1.
J Radiol Prot ; 44(2)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38530296

RESUMO

Calibration of 22 gamma camera units was performed at 15 hospitals in southern and western Sweden to estimate137Cs contamination in humans in a supine static geometry, with a new developed calibration protocol and phantom. The minimum detectable activities (MDAs) and the estimated committed effective doses (CEDs) were calculated for each calibration. Generic calibration factors were calculated for five predetermined groups based on the detector type and manufacturer. Group 1 and 2 included NaI-based gamma cameras from General Electrics (GEs) with a crystal thickness of 5/8'' and 3/8'' respectively. Group 3 and 4 included NaI-based gamma cameras from Siemens Healthineers with a crystal thickness of 3/8'', with a similar energy window as the GE NaI-based cameras and a dual window respectively. Group 5 included semiconductor-based gamma cameras from GE with a CdZnTe (CZT) detector. The generic calibration factors were 60.0 cps kBq-1, 52.3 cps kBq-1, 50.3 cps kBq-1, 53.2 cps kBq-1and 48.4 cps kBq-1for group 1, 2, 3, 4, and 5 respectively. The MDAs ranged between 169 and 1130 Bq for all groups, with measurement times of 1-10 min, corresponding to a CED of 4.77-77.6µSv. A dead time analysis was performed for group 1 and suggested a dead time of 3.17µs for137Cs measurements. The dead time analysis showed that a maximum count rate of 232 kcps could be measured in the calibration geometry, corresponding to a CED of 108-263 mSv. It has been shown that semiconductor-based gamma cameras with CZT detectors are feasible for estimating137Cs contamination. The generic calibration factors derived in this study can be used for gamma cameras of the same models in other hospitals, for measurements in the same measurement geometry. This will increase the measurement capability for estimating internal137Cs contamination in the recovery phase following radiological or nuclear events.


Assuntos
Cádmio , Radioisótopos de Césio , Câmaras gama , Telúrio , Zinco , Humanos , Calibragem
2.
Semin Cancer Biol ; 84: 302-309, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-31982511

RESUMO

Here we proposed the most recent innovations in the use of Breast Specific Gamma Imaging with 99mTc-sestamibi for the management of breast cancer patients. To this end, we reported the recent discoveries concerning: a) the implementation of both instrumental devices and software, b) the biological mechanisms involved in the 99mTc-sestamibi uptake in breast cancer cells, c) the evaluation of Breast Specific Gamma Imaging with 99mTc-sestamibi as predictive markers of metastatic diseases. In this last case, we also reported preliminary data about the capability of Breast Specific Gamma Imaging with 99mTc-sestamibi to identify breast cancer lesions with high propensity to form bone metastatic lesions due to the presence of Breast Osteoblast-Like Cells.


Assuntos
Neoplasias da Mama , Tecnécio Tc 99m Sestamibi , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Cintilografia , Compostos Radiofarmacêuticos
3.
J Surg Res ; 285: 176-186, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36682343

RESUMO

INTRODUCTION: Sentinel lymph node biopsy (SLNB) is a standard practice for staging cutaneous melanoma. High false-negative rates have an increased interest in adjunctive techniques for localizing SLNs. Mobile gamma cameras (MGCs) represent potential tools to enhance SLNB performance. METHODS: An institutional review board approval was obtained for this study (ClinicalTrials.gov ID NCT01531608). After obtaining informed consent, 20 eligible melanoma patients underwent 99mTc sulfur colloid injection and standard lymphoscintigraphy with a fixed gamma camera (FGC). A survey using a 20 cm square MGC, performed immediately preoperatively by the study surgeon, was used to establish an operative plan while blinded to the FGC results. Subsequently, SLNB was performed using a gamma probe and a novel 6 cm diameter handheld MGC. RESULTS: A total of 24 SLN basins were detected by FGC. Prior to unblinding, all 24 basins were identified with the preoperative MGC and the operative plan established by preoperative MGC imaging was confirmed accurate by review of the FGC images. All individual sentinel lymph nodes were identified during intraoperative MGC imaging, and in 5/24 (21%) cases, surgeon-reported additional clinically useful information was obtained from the MGC. CONCLUSIONS: Preoperative MGC images provide information consistent with FGC images for planning SLNB and in some cases provide additional information that aided in surgical decision-making.


Assuntos
Melanoma , Neoplasias Cutâneas , Humanos , Câmaras gama , Linfonodos/patologia , Linfocintigrafia , Melanoma/patologia , Compostos Radiofarmacêuticos , Biópsia de Linfonodo Sentinela/métodos , Neoplasias Cutâneas/patologia , Coloide de Enxofre Marcado com Tecnécio Tc 99m
4.
Pharm Res ; 40(3): 765-775, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36653519

RESUMO

PURPOSE: Preclinical aerosol studies using animals are essential for evaluating toxic or therapeutic effects on human respiratory tract. Macaques are relevant animal models for respiratory studies, but they are sensitive, expensive and difficult-to-access. METHODS: In the context of preliminary studies before animal experiments, we set up an alternative in vitro anatomical model of macaque airways to reduce, refine and replace (3Rs) the animals. We printed an in vitro anatomical cast until the third bronchial division from X-ray computed tomography data of a healthy cynomolgus macaque. This in vitro model was then connected to a respiratory pump to mimic macaque's breathing. We assessed the relevance of this in vitro model, by comparing aerosol deposition patterns obtained with the anatomical model and in three macaques using planar gamma camera imaging. DTPA-99mTechnetium aerosols were produced using three jet nebulizers, generating three different particle sizes: 13.1, 3.2 and 0.93 µm in terms of the mass median aerodynamic diameter (MMAD). RESULTS: The data showed no statistical differences between the animal and anatomical in vitro models in terms of total aerosol deposited in the airways. However, the distribution of the deposition in the airways showed a higher deposited fraction in the upper respiratory tract in the animals than the in vitro model for all particle sizes. CONCLUSIONS: The anatomical printed model appears to be a relevant in vitro tool to predict total aerosol deposition in macaque airways.


Assuntos
Pulmão , Nebulizadores e Vaporizadores , Animais , Humanos , Administração por Inalação , Aerossóis , Macaca , Impressão Tridimensional , Tamanho da Partícula
5.
Eur Arch Otorhinolaryngol ; 280(12): 5519-5529, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37493844

RESUMO

PURPOSE: Evaluating the Crystal Cam handheld gamma-camera for preoperative and intraoperative sentinel lymph node (SLN) localization in early-stage oral cancer. METHODS: The handheld gamma-camera was used complementary to conventional gamma-probe guidance for intraoperative SLN localization in 53 early-stage oral cancer patients undergoing SLN biopsy. In 36 of these patients, a blinded comparison was made between preoperative handheld gamma-camera and lymphoscintigraphy outcomes. Of those, the reliability for marking the SLN's location using both handheld gamma-camera and a 57Co-penpoint marker was evaluated in 15 patients. RESULTS: In the entire cohort, the handheld gamma-camera preoperatively detected 116/122 (95%) of SLNs identified by lymphoscintigraphy. In those patients where the observer was blinded for lymphoscintigraphy (n = 36), 71/77 (92%) SLNs were correctly identified by handheld gamma-camera. Overlooked SLNs by handheld gamma-camera were mainly located near the injection site. The SLN's marked location by handheld gamma-camera and 57Co-penpoint marker was considered accurate in 42/43 (98%) SLNs. The intraoperative use of the handheld gamma-camera led to the extirpation of 16 additional 'hot' lymph nodes in 14 patients, 4 of which harbored metastases, and prevented 2 patients (4%) from being erroneously staged negative for nodal metastasis. In those with follow-up ≥ 24 months or false-negative outcomes < 24 months following SLNB, a sensitivity of 82% and negative predictive value of 93% was obtained. CONCLUSION: The Crystal Cam handheld gamma-camera offers reliable preoperative and intraoperative SLN localization and might reduce the risk of missing a malignant SLN during surgery. Detecting SLNs near the injection site by handheld gamma-camera remains challenging.


Assuntos
Neoplasias Bucais , Linfonodo Sentinela , Humanos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Linfonodo Sentinela/patologia , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Reprodutibilidade dos Testes , Biópsia de Linfonodo Sentinela , Linfonodos/diagnóstico por imagem , Linfonodos/cirurgia , Neoplasias Bucais/diagnóstico por imagem , Neoplasias Bucais/cirurgia , Neoplasias Bucais/patologia
6.
J Appl Clin Med Phys ; 24(8): e14077, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37357570

RESUMO

INTRODUCTION: Performing lymphoscintigraphy in a separate room, frees up the conventional gamma camera, coupled with the desire to directly localize sentinel lymph nodes (SLN) in the operating theatre has led to the development of high-resolution semiconductor-detector based handheld gamma-cameras, CrystalCam. METHODS: This work consists of phantom and clinical studies. For the first part, a Jaszczak phantom with hollow spheres of various volumes were filled with the 99m Tc and the camera's sensitivity was measured at various distances to assess the possibilities and limitations of the device. The clinical study evaluates the effectiveness of CrystalCam in localizing SLN in 40 consecutive malignant melanoma patients compared to both conventional planar lymphoscintigraphy and hybrid SPECT/CT. SLNs detected by planar lymphoscintigraphy were marked on the patients' skin using a UV-marker. CrystalCam images were acquired in another room by another examiner and the SLNs were marked with a felt pen. The detected nodes by both camera systems were evaluated using UV-lamp and normal light to visualize the UV- and felt pen marks respectively. The concordance rate of the SLNs and higher-echelon nodes localized by both planar scintigraphy and CrystalCam imaging with respect to the total SLNs and higher-echelon nodes detected by SPECT/CT imaging are compared and statistically analyzed. RESULTS: The results of the phantom study show a good correlation between activity and count-rates for all distancesSPECT/CT, CrystalCamm, and planar lymphoscintigraphy detected 69, 58, and 61 SLNs respectively. The concordance rate of 95.65% by the CrystalCam and planar scintigraphy implies both cameras are statistically coequal in preoperative SLN detection of malignant melanoma. For the higher-echelon nodes, SPECT/CT, planar and CrystalCam imaging systems identified 82, 48, and 13 respectively; thus, CrystalCam was statistically inferior to planar imaging. CONCLUSION: The handheld CrystalCam is a reliable instrument for localizing SLNs in surgical centers without an on-site nuclear medicine department.


Assuntos
Melanoma , Linfonodo Sentinela , Humanos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/patologia , Linfocintigrafia/métodos , Câmaras gama , Metástase Linfática , Melanoma/diagnóstico por imagem , Melanoma/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Melanoma Maligno Cutâneo
7.
Sensors (Basel) ; 23(2)2023 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-36679750

RESUMO

(1) Background: Gamma cameras have wide applications in industry, including nuclear power plant monitoring, emergency response, and homeland security. The desirable properties of a gamma camera include small weight, good resolution, large field of view (FOV), and wide imageable source energy range. Compton cameras can have a 4π FOV but have limited sensitivity at low energy. Coded-aperture gamma cameras are operatable at a wide photon energy range but typically have a limited FOV and increased weight due to the thick heavy metal collimators and shielding. In our lab, we previously proposed a 4π-view gamma imaging approach with a 3D position-sensitive detector, with which each detector element acts as the collimator for other detector elements. We presented promising imaging performance for 99mTc, 18F, and 137Cs sources. However, the imaging performance for middle- and high-energy sources requires further improvement. (2) Methods: In this study, we present a new gamma camera design to achieve satisfactory imaging performance in a wide gamma energy range. The proposed gamma camera consists of interspaced bar-shaped GAGG (Ce) crystals and tungsten absorbers. The metal bars enhance collimation for high-energy gamma photons without sacrificing the FOV. We assembled a gamma camera prototype and conducted experiments to evaluate the gamma camera's performance for imaging 57Co, 137Cs, and 60Co point sources. (3) Results: Results show that the proposed gamma camera achieves a positioning accuracy of <3° for all gamma energies. It can clearly resolve two 137Cs point sources with 10° separation, two 57Co and two 60Co point sources with 20° separation, as well as a 2 × 3 137Cs point-source array with 20° separation. (4) Conclusions: We conclude that the proposed gamma camera design has comprehensive merits, including portability, 4π-view FOV, and good angular resolution across a wide energy range. The presented approach has promising potential in nuclear security applications.


Assuntos
Câmaras gama , Metais Pesados , Desenho de Equipamento , Diagnóstico por Imagem
8.
J Radiol Prot ; 43(1)2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36749985

RESUMO

A survey was performed of the available gamma camera models and whole-body counters (WBCs) in Sweden, revealing that there are about 75 gamma cameras and 15 WBCs currently in operation in Sweden. One of the most common gamma camera models (GE Discovery NM/CT 670 Pro), with the collimators removed, was calibrated for152Eu,137Cs,60Co and40K in three different measurement geometries (supine, close-up sitting and distant sitting) for six different phantom sizes (12-110 kg). Minimum detectable activities (MDAs) were calculated for the gamma camera and a typical WBC, both at the Sahlgrenska University Hospital in Gothenburg, Sweden. An energy window of 30-510 keV was used to calibrate the gamma camera. The calibration factors for this gamma camera for supine and close-up sitting geometry, including all phantom sizes, were 138-208 cps kBq-1for152Eu, 63-83 cps kBq-1for137Cs and 99-126 cps kBq-1for60Co; the MDAs were 50-73 Bq for152Eu, 125-198 Bq for137Cs and 83-105 Bq for60Co. The International Commission on Radiological Protection dose coefficients for members of the public were used to calculate the committed effective doses (CEDs) corresponding to the MDAs, showing that CEDs down to a fewµSv can be estimated with this gamma camera for the inhalation of aerosols of absorption type M. The distant sitting geometry was used to enable the estimation of higher contamination levels, and a hypothetical maximum CED was calculated. This was shown to be 256-2000 mSv, depending on the radionuclide and phantom size. However, further investigations are needed into the dead time losses for higher activity levels for the radionuclides studied. The results show that the use of gamma cameras for radiological triage and, in some cases, to estimate the internal activity of relevant radionuclides in radiological and nuclear events, is feasible.


Assuntos
Defesa Civil , Câmaras gama , Humanos , Calibragem , Radioisótopos de Césio , Tomografia Computadorizada por Raios X
9.
Eur J Nucl Med Mol Imaging ; 49(1): 361-370, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34185137

RESUMO

PURPOSE: Radioguided occult lesion localization (ROLL) of pulmonary nodules is an alternative to hook-wire. Both required of a histological margin assessment. The activity emerging from the radiotracer allows to obtain an intraoperative scintigraphic image of the surgical specimen by a portable gamma-camera (PGC) fitted with an optical view, which provides information about the localization of the nodule in relation to the margins. The aim of this study was to evaluate the intraoperative use of a PGC for margin assessment of pulmonary nodules. METHODS: ROLL technique was used in 38 nodules (36 pulmonary, 1 chest wall, and 1 pleural nodules). A PGC intraoperative image of the surgical specimen was obtained in 32. Scintigraphic results were compared to the histological assessment. Other factors, such as nodule size, distance from the pleural surface, or distance covered by the needle, were considered as possible factors for non-centered lesions. RESULTS: PGC images showed that the lesion was in contact with the margins in 8/32 cases and centered in 24. In all cases in which the lesion was considered as centered by the PGC, the margins were free of involvement (NPV 100%), although the PPV is low. CONCLUSIONS: The use of a PGC for margin assessment after pulmonary nodule resection is feasible and provides a high NPV in our series. In addition, the short intraoperative time required for its use makes the PGC a useful tool for providing supplementary information to histopathologic results. Further studies from different surgical teams are required for an external validation.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Cirurgia Assistida por Computador , Câmaras gama , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Cintilografia
10.
Sensors (Basel) ; 21(10)2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-34066113

RESUMO

In this work, we propose and analyze a new concept of gamma ray imaging that corresponds to a gamma camera with a mobile collimator, which can be used in vivo, during surgical interventions for oncological patients for localizing regions of interest such as tumors or ganglia. The benefits are a much higher sensitivity, better image quality and, consequently, a dose reduction for the patient and medical staff. This novel approach is a practical solution to the overlapping problem which is inherent to multi-pinhole gamma camera imaging and single photon emission computed tomography and which translates into artifacts and/or image truncation in the final reconstructed image. The key concept consists in introducing a relative motion between the collimator and the detector. Moreover, this design could also be incorporated into most commercially available gamma camera devices, without any excessive additional requirements. We use Monte Carlo simulations to assess the feasibility of such a device, analyze three possible designs and compare their sensitivity, resolution and uniformity. We propose a final design of a gamma camera with a high sensitivity ranging from 0.001 to 0.006 cps/Bq, and a high resolution of 0.5-1.0 cm (FWHM), for source-to-detector distances of 4-10 cm. Additionally, this planar gamma camera provides information about the depth of source (with approximate resolution of 1.5 cm) and excellent image uniformity.


Assuntos
Câmaras gama , Tomografia Computadorizada de Emissão de Fóton Único , Artefatos , Estudos de Viabilidade , Humanos , Método de Monte Carlo , Imagens de Fantasmas
11.
Blood Cells Mol Dis ; 80: 102375, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31655394

RESUMO

BACKGROUND: Extracellular vesicles, have gained increasing attention for their application in drug delivery. Here, we developed a novel method for radiolabeling WBCs with 99mTc using RBC-derived extracellular vesicles -mimetics (EVMs), and monitored in vivo inflammation tracking of 99mTc-WBC using gamma camera in acute inflammation mouse model. METHODS: Engineered EVMs from RBCs were produced by a one-step extrusion method. RBC-EVMs were analyzed by NTA and TEM. Cells were labeled with 99mTc by using 99mTc-RBC-EVMs. Inflammation mice model was prepared and confirmed by 18F-FDG PET/CT. 99mTc-WBCs were injected in mice, and their biodistribution was analyzed by gamma camera. FINDING: The radiochemical purity of 99mTc-RBC-EVMs was 100%. The 99mTc-labeling did't affect the size and morphology. The 99mTc in the cytoplasm of RBC-EVMs was successfully confirmed by high angle annular dark field STEM (scanning transmission electron microscope). Cells were successfully labeled with 99mTc using 99mTc-RBC-EVMs, and the counts per minute was increased in dose- and time-dependent manners. The 18F-FDG PET/CT images confirmed establishment of acute inflammation (left mouse foot). 99mTc-WBCs showed higher uptake in the inflamed foot than non-inflamed foot. INTERPRETATION: This novel method for radiolabeling WBCs using RBC-EVMs. 99mTc labeling may be a feasible method to monitor the in vivo biodistribution of cells.


Assuntos
Eritrócitos/metabolismo , Vesículas Extracelulares/metabolismo , Leucócitos/metabolismo , Compostos Radiofarmacêuticos/metabolismo , Tecnécio/metabolismo , Animais , Rastreamento de Células , Modelos Animais de Doenças , Vesículas Extracelulares/ultraestrutura , Feminino , Inflamação/diagnóstico por imagem , Inflamação/etiologia , Inflamação/metabolismo , Camundongos , Imagem Molecular/métodos , Ratos , Coloração e Rotulagem , Frações Subcelulares , Distribuição Tecidual
12.
Circ J ; 84(10): 1818-1825, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-32893238

RESUMO

BACKGROUND: Sequential assessment using CT coronary angiography (coronary CT) and nuclear myocardial perfusion imaging (MPI) is considered an anatomical and functional evaluation of coronary artery disease (CAD). However, there can be unexpected radiation exposure. Hybrid MPI with stress-only nuclear MPI and rest CT-MPI using coronary CT may contribute to reducing the radiation dose in sequential assessment with nuclear MPI after coronary CT. We analyzed the diagnostic performance and total radiation dose of hybrid MPI for detection of significant CAD compared with sequential assessment using nuclear MPI after coronary CT.Methods and Results:The results for 101 patients who underwent coronary CT, nuclear MPI and invasive coronary angiography within 3 months of all imaging were analyzed. We calculated the summed difference score (SDS) from standard nuclear MPI and hybrid SDS from hybrid MPI, which revealed myocardial ischemia. The diagnostic performance of SDS and hybrid SDS for detecting significant CAD was analyzed using receiver-operating characteristic (ROC) curve analysis. We also compared the total radiation dose of both methods. The area under the ROC curve was not different between SDS and hybrid SDS (0.901 and 0.815, P=0.079). Total radiation dose of hybrid MPI was significantly lower than standard nuclear MPI with CT angiography (4.62 mSv vs. 9.72 mSv, P<0.0001). CONCLUSIONS: Hybrid MPI showed a precise diagnostic accuracy for significant CAD detection.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Teste de Esforço , Imagem de Perfusão do Miocárdio/métodos , Descanso , Adenosina/administração & dosagem , Idoso , Cardiotônicos/administração & dosagem , Confiabilidade dos Dados , Dobutamina/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Vasodilatadores/administração & dosagem
13.
J Appl Clin Med Phys ; 21(4): 80-86, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32277546

RESUMO

PURPOSE: Daily flood-field uniformity evaluation serves as the central element of nuclear medicine (NM) quality control (QC) programs. Uniformity images are traditionally analyzed using pixel value-based metrics, that is, integral uniformity (IU), which often fail to capture subtle structure and patterns caused by changes in gamma camera performance, requiring visual inspections which are subjective and time demanding. The goal of this project was to implement an advanced QC metrology for NM to effectively identify nonuniformity issues, and report issues in a timely manner for efficient correction prior to clinical use. The project involved the implementation of the program over a 2-year period at a multisite major medical institution. METHODS: Using a previously developed quantitative uniformity analysis metric, the structured noise index (SNI) [Nelson et al. (2014), \textit{J Nucl Med.}, \textbf{55}:169-174], an automated QC process was developed to analyze, archive, and report on daily NM QC uniformity images. Clinical implementation of the newly developed program ran in parallel with the manufacturer's reported IU-based QC program. The effectiveness of the SNI program was evaluated over a 21-month period using sensitivity and coefficient of variation statistics. RESULTS: A total of 7365 uniformity QC images were analyzed. Lower level SNI alerts were generated in 12.5% of images and upper level alerts in 1.7%. Intervention due to image quality issues occurred on 26 instances; the SNI metric identified 24, while the IU metric identified eight. The SNI metric reported five upper level alerts where no clinical engineering intervention was deemed necessary. CONCLUSION: An SNI-based QC program provides a robust quantification of the performance of gamma camera uniformity. It operates seamlessly across a fleet of multiple camera models and, additionally, provides effective workflow among the clinical staff. The reliability of this process could eliminate the need for visual inspection of each image, saving valuable time, while enabling quantitative analysis of inter- and intrasystem performance.


Assuntos
Medicina Nuclear/métodos , Medicina Nuclear/normas , Controle de Qualidade , Artefatos , Automação , Análise de Fourier , Câmaras gama , Humanos , Modelos Estatísticos , Distribuição Normal , Reconhecimento Automatizado de Padrão , Garantia da Qualidade dos Cuidados de Saúde , Cintilografia , Reprodutibilidade dos Testes
14.
J Appl Clin Med Phys ; 21(11): 205-214, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33142050

RESUMO

PURPOSE: We introduce an automated, quantitative image analysis package for gamma camera and single photon emission computed tomography quality control. Our focus was to produce consistent methods that are feasible in clinical settings and use standard phantoms. METHODS: Four gamma cameras were used to acquire planar images of four-quadrant bar phantoms and projection views of an American College of Radiology (ACR) phantom as part of a standard gamma camera quality control program. Images were sent to QC-Track® (Atirix Medical Systems, Inc., Minneapolis, MN, USA), which automatically placed predetermined regions of interest (ROIs) and performed analysis. For the bar phantom, a standard deviation (SD)-based modulation transfer function was calculated for a circular ROI in each quadrant. The bar widths at various MTF values were reported using linear interpolation as applicable. For the ACR phantom, the contrast-to-noise ratio (CNR) for each sphere, a modulation for each rods section, and a percent deviation for uniformity ROIs was calculated. Spheres corresponding to a CNR of 3, and the rod size at various modulations were also reported using linear interpolation. Visual analysis was performed by three medical physicists to evaluate interobserver variability and correlation to quantitative values. RESULTS: Analysis of the bar phantom showed predictable differences with changes in matrix size and bar width and showed consistency over similar acquisitions over the course of the study. Analysis of the ACR Phantom showed increasing CNR and modulation with increasing sphere and rod diameter, as expected. For both phantoms, quantitative values from linear interpolation correlated well with visual analysis. CONCLUSION: Our automated method for quantitative image analysis is consistent and shows increased precision and sensitivity when compared to standard visual methods. Thresholds correspond well with visual analysis and previous guidelines for observer visibility (e.g., Rose criterion), making our framework suitable for routine use in a nuclear medicine department.


Assuntos
Câmaras gama , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas , Controle de Qualidade
15.
J Xray Sci Technol ; 28(3): 461-470, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32145008

RESUMO

OBJECTIVE: Since in-house phantoms may provide effective quality control for gamma cameras in clinical settings, this study aims to assess an in-house phantom designed to perform quality control tests of a gamma camera using locally available, affordable materials. This is of particular importance in developing countries where scientific support may not be readily available. MATERIALS AND METHODS: The phantom was made from cylindrical plexiglass with a diameter of 230 mm and thickness of 60 mm. The phantom design was based on NEMA recommendations and only used materials that are locally available and generally accessible to most nuclear medicine departments and require minimal engineering instruction. RESULTS: The phantom demonstrated high levels of reliability and accuracy. The integral uniformity range was between 1.93% and 2.40%. The differential uniformity ranged between 1.48% and 1.70%. CONCLUSION: This work demonstrates that in-house phantoms are capable of monitoring gamma camera performance. This approach is particularly useful when scientific support is not easily accessible and when commercial phantoms are not readily available.


Assuntos
Câmaras gama/normas , Imagens de Fantasmas , Cintilografia , Desenho de Equipamento , Controle de Qualidade , Cintilografia/instrumentação , Cintilografia/normas , Reprodutibilidade dos Testes
16.
Eur J Nucl Med Mol Imaging ; 46(8): 1672-1677, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31044266

RESUMO

PURPOSE: To evaluate the feasibility of short whole-body bone scan acquisition times using a novel gamma camera with cadmium-zinc-telluride (CZT) semiconductor detectors. METHODS: We retrospectively enrolled 78 consecutive patients with prostate cancer who underwent bone scintigraphy using a whole-body gamma camera with CZT detectors. After acquisition of list-mode data with 180 s per bed position, anterior and posterior whole-body images were reconstructed using the first 5%, 10%, 25%, 50%, 75% and 100% of the list-mode data. Two experienced nuclear medicine physicians interpreted the images, and interrater agreement and the diagnostic value of the images were determined. Quantitative artificial neural network (ANN) values, bone scan indexes (BSI) and hotspot numbers (HsN) were also calculated by automated diagnostic software. RESULTS: Excellent interrater reliabilities of the visual assessments were obtained for the 100%, 75%, 50%, and 25% images (κ = 0.88, 0.88, 0.88 and 0.88, respectively). The 5% images also showed high diagnostic value (sensitivity 0.94, specificity 0.84 and accuracy 0.86). Intraclass correlation coefficients (ICC) between the 100% images and the reduced acquisition time images were evaluated in quantitative analyses, and excellent correlations were observed for ANN value in the 75% images (ICC 0.77), for BSI in all the reduced acquisition time images (75%, 50%, 25%, 10% and 5%; ICC 0.99, 0.99, 0.99, 0.96 and 0.75, respectively), and for HsN in the 75%, 50%, 25% and 10% images (ICC 0.99, 0.99, 0.98 and 0.90, respectively). CONCLUSION: Whole-body gamma cameras with CZT detectors have the potential to reduce image acquisition times and the dose of radioisotope injected for bone scans.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Câmaras gama/normas , Neoplasias da Próstata/patologia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Imagem Corporal Total/instrumentação , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/secundário , Cádmio , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Telúrio , Zinco
17.
Eur J Nucl Med Mol Imaging ; 46(3): 623-637, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30564849

RESUMO

PURPOSE: Sentinel lymph node biopsy is an essential staging tool in patients with clinically localized oral cavity squamous cell carcinoma. The harvesting of a sentinel lymph node entails a sequence of procedures with participation of specialists in nuclear medicine, radiology, surgery, and pathology. The aim of this document is to provide guidelines for nuclear medicine physicians performing lymphoscintigraphy for sentinel lymph node detection in patients with early N0 oral cavity squamous cell carcinoma. METHODS: These practice guidelines were written and have been approved by the European Association of Nuclear Medicine (EANM) and the International Atomic Energy Agency (IAEA) to promote high-quality lymphoscintigraphy. The final result has been discussed by distinguished experts from the EANM Oncology Committee, and national nuclear medicine societies. The document has been endorsed by the Society of Nuclear Medicine and Molecular Imaging (SNMMI). These guidelines, together with another two focused on Surgery and Pathology (and published in specialised journals), are part of the synergistic efforts developed in preparation for the "2018 Sentinel Node Biopsy in Head and Neck Consensus Conference". CONCLUSION: The present practice guidelines will help nuclear medicine practitioners play their essential role in providing high-quality lymphatic mapping for the care of early N0 oral cavity squamous cell carcinoma patients.


Assuntos
Carcinoma de Células Escamosas/patologia , Neoplasias Bucais/patologia , Medicina Nuclear , Guias de Prática Clínica como Assunto , Biópsia de Linfonodo Sentinela/métodos , Carcinoma de Células Escamosas/diagnóstico por imagem , Europa (Continente) , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Bucais/diagnóstico por imagem , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Proteção Radiológica
18.
J Nucl Cardiol ; 26(5): 1734-1742, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-29340989

RESUMO

BACKGROUND: Left ventricular (LV) ejection fraction (EF) during high dobutamine stress (HD) by real-time gated-SPECT myocardial perfusion imaging (MPI) on a cadmium-zinc-telluride (CZT) gamma camera was validated versus cardiac magnetic resonance imaging (CMR). METHODS AND RESULTS: After injecting 99mTc-tetrofosmin (320 MBq) in 50 patients (mean age 64 +/- 11 years), EF at rest and post-stress as well as relevant changes in EF at HD (ΔEF ≥ 5%) were assessed. CZT and CMR rest EF values yielded an excellent correlation and agreement (r = 0.96; P < 0.001; Bland-Altman limits of agreement (BA): + 0 to 14.8%). HD EF acquisition was feasible using CZT and correlated better to HD CMR EF than did post-stress CZT EF (r = 0.85 vs 0.76, respectively, all P < 0.001). Agreement in ΔEF detection between HD CMR and immediate post-stress CZT (reflecting standard acquisition using conventional SPECT camera unable to scan during stress) was 45%, while this increased to 85% with real-time HD CZT scan. CONCLUSION: Real-time ultrafast dobutamine gated-SPECT MPI with a CZT device is feasible and provides accurate measurements of HD LV performance.


Assuntos
Cádmio/química , Dobutamina/farmacologia , Ventrículos do Coração/diagnóstico por imagem , Movimento , Imagem de Perfusão do Miocárdio , Telúrio/química , Tomografia Computadorizada de Emissão de Fóton Único , Zinco/química , Idoso , Estudos de Viabilidade , Feminino , Câmaras gama , Ventrículos do Coração/anormalidades , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Compostos Organofosforados , Compostos de Organotecnécio , Reprodutibilidade dos Testes , Função Ventricular Esquerda
19.
J Nucl Cardiol ; 26(6): 1984-1991, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-29796975

RESUMO

BACKGROUND: In myocardial perfusion imaging (MPI), single-photon emission tomography (SPECT) soft-tissue attenuation by the abdomen, breasts, and lateral chest wall may create artifacts that mimic true perfusion defects. This may cause misdiagnosis of myocardial perfusion. The aim of the present study was to compare the localization, extent, and depth of attenuation artifacts in MPI SPECT for a multi-pinhole cadmium zinc telluride (CZT) camera vs a conventional gamma camera. METHODS: Phantom and patient measurements were performed using a CZT camera (GE NM 530c) and a conventional gamma camera (GE Ventri). All images were attenuation corrected with externally acquired low-dose computed tomography. The localization, extent, and depth of the attenuation artifact were quantified by comparing attenuation-corrected and non-attenuation-corrected images. RESULTS: Attenuation artifacts were shifted from the inferolateral wall to the lateral wall using the CZT camera compared to a conventional camera in both the patient and the phantom. The extent of the attenuation artifact was significantly larger for the CZT camera compared to the conventional camera (23 ± 5% vs 15 ± 5%, P < .001) for patients and the result was similar for the phantom (28% vs 19%). Furthermore, the depth of the attenuation artifact (percent of maximum counts) was less pronounced for the CZT camera than for the conventional camera, both for phantom measurements (73% vs 67%) and patients (72 ± 3% vs 68 ± 4%, P < .001). CONCLUSIONS: Attenuation artifacts are found in different locations to different extents and depths when using a CZT camera vs a conventional gamma camera for MPI SPECT. This should be taken into consideration when evaluating MPI SPECT studies to avoid misinterpretation of myocardial perfusion distribution.


Assuntos
Câmaras gama , Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Miocárdio/patologia , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Idoso de 80 Anos ou mais , Artefatos , Cádmio , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica , Perfusão , Imagens de Fantasmas , Telúrio , Tomografia Computadorizada por Raios X , Zinco
20.
J Nucl Cardiol ; 26(1): 236-245, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-28462467

RESUMO

BACKGROUND: Data regarding cardiac cadmium-zinc-telluride (CZT)-specific augmented databases and their impact on CT-based attenuation correction (AC) perfusion scores in myocardial perfusion imaging (MPI) were obtained on a multiple-pinhole CZT SPECT/CT. METHODS AND RESULTS: Summed stress (SSS) and rest scores (SRS) were measured using automated software in three independent patient groups: group 1 (n = 80) underwent MPI on both CZT and conventional sodium iodide (NaI) devices, group 2 (n = 80) with low coronary artery disease likelihood and normal MPI provided reference CZT databases; and group 3 (n = 152) served to compare AC and non-AC (NAC) scores on CZT. Group 1 CZT and NaI scores gave a significant 1:1 linear correlation for CZT scores referenced to the custom database vs NaI scores referenced to the default database, but these were not concordant when CZT scores were referenced to the default database. AC significantly decreased average SSS and SRS in men vs NAC, 4.29 ± 6.30 vs 5.37 ± 7.26 (P < 0.001) and 2.37 ± 4.72 vs 3.13 ± 5.85 (P < 0.001), but not in women, 2.28 ± 3.42 vs 2.28 ± 3.08 (p NS) and 0.46 ± 1.51 vs 0.61 ± 1.86, (p NS), respectively. CONCLUSIONS: Specifically designed databases for solid-state CZT cardiac SPECT provide accurate quantitation of perfusion scores concordant with those previously validated for conventional SPECT. AC and NAC CZT scores differed significantly, especially in men.


Assuntos
Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Cádmio , Doença da Artéria Coronariana/diagnóstico por imagem , Bases de Dados Factuais , Feminino , Câmaras gama , Humanos , Masculino , Pessoa de Meia-Idade , Perfusão , Processamento de Sinais Assistido por Computador , Software , Telúrio , Zinco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA