Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 24(2): e13835, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36316723

RESUMO

This study aims to evaluate the effect of different air computed tomography (CT) numbers of the image value density table (IVDT) on the retrospective dose calculation of head-and-neck (HN) radiotherapy using TomoTherapy megavoltage CT (MVCT) images. The CT numbers of the inside and outside air and each tissue-equivalent plug of the "Cheese" phantom were obtained from TomoTherapy MVCT. Two IVDTs with different air CT numbers were created and applied to MVCT images of the HN anthropomorphic phantom and recalculated by Planned Adaptive to verify dose distribution. We defined the recalculation dose with MVCT images using both inside and outside air of the IVDT as IVDT MVCT inair ${\mathrm{IVDT}}_{\mathrm{MVCT}}^{\mathrm{inair}}$ and IVDT MVCT outair ${\mathrm{IVDT}}_{\mathrm{MVCT}}^{\mathrm{outair}}$ , respectively. Treatment planning doses calculated on kVCT images were compared with those calculated on MVCT images using two different IVDT tables, namely, IVDT MVCT inair ${\mathrm{IVDT}}_{\mathrm{MVCT}}^{\mathrm{inair}}$ and IVDT MVCT outair ${\mathrm{IVDT}}_{\mathrm{MVCT}}^{\mathrm{outair}}$ . The difference between average MVCT numbers ±1 standard deviation on inside and outside air of the calibration phantom was 65 ± 36 HU. This difference in MVCT number of air exceeded the recommendation lung tolerance for dose calculation error of 2%. The dose differences between the planning target volume (PTV): D98% , D50% , D2% and the organ at risk (OAR): Dmax , Dmean recalculated by IVDT MVCT inair ${\mathrm{IVDT}}_{\mathrm{MVCT}}^{\mathrm{inair}}$ and IVDT MVCT outair ${\mathrm{IVDT}}_{\mathrm{MVCT}}^{\mathrm{outair}}$ using MVCT images were a maximum of 0.7% and 1.2%, respectively. Recalculated doses to the PTV and OAR with MVCT showed that IVDT MVCT outair ${\mathrm{IVDT}}_{\mathrm{MVCT}}^{\mathrm{outair}}$ was 0.5%-0.7% closer to the kVCT treatment planning dose than IVDT MVCT inair ${\mathrm{IVDT}}_{\mathrm{MVCT}}^{\mathrm{inair}}$ . This study showed that IVDT MVCT outair ${\mathrm{IVDT}}_{\mathrm{MVCT}}^{\mathrm{outair}}$ was more accurate than IVDT MVCT inair ${\mathrm{IVDT}}_{\mathrm{MVCT}}^{\mathrm{inair}}$ in recalculating the dose HN cases of MVCT using TomoTherapy.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico
2.
Phys Med ; 31(2): 146-51, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25595131

RESUMO

PURPOSE: We aimed to identify the most accurate combination of phantom and protocol for image value to density table (IVDT) on volume-modulated arc therapy (VMAT) dose calculation based on kV-Cone-beam CT imaging, for head and neck (H&N) and pelvic localizations. METHODS: Three phantoms (Catphan(®)600, CIRS(®)062M (inner phantom for head and outer phantom for body), and TomoTherapy(®) "Cheese" phantom) were used to create IVDT curves of CBCT systems with two different CBCT protocols (Standard-dose Head and Standard Pelvis). Hounsfield Unit (HU) time stability and repeatability for a single On-Board-Imager (OBI) and compatibility of two distinct devices were assessed with Catphan(®)600. Images from the anthropomorphic phantom CIRS ATOM(®) for both CT and CBCT modalities were used for VMAT dose calculation from different IVDT curves. Dosimetric indices from CT and CBCT imaging were compared. RESULTS: IVDT curves from CBCT images were highly different depending on phantom used (up to 1000 HU for high densities) and protocol applied (up to 200 HU for high densities). HU time stability was verified over seven weeks. A maximum difference of 3% on the dose calculation indices studied was found between CT and CBCT VMAT dose calculation across the two localizations using appropriate IVDT curves. One IVDT curve per localization can be established with a bi-monthly verification of IVDT-CBCT. CONCLUSIONS: The IVDT-CBCTCIRS-Head phantom with the Standard-dose Head protocol was the most accurate combination for dose calculation on H&N CBCT images. For pelvic localizations, the IVDT-CBCTCheese established with the Standard Pelvis protocol provided the best accuracy.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Pelve/diagnóstico por imagem , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Adulto , Humanos , Masculino , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA