Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Magn Reson Med ; 89(5): 1809-1824, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36511247

RESUMO

PURPOSE: We investigated the correlation, reproducibility, and effect of white matter fiber orientation for three myelin-sensitive MRI techniques: magnetization transfer ratio (MTR), inhomogeneous magnetization transfer ratio (ihMTR), and gradient and spin echo-derived myelin water fraction (MWF). METHODS: We measured the three metrics in 17 white and three deep grey matter regions in 17 healthy adults at 3 T. RESULTS: We found a strong correlation between ihMTR and MTR (r = 0.70, p < 0.001) and ihMTR and MWF (r = 0.79, p < 0.001), and a weaker correlation between MTR and MWF (r = 0.54, p < 0.001). The dynamic range in white matter was greatest for MWF (2.0%-27.5%), followed by MTR (14.4%-23.2%) and then ihMTR (1.2%-5.4%). The average scan-rescan coefficient of variation for white matter regions was 0.6% MTR, 0.3% ihMTR, and 0.7% MWF in metric units; however, when adjusted by the dynamic range, these became 6.3%, 6.1% and 2.8%, respectively. All three metrics varied with fiber direction: MWF and ihMTR were lower in white matter fibers perpendicular to B0 by 6% and 1%, respectively, compared with those parallel, whereas MTR was lower by 0.5% at about 40°, with the highest values at 90°. However, separating the apparent orientation dependence by white matter region revealed large dissimilarities in the trends, suggesting that real differences in myelination between regions are confounding the apparent orientation dependence measured using this method. CONCLUSION: The strong correlation between ihMTR and MWF suggests that these techniques are measuring the same myelination; however, the larger dynamic range of MWF may provide more power to detect small differences in myelin.


Assuntos
Bainha de Mielina , Substância Branca , Humanos , Adulto , Reprodutibilidade dos Testes , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Substância Branca/diagnóstico por imagem , Água , Biomarcadores
2.
Magn Reson Med ; 89(2): 550-564, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36306334

RESUMO

PURPOSE: To evaluate the benefits of fast spin echo (FSE) imaging over rapid gradient-echo (RAGE) for magnetization-prepared inhomogeneous magnetization transfer (ihMT) imaging. METHODS: A 3D FSE sequence was modified to include an ihMT preparation (ihMT-FSE) with an optional CSF suppression based on an inversion-recovery (ihMT-FLAIR). After numeric simulations assessing SNR benefits of FSE and the potential impact of an additional inversion-recovery, ihMT-RAGE, ihMT-FSE, and ihMT-FLAIR sequences were compared in a group of six healthy volunteers, evaluating image quality, thermal, and physiological noise as well as quantification using an ihMT saturation (ihMTsat) approach. A preliminary exploration in the cervical spinal cord was also conducted in a group of three healthy volunteers. RESULTS: Several fold improvements in thermal SNR were observed with ihMT-FSE in agreement with numerical simulations. However, we observed significantly higher physiological noise in ihMT-FSE compared to ihMT-RAGE that was mitigated in ihMT-FLAIR, which provided the best total SNR (+74% and +49% compared to ihMT-RAGE in the white and gray matter, P ≤ 0.004). IhMTsat quantification was successful in all cases with strong correlation between all sequences (r2 > 0.75). Early experiments showed potential for spinal cord imaging. CONCLUSIONS: FSE generally offers higher SNR compared to gradient-echo based acquisitions for magnetization-prepared contrasts as illustrated here in the case of ihMT. However, physiological noise has a significant effect, but an inversion-recovery-based CSF suppression was shown to be efficient in mitigating effects of CSF motion.


Assuntos
Substância Cinzenta , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Substância Cinzenta/diagnóstico por imagem , Meios de Contraste , Medula Espinal/diagnóstico por imagem , Movimento (Física)
3.
Magn Reson Med ; 90(3): 875-893, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37154400

RESUMO

PURPOSE: To demonstrate the bias in quantitative MT (qMT) measures introduced by the presence of dipolar order and on-resonance saturation (ONRS) effects using magnetization transfer (MT) spoiled gradient-recalled (SPGR) acquisitions, and propose changes to the acquisition and analysis strategies to remove these biases. METHODS: The proposed framework consists of SPGR sequences prepared with simultaneous dual-offset frequency-saturation pulses to cancel out dipolar order and associated relaxation (T1D ) effects in Z-spectrum acquisitions, and a matched quantitative MT (qMT) mathematical model that includes ONRS effects of readout pulses. Variable flip angle and MT data were fitted jointly to simultaneously estimate qMT parameters (macromolecular proton fraction [MPF], T2,f , T2,b , R, and free pool T1 ). This framework is compared with standard qMT and investigated in terms of reproducibility, and then further developed to follow a joint single-point qMT methodology for combined estimation of MPF and T1 . RESULTS: Bland-Altman analyses demonstrated a systematic underestimation of MPF (-2.5% and -1.3%, on average, in white and gray matter, respectively) and overestimation of T1 (47.1 ms and 38.6 ms, on average, in white and gray matter, respectively) if both ONRS and dipolar order effects are ignored. Reproducibility of the proposed framework is excellent (ΔMPF = -0.03% and ΔT1 = -19.0 ms). The single-point methodology yielded consistent MPF and T1 values with respective maximum relative average bias of -0.15% and -3.5 ms found in white matter. CONCLUSION: The influence of acquisition strategy and matched mathematical model with regard to ONRS and dipolar order effects in qMT-SPGR frameworks has been investigated. The proposed framework holds promise for improved accuracy with reproducibility.


Assuntos
Imageamento por Ressonância Magnética , Substância Branca , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Substância Branca/diagnóstico por imagem , Substância Cinzenta , Modelos Teóricos , Prótons , Substâncias Macromoleculares , Encéfalo/diagnóstico por imagem
4.
Magn Reson Med ; 88(1): 332-340, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35344613

RESUMO

PURPOSE: Inhomogeneous magnetization transfer (ihMT) MRI is uniquely sensitive to myelin with lipids as a primary source of its contrast. In this study, we investigated whether ihMT can detect white matter structures in the hypomyelinated shiverer mouse brain, a model of dysmyelination. METHODS: Conventional MT and ihMT images were acquired from ex vivo Rag2-/- control and shiverer mouse brains at 7T using previously reported optimized saturation parameters. RESULTS: ihMT ratio (ihMTR) maps revealed hypomyelinated corpus callosum in the shiverer mouse brain, whereas conventional MT ratio (MTR) maps showed no clear contrast. The ihMTR values of the corpus callosum in the shiverer mice were reduced by approximately 40% compared to controls, but remained significantly higher than the ihMTR values of the cortex. CONCLUSION: The finding further confirms ihMT's high myelin specificity and suggests its use as a marker to detect early myelination or myelin repair.


Assuntos
Substância Branca , Animais , Encéfalo/diagnóstico por imagem , Córtex Cerebral , Imageamento por Ressonância Magnética/métodos , Camundongos , Bainha de Mielina/química , Substância Branca/diagnóstico por imagem
5.
Magn Reson Med ; 87(3): 1346-1359, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34779020

RESUMO

PURPOSE: To minimize the sensitivity of inhomogeneous magnetization transfer gradient-echo (ihMT-GRE) imaging to radiofrequency (RF) transmit field ( B1+ ) inhomogeneities at 3 T. METHODS: The ihMT-GRE sequence was optimized by varying the concentration of the RF saturation energy over time, obtained by increasing the saturation pulse power while extending the sequence repetition time (TR). Different protocols were tested using numerical simulations and human in vivo experiments in the brain white matter (WM) of healthy subjects at 3 T. The sensitivity of the ihMT ratio (ihMTR) to B1+ variations was investigated by comparing measurements obtained at nominal transmitter adjustments and following a 20% global B1+ drop. The resulting relative variations (δihMTR ) were evaluated voxelwise as a function of the local B1+ distribution. The reproducibility of the protocol providing minimal B1+ bias was assessed in a test-retest experiment. RESULTS: In line with simulations, ihMT-GRE experiments conducted at high concentration of the RF energy over time demonstrated strong reduction of the B1+ inhomogeneity effects in the human WM. Under the optimal conditions of 350-ms TR and 3-µT root mean square (RMS) saturation power, 73% of all WM voxels presented δihMTR below 10%. Reproducibility analysis yielded a close-to-zero systematic bias (ΔihMTR = -0.081%) and a high correlation (ρ² = 0.977) between test and retest experiments. CONCLUSION: Concentrating RF saturation energy in ihMT-GRE sequences mitigates the sensitivity of the ihMTR to B1+ variations and allows for clinical-ready ihMT imaging at 3 T. This feature is of particular interest for high and ultra-high field applications.


Assuntos
Imageamento por Ressonância Magnética , Substância Branca , Encéfalo/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Ondas de Rádio , Reprodutibilidade dos Testes
6.
Neuroimage ; 236: 118046, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33848620

RESUMO

PURPOSE: The promise of inhomogeneous magnetization transfer (ihMT) as a new myelin imaging method was studied in ex vivo human brain tissue and in relation to myelin water fraction (MWF). The temperature dependence of both methods was characterized, as well as their correspondence with a histological measure of myelin content. Unfiltered and filtered ihMT protocols were studied by adjusting the saturation scheme to preserve or attenuate signal from tissue with short dipolar relaxation time T1D. METHODS: ihMT ratio (ihMTR) and MWF maps were acquired at 7 T from formalin-fixed human brain samples at 22.5 °C, 30 °C and 37 °C. The impact of temperature on unfiltered ihMTR, filtered ihMTR and MWF was investigated and compared to myelin basic protein staining. RESULTS: Unfiltered ihMTR exhibited no temperature dependence, whereas filtered ihMTR increased with increasing temperature. MWF decreased at higher temperature, with an increasing prevalence of areas where the myelin water signal was unreliably determined, likely related to a reduction in T2 peak separability at higher temperatures ex vivo. MWF and ihMTR showed similar per-sample correlation with myelin staining at room temperature. At 37 °C, filtered ihMTR was more strongly correlated with myelin staining and had increased dynamic range compared to unfiltered ihMTR. CONCLUSIONS: Given the temperature dependence of filtered ihMT, increased dynamic range, and strong myelin specificity that persists at higher temperatures, we recommend carefully controlled temperatures close to 37 °C for filtered ihMT acquisitions. Unfiltered ihMT may also be useful, due to its independence from temperature, higher amplitude values, and sensitivity to short T1D components. Ex vivo myelin water imaging should be performed at room temperature, to avoid fitting issues found at higher temperatures.


Assuntos
Água Corporal/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina , Neuroimagem/métodos , Substância Branca/anatomia & histologia , Substância Branca/diagnóstico por imagem , Idoso , Biomarcadores , Feminino , Formaldeído , Humanos , Temperatura , Fixação de Tecidos
7.
Neuroimage ; 225: 117442, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-33039620

RESUMO

BACKGROUND: Myelin specific imaging techniques to characterize white matter in demyelinating diseases such as multiple sclerosis (MS) have become an area of increasing focus. Gray matter myelination is an important marker of cortical microstructure, and its impairment is relevant in progressive MS. However, its assessment is challenging due to its thin layers. While myelin water imaging and ultra-short TE imaging have not yet been implemented to assess cortical myeloarchitecture, magnetization transfer (MT) shows promise. A recent development of the MT technique, ihMT, has demonstrated greater myelin sensitivity/specificity. Here we implemented a 3D ihMT acquisition and analysis to characterize cortical gray matter myeloarchitecture. METHODS: 20 young healthy volunteers were imaged with a 3D ihMTRAGE sequence and quantitative metrics of ihMT (ihMTsat), and dual frequency-offset MT (dual MTsat) were calculated. Cortical surface-based analysis of ihMTsat and dual MTsat were performed and compared. We also compared the cortical ihMTsat map to a cortical surface-based map of T1-weighted images (T1w), defined as a proxy of myelin content. RESULTS: Cortical ihMTsat and dual MTsat maps were in qualitative agreement with previous work and the cortical T1w map, showing higher values in primary cortices and lower values in the insula. IhMTsat and dual MTsat were significantly correlated but with important regional differences. The ratio ihMTsat/dual MTsat highlighted higher ihMTsat values in the primary cortices and sulci. CONCLUSION: ihMTsat, a quantitative metric of ihMT, can be reliably measured in cortical gray matter and shows unique contrast between cortical regions.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Substância Branca/diagnóstico por imagem , Adulto Jovem
8.
Magn Reson Med ; 86(4): 2192-2207, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33956348

RESUMO

PURPOSE: In this work, we propose that Δ B1+ -induced errors in magnetization transfer (MT) saturation (MTsat ) maps can be corrected with use of an R1 and B1+ map and through numerical simulations of the sequence. THEORY AND METHODS: One healthy subject was scanned at 3.0T using a partial quantitative MT protocol to estimate the relationship between observed R1 (R1,obs ) and apparent bound pool size ( M0,appB ) in the brain. MTsat values were simulated for a range of B1+ , R1,obs , and M0,appB . An equation was fit to the simulated MTsat , then a linear relationship between R1,obs and M0,appB was generated. These results were used to generate correction factor maps for the MTsat acquired from single-point data. The proposed correction was compared to an empirical correction factor with different MT-preparation schemes. RESULTS: M0,appB was highly correlated with R1,obs (r > 0.96), permitting the use of R1,obs to estimate M0,appB for B1+ correction. All B1+ corrected MTsat maps displayed a decreased correlation with B1+ compared to uncorrected MTsat and MTsat corrected with an empirical factor in the corpus callosum. There was good agreement between the proposed approach and the empirical correction with radiofrequency saturation at 2 kHz, with larger deviations seen when using saturation pulses further off-resonance and in inhomogeneous (ih) MTsat maps. CONCLUSION: The proposed correction decreases the dependence of MTsat on B1+ inhomogeneities. Furthermore, this flexible framework permits the use of different saturation protocols, making it useful for correcting B1+ inhomogeneities in ihMT.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Ondas de Rádio
9.
Magn Reson Med ; 84(6): 2964-2980, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32602958

RESUMO

PURPOSE: To demonstrate the feasibility of integrating the magnetization transfer (MT) preparations required for inhomogeneous MT (ihMT) within an MPRAGE-style acquisition. Such a sequence allows for reduced power deposition and easy inclusion of other modules. METHODS: An ihMT MPRAGE-style sequence (ihMTRAGE) was initially simulated to investigate acquisition of the 3D ihMT data sequentially, or in an interleaved manner. The ihMTRAGE sequence was implemented on a 3T clinical scanner to acquire ihMT data from the brain and spine. RESULTS: Both simulations and in vivo data provided an ihMT signal that was significantly greater using a sequential ihMTRAGE acquisition, compared with an interleaved implementation. Comparison with a steady-state ihMT acquisition (defined as having one MT RF pulse between successive acquisition modules) demonstrated how ihMTRAGE allows for a reduction in average power deposition, or greater ihMT signal at equal average power deposition. Inclusion of a prospective motion-correction module did not significantly affect the ihMT signal obtained from regions of interest in the brain. The ihMTRAGE acquisition allowed combination with a spatial saturation module to reduce phase wrap artifacts in a cervical spinal cord acquisition. CONCLUSIONS: Use of preparations necessary for ihMT experiments within an MPRAGE-style sequence provides a useful alternative for acquiring 3D ihMT data. Compared with our steady-state implementation, ihMTRAGE provided reduced power deposition, while allowing use of the maximum intensity from off-resonance RF pulses. The 3D ihMTRAGE acquisition allowed combination of other modules with the preparation necessary for ihMT experiments, specifically motion compensation and spatial saturation modules.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Imageamento Tridimensional , Estudos Prospectivos
10.
Neuroimage ; 199: 289-303, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31141736

RESUMO

Inhomogeneous Magnetization Transfer (ihMT) is a development from the MT MRI technique. IhMT can be considered as a dipolar order relaxation time (T1D) weighted imaging modality whose signal has shown an enhanced selectivity for myelin-rich structures. However, a formal validation of the ihMT sensitivity relative to a gold standard myelin density measurement has not yet been reported. To address this need, we compared ihMT MRI with green fluorescence protein (GFP) microscopy, in a study performed on genetically-modified plp-GFP mice, considered as a reference technique for myelin-content assessment. Various ihMT protocols consisting of variable T1D-filtering and radiofrequency power temporal distributions, were used for comparison with fluorescence microscopy. Strong and significant linear relationships (r2 (0.87-0.96), p < 0.0001) were found between GFP and ihMT ratio signals across brain regions for all tested protocol variants. Conventional MT ratios showed weaker correlations (r2 (0.24-0.78), p ≤ 0.02) and a much larger signal fraction unrelated to myelin, hence corresponding to a much lower specificity for myelin. T1D-filtering reduced the ihMT signal fraction not attributed to myelin by almost twofold relative to zero filtering suggesting that at least half of the unrelated signal has a substantially shorter T1D than myelin. Overall, these results strongly support the sensitivity of ihMT to myelin content.


Assuntos
Substância Cinzenta/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Microscopia de Fluorescência/normas , Bainha de Mielina , Substância Branca/diagnóstico por imagem , Animais , Interpretação Estatística de Dados , Imageamento por Ressonância Magnética/métodos , Camundongos , Camundongos Endogâmicos C57BL , Sensibilidade e Especificidade
11.
Neuroimage ; 182: 343-350, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-28916179

RESUMO

Sensitive and specific biomarkers of myelin can help define baseline brain health and development, identify and monitor disease pathology, and evaluate response to treatment where myelin content is affected. Diffusion measures such as radial diffusivity (RD) are commonly used to assess myelin content, but are not specific to myelin. Inhomogeneous magnetization transfer (ihMT) and multicomponent driven equilibrium single-pulse observation of T1 and T2 (mcDESPOT) offer quantitative parameters (qihMT and myelin volume fraction/VFm, respectively) which are suggested to have improved sensitivity to myelin. We compared RD, qihMT, and VFm in a cohort of 23 healthy children aged 8-13 years to evaluate the similarities and differences across these measures. All 3 measures were significantly related across brain voxels, but VFm and qihMT were significantly more strongly correlated (qihMT-VFm r = 0.89) than either measure was with RD (RD-qihMT r = -0.66, RD-VFm r = -0.74; all p < 0.001). Mean parameters differed in several regions, especially in subcortical gray matter. These differences can likely be explained by unique sensitivities of each measure to non-myelin factors, such as crossing fiber geometry, axonal packing, fiber orientation, glial density, or magnetization transfer effects in a voxel. We also observed an orientation dependence of qihMT in white matter, such that qihMT decreased as fiber orientation went from parallel to perpendicular to B0. All measures appear to be sensitive to myelin content, though qihMT and VFm appear to be more specific to it than RD. Scan time, noise tolerance, and resolution requirements may inform researchers of the appropriate measure to choose for a specific application.


Assuntos
Desenvolvimento Infantil , Imagem de Tensor de Difusão/métodos , Substância Cinzenta/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Bainha de Mielina , Substância Branca/diagnóstico por imagem , Adolescente , Fatores Etários , Criança , Feminino , Humanos , Masculino
12.
Neuroimage ; 182: 128-135, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-29208570

RESUMO

Magnetization transfer contrast has yielded insight into brain tissue microstructure changes across the lifespan and in a range of disorders. This progress has been aided by the development of quantitative magnetization transfer imaging techniques able to extract intrinsic properties of the tissue that are independent of the specifics of the data acquisition. While the tissue properties extracted by these techniques do not map directly onto specific cellular structures or pathological processes, a growing body of work from animal models and histopathological correlations aids the in vivo interpretation of magnetization transfer properties of tissue. This review examines the biophysical models that have been developed to describe magnetization transfer contrast in tissue as well as the experimental evidence for the biological interpretation of magnetization transfer data in health and disease.


Assuntos
Substância Cinzenta , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Substância Branca , Animais , Substância Cinzenta/anatomia & histologia , Substância Cinzenta/diagnóstico por imagem , Humanos , Substância Branca/anatomia & histologia , Substância Branca/diagnóstico por imagem
13.
Magn Reson Med ; 79(5): 2607-2619, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28940355

RESUMO

PURPOSE: To implement, characterize, and optimize an interleaved inhomogeneous magnetization transfer (ihMT) gradient echo sequence allowing for whole-brain imaging within a clinically compatible scan time. THEORY AND METHODS: A general framework for ihMT modelling was developed based on the Provotorov theory of radiofrequency saturation, which accounts for the dipolar order underpinning the ihMT effect. Experimental studies and numerical simulations were performed to characterize and optimize the ihMT-gradient echo dependency with sequence timings, saturation power, and offset frequency. The protocol was optimized in terms of maximum signal intensity and the reproducibility assessed for a nominal resolution of 1.5 mm isotropic. All experiments were performed on healthy volunteers at 1.5T. RESULTS: An important mechanism driving signal optimization and leading to strong ihMT signal enhancement that relies on the dynamics of radiofrequency energy deposition has been identified. By taking advantage of the delay allowed for readout between ihMT pulse bursts, it was possible to boost the ihMT signal by almost 2-fold compared to previous implementation. Reproducibility of the optimal protocol was very good, with an intra-individual error < 2%. CONCLUSION: The proposed sensitivity-boosted and time-efficient steady-state ihMT-gradient echo sequence, implemented and optimized at 1.5T, allowed robust high-resolution 3D ihMT imaging of the whole brain within a clinically compatible scan time. Magn Reson Med 79:2607-2619, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Simulação por Computador , Feminino , Análise de Fourier , Humanos , Masculino , Adulto Jovem
14.
Magn Reson Med ; 78(4): 1362-1372, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-27859618

RESUMO

PURPOSE: This paper describes a technique that can be used in vivo to measure the dipolar relaxation time, T1D , of macromolecular protons contributing to magnetization transfer (MT) in tissues and to produce quantitative T1D maps. THEORY AND METHODS: The technique builds upon the inhomogeneous MT (ihMT) technique that is particularly sensitive to tissue components with long T1D . A standard ihMT experiment was altered to introduce a variable time for switching between positive and negative offset frequencies for RF saturation. A model for the dependence of ihMT was developed and used to fit data acquired in vivo. RESULTS: Application of the method to images from brains of healthy volunteers produced values of T1D = (5.9 ± 1.2) ms in gray matter and T1D = (6.2 ± 0.4) ms in white matter regions and provided maps of the T1D parameter. CONCLUSION: The model and experiments described provide access to a new relaxation characteristic of tissue with potentially unique diagnostic information. Magn Reson Med 78:1362-1372, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Mapeamento Encefálico/métodos , Substância Cinzenta/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Humanos , Bainha de Mielina/química , Imagens de Fantasmas , Adulto Jovem
15.
Magn Reson Med ; 77(2): 581-591, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26959278

RESUMO

PURPOSE: Inhomogeneous magnetization transfer (ihMT) shows great promise for specific imaging of myelinated tissues. Whereas the ihMT technique has been previously applied in brain applications, the current report presents a strategy for cervical spinal cord (SC) imaging free of cerebrospinal fluid (CSF) pulsatility artifacts. METHODS: A pulsed ihMT preparation was combined with a single-shot HASTE readout. Electrocardiogram (ECG) synchronization was used to acquire all images during the quiescent phase of SC motion. However ihMT signal quantification errors may occur when a variable recovery delay is introduced in the sequence as a consequence of variable cardiac cycle. A semiautomatic retrospective correction algorithm, based on repetition time (TR) -matching, is proposed to correct for signal variations of long T1 -components (e.g., CSF). RESULTS: The proposed strategy combining ECG synchronization and retrospective data pairing led to clean SC images free of CSF artifacts. Lower variability of the ihMT metrics were obtained with the correction algorithm, and allowed for shorter TR to be used, hence improving signal-to-noise ratio efficiency. CONCLUSION: The proposed methodology enabled faster acquisitions, while offering robust ihMT quantification and exquisite SC image quality. This opens great perspectives for widening the in vivo characterization of SC physiopathology using MRI, such as studying white matter tracts microstructure or impairment in degenerative pathologies. Magn Reson Med 77:581-591, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Artefatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Líquido Cefalorraquidiano/citologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Medula Espinal/anatomia & histologia , Adulto , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
NMR Biomed ; 30(12)2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28926131

RESUMO

In this preliminary study, our objective was to investigate the potential of high-resolution anatomical imaging, diffusion tensor imaging (DTI) and conventional/inhomogeneous magnetization transfer imaging [magnetization transfer (MT)/inhomogeneous magnetization transfer (ihMT)] at 3 T, analyzed with template-extracted regions of interest, to measure the atrophy and structural changes of white (WM) and gray (GM) matter spinal cord (SC) occurring in patients with amyotrophic lateral sclerosis (ALS). Ten patients with ALS and 20 age-matched healthy controls were recruited. SC GM and WM areas were automatically segmented using dedicated templates. Atrophy indices were evaluated from T2 *-weighted images at each vertebral level from cervical C1 to C6. DTI and ihMT metrics were quantified within the corticospinal tract (CST), posterior sensory tract (PST) and anterior GM (aGM) horns at the C2 and C5 levels. Clinical disabilities of patients with ALS were evaluated using the Revised ALS Functional Rating Scale, upper motor neuron (UMN) and Medical Research Council scorings, and correlated with MR metrics. Compared with healthy controls, GM and WM atrophy was observed in patients with ALS, especially at lower cervical levels, where a strong correlation was also observed between GM atrophy and the UMN score (R = -0.75, p = 0.05 at C6). Interestingly, a significant decrease in ihMT ratio was found in all regions of interest (p < 0.0008), fractional anisotropy (FA) and MT ratios decreased significantly in CST, especially at C5 (p < 0.005), and λ// (axial diffusivity) decreased significantly in CST (p = 0.0004) and PST (p = 0.003) at C2. Strong correlations between MRI metrics and clinical scores were also found (0.47 < |R| < 0.87, p < 0.05). Altogether, these preliminary results suggest that high-resolution anatomical imaging and ihMT imaging, in addition to DTI, are valuable for the characterization of SC tissue impairment in ALS. In this study, in addition to an important SC WM demyelination, we also observed, for the first time in ALS, impairments of cervical aGM.


Assuntos
Esclerose Lateral Amiotrófica/diagnóstico por imagem , Vértebras Cervicais/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Adulto , Idoso , Feminino , Substância Cinzenta/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Tratos Piramidais/diagnóstico por imagem , Substância Branca/diagnóstico por imagem
17.
NMR Biomed ; 30(6)2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28195663

RESUMO

A pulsed inhomogeneous magnetization transfer (ihMT)-prepared fast imaging sequence was implemented at 11.75 T for preclinical studies on mouse central nervous system. A strategy based on filtering the ihMT signal originating from short dipolar relaxation time (T1D ) components is proposed. It involves increasing the repetition time of consecutive radiofrequency (RF) pulses of the dual saturation and allows improved signal specificity for long T1D myelinated structures. Furthermore, frequency offset, power and timing saturation parameters were adjusted to optimize the ihMT sensitivity. The optimization of the ihMT sensitivity, whilst preserving the strong specificity for the long T1D component of myelinated tissues, allowed measurements of ihMT ratios on the order of 4-5% in white matter (WM), 2.5% in gray matter (GM) and 1-1.3% in muscle. This led to high relative ihMT contrasts between myelinated tissues and others (~3-4 between WM and muscle, and ≥2 between GM and muscle). Conversely, higher ihMT ratios (~6-7% in WM) could be obtained using minimal T1D filtering achieved with short saturation pulse repetition time or cosine-modulated pulses for the dual-frequency saturation. This study represents a first stage in the process of validating ihMT as a myelin biomarker by providing optimized ihMT preclinical sequences, directly transposable and applicable to other preclinical magnetic fields and scanners. Finally, ihMT ratios measured in various central nervous system areas are provided for future reference.


Assuntos
Meios de Contraste/química , Imageamento por Ressonância Magnética/métodos , Animais , Sistema Nervoso Central/anatomia & histologia , Feminino , Processamento de Imagem Assistida por Computador , Camundongos Endogâmicos C57BL , Fatores de Tempo
18.
NMR Biomed ; 29(6): 817-32, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27100385

RESUMO

Being able to finely characterize the spinal cord (SC) microstructure and its alterations is a key point when investigating neural damage mechanisms encountered in different central nervous system (CNS) pathologies, such as multiple sclerosis, amyotrophic lateral sclerosis or myelopathy. Based on novel methods, including inhomogeneous magnetization transfer (ihMT) and dedicated SC probabilistic atlas post-processing, the present study focuses on the in vivo characterization of the healthy SC tissue in terms of regional microstructure differences between (i) upper and lower cervical vertebral levels and (ii) sensory and motor tracts, as well as differences attributed to normal aging. Forty-eight healthy volunteers aged from 20 to 70 years old were included in the study and scanned at 3 T using axial high-resolution T2 *-w imaging, diffusion tensor imaging (DTI) and ihMT, at two vertebral levels (C2 and C5). A processing pipeline with minimal user intervention, SC segmentation and spatial normalization into a reference space was implemented in order to assess quantitative morphological and structural parameters (cross-sectional areas, scalar DTI and MT/ihMT metrics) in specific white and gray matter regions of interest. The multi-parametric MRI metrics collected allowed upper and lower cervical levels to be distinguished, with higher ihMT ratio (ihMTR), higher axial diffusivity (λ∥ ) and lower radial diffusivity (λ⊥ ) at C2 compared with C5. Significant differences were also observed between white matter fascicles, with higher ihMTR and lower λ∥ in motor tracts compared with posterior sensory tracts. Finally, aging was found to be associated with significant metric alterations (decreased ihMTR and λ∥ ). The methodology proposed here, which can be easily transferred to the clinic, provides new insights for SC characterization. It bears great potential to study focal and diffuse SC damage in neurodegenerative and demyelinating diseases. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Envelhecimento/patologia , Imagem de Tensor de Difusão/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Multimodal/métodos , Medula Espinal/citologia , Medula Espinal/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vias Neurais/citologia , Vias Neurais/fisiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
MAGMA ; 29(4): 699-709, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26762244

RESUMO

OBJECTIVES: The recently reported inhomogeneous magnetization transfer technique (ihMT) has been proposed for specific imaging of inhomogeneously broadened lines, and has shown great promise for characterizing myelinated tissues. The ihMT contrast is obtained by subtracting magnetization transfer images obtained with simultaneous saturation at positive and negative frequency offsets (dual frequency saturation experiment, MT (+/-)) from those obtained with single frequency saturation (MT (+)) at the same total power. Hence, ihMT may be biased by MT-asymmetry, especially at ultra-high magnetic field. Use of the average of single positive and negative frequency offset saturation MT images, i.e., (MT (+)+MT (-)) has been proposed to correct the ihMT signal from MT-asymmetry signal. MATERIALS AND METHODS: The efficiency of this correction method was experimentally assessed in this study, performed at 11.75 T on mice. Quantitative corrected ihMT and MT-asymmetry ratios (ihMTR and MTRasym) were measured in mouse brain structures for several MT-asymmetry magnitudes and different saturation parameter sets. RESULTS: Our results indicated a "safe" range of magnitudes (/MTRasym/<4 %) for which MT-asymmetry signal did not bias the corrected ihMT signal. Moreover, experimental evidence of the different natures of both MT-asymmetry and inhomogeneous MT contrasts were provided. In particular, non-zero ihMT ratios were obtained at zero MTRasym values. CONCLUSION: MTRasym is not a confounding factor for ihMT quantification, even at ultra-high field, as long as MTRasym is restricted to ±4 %.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética , Magnetismo , Bainha de Mielina/química , Algoritmos , Animais , Encéfalo/diagnóstico por imagem , Feminino , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Camundongos , Camundongos Endogâmicos C57BL
20.
J Affect Disord ; 356: 363-370, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38615848

RESUMO

BACKGROUND: Previous neuroimaging and pathological studies have found myelin-related abnormalities in bipolar disorder (BD), which prompted the use of magnetic resonance (MR) imaging technology sensitive to neuropathological changes to explore its neuropathological basis. We holistically investigated alterations in myelin within BD patients by inhomogeneous magnetization transfer (ihMT), which is sensitive and specific to myelin content. METHODS: Thirty-one BD and 42 healthy controls (HC) were involved. Four MR metrics, i.e., ihMT ratio (ihMTR), pseudo-quantitative ihMT (qihMT), magnetization transfer ratio and pseudo-quantitative magnetization transfer (qMT), were compared between groups using analysis methods based on whole-brain voxel-level and white matter regions of interest (ROI), respectively. RESULTS: The voxel-wise analysis showed significantly inter-group differences of ihMTR and qihMT in the corpus callosum. The ROI-wise analysis showed that ihMTR, qihMT, and qMT values in BD group were significantly lower than that in HC group in the genu and body of corpus callosum, left anterior limb of the internal capsule, left anterior corona radiate, and bilateral cingulum (p < 0.001). And the qihMT in genu of corpus callosum and right cingulum were negatively correlated with depressive symptoms in BD group. LIMITATIONS: This study is based on cross-sectional data and the sample size is limited. CONCLUSION: These findings suggest the reduced myelin content of anterior midline structure in the bipolar patients, which might be a critical pathophysiological feature of BD.


Assuntos
Transtorno Bipolar , Imageamento por Ressonância Magnética , Bainha de Mielina , Humanos , Transtorno Bipolar/diagnóstico por imagem , Transtorno Bipolar/patologia , Feminino , Masculino , Adulto , Bainha de Mielina/patologia , Pessoa de Meia-Idade , Corpo Caloso/diagnóstico por imagem , Corpo Caloso/patologia , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Estudos de Casos e Controles , Encéfalo/diagnóstico por imagem , Encéfalo/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA