina propria, and ex vivo stimulation with phorbol 12-myrisate 13-acetate, ionomycin, and pro-ILC activating cytokines.


Assuntos
Imunidade Inata , Linfócitos , Camundongos , Animais , Imunofenotipagem , Citometria de Fluxo , Células Matadoras Naturais , Citocinas
10.
Cytometry A ; 103(11): 839-850, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37768325

RESUMO

High-dimensional immunoprofiling is essential for studying host response to immunotherapy, infection, and disease in murine model systems. However, the difficulty of multiparameter panel design combined with a lack of existing murine tools has prevented the comprehensive study of all major leukocyte phenotypes in a single assay. Herein, we present a 40-color flow cytometry panel for deep immunophenotyping of murine lymphoid tissues, including the spleen, blood, Peyer's patches, inguinal lymph nodes, bone marrow, and thymus. This panel uses a robust set of surface markers capable of differentiating leukocyte subsets without the use of intracellular staining, thus allowing for the use of cells in downstream functional experiments or multiomic analyses. Our panel classifies T cells, B cells, natural killer cells, innate lymphoid cells, monocytes, macrophages, dendritic cells, basophils, neutrophils, eosinophils, progenitors, and their functional subsets by using a series of co-stimulatory, checkpoint, activation, migration, and maturation markers. This tool has a multitude of systems immunology applications ranging from serial monitoring of circulating blood signatures to complex endpoint analysis, especially in pre-clinical settings where treatments can modulate leukocyte abundance and/or function. Ultimately, this 40-color panel resolves a diverse array of immune cells on the axes of time, tissue, and treatment, filling the niche for a modern tool dedicated to murine immunophenotyping.


Assuntos
Imunidade Inata , Tecido Linfoide , Camundongos , Animais , Citometria de Fluxo/métodos , Linfócitos T , Células Matadoras Naturais , Imunofenotipagem
11.
Cytometry A ; 101(11): 942-959, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35593221

RESUMO

High-dimensional single-cell data has become an important tool in unraveling the complexity of the immune system and its involvement in homeostasis and a large array of pathologies. As technological tools are developed, researchers are adopting them to answer increasingly complex biological questions. Up until recently, mass cytometry (MC) has been the main technology employed in cytometric assays requiring more than 29 markers. Recently, however, with the introduction of full spectrum flow cytometry (FSFC), it has become possible to break the fluorescence barrier and go beyond 29 fluorescent parameters. In this study, in collaboration with the Stanford Human Immune Monitoring Center (HIMC), we compared five patient samples using an established immune panel developed by the HIMC using their MC platform. Using split samples and the same antibody panel, we were able to demonstrate highly comparable results between the two technologies using multiple data analysis approaches. We report here a direct comparison of two technology platforms (MC and FSFC) using a 32-marker flow cytometric immune monitoring panel that can identify all the previously described and anticipated immune subpopulations defined by this panel.


Assuntos
Análise de Dados , Humanos , Citometria de Fluxo/métodos , Imunofenotipagem , Biomarcadores
12.
Cytometry A ; 101(11): 970-983, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35716345

RESUMO

Acute myeloid leukemia (AML) measurable residual disease (MRD) evaluated by multiparametric flow cytometry (MFC) is a surrogate for progression-free and overall survival in clinical trials and patient management. Due to the limited number of detection channels available in conventional flow cytometers, panels used for assessing AML MRD are typically split into multiple tubes. This cripples the simultaneous and correlated assessment of all myeloblast measurements. In response, we prototyped a single-tube 27-color MFC assay for the evaluation of AML MRD, incorporating all recommended markers. Marrow aspirates from 22 patients were processed for analysis using full spectrum flow cytometry (FSFC). The signal resolution of each marker was compared between samples stained with single antibody vs. the fully stained panel. The analytical accuracy for quantifying hematopoietic cells between our established 8-color assay and the new 27-color method were compared. Variations within an operator and between separate operators were assessed to evaluate the assays reproducibility. The limited of blank (LOB), limit of detection (LOD), and lower limit of quantification (LLOQ) of the 27-color method were empirically determined using limiting dilution experiments. The stability of antibody cocktails over a period of 120 h was also studied using cryopreserved marrow cells. The stain indices for all antibodies were lower in the fully stained panel compared to cells stained with one antibody but clear separations between negative and positive signals were achieved for all antibodies. Our results demonstrated a high concordance between the established 8-color method and the new 27-color assay for enumerating myeloblasts and MRD interpretation within and between operators. The data further showed that the single-tube 27-color assay easily achieved the minimum required detection sensitivity of 0.1%. When antibodies were combined, however, expression intensity of some antigens deteriorated significantly when stored. Our single-tube 27-color panel is a suitable, high sensitivity flow cytometric approach that can be used for AML MRD testing, which improves the correlation of aberrant antigens and detection of asynchronous differentiation patterns. Based on the stability study, we recommend the full panel be made prior to staining.


Assuntos
Leucemia Mieloide Aguda , Humanos , Reprodutibilidade dos Testes , Neoplasia Residual/diagnóstico , Leucemia Mieloide Aguda/diagnóstico , Citometria de Fluxo/métodos , Medula Óssea , Anticorpos
13.
Cytometry A ; 101(10): 862-876, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35608022

RESUMO

Autofluorescence (AF) is an intrinsic characteristic of cells caused by the presence of fluorescent biological compounds within the cell; these can include structural proteins (e.g., collagen and elastin), cellular organelles, and metabolites (e.g., aromatic amino acids). In flow cytometric studies, the presence of AF can lead to reduced antigen and population resolution, as well as the presence of artifacts due to false positive events. Here, we describe a methodology that uses the inherent ability of full spectrum cytometry to treat AF as a fluorochrome and to thereby separate it from the other fluorochromes of the assay. This method can be applied to complex inflamed tissues; for instance, in regenerating skeletal muscle we have developed a 16-color panel targeting highly autofluorescent myeloid cells. This represents a first step toward overcoming technological limitations in flow cytometry due to AF.


Assuntos
Elastina , Corantes Fluorescentes , Aminoácidos Aromáticos , Citometria de Fluxo/métodos , Músculo Esquelético , Células Mieloides
14.
Cytometry A ; 101(10): 846-855, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35388953

RESUMO

Fluorescent proteins (FPs) have become an essential tool for biological research. Since the isolation and description of GFP, hundreds of fluorescent proteins have been discovered and created with various characteristics. The excitation of these proteins ranges from ultra-violet (UV) up to near infra-RED (NIR). Using conventional cytometry with each detector assigned to each fluorochrome, great care must be taken when selecting the optimal bandpass filters to minimalize the spectral overlap. In the last 8 years, several companies have released full spectrum flow cytometers which eliminates the need to change optical filters for analyzing FPs. This addressed at least part of the problem however, the laser wavelengths in commercial instruments are generally not ideal for all fluorescent proteins yet do allow the separation of at least six FPs. Another technical challenge is to have convenient single color controls. If four different FPs are being used in an experiment, single color controls will be needed to compensate or unmix the data. In the case of cultured cells this will involve having each of the FPs expressed in cell lines separately with a parental cell line expressing none. In the case of in vivo experiments, colonies of animals may need to be maintained expressing each FP along with a wildtype animal. This represents a considerable expense and inconvenience. An appealing alternative is to produce and purify FPs and covalently couple to polystyrene microspheres. Such microspheres are ready to use and can be stored at 4°C for months or even years without any deterioration in fluorescence. The same procedure can be used to couple antibodies to these particles. Here we describe this procedure which can be executed in any lab without any special equipment or skills.


Assuntos
Corantes Fluorescentes , Poliestirenos , Animais , Anticorpos , Citometria de Fluxo/métodos , Proteínas de Fluorescência Verde , Proteínas Luminescentes/metabolismo , Microesferas
15.
Cytometry A ; 101(10): 856-861, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35521651

RESUMO

Using full spectrum flow cytometry, we designed a 28-color panel for the analysis of markers known to be associated with the γδ T cell immune response. This panel allows the classification of γδ T cell subsets via specific V gene usage (Vγ9, Vδ1, Vδ2, and Vδ3) of their T cell receptor (TCR) and according to their functional differentiation. Phenotypical surface receptors to distinguish different stages of cell maturation included CD45RA, CD27, CD28, CD127, CD57, and CD16; chemokine receptors CXCR6, CCR5, CCR6, and CX3CR1; NK-associated markers NKG2A, NKG2D, CD56, and CD161, checkpoint-inhibitor PD-1, and activating receptors CD38 and CD25. T cell lineage markers for the analysis of αß T cells (CD4 and CD8) and MAIT cells (Vα7.2) were also included. This optimized multicolor panel allows a comprehensive immune-profiling of all main human γδ T cell subsets and is suitable for longitudinal or exploratory analysis of γδ T cell development and γδ T cell dynamics in clinical cohorts.


Assuntos
Antígenos CD28 , Receptores de Antígenos de Linfócitos T gama-delta , Antígenos CD28/metabolismo , Citometria de Fluxo , Humanos , Subfamília K de Receptores Semelhantes a Lectina de Células NK/metabolismo , Receptor de Morte Celular Programada 1/metabolismo , Receptores de Antígenos de Linfócitos T gama-delta/metabolismo , Receptores de Quimiocinas/metabolismo , Subpopulações de Linfócitos T
16.
Cytometry A ; 101(11): 922-941, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35349225

RESUMO

Understanding the complex elements affecting signal resolution in cytometry is key for quality experimental design and data. In this study, we incorporate autofluorescence as a contributing factor to our understanding of resolution in cytometry and corroborate its impact in fluorescence signal detection through mathematical predictions supported by empirical evidence. Our findings illustrate the critical importance of autofluorescence extraction via full spectrum unmixing in unmasking dim signals and delineating the expression and subset distribution of low abundance markers in discovery projects. We apply our findings to the precise definition of the tissue and cellular distribution of a weakly expressed fluorescent protein that reports on a low-abundance immunological gene. Exploiting the full spectrum coverage enabled by Aurora 5L, we describe a novel approach to the isolation of pure cell subset-specific autofluorescence profiles based on high dimensionality reduction algorithms. This method can also be used to unveil differences in the autofluorescent fingerprints of tissues in homeostasis and after immunological challenges.


Assuntos
Algoritmos , Corantes , Imunofenotipagem
17.
Molecules ; 27(20)2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-36296511

RESUMO

Differences between therapeutic effects of medical cannabis inflorescences and those of their extracts are generally attributed to the differences in administration form and in the resultant pharmacokinetics. We hypothesized that difference may further extend to the composition of the actually consumed drug. Cannabinoid and terpene contents were compared between commercial cannabis inflorescences (n = 19) and decarboxylated extracts (n = 12), and between inflorescences and decarboxylated extracts produced from them (n = 10). While cannabinoid content was preserved in the extracts, a significant loss of terpenes was evident, mainly in the more volatile monoterpenes and monoterpenoids (representing a loss of about 90%). This loss changes the total terpene content, the proportion of monoterpenes out of the total terpenes, and the monoterpene/cannabinoid ratio. Terpene deficiency might impair extracts' pharmacological efficacy and might contribute to the patients' preference to inflorescences-smoking. This argues against the validity of terms such as "whole plant" and "full spectrum" extracts and creates a misleading assumption that extracts represent the pharmacological profile of the sourced inflorescences. Furthermore, it reduces the diversity in extracts, such as loss of differences between sativa-type and indica-type. Enriching cannabis extracts with selected terpenes may provide a suitable solution, generating a safe, precise, and reproducible drug with tailored cannabinoid and terpene contents. Careful selection of terpenes to be added enables tailor-made extracts, adjusted for various medicinal aims and for different populations.


Assuntos
Canabinoides , Cannabis , Alucinógenos , Maconha Medicinal , Humanos , Terpenos , Monoterpenos , Agonistas de Receptores de Canabinoides , Extratos Vegetais
18.
Angew Chem Int Ed Engl ; 61(39): e202204561, 2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-35931663

RESUMO

Developing light-harvesting materials with broad spectral response is of fundamental importance in full-spectrum solar energy conversion. We found that, when a series of earth-abundant metal (Cu, Co, Ni and Fe) salts are dissolved in coordinating solvents uniformly dispersed nanodots (NDs) are formed rather than fully dissolving as molecular species. The previously unrecognized formation of this condensed state is ascribed to spontaneous aggregation of molecular transition-metal-complexes (TMCs) via weak intermolecular interactions, which results in redshifted and broadened absorption into the NIR region (200-1100 nm). Typical photoredox reactions, such as carbonylation and oxidative dehydrogenation, well demonstrate the feasibility of efficient utilization of NIR light (λ>780 nm) by TMCs NDs. Our finding provides a conceptually new strategy for extending the absorption towards low energy photons in solar energy harvesting and conversion via photoredox transformations.

19.
Br J Clin Pharmacol ; 87(4): 2070-2077, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33075170

RESUMO

AIMS: This study investigated the safety, tolerability and pharmacokinetics after administration of a specific Cannabis sativa cultivar extract, standardised to cannabidiol (CBD) content as sublingual wafer or oil formulation compared to nabiximols oromucosal spray. METHODS: For the single-dose study, the design was an open-label, 4-way crossover in 12 healthy volunteers randomised to receive a sequence of 4 different single doses of CBD as a sublingual wafer (25 or 50 mg CBD), oil solution (50 mg CBD), or nabiximols oromucosal spray (20 mg CBD, 21.6 mg tetrahydrocannabinol). For the multiple-dose study, sublingual wafer (50 mg CBD) was administered twice a day for 5 days. RESULTS: The extract was generally well tolerated by participants when administered in either wafer or oil form, with some adverse events, including mild or moderate somnolence, sedation and altered mood. The relative bioavailability of CBD after administration as a sublingual wafer was comparable with that of oil solution with 90% confidence interval of 83-131%. The median maximum concentrations of CBD after administration of oil solution and wafer was 9.4 and 11.9 ng mL-1 , respectively. Maximum concentrations of CBD occurred 4 hours after administration, with an estimated terminal elimination half-life of 6 hours. There was no statistically significant difference between the AUC0-τ of CBD after administration of oil solution or wafer compared with nabiximols oromucosal spray. CONCLUSION: Oil solution and sublingual wafer formulations of the extract standardised with CBD were well tolerated and achieved equivalent concentrations of CBD when compared to an available commercial nabiximols formulation.


Assuntos
Canabidiol , Administração Sublingual , Disponibilidade Biológica , Canabidiol/efeitos adversos , Estudos Cross-Over , Voluntários Saudáveis , Humanos
20.
Int Ophthalmol ; 41(6): 2187-2196, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33725269

RESUMO

PURPOSE: Report the foveal avascular zone (FAZ) area imaged by OCT angiography (OCTA) using a full spectrum probabilistic algorithm in eyes of healthy individuals from Costa Rica without any ocular or systemic pathology. METHODS: Retrospective chart review of consecutive healthy patients that were evaluated from January 2018 to October 2018 that underwent OCTA of the macular area. The OCTA consisted of a 10° × 10° cube of 512 A scans separated by 6 µm each with an automated real time mode of 5. The FAZ area of the superficial vascular complex (SVC), the deep vascular complex (DVC), superficial vascular plexus (SVP), intermediate vascular plexus (IVP) and the deep vascular plexus (DVP) were measured manually by 2 different observers at 3 different times. RESULTS: A total of 234 eyes of 121 patients were included in this study. Mean age was 50 years (range, 15-89), 85 patients (70%) were female. Inter- and intra-observer agreements were excellent. The mean FAZ areas in the different layers were 0.258 ± 0.0035 mm2 for the SVC, 0.205 ± 0.01 mm2 for the DVC, 0.415 ± 0.01 mm2 for the SVP, 0.305 ± 0.01 mm2 for the ICP and 0.420 ± 0.01 mm2 for the DCP. The mean FAZ areas in most of the measured layers increased with age and decreased with CMT. Gender and spherical equivalence were not correlated with FAZ area. CONCLUSION: Manual measurements of the FAZ imaged by OCT-A using a full spectrum probabilistic algorithm are widely reproducible both by the same observer and between observers. The FAZ increases with age and decreases with CMT in normal individuals.


Assuntos
Fóvea Central , Vasos Retinianos , Algoritmos , Feminino , Angiofluoresceinografia , Humanos , Masculino , Pessoa de Meia-Idade , Vasos Retinianos/diagnóstico por imagem , Estudos Retrospectivos , Tomografia de Coerência Óptica